Lucian Panait
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lucian Panait has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
Robert L. Bell
11 shared publicationsAndrew J. Duffy
10 shared publicationsKurt E. Roberts
9 shared publications- Kurt Eric Roberts
Yale School of Medicine
6 shared publications - Andrew J. Duffy
Department of Surgery, Yale School of Medicine, New Haven, USA
5 shared publications - Stanley J. Dudrick
Department of Surgery, Yale University School of Medicine, 333 Cedar Street, New Haven, CT 06510, USA
5 shared publications
Latest Publications
- 22 June 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (10) , 3801-3810
SAGES Technology and Value Assessment Committee safety and effectiveness analysis on immunofluorescence in the operating room for biliary visualization and perfusion assessment
- 22 June 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (10) , 3801-3810
SAGES Technology and Value Assessment Committee safety and effectiveness analysis on immunofluorescence in the operating room for biliary visualization and perfusion assessment
- 1 January 2015
- Published by Springer Nature
- p. 324-335
Brain-in-the-Loop Learning Using fNIR and Simulated Virtual Reality Surgical Tasks: Hemodynamic and Behavioral Effects
- 1 January 2015
- Published by Springer Nature
- p. 324-335
Brain-in-the-Loop Learning Using fNIR and Simulated Virtual Reality Surgical Tasks: Hemodynamic and Behavioral Effects
- 1 January 2015
- Published by Wolters Kluwer Health in Clinical Liver Disease
- Vol. 5 (1) , 5-7
Single‐incision laparoscopic cholecystectomy
Watch a video presentation of this articleAnswer questions and earn CME
- 1 January 2015
- Published by Wolters Kluwer Health in Clinical Liver Disease
- Vol. 5 (1) , 5-7
Single‐incision laparoscopic cholecystectomy
Watch a video presentation of this articleAnswer questions and earn CME
- Open Access
- 1 January 2015
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 6 (C) , 160-162
Richter-type Spigelian hernia
Introduction: Abdominal wall hernias through the arcuate line termed Spigelian hernias are uncommon. These hernias presenting as a Richter-type, with strangulation of part of the circumference of the bowel wall is very rare. Presentation of case: We report a 27-year-old male patient who presented with a Richter-type Spigelian hernia. Literature review: A MEDLINE literature search of this rare entity yielded six publications presenting Richter-type Spigelian hernias. All of these articles and accompanying references were thoroughly reviewed. There was no gender or anatomical side predominance among the patients. All except our patient presented here were elderly. Pain was the most common symptom and was present in all patients. All patients underwent surgical repair and none reported recurrence of their hernia afterwards. Discussion and conclusion: Richter-type Spigelian hernia is rare and has been reported infrequently in the existing literature. Clinical diagnosis is challenging and CT scan is the diagnostic study of choice. Surgical repair is the definitive treatment and involves primary or mesh repair of the defect as appropriate. Necrotic bowel should be resected and we recommend biologic mesh repair in these cases if the defect is large. Highlights:
- 1 January 2015
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 6 (C) , 160-162
Open AccessRichter-type Spigelian hernia
Introduction: Abdominal wall hernias through the arcuate line termed Spigelian hernias are uncommon. These hernias presenting as a Richter-type, with strangulation of part of the circumference of the bowel wall is very rare. Presentation of case: We report a 27-year-old male patient who presented with a Richter-type Spigelian hernia. Literature review: A MEDLINE literature search of this rare entity yielded six publications presenting Richter-type Spigelian hernias. All of these articles and accompanying references were thoroughly reviewed. There was no gender or anatomical side predominance among the patients. All except our patient presented here were elderly. Pain was the most common symptom and was present in all patients. All patients underwent surgical repair and none reported recurrence of their hernia afterwards. Discussion and conclusion: Richter-type Spigelian hernia is rare and has been reported infrequently in the existing literature. Clinical diagnosis is challenging and CT scan is the diagnostic study of choice. Surgical repair is the definitive treatment and involves primary or mesh repair of the defect as appropriate. Necrotic bowel should be resected and we recommend biologic mesh repair in these cases if the defect is large. Highlights:
- 1 November 2014
- Published by Elsevier in Journal of Surgical Education
- Vol. 71 (6) , e11-e15
A 5-Year Review of Feedback on the Philadelphia-Area Mock ABS Certifying Examination
- 1 November 2014
- Published by Elsevier in Journal of Surgical Education
- Vol. 71 (6) , e11-e15
A 5-Year Review of Feedback on the Philadelphia-Area Mock ABS Certifying Examination
- 1 April 2014
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 259 (4) , 744-749
Complications of Transvaginal Natural Orifice Transluminal Endoscopic Surgery
To review the complications encountered in our facility and in previously published studies of transvaginal (TV) natural orifice transluminal endoscopic surgery (NOTES) to date. TV NOTES is currently observed with critical eyes from the surgical community, despite encouraging data to suggest improved short-term recovery and pain. All TV NOTES procedures performed in female patients between 18 and 65 years of age were included. The median follow-up was 90 days. The TV appendectomies and ventral hernia repairs were pure NOTES, through a SILS port in the vagina, whereas TV cholecystectomies were hybrid procedures with the addition of a 5-mm port in the umbilicus. A total of 102 TV NOTES procedures, including 72 TV cholecystectomies, 24 TV appendectomies, and 6 TV ventral hernia repairs, were performed. The average age was 37 years old and body mass index was 29 kg/m. Three major and 7 minor complications occurred. The first major complication was a rectal injury during a TV access port insertion. The second major complication was an omental vessel bleed after a TV cholecystectomy. The third complication was an intra-abdominal abscess after a TV appendectomy. Seven minor complications were urinary retention (4), transient brachial plexus injury, dislodgement of an intrauterine device, and vaginal granulation tissue. As techniques in TV surgery are adopted, inevitably, complications may occur due to the inherent learning curve. Laparoscopic instruments, although adaptable to TV approaches, have yet to be optimized. A high index of suspicion is necessary to identify complications and optimize outcomes for patients.
- 1 April 2014
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 259 (4) , 744-749
Complications of Transvaginal Natural Orifice Transluminal Endoscopic Surgery
To review the complications encountered in our facility and in previously published studies of transvaginal (TV) natural orifice transluminal endoscopic surgery (NOTES) to date. TV NOTES is currently observed with critical eyes from the surgical community, despite encouraging data to suggest improved short-term recovery and pain. All TV NOTES procedures performed in female patients between 18 and 65 years of age were included. The median follow-up was 90 days. The TV appendectomies and ventral hernia repairs were pure NOTES, through a SILS port in the vagina, whereas TV cholecystectomies were hybrid procedures with the addition of a 5-mm port in the umbilicus. A total of 102 TV NOTES procedures, including 72 TV cholecystectomies, 24 TV appendectomies, and 6 TV ventral hernia repairs, were performed. The average age was 37 years old and body mass index was 29 kg/m. Three major and 7 minor complications occurred. The first major complication was a rectal injury during a TV access port insertion. The second major complication was an omental vessel bleed after a TV cholecystectomy. The third complication was an intra-abdominal abscess after a TV appendectomy. Seven minor complications were urinary retention (4), transient brachial plexus injury, dislodgement of an intrauterine device, and vaginal granulation tissue. As techniques in TV surgery are adopted, inevitably, complications may occur due to the inherent learning curve. Laparoscopic instruments, although adaptable to TV approaches, have yet to be optimized. A high index of suspicion is necessary to identify complications and optimize outcomes for patients.
- Open Access
- 12 March 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 28 (8) , 2443-51
A comparison of NOTES transvaginal and laparoscopic cholecystectomy procedures based upon task analysis.
- 12 March 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 28 (8) , 2443-51
Open AccessA comparison of NOTES transvaginal and laparoscopic cholecystectomy procedures based upon task analysis.
- 1 March 2014
- Published by Elsevier in Journal of Surgical Research
- Vol. 187 (1) , 53-58
Do laparoscopic skills transfer to robotic surgery?
- 1 March 2014
- Published by Elsevier in Journal of Surgical Research
- Vol. 187 (1) , 53-58
Do laparoscopic skills transfer to robotic surgery?
- 15 August 2013
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 8 (2) , 105-109
Role of robotic-assisted surgery in benign esophageal diseases
- 15 August 2013
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 8 (2) , 105-109
Role of robotic-assisted surgery in benign esophageal diseases
- 30 July 2013
- Published by SAGE Publications in Surgical Innovation
- Vol. 21 (2) , 130-136
Pure Transvaginal Ventral Hernia Repair in Humans
Introduction. Transvaginal natural orifice transluminal endoscopic surgery procedures are at the forefront of minimally invasive innovation, remarkable for shorter recovery times and decreased postoperative pain. We aim to demonstrate a novel technique of pure transvaginal laparoscopic ventral hernia repair in a series of patients performed in our institution. Technique Description. The patient was placed in lithotomy position and steep Trendelenburg. A 2-cm transverse colpotomy incision was made and a SILS port was introduced. One 12-mm trocar and two 5-mm trocars were placed through the SILS port and standard straight laparoscopic instruments were used. An appropriately sized round mesh was deployed within a specimen retrieval bag into the peritoneal cavity. Complete anterior circumferential fixation of the mesh was achieved using an AbsorbaTack device. The colpotomy incision was closed. Results. There were a total of 6 pure transvaginal ventral hernia repair procedures performed in our institution between November 2010 and February 2012. The first case was converted to an open procedure after a rectal injury was recognized and repaired. Two patients had transient urinary retention that resolved after 24 hours. One patient had vaginal wound granulation noted at 2 months postoperatively. No long-term complications or recurrences were noted with a median follow-up of 9 months. The mean operative time was 107 minutes. Conclusion. Our initial experience with transvaginal ventral hernia repair in humans suggests that this procedure is feasible, safe, and associated with improved cosmetic results.
- 30 July 2013
- Published by SAGE Publications in Surgical Innovation
- Vol. 21 (2) , 130-136
Pure Transvaginal Ventral Hernia Repair in Humans
Introduction. Transvaginal natural orifice transluminal endoscopic surgery procedures are at the forefront of minimally invasive innovation, remarkable for shorter recovery times and decreased postoperative pain. We aim to demonstrate a novel technique of pure transvaginal laparoscopic ventral hernia repair in a series of patients performed in our institution. Technique Description. The patient was placed in lithotomy position and steep Trendelenburg. A 2-cm transverse colpotomy incision was made and a SILS port was introduced. One 12-mm trocar and two 5-mm trocars were placed through the SILS port and standard straight laparoscopic instruments were used. An appropriately sized round mesh was deployed within a specimen retrieval bag into the peritoneal cavity. Complete anterior circumferential fixation of the mesh was achieved using an AbsorbaTack device. The colpotomy incision was closed. Results. There were a total of 6 pure transvaginal ventral hernia repair procedures performed in our institution between November 2010 and February 2012. The first case was converted to an open procedure after a rectal injury was recognized and repaired. Two patients had transient urinary retention that resolved after 24 hours. One patient had vaginal wound granulation noted at 2 months postoperatively. No long-term complications or recurrences were noted with a median follow-up of 9 months. The mean operative time was 107 minutes. Conclusion. Our initial experience with transvaginal ventral hernia repair in humans suggests that this procedure is feasible, safe, and associated with improved cosmetic results.