Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sarah L. Bugby has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Seeing Gusty Winds: Optical Tracking of Tree Motion Captures Peak 3‐s Gust Velocities

    by Sai Kulkarni, John K. Hillier, Timothy I. Marjoribanks, Sarah L. Bugby, Jonny Higham, Daniel Bannister

    Peak 3‐s gust speed () is a key meteorological metric for potentially impactful winds. It is widely used in meteorology and engineering, but traditional anemometry is limited by sparse measurements. This proof‐of‐concept study is the first to relate Optical Flow Tracking Velocimetry (OFTV) derived wind estimates explicitly to , by capturing fine‐scale wind variability from video footage of trees. While calibration is required, this approach is simple, transparent and avoids the descriptor‐based Beaufort scale. So, it is a potential improvement or a component of frameworks that use machine learning or physics‐based structural approaches. Results from a pear tree in a domestic setting show correlations between OFTV‐ and cup‐anemometer data ( R 2 = 0.65, p < 0.05), confirming that can be extracted using only OFTV. Interestingly, OFTV‐ are consistent and strongly correlated ( R 2 ≥ 0.92) across a range of reference objects (i.e., a flag, parts of the tree crown, grass). This insight suggests that identifying specific objects is unnecessary in simple scenes, potentially simplifying future crowd‐sourced visual anemometry, although it may still be required in cluttered urban environments. Furthermore, occur across objects within ±1–5 s of each other, indicating a robustness of measurement. Collectively, these insights are a valuable step towards improved wind distribution mapping (e.g., with a nation's road network CCTV cameras) and detailed site hazard assessments for the (re)insurance sector.

  • Open Access

    Comparison of the charge transport properties of low and high flux grade redlen CdZnTe crystals

    by M. Bishop, M.C. Veale, S.L. Bugby, F.K. Dejene, M. Bettelli, S. Zanettini

    CdZnTe is widely used in gamma ray radiation detection for medical imaging and security, with growing interest in CdZnTe for synchrotron and XFEL detector materials at X-ray fluxes in excess of 1010 photons·s-1mm-2. Understanding fundamental material properties allows for greater understanding of the relevancy of CdZnTe for use at photon light sources. This investigation uses alpha particle spectroscopy to directly compare the mobility-lifetime products (μτ) and mobilities (μ) of High-Flux (HF) and Low-Flux (LF) CdZnTe, produced by Redlen Technologies, and ascertain the differences in bulk charge carrier properties for both electrons and holes. This work presents average values of HF-CdZnTe to be μe = 920 cm V-1 s-1, μh = 38 cm V-1 s-1, μe τe = 4.4 × 10-3 cm V-1 s-1, μh τh = 1.6 × 10-4 cm V-1 s-1 and LF-CdZnTe with μe = 840 cm V-1 s-1, μe τe = 12 × 10-3 cm V-1 s-1, μh τh = 0.4 × 10-4 cm V-1 s-1.


  • Open Access

    Seracam: characterisation of a new small field of view hybrid gamma camera for nuclear medicine

    by Sarah L. Bugby, Andrew L. Farnworth, William R. Brooks, Alan C. Perkins

    Background: Portable gamma cameras are being developed for nuclear medicine procedures such as thyroid scintigraphy. This article introduces Seracam® – a new technology that combines small field of view gamma imaging with optical imaging – and reports its performance and suitability for small organ imaging. Methods: The count rate capability, uniformity, spatial resolution, and sensitivity for 99mTc are reported for four integrated pinhole collimators of nominal sizes of 1 mm, 2 mm, 3 mm and 5 mm. Characterisation methodology is based on NEMA guidelines, with some adjustments necessitated by camera design. Two diagnostic scenarios – thyroid scintigraphy and gastric emptying – are simulated using clinically relevant activities and geometries to investigate application-specific performance. A qualitative assessment of the potential benefits and disadvantages of Seracam is also provided. Results: Seracam’s performance across the measured characteristics is appropriate for small field of view applications in nuclear medicine. At an imaging distance of 50 mm, corresponding to a field of view of 77.6 mm × 77.6 mm, spatial resolution ranged from 4.6 mm to 26 mm and sensitivity from 3.6 cps/MBq to 52.2 cps/MBq, depending on the collimator chosen. Results from the clinical simulations were particularly promising despite the challenging scenarios investigated. The optimal collimator choice was strongly application dependent, with gastric emptying relying on the higher sensitivity of the 5 mm pinhole whereas thyroid imaging benefitted from the enhanced spatial resolution of the 1 mm pinhole. Signal to noise ratio in images was improved by pixel binning. Seracam has lower measured sensitivity when compared to a traditional large field of view gamma camera, for the simulated applications this is balanced by advantages such as high spatial resolution, portability, ease of use and real time gamma-optical image fusion and display. Conclusion: The results show that Seracam has appropriate performance for small organ 99mTc imaging. The results also show that the performance of small field of view systems must be considered holistically and in clinically appropriate scenarios.


  • Open Access

    Efficient Retrieval of Images with Irregular Patterns Using Morphological Image Analysis: Applications to Industrial and Healthcare Datasets

    by Jiajun Zhang, Georgina Cosma, Sarah Bugby, Jason Watkins

    Image retrieval is the process of searching and retrieving images from a datastore based on their visual content and features. Recently, much attention has been directed towards the retrieval of irregular patterns within industrial or healthcare images by extracting features from the images, such as deep features, colour-based features, shape-based features, and local features. This has applications across a spectrum of industries, including fault inspection, disease diagnosis, and maintenance prediction. This paper proposes an image retrieval framework to search for images containing similar irregular patterns by extracting a set of morphological features (DefChars) from images. The datasets employed in this paper contain wind turbine blade images with defects, chest computerised tomography scans with COVID-19 infections, heatsink images with defects, and lake ice images. The proposed framework was evaluated with different feature extraction methods (DefChars, resized raw image, local binary pattern, and scale-invariant feature transforms) and distance metrics to determine the most efficient parameters in terms of retrieval performance across datasets. The retrieval results show that the proposed framework using the DefChars and the Manhattan distance metric achieves a mean average precision of 80% and a low standard deviation of ±0.09 across classes of irregular patterns, outperforming alternative feature–metric combinations across all datasets. Our proposed ImR framework performed better (by 8.71%) than Super Global, a state-of-the-art deep-learning-based image retrieval approach across all datasets.


  • Open Access

    Efficient Retrieval of Images with Irregular Patterns using Morphological Image Analysis: Applications to Industrial and Healthcare datasets

    by Jiajun Zhang, Georgina Cosma, Sarah Bugby, Jason Watkins

    Image retrieval is the process of searching and retrieving images from a database based on their visual content and features. Recently, much attention has been directed towards the retrieval of irregular patterns within industrial or medical images by extracting features from the images, such as deep features, colour-based features, shape-based features and local features. This has applications across a spectrum of industries, including fault inspection, disease diagnosis, and maintenance prediction. This paper proposes an image retrieval framework to search for images containing similar irregular patterns by extracting a set of morphological features (DefChars) from images; the datasets employed in this paper contain wind turbine blade images with defects, chest computerised tomography scans with COVID-19 infection, heatsink images with defects, and lake ice images. The proposed framework was evaluated with different feature extraction methods (DefChars, resized raw image, local binary pattern, and scale-invariant feature transforms) and distance metrics to determine the most efficient parameters in terms of retrieval performance across datasets. The retrieval results show that the proposed framework using the DefChars and the Manhattan distance metric achieves a mean average precision of 80% and a low standard deviation of 0.09 across classes of irregular patterns, outperforming alternative feature-metric combinations across all datasets. Furthermore, the low standard deviation between each class highlights DefChars' capability for a reliable image retrieval task, even in the presence of class imbalances or small-sized datasets.

  • Open Access

    ForestMonkey: Toolkit for Reasoning with AI-based Defect Detection and Classification Models

    by Jiajun Zhang, Georgina Cosma, Sarah Bugby, Jason Watkins

    Artificial intelligence (AI) reasoning and explainable AI (XAI) tasks have gained popularity recently, enabling users to explain the predictions or decision processes of AI models. This paper introduces Forest Monkey (FM), a toolkit designed to reason the outputs of any AI-based defect detection and/or classification model with data explainability. Implemented as a Python package, FM takes input in the form of dataset folder paths (including original images, ground truth labels, and predicted labels) and provides a set of charts and a text file to illustrate the reasoning results and suggest possible improvements. The FM toolkit consists of processes such as feature extraction from predictions to reasoning targets, feature extraction from images to defect characteristics, and a decision tree-based AI-Reasoner. Additionally, this paper investigates the time performance of the FM toolkit when applied to four AI models with different datasets. Lastly, a tutorial is provided to guide users in performing reasoning tasks using the FM toolkit.

  • Open Access

    Morphological Image Analysis and Feature Extraction for Reasoning with AI-based Defect Detection and Classification Models

    by Jiajun Zhang, Georgina Cosma, Sarah Bugby, Axel Finke, Jason Watkins

    As the use of artificial intelligent (AI) models becomes more prevalent in industries such as engineering and manufacturing, it is essential that these models provide transparent reasoning behind their predictions. This paper proposes the AI-Reasoner, which extracts the morphological characteristics of defects (DefChars) from images and utilises decision trees to reason with the DefChar values. Thereafter, the AI-Reasoner exports visualisations (i.e. charts) and textual explanations to provide insights into outputs made by masked-based defect detection and classification models. It also provides effective mitigation strategies to enhance data pre-processing and overall model performance. The AI-Reasoner was tested on explaining the outputs of an IE Mask R-CNN model using a set of 366 images containing defects. The results demonstrated its effectiveness in explaining the IE Mask R-CNN model's predictions. Overall, the proposed AI-Reasoner provides a solution for improving the performance of AI models in industrial applications that require defect analysis.

  • Open Access

    Intraoperative Gamma Cameras: A Review of Development in the Last Decade and Future Outlook

    by Andrew L. Farnworth, Sarah L. Bugby

    Portable gamma cameras suitable for intraoperative imaging are in active development and testing. These cameras utilise a range of collimation, detection, and readout architectures, each of which can have significant and interacting impacts on the performance of the system as a whole. In this review, we provide an analysis of intraoperative gamma camera development over the past decade. The designs and performance of 17 imaging systems are compared in depth. We discuss where recent technological developments have had the greatest impact, identify emerging technological and scientific requirements, and predict future research directions. This is a comprehensive review of the current and emerging state-of-the-art as more devices enter clinical practice.


  • Open Access

    Charge Sharing and Charge Loss in High-Flux Capable Pixelated CdZnTe Detectors

    by Kjell A. L. Koch-Mehrin, Sarah L. Bugby, John E. Lees, Matthew C. Veale, Matthew D. Wilson

    Cadmium zinc telluride (CdZnTe) detectors are known to suffer from polarization effects under high photon flux due to poor hole transport in the crystal material. This has led to the development of a high-flux capable CdZnTe material (HF-CdZnTe). Detectors with the HF-CdZnTe material have shown promising results at mitigating the onset of the polarization phenomenon, likely linked to improved crystal quality and hole carrier transport. Better hole transport will have an impact on charge collection, particularly in pixelated detector designs and thick sensors (>1 mm). In this paper, the presence of charge sharing and the magnitude of charge loss were calculated for a 2 mm thick pixelated HF-CdZnTe detector with 250 μm pixel pitch and 25 μm pixel gaps, bonded to the STFC HEXITEC ASIC. Results are compared with a CdTe detector as a reference point and supported with simulations from a Monte-Carlo detector model. Charge sharing events showed minimal charge loss in the HF-CdZnTe, resulting in a spectral resolution of 1.63 ± 0.08 keV Full Width at Half Maximum (FWHM) for bipixel charge sharing events at 59.5 keV. Depth of interaction effects were shown to influence charge loss in shared events. The performance is discussed in relation to the improved hole transport of HF-CdZnTe and comparison with simulated results provided evidence of a uniform electric field.