MMMichela De Muri

Michela De Muri

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michela De Muri has a total of 228 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Spatially resolved diagnostics for optimization of large ion beam sources

    by G. Serianni, E. Sartori, R. Agnello, P. Agostinetti, M. Agostini, M. Barbisan, M. Brombin, V. Candeloro, M. Dalla Palma, R. Delogu, et al.

    Giant negative ion sources for neutral beam injectors deliver huge negative ion currents, thanks to their multi-beamlet configuration. As the single-beamlet optics defines the transmission losses along the beamline, the extraction of a similar current for all beamlets is extremely desirable, in order to facilitate the beam source operation (i.e., around perveance match). This Review investigates the correlation between the vertical profile of beam intensity and the vertical profiles of plasma properties at the extraction region of the source, focusing on the influence of increasing cesium injection. Only by the combined use of all available source diagnostics, described in this Review, can beam features on the scale of the non-uniformities be investigated with a sufficient space resolution. At RF power of 50 kW/driver, with intermediate bias currents and a filter field of 2.4 mT, it is found that the central part of the four vertical beam segments exhibits comparable plasma density and beamlet currents; at the edges of the central segments, both the beam and electron density appear to decrease (probably maintaining fixed electron-to-ion ratio); at the bottom of the source, an increase of cesium injection can compensate for the vertical drifts that cause a much higher presence of electrons and a lower amount of negative ions.


  • On the road to ITER NBIs: SPIDER improvement after first operation and MITICA construction progress

    by V. Toigo, D. Marcuzzi, G. Serianni, M. Boldrin, G. Chitarin, S. Dal Bello, L. Grando, A. Luchetta, R. Pasqualotto, P. Zaccaria, et al.


  • SPIDER Cs Ovens functional tests

    by M. De Muri, A. Rizzolo, E. Sartori, S. Cristofaro, M. Barbisan, M. Fadone, D. Ravarotto, R. Rizzieri, R. Capobianco, P. Cinetto, et al.


  • Open Access

    First operation in SPIDER and the path to complete MITICA

    by G. Serianni, V. Toigo, M. Bigi, M. Boldrin, G. Chitarin, S. Dal Bello, L. Grando, A. Luchetta, D. Marcuzzi, R. Pasqualotto, et al.

    The requirements of ITER neutral beam injectors (1 MeV, 40 A negative deuterium ion current for 1 h) have never been simultaneously attained; therefore, a dedicated Neutral Beam Test Facility (NBTF) was set up at Consorzio RFX (Padova, Italy). The NBTF includes two experiments: SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma), the full-scale prototype of the source of ITER injectors, with a 100 keV accelerator, to investigate and optimize the properties of the ion source; and MITICA, the full-scale prototype of the entire injector, devoted to the issues related to the accelerator, including voltage holding at low gas pressure. The present paper gives an account of the status of the procurements, of the timeline, and of the voltage holding tests and experiments for MITICA. As for SPIDER, the first year of operation is described, regarding the solution of some issues connected with the radiofrequency power, the source operation, and the characterization of the first negative ion beam.


  • Interpreting the dynamic equilibrium during evaporation in a cesium environment

    by M. Fadone, M. Barbisan, S. Cristofaro, M. De Muri, G. Serianni, E. Sartori

    The cesium ovens for the prototype source of the ITER neutral beam injectors are currently tested in the CAesium Test Stand (CATS) facility, with a background pressure of 10−6 mbar. Different diagnostics are here installed: two Langmuir–Taylor detectors allow us to determine the Cs vapour evaporation rate from the oven and the Cs density at different positions in the vacuum chamber; and laser absorption spectroscopy is used to measure the density integrated over a line of sight and a quartz crystal microbalance to detect the cesium mass deposited in time over a surface. In this paper, we present a model to describe the dynamic equilibrium in the evaporation chamber of CATS with the first oven tested in order to gain information about the Cs sticking coefficient at the walls. The model hence includes sticking and energy accommodation of the Cs atoms to the walls, calculates the flux density at the surfaces, and provides the Cs atom density at any location in the volume. By this model, we simulate the Cs evaporation and the equilibrium density, comparing the modeled results with the experimental data. As a result, a sticking coefficient of 2% is obtained.


  • Open Access

    Beam and installation improvements of the NIO1 ion source

    by M. Cavenago, M. Barbisan, R. Delogu, A. Pimazzoni, C. Poggi, M. Ugoletti, M. Agostini, V. Antoni, C. Baltador, V. Cervaro, et al.

    The NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component Bx has been progressively extended to span the −12 to 5 mT range, and as a trend, source performances improved with |Bx|. The progress of camera beam diagnostics and of the quality of the volume-produced H− beam is also shown. The status, off-line results, and reliability of a first NIO1 cesium oven are discussed; other upgrades in preparation (cavity ring down spectrometer, the end calorimeter, and conceptual tests of the energy recovery system) are also listed.


  • Open Access

    Design and comparison of the Cs ovens for the test facilities ELISE and SPIDER

    by Sofia Cristofaro, Markus Fröschle, Alessandro Mimo, Andrea Rizzolo, Michela De Muri, Marco Barbisan, Ursel Fantz

    Negative ion sources for fusion rely on the formation of negative hydrogen (or deuterium) ions by conversion of atomic hydrogen and positive hydrogen ions at a low work function caesiated surface. Cs is thus evaporated into the source to decrease the surface work function, which may change due to the removal and redistribution of Cs during plasma phases. To maintain a temporarily stable low work function during 1 h plasma, continuous evaporation of caesium is required, and this is performed by temperature controlled Cs ovens. The Cs ovens for ELISE (IPP Garching) and SPIDER (Consorzio RFX) are based on the evaporation of liquid Cs from a reservoir located at one end of the oven, which is controlled by the reservoir temperature. The ampoule Cs oven of ELISE is in operation since 2015, allowing for controllable and stable evaporation. The SPIDER oven is based on the ELISE oven although it required significant changes due to the vacuum environment and the oven location (at the back-plate instead of the sidewalls), leading to a different design of the oven and the nozzle. First investigations on the SPIDER oven in a dedicated test stand show that Cs evaporation is controllable, stable, and reproducible.


  • Experimental experience and improvement of NIO1 H− ion source

    by M. Cavenago, G. Serianni, C. Baltador, M. Barbisan, M. De Muri, A. Pimazzoni, C. Poggi, P. Veltri, D. Aprile, V. Antoni, et al.


  • Design and specifications of the diagnostics for the instrumented calorimeter of Source for the Production of Ions of Deuterium Extracted from Radio frequency plasma

    by M. De Muri, M. Dalla Palma, D. Fasolo, R. Pasqualotto, N. Pomaro, A. Rizzolo, G. Serianni, M. Tollin

    In the development of the neutral beam injector for ITER experiment, the test facility SPIDER is going to be built. To measure the beam parameters, several diagnostics are used. One of them is the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE) which measures beam uniformity, beamlet divergence, and stripping losses. This contribution gives an overview of the diagnostics dedicated to these measurements: thermal cameras, thermocouples, current sensors, and electrostatic sensors. The specifications of these diagnostics have been defined according to the results of electrostatic and thermal simulations. A failure modes and effects analysis has been performed during the design. Consequently the project of the STRIKE diagnostics has been optimized to reduce the possible failure risks.