Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Khaled Tarabieh has a total of 88 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sustainable Tactile Materials to Enhance Accessibility for Visually Impaired

    by Karim Abdelkoudos, Hassan Afifi, Mohamed El-Raffa, Hassan El Kassas, Zenah Helmy, Shawky Khoury, Reem Gamal, Maram Saudy, Khalid Nassar, Khaled Tarabieh, et al.

  • Open Access

    Energy Retrofit Decision-Support System for Existing Educational Buildings in Egypt

    by Rania ElTahan, Ossama Hosny, Khaled Tarabieh, Elkhayam M. Dorra, Sara Elamawy

    Existing buildings consume a large portion of the total current energy production, especially in developing countries such as Egypt. Increasing energy demand, coupled with decreasing availability and increasing cost of conventional non-renewable energy resources, have encouraged a “building green” retrofit trend in order to maximize the energy performance of the built environment. This paper outlines the development of an Energy Retrofit Decision-Support System (ERDSS) for hot, arid climates that models building retrofit scenarios and determines the impact of each retrofit measure on the overall energy consumption of a proposed building retrofit program. The methodology combines building an energy simulation with a database-driven, budget-constrained optimization framework based on the Savings-to-Investment Ratio (SIR) to evaluate and prioritize retrofit measures. In addition, ERDSS determines the impact of each retrofit measure on the overall energy consumption of a proposed building retrofit program, ranks the retrofit measures according to their Savings-to-Investment Ratio (SIR) and uses optimization to develop a suggested retrofit program for a given budget. ERDSS is applied on a case study of an education building in New Cairo, Egypt, in order to illustrate the performance of the framework. Results show that savings for the commissioned retrofit, standard retrofits, and deep retrofits reached 15 percent, 35 percent, and 45 percent, respectively.


  • Open Access

    Utilizing Cob–Earth and Sand-Filled Plastic Bottles to Address Environmental Challenges: A Sustainable Construction Solution

    by Mayar Khairy, Zeinab Ahmed, Ahmed Abodonya, Omar Ahmed El Kadi, Khaled Tarabieh, Khaled Nassar, Ezzeldin Yazeed Sayed-Ahmed

    The construction industry is a major contributor to global carbon emissions, primarily due to its reliance on cement-based materials. Simultaneously, plastic bottle waste presents a significant environmental challenge. This study aims to address both issues by exploring the integration of plastic bottle waste into cob–earth materials as a sustainable alternative to traditional concrete modules. The research involves testing various mixes with plastic bottles arranged in different patterns to assess their load-bearing capacity and distribution. The cob mix with bottles arranged in a modified pattern demonstrated the highest load resistance, bearing over 47.1 kN, making it suitable for prototype development. The study also investigates the potential of using cob as an exterior finishing layer, reducing the need for cement. The results show that using local earth materials significantly lowers embodied carbon, offering a more sustainable construction solution. This approach helps mitigate plastic waste and supports climate resilience by promoting low-carbon, locally sourced materials, aligning with Egypt’s national sustainability commitments.

  • Indoor Air Quality Monitoring in Learning Spaces: A Case Study in Cairo, Egypt

    by Farah Shoukry, Sherif Goubran, Ahmed Marey, Khaled Tarabieh

  • Open Access

    Anticipating Emerging Research Frontiers Related to Indoor Air Quality: What Did We Learn from the COVID-19 Pandemic?

    by Farah Shoukry, Sherif Goubran, Khaled Tarabieh

    Background: While the COVID-19 pandemic has officially ended, it remains a significant era that profoundly tests humanity’s ability to solve challenges across various domains related to health hazards’ crisis management, technological innovation, and requestioning the management of Indoor Air Quality (IAQ) in different building typologies. Methods: This study examines early publications related to IAQ during the early phase of the pandemic, from March 2020 to August 2021, to identify thematic research areas anticipated to shape the scientific community’s future interests for at least the following 10 years. This study proposes an analytical framework to further interpret the identified thematic areas of research related to IAQ based on intentionality and impact. Results: Topics included the spatial design of indoor environments, occupants’ health, thermal comfort, building performance and ventilation, technology use and energy efficiency, as well as health and social equity. The authors commented on key topics requiring immediate attention from architects, building operators, and researchers. Conclusions: This review foresees the need for (1) building codes that balance spatial design and health aspects to reduce the rate of viral transmission, (2) carbon footprint reduction plans in response to IAQ ventilation requirements, and (3) ventilation systems that consider the thermal comfort of occupants, minimize energy losses, and safeguard air quality from external pollutants. Finally, (4) find a balance between the identified parameters to enhance the IAQ system control.


  • Open Access

    Thermal and Structural Performances of Screen Grid Insulated Concrete Forms (SGICFs) Using Experimental Testing

    by Yosra El-Maghraby, Khaled Tarabieh, Meral Sharkass, Islam Mashaly, Ezzat Fahmy

    The demand for sustainable building materials and systems with the emphasis on energy efficiency is on the rise. Insulating Concrete Forms (ICFs) are an example of such structural systems. Screen Grid Insulated Concrete Forms (SGICFs) are an innovative system that combines structural strength and thermal performance. ICF walls are commonly used in Western countries to provide high-level insulation and internal weather control. Accordingly, the current research conducts a comparative thermal analysis for a market-supplied ICF wall, a SGICF proposed design, and three typical brick walls used regionally in the Middle East. The heat transfer through the five walls is simulated by COMSOL Multiphysics and validated experimentally by utilizing a guarded hot box facility under the regulations of the ASTM C1363 standard. The market-supplied ICF walls showed better thermal insulation properties than the proposed SGICF walls, because of their higher thermal mass of concrete than in the SGICF walls. However, both walls had a remarkably higher insulation performance than the other three typical brick walls available in the market. The results reveal that the market-supplied ICF walls are overdesigned for use in the Middle East region, and SGICFs, with their comparative thermal transmittance, are a very good competitor in the Middle East market.


  • Open Access

    Enhanced Indoor Air Quality Dashboard Framework and Index for Higher Educational Institutions

    by Farah Shoukry, Sherif Goubran, Khaled Tarabieh

    This research proposes a 10-step methodology for developing an enhanced IAQ dashboard and classroom index (CI) in higher educational facilities located in arid environments. The identified parameters of the enhanced IAQ dashboard–inspired by the pandemic experience, result from the literature review and the outcome of two electronic surveys of (52) respondents, including health professionals and facility management experts. On the other hand, the indicators included in the CI are based on (80) occupant survey responses, including parameters related to IAQ, Indoor Environmental Quality (IEQ), and thermal comfort, amongst other classroom operative considerations. The CI is further tested in four learning spaces at the American University in Cairo, Egypt. The main contribution of this research is to suggest a conceptual visualization of the dashboard and a practical classroom index that integrates a representative number of contextual indicators to recommend optimal IAQ scenarios for a given educational facility. This study concludes by highlighting several key findings: (1) both qualitative and quantitative metrics are necessary to capture indoor air quality-related parameters accurately; (2) tailoring the dashboard as well as the CI to specific contexts enhances its applicability across diverse locations; and finally, (3) the IAQ dashboard and CI offer flexibility for ad-hoc applications.


  • Open Access

    Indoor Air Quality and Ventilation Energy in University Classrooms: Simplified Model to Predict Trade-Offs and Synergies

    by Farah Shoukry, Rana Raafat, Khaled Tarabieh, Sherif Goubran

    Students and educators spend significant time in learning spaces on university campuses. Energy efficiency has become a concern among facility managers, given the need to maintain acceptable indoor air quality (IAQ) levels during and after the COVID-19 pandemic. This paper investigates the relationship between control and extraneous variables in a university classroom’s total mechanical ventilation (kWh). The model is built using Grasshopper software on Rhino Version 7. Our methodology encompasses (1) an extensive review of recent trends for studying IAQ and energy, (2) selecting parameters for simulation, (3) model configuration on Grasshopper, and finally, (4) a formulation of a pertinent equation to consolidate the relationship between the studied factors and the total mechanical ventilation energy (kWh). Central to this study are two key research questions: (1) What correlations exist between various parameters related to occupancy and IAQ in educational spaces? And (2) how can we optimize energy efficiency in university classrooms? The main contribution of this research is a generated equation representing the annual mechanical ventilation energy consumption based on selected parameters of classroom height, area, occupancy, window location, and ventilation rate of HVAC systems. We find that occupancy and class volume are the two most influential factors directly affecting mechanical ventilation energy consumption. The equation serves as a valuable estimation tool for facility managers, designers, and campus operations to investigate how fluctuations in occupancy can influence ventilation energy consumption in the physical attributes of a university classroom. This enables proactive decision-making, optimizing energy efficiency and resource allocation in real-time to promote sustainable and cost-effective campus operations.