Antonio C. L. Conceição
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Antonio C. L. Conceição has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Elsa M. Gonçalves
Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1649-016 Lisboa, Portugal
2 shared publications - José Luis Capelo
OMICS & Analytical Development and BIOSCOPE Research Group, LAQV REQUIMTE, Chemistry Department, NOVA School of Science and Technology, NOVA FCT, Portugal
2 shared publications - Manuel E. Minas da Piedade
Universidade de Lisboa Campo Grande
2 shared publications - Raquel Rial Otero
Nutrition and Bromatology Group, Analytical and Food Chemistry Department, University of Vigo, Ourense Campus, E-32004 Ourense, SPAIN
2 shared publications A. Correia
REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica, Portugal
1 shared publication- Abhinav Joseph
Centro de Química e Bioquímica and Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
1 shared publication
Latest Publications
- Open Access
- 1 January 2013
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 36 (6) , 905-910
Determinação de parâmetros cinéticos em fluxo com câmara de gradiente e deteção espectrofotométrica: aplicação à reação entre o violeta de cristal e o ião hidróxido
A didactic experiment is proposed aimed to extend the Flow Injection Analysis (FIA) based methodology to the area of physical chemistry/chemical reactors for undergraduate labs. Our prime objective was to describe the use of a gradient chamber for determination of the rate constant for the reaction between crystal violet and the hydroxide ion. The study was complemented by determining the effect of temperature on the rate constant. The kinetic parameters, activation energy and reaction rate constant are determined based on an assumption of rate orders. The main didactic advantages of the proposed experimental set-up are the use of less reagents, contributing to a more environmental friendly experiment. The experiment illustrates also the reduction of associated errors and time by using automated analysis owing to decreased operator manipulation.
- 1 January 2013
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 36 (6) , 905-910
Open AccessDeterminação de parâmetros cinéticos em fluxo com câmara de gradiente e deteção espectrofotométrica: aplicação à reação entre o violeta de cristal e o ião hidróxido
A didactic experiment is proposed aimed to extend the Flow Injection Analysis (FIA) based methodology to the area of physical chemistry/chemical reactors for undergraduate labs. Our prime objective was to describe the use of a gradient chamber for determination of the rate constant for the reaction between crystal violet and the hydroxide ion. The study was complemented by determining the effect of temperature on the rate constant. The kinetic parameters, activation energy and reaction rate constant are determined based on an assumption of rate orders. The main didactic advantages of the proposed experimental set-up are the use of less reagents, contributing to a more environmental friendly experiment. The experiment illustrates also the reduction of associated errors and time by using automated analysis owing to decreased operator manipulation.
- 10 May 2011
- Published by American Chemical Society (ACS) in Journal of Chemical & Engineering Data
- Vol. 56 (6) , 2964-2970
Potentiometric Titration Study of the Temperature and Ionic Strength Dependence of the Acidity Constants of Nicotinic Acid (Niacin)
- 10 May 2011
- Published by American Chemical Society (ACS) in Journal of Chemical & Engineering Data
- Vol. 56 (6) , 2964-2970
Potentiometric Titration Study of the Temperature and Ionic Strength Dependence of the Acidity Constants of Nicotinic Acid (Niacin)
- Open Access
- 1 January 2011
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 34 (6) , 1074-1078
Constantes de acidez de ácidos dipróticos a partir de titulações potenciométricas: ilustração dos princípios do cálculo através da construção de um algoritmo muito simples
This work describes the creation of an very simple calculation algorithm, based in basic chemical and mathematic principles, for the calculation of weak diprotic acid dissociation constants as, for example, amino acids, from potentiometric titrations. For an easier understanding of the algorithm the logical reasoning of this calculus is schematized in a diagram of blocks. In the second part of the work the algorithm is applied to an Excel calculation sheet to determine the dissociation constants of Nicotinic Acid and Glycine, from the respective potentiometric titration curves. The values obtained using this algorithm are compared with those estimated by Hyperquad2008 (program generally used for this type of calculus) and also with the values of a stability constants database
- 1 January 2011
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 34 (6) , 1074-1078
Open AccessConstantes de acidez de ácidos dipróticos a partir de titulações potenciométricas: ilustração dos princípios do cálculo através da construção de um algoritmo muito simples
This work describes the creation of an very simple calculation algorithm, based in basic chemical and mathematic principles, for the calculation of weak diprotic acid dissociation constants as, for example, amino acids, from potentiometric titrations. For an easier understanding of the algorithm the logical reasoning of this calculus is schematized in a diagram of blocks. In the second part of the work the algorithm is applied to an Excel calculation sheet to determine the dissociation constants of Nicotinic Acid and Glycine, from the respective potentiometric titration curves. The values obtained using this algorithm are compared with those estimated by Hyperquad2008 (program generally used for this type of calculus) and also with the values of a stability constants database
- 1 December 2006
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 83 (12)
Determination of Acidity Constants by Gradient Flow-Injection Titration
- 1 December 2006
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 83 (12)
Determination of Acidity Constants by Gradient Flow-Injection Titration
- 15 March 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (8) , 2494-2499
Sequential Flow Injection Analysis System On-Line Coupled to High Intensity Focused Ultrasound: Green Methodology for Trace Analysis Applications As Demonstrated for the Determination of Inorganic and Total Mercury in Waters and Urine by Cold Vapor Atomic Absorption Spectrometry
A new concept is presented for green analytical applications based on coupling on-line high-intensity focused ultrasound (HIFU) with a sequential injection/flow injection analysis (SIA/FIA) system. The potential of the SIA/HIFU/FIA scheme is demonstrated by taking mercury as a model analyte. Using inorganic mercury, methylmercury, phenylmercury, and diphenylmercury, the usefulness of the proposed methodology for the determination of inorganic and total mercury in waters and urine was demonstrated. The procedure requires low sample volumes and reagents and can be further applied to all chemical reactions involving HIFU. The inherent advantages of SIA, FIA, and HIFU applications in terms of high throughput, automation, low reagent consumption, and green chemistry are accomplished together for the first time in the present work.
- 15 March 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (8) , 2494-2499
Sequential Flow Injection Analysis System On-Line Coupled to High Intensity Focused Ultrasound: Green Methodology for Trace Analysis Applications As Demonstrated for the Determination of Inorganic and Total Mercury in Waters and Urine by Cold Vapor Atomic Absorption Spectrometry
A new concept is presented for green analytical applications based on coupling on-line high-intensity focused ultrasound (HIFU) with a sequential injection/flow injection analysis (SIA/FIA) system. The potential of the SIA/HIFU/FIA scheme is demonstrated by taking mercury as a model analyte. Using inorganic mercury, methylmercury, phenylmercury, and diphenylmercury, the usefulness of the proposed methodology for the determination of inorganic and total mercury in waters and urine was demonstrated. The procedure requires low sample volumes and reagents and can be further applied to all chemical reactions involving HIFU. The inherent advantages of SIA, FIA, and HIFU applications in terms of high throughput, automation, low reagent consumption, and green chemistry are accomplished together for the first time in the present work.