AFAaron S. Field

Aaron S. Field

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aaron S. Field has a total of 82 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of a Simple MRI Scoring Tool in Severe Pediatric Traumatic Brain Injury: Secondary Analysis of the 2014–2017 “Approaches and Decisions in Acute Pediatric TBI Trial (ADAPT)” Multicenter Study

    by Anna M. Janas, Furkan Camci, Aimee T. Broman, Susan Rebsamen, Aaron S. Field, Kerri L. LaRovere, Bedda L. Rosario, Michael J. Bell, Andrew L. Alexander, Peter A. Ferrazzano

    OBJECTIVES: We aimed to describe the frequency, depth, and co-occurrence of different intracerebral injury types detected on the first clinical brain MRI in children with severe traumatic brain injury (TBI) and to derive a simple MRI scoring system associated with 12-month functional outcome. DESIGN: Secondary analysis of the Approaches and Decision in Acute Pediatric TBI (ADAPT) multicenter 2014 to 2017 study. SETTING: A total of 24 ADAPT sites in the United States, United Kingdom, and Australia. PATIENTS: Children (< 18 yr) with severe TBI who received intracranial pressure monitoring and clinical brain MRI within 30 days of injury. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: MRI was evaluated for lesion type and location, and maximal depth of any lesion was determined for each subject (grade 1, lobar gray and white matter; grade 2, deep gray matter and corpus callosum; grade 3, brainstem). The primary outcome was Glasgow Outcome Scale Extended Pediatric version (GOSE-P) at 12 months, dichotomized to favorable (GOSE-P 1–3) vs. unfavorable (GOSE-P 4–8). In the cohort of 279 patients, we found that the three most frequent lesion types were contusion (78.5%), diffuse axonal injury (70.3%), and ischemia (38.0%). When evaluating maximal injury grade, grade 1 was present in 48 children (17.2%), grade 2 in 103 children (36.9%), and grade 3 in 113 children (40.5%). Injury grade and presence of ischemia were associated with increased odds of unfavorable outcome. Injury depth and ischemia on MRI (IDIOM) were incorporated into a novel six-category MRI Injury Scale, with scores ranging from 1 to 3+ (injury grades 1–3, + indicates presence of any ischemia). We found that score 3+, that is, brainstem injury with ischemia in any location, increased the risk of unfavorable outcome 22.3-fold (95% CI, 6.81–87.37; p < 0.0001) compared with score 1 (injury isolated to lobar gray and white matter, without ischemia). CONCLUSIONS: Increased depth of injury and presence of ischemia on MRI are important risk factors for unfavorable outcome in children with severe TBI. We propose a simple MRI scoring system (IDIOM) that incorporates depth of injury and presence of ischemia that may be useful for neuroprognostication, but further validation is required.

  • Dose Reduction with Gadopiclenol: Implications for DSC Perfusion Imaging

    by Alexey Samsonov, Mohamed Shaif Yusufishaq, Seth Arntz, Aaron Field

    Gadopiclenol (Vueway) has a substantially higher T1 relaxivity than other gadolinium-based contrast agents, including gadobenate dimeglumine (MultiHance), allowing a 50% dose reduction with noninferiority in detection of enhancing lesions on T1-weighted imaging. However, such reduced dosing may have unintended consequences for DSC perfusion imaging. In this retrospective analysis of 30 patients imaged using package-insert dosing of both MultiHance and Vueway (on separate occasions), DSC signal transients were compared between these agents. There was a statistically significant reduction in % signal change and area under the contrast concentration-time curve for Vueway relative to MultiHance. When the signal was normalized for contrast dose, this difference was statistically eliminated. The results demonstrate that package-insert dosing of Vueway produces substantially weaker signal transients for DSC perfusion imaging, in proportion to the one-half gadolinium dose regimen. Potential impact on perfusion metrics, with concerns including SNR and leakage correction, warrants further study.


  • Focused Abbreviated Survey MRI Protocols for Brain and Spine Imaging

    by Laura B. Eisenmenger, Anthony Peret, Grant S. Roberts, Alma Spahic, Chenwei Tang, Anthony D. Kuner, Allison M. Grayev, Aaron S. Field, Howard A. Rowley, Tabassum A. Kennedy

    There has been extensive growth in both the technical development and the clinical applications of MRI, establishing this modality as one of the most powerful diagnostic imaging tools. However, long examination and image interpretation times still limit the application of MRI, especially in emergent clinical settings. Rapid and abbreviated MRI protocols have been developed as alternatives to standard MRI, with reduced imaging times, and in some cases limited numbers of sequences, to more efficiently answer specific clinical questions. A group of rapid MRI protocols used at the authors' institution, referred to as FAST (focused abbreviated survey techniques), are designed to include or exclude emergent or urgent conditions or screen for specific entities. These FAST protocols provide adequate diagnostic image quality with use of accelerated approaches to produce imaging studies faster than traditional methods. FAST protocols have become critical diagnostic screening tools at the authors' institution, allowing confident and efficient confirmation or exclusion of actionable findings. The techniques commonly used to reduce imaging times, the imaging protocols used at the authors' institution, and future directions in FAST imaging are reviewed to provide a practical and comprehensive overview of FAST MRI for practicing neuroradiologists. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


  • Diffusion Tensor Magnetic Resonance Imaging – Physical Principles

    by Jose Guerrero, Thomas A. Gallagher, Andrew L. Alexander, Aaron S. Field


  • Open Access

    Incidental Findings from 16,400 Brain MRI Examinations of Research Volunteers

    by P.A. Rowley, M.J. Paukner, L.B. Eisenmenger, A.S. Field, R.J. Davidson, S.C. Johnson, S. Asthana, N.A. Chin, V. Prabhakaran, B.B. Bendlin, et al.

    BACKGROUND AND PURPOSE: Incidental findings are discovered in neuroimaging research, ranging from trivial to life-threatening. We describe the prevalence and characteristics of incidental findings from 16,400 research brain MRIs, comparing spontaneous detection by nonradiology scanning staff versus formal neuroradiologist interpretation. MATERIALS AND METHODS: We prospectively collected 16,400 brain MRIs (7782 males, 8618 females; younger than 1 to 94 years of age; median age, 38 years) under an institutional review board directive intended to identify clinically relevant incidental findings. The study population included 13,150 presumed healthy volunteers and 3250 individuals with known neurologic diagnoses. Scanning staff were asked to flag concerning imaging findings seen during the scan session, and neuroradiologists produced structured reports after reviewing every scan. RESULTS: Neuroradiologists reported 13,593/16,400 (83%) scans as having normal findings, 2193/16,400 (13.3%) with abnormal findings without follow-up recommended, and 614/16,400 (3.7%) with “abnormal findings with follow-up recommended.” The most common abnormalities prompting follow-up were vascular (263/614, 43%), neoplastic (130/614, 21%), and congenital (92/614, 15%). Volunteers older than 65 years of age were significantly more likely to have scans with abnormal findings (P < .001); however, among all volunteers with incidental findings, those younger than 65 years of age were more likely to be recommended for follow-up. Nonradiologists flagged <1% of MRIs containing at least 1 abnormality reported by the neuroradiologists to be concerning enough to warrant further evaluation. CONCLUSIONS: Four percent of individuals who undergo research brain MRIs have an incidental, potentially clinically significant finding. Routine neuroradiologist review of all scans yields a much higher rate of significant lesion detection than selective referral from nonradiologists who perform the examinations. Workflow and scan review processes need to be carefully considered when designing research protocols.


  • Open Access

    High‐resolution dynamic susceptibility contrast perfusion imaging using higher‐order temporal smoothness regularization

    by Julia V. Velikina, Youngkyoo Jung, Aaron S. Field, Alexey A. Samsonov

    Purpose: To improve image quality and resolution of dynamic susceptibility contrast perfusion weighted imaging (DSC‐PWI) by developing acquisition and reconstruction methods exploiting the temporal regularity property of DSC‐PWI signal.Theory and Methods: A novel regularized reconstruction is proposed that recovers DSC‐PWI series from interleaved segmented spiralk‐space acquisition using higher order temporal smoothness (HOTS) properties of the DSC‐PWI signal. The HOTS regularization is designed to tackle representational insufficiency of the standard first‐order temporal regularizations for supporting higher accelerations. The higher accelerations allow fork‐space coverage with shorter spiral interleaves resulting in improved acquisition point spread function, and acquisition of images at multiple TEs for more accurate DSC‐PWI analysis.Results: The methods were evaluated in simulated and in‐vivo studies. HOTS regularization provided increasingly more accurate models for DSC‐PWI than the standard first‐order methods with either quadratic or robust norms at the expense of increased noise. HOTS DSC‐PWI optimized for noise and accuracy demonstrated significant advantages over both spiral DSC‐PWI without temporal regularization and traditional echo‐planar DSC‐PWI, improving resolution and mitigating image artifacts associated with long readout, including blurring and geometric distortions. In context of multi‐echo DSC‐PWI, the novel methods allowed ∼4.3× decrease of voxel volume, providing 2× number of TEs compared to the previously published results.Conclusions: Proposed HOTS reconstruction combined with dynamic spiral sampling represents a valid mechanism for improving image quality and resolution of DSC‐PWI significantly beyond those available with established fast imaging techniques.


  • Open Access

    Magnetic Resonance Imaging Findings in Infants with Severe Traumatic Brain Injury and Associations with Abusive Head Trauma

    by Nikki Miller Ferguson, Susan Rebsamen, Aaron S. Field, Jose M. Guerrero, Bedda L. Rosario, Aimee T. Broman, Paul J. Rathouz, Michael J. Bell, Andrew L. Alexander, Peter A. Ferrazzano

    Young children with severe traumatic brain injury (TBI) have frequently been excluded from studies due to age and/or mechanism of injury. Magnetic resonance imaging (MRI) is now frequently being utilized to detect parenchymal injuries and early cerebral edema. We sought to assess MRI findings in infants with severe TBI, and to determine the association between specific MRI findings and mechanisms of injury, including abusive head trauma (AHT). MRI scans performed within the first 30 days after injury were collected and coded according to NIH/NINDS Common Data Elements (CDEs) for Neuroimaging in subjects age < 2 years old with severe TBI enrolled in the Approaches and Decisions in Acute Pediatric Traumatic Brain Injury Trial. Demographics and injury characteristics were analyzed. A total of 81 children were included from ADAPT sites with MRI scans. Median age was 0.77 years and 57% were male. Most common MRI finding was ischemia, present in 57/81 subjects (70%), in a median of 7 brain regions per subject. Contusion 46/81 (57%) and diffuse axonal injury (DAI) 36/81 (44.4%) subjects followed. Children were dichotomized based on likelihood of AHT with 43/81 subjects classified as AHT. Ischemia was found to be significantly associated with AHT (p = 0.001) and “inflicted” injury mechanism (p = 0.0003). In conclusion, the most common intracerebral injury seen on MRI of infants with severe TBI was ischemia, followed by contusion and DAI. Ischemia was associated with AHT, and ischemia affecting > 4 brain regions was predictive of AHT.


  • Open Access

    The Connectomes: Methods of White Matter Tractography and Contributions of Resting State fMRI

    by Jason F. Moody, Nagesh Adluru, Andrew L. Alexander, Aaron S. Field