Srijith Kanakambaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Srijith Kanakambaran has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Archana Thrikkaikuth Chalackal
Electronics and Communication Engineering Department, Design and Manufacturing, Kancheepuram, Indian Institute of Information Technology, Chennai, India
2 shared publications - Balaji Srinivasan
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India
2 shared publications Archana Thrikkaikuth Chalackal
1 shared publicationArchana Trikkaikuth Chalackal
Fiber Optic Sensing Laboratory, Department of Electronics and Communication Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram, Chennai, India
1 shared publication- Deepika Sasi
Department of Electronics and Communication Engineering, National Institute of Technology Puducherry, Karaikal, India
1 shared publication - Dinesh Lakshmanan
Indian Institute of Information Technology, Design and Manufacturing Kancheepuram
1 shared publication
Latest Publications
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19341-19348
Elbow Angle Monitoring and Error Analysis Using a Wearable PDMS Embedded FBG Sensor
Elbow flexion and extension are necessary movements for daily tasks. Elbow joint impairments can be brought on by aging, accidents, and repetitive motions making the monitoring of elbow angles critical. In this work, a sensor for elbow angle monitoring during bending and extension using a Fiber Bragg Grating (FBG) embedded in polydimethylsiloxane (PDMS) with a wearable band is proposed. Two methods for measuring elbow angles, wearable and platform-based sensing are investigated. The wearable sensor based measurements are consistent over different trials with a linear variation of Bragg wavelength with flexion/extension angle up to 90°. The sensitivities for flexion and extension are 0.0029 nm/° and 0.0037 nm/° respectively. Further, the factors contributing to error in the measurement of elbow angle such as tightness of wearable band, spatial and angular misalignment of the sensor and the removal and replacement of sensor are studied. The findings show that the error is maximum for an angular misalignment followed by tightly bound sensor and spatial misalignment. The desirable configuration for elbow angle measurement is a tightly bound sensor at the mean position for high mean sensitivity with a tolerable level of error and a left/right-aligned sensor with moderate tightness for minimum error at a low sensitivity. The PDMS-embedded FBG-based wearable sensor, in an optimal configuration, can be used for monitoring elbow angles.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19341-19348
Elbow Angle Monitoring and Error Analysis Using a Wearable PDMS Embedded FBG Sensor
Elbow flexion and extension are necessary movements for daily tasks. Elbow joint impairments can be brought on by aging, accidents, and repetitive motions making the monitoring of elbow angles critical. In this work, a sensor for elbow angle monitoring during bending and extension using a Fiber Bragg Grating (FBG) embedded in polydimethylsiloxane (PDMS) with a wearable band is proposed. Two methods for measuring elbow angles, wearable and platform-based sensing are investigated. The wearable sensor based measurements are consistent over different trials with a linear variation of Bragg wavelength with flexion/extension angle up to 90°. The sensitivities for flexion and extension are 0.0029 nm/° and 0.0037 nm/° respectively. Further, the factors contributing to error in the measurement of elbow angle such as tightness of wearable band, spatial and angular misalignment of the sensor and the removal and replacement of sensor are studied. The findings show that the error is maximum for an angular misalignment followed by tightly bound sensor and spatial misalignment. The desirable configuration for elbow angle measurement is a tightly bound sensor at the mean position for high mean sensitivity with a tolerable level of error and a left/right-aligned sensor with moderate tightness for minimum error at a low sensitivity. The PDMS-embedded FBG-based wearable sensor, in an optimal configuration, can be used for monitoring elbow angles.
- 23 December 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (1) , 015049
Investigations on thermal and mechanical characteristics of PDMS embedded FBG sensors for wearable sensing applications
Fiber Bragg Grating (FBG) sensors embedded in polydimethylsiloxane (PDMS) are suitable for real-time monitoring of parameters like strain, temperature, force etc. This work investigates the thermal and mechanical properties of PDMS samples at mixing ratios of 6:1, 10:1, and 15:1 with embedded FBGs. The 10:1 sample showed the highest temperature sensitivity of 22.51 ± 0.54 pm ∘C−1. Young’s modulus values from mechanical characterization ranged from 2.20–8.16 MPa, 2.56–7.68 MPa, and 0.44–5.02 MPa for mixing ratios 6:1, 10:1, and 15:1, respectively. The highest force and strain sensitivities were 1.356 nm N−1 and 0.153 pm/µε for the 10:1 ratio, making it preferable for wearable sensors.
- 23 December 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (1) , 015049
Investigations on thermal and mechanical characteristics of PDMS embedded FBG sensors for wearable sensing applications
Fiber Bragg Grating (FBG) sensors embedded in polydimethylsiloxane (PDMS) are suitable for real-time monitoring of parameters like strain, temperature, force etc. This work investigates the thermal and mechanical properties of PDMS samples at mixing ratios of 6:1, 10:1, and 15:1 with embedded FBGs. The 10:1 sample showed the highest temperature sensitivity of 22.51 ± 0.54 pm ∘C−1. Young’s modulus values from mechanical characterization ranged from 2.20–8.16 MPa, 2.56–7.68 MPa, and 0.44–5.02 MPa for mixing ratios 6:1, 10:1, and 15:1, respectively. The highest force and strain sensitivities were 1.356 nm N−1 and 0.153 pm/µε for the 10:1 ratio, making it preferable for wearable sensors.
- 12 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34487-34497
Spectral Similarity Estimation and ML-Based Classification of Speech Using PDMS-Embedded FBG Sensor-Based Contact Microphone
A Fiber Bragg Grating sensor based Contact Microphone (FBGCM) system for speech classification has been demonstrated in this work. Ambient noise insensitivity feature of these microphones gives them an edge over the conventional ones. When attached to the surface of an audio device or the human throat, they pick up vibrations generated by the sound produced. The captured vibrations are converted into shifts in the Bragg wavelength, enabling the extraction of spectral information. Time domain, frequency domain, volume-amplitude, noise and similarity analyses were conducted to characterize the FBGCM and Machine Learning (ML) models were used for speech classification. A non linear spectral response has been observed by the analysis of magnitude spectrum in the range of 100-2000 Hz. Amplitude of the recorded data increased linearly up to 60% volume level and saturated thereafter. The FBGCM also demonstrated superior noise immunity compared to a standard voice recorder, with its average SNR values being 5.4 dB higher. Spectral similarity analysis indicated that the horizontal placement of FBGCM resulted in a better response compared to the vertical orientation. Furthermore, 70 % of the target words showed an improvement in the spectral response with a PDMS embedded FBG Sensor. An accuracy of 90 % and a precision of 91% have been achieved for speech classification using ML models.
- 12 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34487-34497
Spectral Similarity Estimation and ML-Based Classification of Speech Using PDMS-Embedded FBG Sensor-Based Contact Microphone
A Fiber Bragg Grating sensor based Contact Microphone (FBGCM) system for speech classification has been demonstrated in this work. Ambient noise insensitivity feature of these microphones gives them an edge over the conventional ones. When attached to the surface of an audio device or the human throat, they pick up vibrations generated by the sound produced. The captured vibrations are converted into shifts in the Bragg wavelength, enabling the extraction of spectral information. Time domain, frequency domain, volume-amplitude, noise and similarity analyses were conducted to characterize the FBGCM and Machine Learning (ML) models were used for speech classification. A non linear spectral response has been observed by the analysis of magnitude spectrum in the range of 100-2000 Hz. Amplitude of the recorded data increased linearly up to 60% volume level and saturated thereafter. The FBGCM also demonstrated superior noise immunity compared to a standard voice recorder, with its average SNR values being 5.4 dB higher. Spectral similarity analysis indicated that the horizontal placement of FBGCM resulted in a better response compared to the vertical orientation. Furthermore, 70 % of the target words showed an improvement in the spectral response with a PDMS embedded FBG Sensor. An accuracy of 90 % and a precision of 91% have been achieved for speech classification using ML models.
- 14 August 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 50 (8) , 5573-5587
Hybrid CNN-LightGBM Architecture for Earthquake Event Classification in DAS Systems
- 14 August 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 50 (8) , 5573-5587
Hybrid CNN-LightGBM Architecture for Earthquake Event Classification in DAS Systems
- 16 January 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (2) , 025007
In-vivo studies on PDMS-embedded fiber Bragg grating based smart laparoscopic grasper
Minimally invasive surgeries are often associated with the risk of tissue damage due to improper force feedback mechanisms to notify surgeons regarding the force thresholds. This work evaluates the grasping forces during tissue handling to offer force feedback and assist surgeons during tissue manipulation. A polydimethylsiloxane embedded fiber Bragg grating sensor was developed and integrated at the tip of the laparoscopic grasper to measure the grasping force. Simulation studies have been performed to investigate the performance of the embedded grating sensor. The sensitivity of the sensor embedded within polydimethylsiloxane was found to be around 31.4 pm N−1 which was better compared to that of a silicone embedded counterpart. In-vivo studies were performed with soft tissue phantoms prepared with silicone rubber interspersed with different concentrations of mineral oil. Experimental results reveal a decrease in the peak wavelength shift as the tissue gets softer which is consistent with the nature of grasping force for softer tissues.
- 16 January 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (2) , 025007
In-vivo studies on PDMS-embedded fiber Bragg grating based smart laparoscopic grasper
Minimally invasive surgeries are often associated with the risk of tissue damage due to improper force feedback mechanisms to notify surgeons regarding the force thresholds. This work evaluates the grasping forces during tissue handling to offer force feedback and assist surgeons during tissue manipulation. A polydimethylsiloxane embedded fiber Bragg grating sensor was developed and integrated at the tip of the laparoscopic grasper to measure the grasping force. Simulation studies have been performed to investigate the performance of the embedded grating sensor. The sensitivity of the sensor embedded within polydimethylsiloxane was found to be around 31.4 pm N−1 which was better compared to that of a silicone embedded counterpart. In-vivo studies were performed with soft tissue phantoms prepared with silicone rubber interspersed with different concentrations of mineral oil. Experimental results reveal a decrease in the peak wavelength shift as the tissue gets softer which is consistent with the nature of grasping force for softer tissues.
- 10 June 2023
- Published by Elsevier in NDT & E International
- Vol. 138
Sparse sampled visualization of ultrasonic guided waves for defect identification in plate structures
- 10 June 2023
- Published by Elsevier in NDT & E International
- Vol. 138
Sparse sampled visualization of ultrasonic guided waves for defect identification in plate structures
- 2 September 2021
- Published by Springer Nature
- p. 189-194
Simulation Studies on Force Sensor Using PDMS Coated Fiber Bragg Grating for Robot-Assisted Surgery
- 2 September 2021
- Published by Springer Nature
- p. 189-194
Simulation Studies on Force Sensor Using PDMS Coated Fiber Bragg Grating for Robot-Assisted Surgery
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (24) , 10018-10027
Robust Classification of Partial Discharges in Transformer Insulation Based on Acoustic Emissions Detected Using Fiber Bragg Gratings
Incipient discharges formed due to corona activity, surface discharge and particle movement in transformer insulation are identified based on acoustic emission signals captured using fiber Bragg grating sensors and analyzed in the frequency domain. To improve the SNR of these signals, the use of adaptive line enhancement based technique is systematically explored through simulations and the associated parameters are optimized. The noise filtered spectra analyzed through ternary diagrams suggest the possibility of classifying the discharges which are further validated using appropriate classifiers. Experimental comparison of discharges generated in different oil media like mineral oil, nanoparticle-dispersed mineral oil, ester oil and nanoparticle-dispersed ester oil reveals that the discharge characteristics are similar across multiple media and the classification holds good.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (24) , 10018-10027
Robust Classification of Partial Discharges in Transformer Insulation Based on Acoustic Emissions Detected Using Fiber Bragg Gratings
Incipient discharges formed due to corona activity, surface discharge and particle movement in transformer insulation are identified based on acoustic emission signals captured using fiber Bragg grating sensors and analyzed in the frequency domain. To improve the SNR of these signals, the use of adaptive line enhancement based technique is systematically explored through simulations and the associated parameters are optimized. The noise filtered spectra analyzed through ternary diagrams suggest the possibility of classifying the discharges which are further validated using appropriate classifiers. Experimental comparison of discharges generated in different oil media like mineral oil, nanoparticle-dispersed mineral oil, ester oil and nanoparticle-dispersed ester oil reveals that the discharge characteristics are similar across multiple media and the classification holds good.