Kenichiro Yoshida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenichiro Yoshida has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Kayoko Iwata
5 shared publicationsNobutoshi Ojima
Kao Corporation, Beauty Research Center, 2-1-3 Bunka, Sumida-ku, Tokyo 131-8501, Japan
4 shared publicationsIzumi Nishidate
Kao Corporation, Skin Care Products Research, Tokyo, Japan
2 shared publications- Natsuko Okiyama
Kao Corporation, Makeup Products Research
2 shared publications Takanori Igarashi
Kao Corporation, Skin Care Products Research
2 shared publications- Akihiko Fujii
Kao Corporation
1 shared publication
Latest Publications
- 19 July 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (8) , 4775-4785
Age dependency of the reduced scattering coefficient and viscoelastic character, and their relationship in Japanese female skin
We measured the reduced scattering coefficient (µs’) with the edge-loss method at skin sites on the faces and upper arms of Japanese females aged 20s to 50s, and observed significant negative correlations at all sites, including the mouth. At the same mouth site, we also measured the viscoelastic properties with a Cutometer MPA580 and evaluated their correlation with µs’. Significant correlations were observed for the parameters of pliability, the portion of the viscoelasticity during the suction phase, and total recovery from the Cutometer against µs’ with the effect of age removed. The results experimentally suggest the relation between µs’ and the collagen condition.
- 19 July 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (8) , 4775-4785
Age dependency of the reduced scattering coefficient and viscoelastic character, and their relationship in Japanese female skin
We measured the reduced scattering coefficient (µs’) with the edge-loss method at skin sites on the faces and upper arms of Japanese females aged 20s to 50s, and observed significant negative correlations at all sites, including the mouth. At the same mouth site, we also measured the viscoelastic properties with a Cutometer MPA580 and evaluated their correlation with µs’. Significant correlations were observed for the parameters of pliability, the portion of the viscoelasticity during the suction phase, and total recovery from the Cutometer against µs’ with the effect of age removed. The results experimentally suggest the relation between µs’ and the collagen condition.
- 11 March 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (6) , 10199-10216
Visualization of reflectance, transmittance, and application amount distribution of the cosmetic foundation layer on skin
We developed a method for visualization of makeup finishing with structured lighting. By analyzing images with a sequence of projection patterns, reflectance and transmittance of the cosmetic foundation (FD) layer were extracted as spatial maps using the difference between the light spread of bare skin and made-up skin. The spatial maps reflect conditions and distribution of applied FD under real situations. By calibrating the relationship between optical properties and the amount of FD applied, the application amount distribution was also estimated. Additionally, we proposed approximation formulae to estimate the above values without images of bare skin. These formulae provide good agreement with the original formula for reflectance. (C) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
- 11 March 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (6) , 10199-10216
Visualization of reflectance, transmittance, and application amount distribution of the cosmetic foundation layer on skin
We developed a method for visualization of makeup finishing with structured lighting. By analyzing images with a sequence of projection patterns, reflectance and transmittance of the cosmetic foundation (FD) layer were extracted as spatial maps using the difference between the light spread of bare skin and made-up skin. The spatial maps reflect conditions and distribution of applied FD under real situations. By calibrating the relationship between optical properties and the amount of FD applied, the application amount distribution was also estimated. Additionally, we proposed approximation formulae to estimate the above values without images of bare skin. These formulae provide good agreement with the original formula for reflectance. (C) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
- Open Access
- 16 November 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (24) , 40038-40050
Estimation of reflectance, transmittance, and absorbance of cosmetic foundation layer on skin using translucency of skin
We developed a method to estimate the reflectance, transmittance, and absorbance of a layer of cosmetic foundation (FD) applied to skin from the reflectance of bare skin and FD applied to skin under two measurement conditions using the translucency of skin. Conversely, using the relationship between the applied amount of FD and the reflectance of the FD layer, the applied amount could be estimated. These values could be measured stably regardless of the similarity of reflectance and color between bare skin and made-up skin. The measured values were taken from actual skin, which satisfies the condition of actual usage.
- 16 November 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (24) , 40038-40050
Open AccessEstimation of reflectance, transmittance, and absorbance of cosmetic foundation layer on skin using translucency of skin
We developed a method to estimate the reflectance, transmittance, and absorbance of a layer of cosmetic foundation (FD) applied to skin from the reflectance of bare skin and FD applied to skin under two measurement conditions using the translucency of skin. Conversely, using the relationship between the applied amount of FD and the reflectance of the FD layer, the applied amount could be estimated. These values could be measured stably regardless of the similarity of reflectance and color between bare skin and made-up skin. The measured values were taken from actual skin, which satisfies the condition of actual usage.
- Open Access
- 28 January 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Phase Velocity of Facial Blood Volume Oscillation at a Frequency of 0.1 Hz
Facial blood flow, which typically exhibits distinctive oscillation at a frequency of around 0.1 Hz, has been extensively studied. Although this oscillation may include important information about blood flow regulation, its origin remains unknown. The spatial phase distribution of the oscillation is thus desirable. Therefore, we visualized facial blood volume oscillation at a frequency of around 0.1 Hz using a digital camera imaging method with an improved approximation equation, which enabled precise analysis over a large area. We observed a slow spatial movement of the 0.1-Hz oscillation. The oscillation phase was not synchronized, but instead moved slowly. The phase velocity varies with person, measurement location, and time. An average phase velocity of 3.8 mm/s was obtained for several subjects. The results are consistent with previous studies; however, the conventional explanation that the blood flow at a certain point oscillates independently of adjacent areas should be corrected. If the primary origin of the movement is myogenic activity, the movement may ascend along a blood vessel toward the upstream. Otherwise, the oscillation and its propagation can be considered to be related to Mayer waves. By determining the mechanism, some questions regarding Mayer waves can be answered. The direction of the wave (upstream or downstream) provides important information.
- 28 January 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Open AccessPhase Velocity of Facial Blood Volume Oscillation at a Frequency of 0.1 Hz
Facial blood flow, which typically exhibits distinctive oscillation at a frequency of around 0.1 Hz, has been extensively studied. Although this oscillation may include important information about blood flow regulation, its origin remains unknown. The spatial phase distribution of the oscillation is thus desirable. Therefore, we visualized facial blood volume oscillation at a frequency of around 0.1 Hz using a digital camera imaging method with an improved approximation equation, which enabled precise analysis over a large area. We observed a slow spatial movement of the 0.1-Hz oscillation. The oscillation phase was not synchronized, but instead moved slowly. The phase velocity varies with person, measurement location, and time. An average phase velocity of 3.8 mm/s was obtained for several subjects. The results are consistent with previous studies; however, the conventional explanation that the blood flow at a certain point oscillates independently of adjacent areas should be corrected. If the primary origin of the movement is myogenic activity, the movement may ascend along a blood vessel toward the upstream. Otherwise, the oscillation and its propagation can be considered to be related to Mayer waves. By determining the mechanism, some questions regarding Mayer waves can be answered. The direction of the wave (upstream or downstream) provides important information.
- 4 November 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (11) , 3127-3140
Noise reduction from chromophore images and reliability improvement by successive minimization of intermixture in the modified Lambert-Beer law
We developed an optimization method of chromophore vectors for skin images in the modified Lambert-Beer law. In the proposed method, vectors are optimized to minimize intermixture between melanin, hemoglobin, and shading components. Using the proposed method, the vectors can be optimized appropriately and stably. The proposed method also optimizes shading images, which may contain useful information. The melanin component obtained using the proposed method has a good correlation with that obtained from the conventional method with a reflectance spectrum. The proposed method advances the capability of prompt action upon installation of new equipment and eliminates arbitrary judgment of acceptance or rejection of vectors for each test image, which improves objectivity.
- 4 November 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (11) , 3127-3140
Noise reduction from chromophore images and reliability improvement by successive minimization of intermixture in the modified Lambert-Beer law
We developed an optimization method of chromophore vectors for skin images in the modified Lambert-Beer law. In the proposed method, vectors are optimized to minimize intermixture between melanin, hemoglobin, and shading components. Using the proposed method, the vectors can be optimized appropriately and stably. The proposed method also optimizes shading images, which may contain useful information. The melanin component obtained using the proposed method has a good correlation with that obtained from the conventional method with a reflectance spectrum. The proposed method advances the capability of prompt action upon installation of new equipment and eliminates arbitrary judgment of acceptance or rejection of vectors for each test image, which improves objectivity.
- 1 May 2017
- Published by Elsevier in Journal of Dermatological Science
- Vol. 86 (2) , e47
Relationships between transepidermal water loss, cutaneous microcirculatory function and autonomic nerve activity
- 1 May 2017
- Published by Elsevier in Journal of Dermatological Science
- Vol. 86 (2) , e47
Relationships between transepidermal water loss, cutaneous microcirculatory function and autonomic nerve activity
- 5 July 2016
- Published by Springer Nature in Optical Review
- Vol. 23 (4) , 579-586
Derivation of absorption coefficient and reduced scattering coefficient with edge-loss method and comparison with video reflectometry method
- 5 July 2016
- Published by Springer Nature in Optical Review
- Vol. 23 (4) , 579-586
Derivation of absorption coefficient and reduced scattering coefficient with edge-loss method and comparison with video reflectometry method
- Open Access
- 13 October 2014
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 5 (11) , 3901-3920
Rapid calculation of diffuse reflectance from a multilayered model by combination of the white Monte Carlo and adding-doubling methods
To rapidly derive a result for diffuse reflectance from a multilayered model that is equivalent to that of a Monte-Carlo simulation (MCS), we propose a combination of a layered white MCS and the adding-doubling method. For slabs with various scattering coefficients assuming a certain anisotropy factor and without absorption, we calculate the transition matrices for light flow with respect to the incident and exit angles. From this series of precalculated transition matrices, we can calculate the transition matrices for the multilayered model with the specific anisotropy factor. The relative errors of the results of this method compared to a conventional MCS were less than 1%. We successfully used this method to estimate the chromophore concentration from the reflectance spectrum of a numerical model of skin and in vivo human skin tissue.
- 13 October 2014
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 5 (11) , 3901-3920
Open AccessRapid calculation of diffuse reflectance from a multilayered model by combination of the white Monte Carlo and adding-doubling methods
To rapidly derive a result for diffuse reflectance from a multilayered model that is equivalent to that of a Monte-Carlo simulation (MCS), we propose a combination of a layered white MCS and the adding-doubling method. For slabs with various scattering coefficients assuming a certain anisotropy factor and without absorption, we calculate the transition matrices for light flow with respect to the incident and exit angles. From this series of precalculated transition matrices, we can calculate the transition matrices for the multilayered model with the specific anisotropy factor. The relative errors of the results of this method compared to a conventional MCS were less than 1%. We successfully used this method to estimate the chromophore concentration from the reflectance spectrum of a numerical model of skin and in vivo human skin tissue.
- Open Access
- 1 January 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (1) , 016009
Reduction of shading-derived artifacts in skin chromophore imaging without measurements or assumptions about the shape of the subject
To quantitatively evaluate skin chromophores over a wide region of curved skin surface, we propose an approach that suppresses the effect of the shading-derived error in the reflectance on the estimation of chromophore concentrations, without sacrificing the accuracy of that estimation. In our method, we use multiple regression analysis, assuming the absorbance spectrum as the response variable and the extinction coefficients of melanin, oxygenated hemoglobin, and deoxygenated hemoglobin as the predictor variables. The concentrations of melanin and total hemoglobin are determined from the multiple regression coefficients using compensation formulae (CF) based on the diffuse reflectance spectra derived from a Monte Carlo simulation. To suppress the shading-derived error, we investigated three different combinations of multiple regression coefficients for the CF. In vivo measurements with the forearm skin demonstrated that the proposed approach can reduce the estimation errors that are due to shading-derived errors in the reflectance. With the best combination of multiple regression coefficients, we estimated that the ratio of the error to the chromophore concentrations is about 10%. The proposed method does not require any measurements or assumptions about the shape of the subjects; this is an advantage over other studies related to the reduction of shading-derived errors.
- 1 January 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (1) , 016009
Open AccessReduction of shading-derived artifacts in skin chromophore imaging without measurements or assumptions about the shape of the subject
To quantitatively evaluate skin chromophores over a wide region of curved skin surface, we propose an approach that suppresses the effect of the shading-derived error in the reflectance on the estimation of chromophore concentrations, without sacrificing the accuracy of that estimation. In our method, we use multiple regression analysis, assuming the absorbance spectrum as the response variable and the extinction coefficients of melanin, oxygenated hemoglobin, and deoxygenated hemoglobin as the predictor variables. The concentrations of melanin and total hemoglobin are determined from the multiple regression coefficients using compensation formulae (CF) based on the diffuse reflectance spectra derived from a Monte Carlo simulation. To suppress the shading-derived error, we investigated three different combinations of multiple regression coefficients for the CF. In vivo measurements with the forearm skin demonstrated that the proposed approach can reduce the estimation errors that are due to shading-derived errors in the reflectance. With the best combination of multiple regression coefficients, we estimated that the ratio of the error to the chromophore concentrations is about 10%. The proposed method does not require any measurements or assumptions about the shape of the subjects; this is an advantage over other studies related to the reduction of shading-derived errors.
- Open Access
- 1 March 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (3) , 037002
Application of the critical angle method to refractive index measurement of human skinin vivounder partial contact
We adapted the critical angle method for measuring rough surfaces under partial contact to acquire an in vivo skin refractive index (RI). Assuming that the total reflection is the simple sum of reflection from areas that are in contact and reflection from those that are not in contact, the RI can be estimated even for partial contact with a rough surface. We found that cheek skin is sufficiently soft that a sufficiently large area can be in contact and that the critical angle was detectable. The RIs of the cheeks of adult females were measured. The RI range was about 1.51 to 1.53, at a wavelength of 550 nm, without considering systematic errors. The RIs of cheeks are significantly correlated with their conductance, which corresponds to their water content. We determined the relationship between the RI and conductance within the variation of skin under normal conditions; this relationship was theoretically obtained in previous studies. In the present study, a direct in vivo measurement method was developed that enabled us to measure the RI in daily life, although this method contains errors for several reasons, including disregarding absorption.
- 1 March 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (3) , 037002
Open AccessApplication of the critical angle method to refractive index measurement of human skinin vivounder partial contact
We adapted the critical angle method for measuring rough surfaces under partial contact to acquire an in vivo skin refractive index (RI). Assuming that the total reflection is the simple sum of reflection from areas that are in contact and reflection from those that are not in contact, the RI can be estimated even for partial contact with a rough surface. We found that cheek skin is sufficiently soft that a sufficiently large area can be in contact and that the critical angle was detectable. The RIs of the cheeks of adult females were measured. The RI range was about 1.51 to 1.53, at a wavelength of 550 nm, without considering systematic errors. The RIs of cheeks are significantly correlated with their conductance, which corresponds to their water content. We determined the relationship between the RI and conductance within the variation of skin under normal conditions; this relationship was theoretically obtained in previous studies. In the present study, a direct in vivo measurement method was developed that enabled us to measure the RI in daily life, although this method contains errors for several reasons, including disregarding absorption.