Ilknur Durukan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ilknur Durukan has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Barış Yıldız
Department of Environmental Engineering, Hacettepe University, 06800 Ankara, Turkiye
6 shared publications - Çiğdem Arpa
Chemistry Department, Hacettepe University, Ankara, Turkey
5 shared publications - Koray Alper
Zonguldak Bülent Ecevit Üniversitesi
3 shared publications - Kubilay Tekin
Karabuk University
3 shared publications - Selhan Karagöz
Karabuk University
2 shared publications Sema Bektaş
2 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Elsevier in Current Research in Green and Sustainable Chemistry
- Vol. 13
Toward zero-waste valorisation of pistachio shells via hydrothermal carbonisation and pyrolysis
- 29 October 2026
- Published by Elsevier in Current Research in Green and Sustainable Chemistry
- Vol. 13
Open AccessToward zero-waste valorisation of pistachio shells via hydrothermal carbonisation and pyrolysis
- Open Access
- 30 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11629
Preconcentration of Silver from Real Mine Wastes Using Deep Eutectic Solvent-Assisted Solidified Floating Organic Drop Microextraction and Determination by Flame Atomic Absorption Spectrometry
Silver, a critical element in various technological and industrial sectors, is increasingly being targeted for recovery from secondary sources due to the depletion of primary reserves and the environmental impacts of traditional mining. This study presents the development and application of a novel, environmentally friendly analytical method for the preconcentration and determination of silver in mining waste using deep eutectic solvents (DES) in combination with solidified floating organic drop microextraction (SFODME) and flame atomic absorption spectrometry (FAAS). Analytical performance was evaluated in terms of linearity (7.5–200 µg/L, R2 > 0.995), enhancement factor (27.9), limit of detection (2.1 µg/L), and precision (RSD ± 2.32%, n = 8). The method’s validity was further validated through interference studies, analysis of certified reference materials (recovery rates: 80–93%), and application to real mining waste and tailings collected from gold-silver mining operations in Turkey’s Aegean region. Results confirm the method’s applicability for trace-level silver analysis in complex matrices, offering significant advantages in terms of sustainability, cost-effectiveness, and analytical reliability, aligned with the principles of green chemistry and resource recovery.
- 30 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11629
Open AccessPreconcentration of Silver from Real Mine Wastes Using Deep Eutectic Solvent-Assisted Solidified Floating Organic Drop Microextraction and Determination by Flame Atomic Absorption Spectrometry
Silver, a critical element in various technological and industrial sectors, is increasingly being targeted for recovery from secondary sources due to the depletion of primary reserves and the environmental impacts of traditional mining. This study presents the development and application of a novel, environmentally friendly analytical method for the preconcentration and determination of silver in mining waste using deep eutectic solvents (DES) in combination with solidified floating organic drop microextraction (SFODME) and flame atomic absorption spectrometry (FAAS). Analytical performance was evaluated in terms of linearity (7.5–200 µg/L, R2 > 0.995), enhancement factor (27.9), limit of detection (2.1 µg/L), and precision (RSD ± 2.32%, n = 8). The method’s validity was further validated through interference studies, analysis of certified reference materials (recovery rates: 80–93%), and application to real mining waste and tailings collected from gold-silver mining operations in Turkey’s Aegean region. Results confirm the method’s applicability for trace-level silver analysis in complex matrices, offering significant advantages in terms of sustainability, cost-effectiveness, and analytical reliability, aligned with the principles of green chemistry and resource recovery.
- 1 May 2025
- Published by Elsevier in Journal of the Energy Institute
- Vol. 120
Effect of process variables on hydrothermal carbonization of food waste
- 1 May 2025
- Published by Elsevier in Journal of the Energy Institute
- Vol. 120
Effect of process variables on hydrothermal carbonization of food waste
- Open Access
Preconcentration of Gold from Mining Waste Samples Using the Solidified Floating Organic Drop Microextraction and Determination by Flow Injection–Flame Atomic Absorption Spectrometry
The increasing demand for gold necessitates the development of sustainable and environmentally friendly recovery methods, particularly from mining waste. In this study, trace and ultra-trace levels of gold ions were preconcentrated using solidified floating organic drop microextraction (SFODME) and quantified by flow injection–flame atomic absorption spectrometry (FI-FAAS). Sodium diethyldithiocarbamate was used as the chelating agent. Key parameters, including the pH, buffer volume, complexing agent concentration, salt effect, extraction time, stirring speed, temperature, and final volume, were optimized using univariate analysis, yielding an enhancement factor of 42.6. The method demonstrated linearity between 20 and 450 µg/L, with limits of detection and a quantification of 5.03 µg/L and 16.76 µg/L, respectively. In order to evaluate the applicability and reliability of the developed method, the method was applied to certified reference samples (Rocklabs CRM SE114, OREAS CRM 61 f, OREAS CRM 231, and OREAS CRM 235) and real mining samples (mining waste samples from an open pit gold–silver mine in the Aegean Region and tailing samples from an underground gold–silver mine in the Aegean Region) after the real sample preparation procedure. The method was further evaluated for the environmental impact using the Analytic GREEnness (AGREE) metric, based on the 12 principles of green chemistry.
Open AccessPreconcentration of Gold from Mining Waste Samples Using the Solidified Floating Organic Drop Microextraction and Determination by Flow Injection–Flame Atomic Absorption Spectrometry
The increasing demand for gold necessitates the development of sustainable and environmentally friendly recovery methods, particularly from mining waste. In this study, trace and ultra-trace levels of gold ions were preconcentrated using solidified floating organic drop microextraction (SFODME) and quantified by flow injection–flame atomic absorption spectrometry (FI-FAAS). Sodium diethyldithiocarbamate was used as the chelating agent. Key parameters, including the pH, buffer volume, complexing agent concentration, salt effect, extraction time, stirring speed, temperature, and final volume, were optimized using univariate analysis, yielding an enhancement factor of 42.6. The method demonstrated linearity between 20 and 450 µg/L, with limits of detection and a quantification of 5.03 µg/L and 16.76 µg/L, respectively. In order to evaluate the applicability and reliability of the developed method, the method was applied to certified reference samples (Rocklabs CRM SE114, OREAS CRM 61 f, OREAS CRM 231, and OREAS CRM 235) and real mining samples (mining waste samples from an open pit gold–silver mine in the Aegean Region and tailing samples from an underground gold–silver mine in the Aegean Region) after the real sample preparation procedure. The method was further evaluated for the environmental impact using the Analytic GREEnness (AGREE) metric, based on the 12 principles of green chemistry.
- 30 December 2024
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 197 (1) , 1-11
Preconcentration of bismuth using nickel hydroxide nanoflower from water samples and determination by FAAS
In this study, a preconcentration strategy based on Ni(OH)2 nanoflowers (NFs) was developed for the extraction/separation of bismuth ions from environmental water samples before the determination by flame atomic absorption spectrometry (FAAS). The homogeneous coprecipitation method was employed for the synthesis of the flower-shaped Ni(OH)2 and used as an adsorbent for the preconcentration of bismuth. The extraction variables were determined by a univariate optimization strategy to obtain maximum extraction performance. The optimal parameters of the method were as follows: 15 min mechanical shaking at 120 rpm, pH 6.0 buffer solution (1.0 mL), 20 mg of sorbent, and 250 µL of 6.0 M nitric acid for the elution. Under the optimized instrumental and extraction conditions, LOD (limit of detection), LOQ (limit of quantitation), and linear dynamic range were determined as 2.8 µg/L, 9.4 µg/L, and 0.010–0.30 mg/L, respectively. The enhancement factor of the sorbent-based method was calculated as 139.1-folds by comparing the slopes of calibration plots obtained from FAAS and the preconcentration method. To assess the feasibility and reliability of the developed method, tap water and spring water samples were analyzed under optimized conditions. The satisfactory %recoveries were obtained close to 100% using the direct comparison method. The obtained results show that the presented method is a promising candidate for efficient extraction and trace determination of bismuth in several sample mediums.
- 30 December 2024
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 197 (1) , 1-11
Preconcentration of bismuth using nickel hydroxide nanoflower from water samples and determination by FAAS
In this study, a preconcentration strategy based on Ni(OH)2 nanoflowers (NFs) was developed for the extraction/separation of bismuth ions from environmental water samples before the determination by flame atomic absorption spectrometry (FAAS). The homogeneous coprecipitation method was employed for the synthesis of the flower-shaped Ni(OH)2 and used as an adsorbent for the preconcentration of bismuth. The extraction variables were determined by a univariate optimization strategy to obtain maximum extraction performance. The optimal parameters of the method were as follows: 15 min mechanical shaking at 120 rpm, pH 6.0 buffer solution (1.0 mL), 20 mg of sorbent, and 250 µL of 6.0 M nitric acid for the elution. Under the optimized instrumental and extraction conditions, LOD (limit of detection), LOQ (limit of quantitation), and linear dynamic range were determined as 2.8 µg/L, 9.4 µg/L, and 0.010–0.30 mg/L, respectively. The enhancement factor of the sorbent-based method was calculated as 139.1-folds by comparing the slopes of calibration plots obtained from FAAS and the preconcentration method. To assess the feasibility and reliability of the developed method, tap water and spring water samples were analyzed under optimized conditions. The satisfactory %recoveries were obtained close to 100% using the direct comparison method. The obtained results show that the presented method is a promising candidate for efficient extraction and trace determination of bismuth in several sample mediums.
- 11 December 2024
- Published by Taylor & Francis in Analytical Letters
- Vol. 58 (16) , 2788-2805
Green Surfactant Assisted-Solidified Floating Organic Drop Micro-Extraction for the Preconcentration of Trace Cobalt and Determination by Flame Atomic Absorption Spectrometry
- 11 December 2024
- Published by Taylor & Francis in Analytical Letters
- Vol. 58 (16) , 2788-2805
Green Surfactant Assisted-Solidified Floating Organic Drop Micro-Extraction for the Preconcentration of Trace Cobalt and Determination by Flame Atomic Absorption Spectrometry
- Open Access
Ionic Liquid—Solidified Floating Organic Drop Microextraction for the Preconcentration of Lead in Environmental Water Samples Prior to Its Determination with Electrothermal Atomic Absorption Spectrometry
This research investigates the utilization of an ionic liquid combination of solidified floating organic drop micro-extraction (IL-SFODME) to augment the concentration of trace amounts of lead, working as a preliminary stage before electrothermal atomic absorption spectrometry (ETAAS) analysis without the use of chelating agents. Key parameters impacting the microextraction efficiency—including pH, the volume of the ionic liquid (1-Hexyl-3-methylimidazolium hexafluorophosphate, HMIMPF6), temperature, extraction time, and stirring speed—were methodically examined to determine optimal conditions. Under detected optimized conditions, an enhancement factor of 71.2 was obtained for a 15 mL sample solution. The calibration curve exhibited linearity within the concentration range of 0.2–2.5 µg/L, with a detection limit (3σ) of 0.054 µg/L and a quantification limit (10σ) of 0.18 µg/L. For seven replicate measurements of 0.5 µg/L lead, the relative standard deviation (RSD) was ±2.30%. This method was effectively implemented to extract and quantify lead in both reference water and different real water samples, showcasing significantly efficient extraction performance.
Open AccessIonic Liquid—Solidified Floating Organic Drop Microextraction for the Preconcentration of Lead in Environmental Water Samples Prior to Its Determination with Electrothermal Atomic Absorption Spectrometry
This research investigates the utilization of an ionic liquid combination of solidified floating organic drop micro-extraction (IL-SFODME) to augment the concentration of trace amounts of lead, working as a preliminary stage before electrothermal atomic absorption spectrometry (ETAAS) analysis without the use of chelating agents. Key parameters impacting the microextraction efficiency—including pH, the volume of the ionic liquid (1-Hexyl-3-methylimidazolium hexafluorophosphate, HMIMPF6), temperature, extraction time, and stirring speed—were methodically examined to determine optimal conditions. Under detected optimized conditions, an enhancement factor of 71.2 was obtained for a 15 mL sample solution. The calibration curve exhibited linearity within the concentration range of 0.2–2.5 µg/L, with a detection limit (3σ) of 0.054 µg/L and a quantification limit (10σ) of 0.18 µg/L. For seven replicate measurements of 0.5 µg/L lead, the relative standard deviation (RSD) was ±2.30%. This method was effectively implemented to extract and quantify lead in both reference water and different real water samples, showcasing significantly efficient extraction performance.
- Open Access
- 2 August 2024
- Published by Springer Nature in Research Square
Green surfactant assisted-solidified floating organic drop micro-extraction (SA-SFODME) for the preconcentration of trace cobalt and determination by flame atomic absorption spectrometry (FAAS)
This study focuses on refining the solidified floating organic drop microextraction (SFODME) without using chelating agent technique for enhancing the preconcentration of trace cobalt levels. The cobalt ion formed a hydrophobic complex with the help of the anionic surfactant sodium dodecyl benzene sulfonate (SDBS), and this hydrophobic complex was extracted into the 1-dodecanol drop. This serves as a preliminary step for subsequent analysis using flame atomic absorption spectrometry (FAAS). Several factors influencing microextraction efficiency, such as pH, sodium dodecylbenzenesulfonate (SDBS) concentration, extraction time, stirring rate, and temperature, were systematically investigated to determine optimal conditions. Under these optimized parameters, an enhancement factor of 80 was achieved for a 25 mL sample solution. The calibration curve displayed linearity within the 0.01–0.075 mg/L range, with a limit of detection (3s) of 2.8 µg/L and a limit of quantification (10s) of 9.3 µg/L. The relative standard deviation (RSD) for 10 replicate measurements of 10 µg/L cobalt was 2.1%. The method was successfully applied to extract and determine cobalt in reference water samples and various real water samples, showing notably high extraction yields.
- 2 August 2024
- Published by Springer Nature in Research Square
Open AccessGreen surfactant assisted-solidified floating organic drop micro-extraction (SA-SFODME) for the preconcentration of trace cobalt and determination by flame atomic absorption spectrometry (FAAS)
This study focuses on refining the solidified floating organic drop microextraction (SFODME) without using chelating agent technique for enhancing the preconcentration of trace cobalt levels. The cobalt ion formed a hydrophobic complex with the help of the anionic surfactant sodium dodecyl benzene sulfonate (SDBS), and this hydrophobic complex was extracted into the 1-dodecanol drop. This serves as a preliminary step for subsequent analysis using flame atomic absorption spectrometry (FAAS). Several factors influencing microextraction efficiency, such as pH, sodium dodecylbenzenesulfonate (SDBS) concentration, extraction time, stirring rate, and temperature, were systematically investigated to determine optimal conditions. Under these optimized parameters, an enhancement factor of 80 was achieved for a 25 mL sample solution. The calibration curve displayed linearity within the 0.01–0.075 mg/L range, with a limit of detection (3s) of 2.8 µg/L and a limit of quantification (10s) of 9.3 µg/L. The relative standard deviation (RSD) for 10 replicate measurements of 10 µg/L cobalt was 2.1%. The method was successfully applied to extract and determine cobalt in reference water samples and various real water samples, showing notably high extraction yields.
- Open Access
- 18 July 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (14) , 6268
Ionic Liquid-Based Solidified Floating Organic Drop Micro-Extraction Followed by Graphite Furnace Atomic Absorption Spectrometry for the Determination of Mercury in Water Samples
This study aims to apply the ionic liquid-based solidified floating organic drop micro-extraction (IL-SFODME) technique to improve the preconcentration of trace mercury levels, serving as a preparatory step for analysis via graphite furnace atomic absorption spectrometry (GFAAS) without using chelating agents. The process involves separating and preconcentrating mercury ions using IL-SFODME, followed by GFAAS analysis. This study systematically examined several factors affecting micro-extraction efficiency, including pH, the amount of ionic liquid 1-Hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF6), extraction time, stirring rate, and temperature, to determine the optimal conditions. Under these optimized conditions, an enhancement factor of 171 was achieved for a 75 mL sample solution. The calibration curve was linear within the 0.5–10 µg/L range, with a detection limit (3σ) of 0.12 µg/L and a quantification limit (10σ) of 0.40 µg/L. The relative standard deviation (RSD) for 7 replicate measurements of 1 µg/L mercury was ±2.78%. The combination of the ionic liquid and SFODME methods without using a chelating agent is used for the first time for metal extraction. The method was successfully applied to extract and determine mercury in reference water samples and various real water samples, demonstrating notably satisfactory extraction efficiency.
- 18 July 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (14) , 6268
Open AccessIonic Liquid-Based Solidified Floating Organic Drop Micro-Extraction Followed by Graphite Furnace Atomic Absorption Spectrometry for the Determination of Mercury in Water Samples
This study aims to apply the ionic liquid-based solidified floating organic drop micro-extraction (IL-SFODME) technique to improve the preconcentration of trace mercury levels, serving as a preparatory step for analysis via graphite furnace atomic absorption spectrometry (GFAAS) without using chelating agents. The process involves separating and preconcentrating mercury ions using IL-SFODME, followed by GFAAS analysis. This study systematically examined several factors affecting micro-extraction efficiency, including pH, the amount of ionic liquid 1-Hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF6), extraction time, stirring rate, and temperature, to determine the optimal conditions. Under these optimized conditions, an enhancement factor of 171 was achieved for a 75 mL sample solution. The calibration curve was linear within the 0.5–10 µg/L range, with a detection limit (3σ) of 0.12 µg/L and a quantification limit (10σ) of 0.40 µg/L. The relative standard deviation (RSD) for 7 replicate measurements of 1 µg/L mercury was ±2.78%. The combination of the ionic liquid and SFODME methods without using a chelating agent is used for the first time for metal extraction. The method was successfully applied to extract and determine mercury in reference water samples and various real water samples, demonstrating notably satisfactory extraction efficiency.