Jonatan Eriksson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jonatan Eriksson has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Carl-Johan Carlhäll
Linköping University
7 shared publications - Tino Ebbers
Department of Health, Medicine and Caring Sciences Linköping University Linköping Sweden
7 shared publications Ann F. Bolger
Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
5 shared publications- Petter Dyverfeldt
Department of Medical and Health Sciences, Unit of Cardiovascular Sciences, Linköping University , Linköping
5 shared publications - Jan Engvall
Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
2 shared publications - Alexandru Grigorescu Fredriksson
Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
1 shared publication
Latest Publications
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 87
Atlas-based analysis of 4D flow CMR: Automated vessel segmentation and flow quantification
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 87
Open AccessAtlas-based analysis of 4D flow CMR: Automated vessel segmentation and flow quantification
- Open Access
- 26 November 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (6) , 1716-1725
Spatial heterogeneity of four‐dimensional relative pressure fields in the human left ventricle
Purpose To assess the spatial heterogeneity of the four-dimensional (4D) relative pressure fields in the healthy human left ventricle (LV) and provide reference data for normal LV relative pressure. Methods Twelve healthy subjects underwent a cardiac MRI examination where 4D flow and morphological data were acquired. The latter data were segmented and used to define the borders of the LV for computation of relative pressure fields using the pressure Poisson equation. The LV lumen was divided into 17 pie-shaped segments. Results In the normal left ventricle, the relative pressure in the apical segments was significantly higher relative to the basal segments (P < 0.0005) along both the anteroseptal and inferolateral sides after the peaks of early (E-wave) and late (A-wave) diastolic filling. The basal anteroseptal segment showed significantly lower median pressure than the opposite basal inferolateral segment during both E-wave (P < 0.0005) and A-wave (P = 0.0024). Conclusion Relative pressure in the left ventricle is heterogeneous. During diastole, the main pressure differences in the LV occur along the basal–apical axis. However, pressure differences were also found in the short axis direction and may reflect important aspects of atrioventricular coupling. Additionally, this study provides reference data on LV pressure dynamics for a group of healthy subjects. Magn Reson Med 74:1716–1725, 2015.
- 26 November 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (6) , 1716-1725
Open AccessSpatial heterogeneity of four‐dimensional relative pressure fields in the human left ventricle
Purpose To assess the spatial heterogeneity of the four-dimensional (4D) relative pressure fields in the healthy human left ventricle (LV) and provide reference data for normal LV relative pressure. Methods Twelve healthy subjects underwent a cardiac MRI examination where 4D flow and morphological data were acquired. The latter data were segmented and used to define the borders of the LV for computation of relative pressure fields using the pressure Poisson equation. The LV lumen was divided into 17 pie-shaped segments. Results In the normal left ventricle, the relative pressure in the apical segments was significantly higher relative to the basal segments (P < 0.0005) along both the anteroseptal and inferolateral sides after the peaks of early (E-wave) and late (A-wave) diastolic filling. The basal anteroseptal segment showed significantly lower median pressure than the opposite basal inferolateral segment during both E-wave (P < 0.0005) and A-wave (P = 0.0024). Conclusion Relative pressure in the left ventricle is heterogeneous. During diastole, the main pressure differences in the LV occur along the basal–apical axis. However, pressure differences were also found in the short axis direction and may reflect important aspects of atrioventricular coupling. Additionally, this study provides reference data on LV pressure dynamics for a group of healthy subjects. Magn Reson Med 74:1716–1725, 2015.
- Open Access
- 8 April 2014
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (4) , 1021-1029
Turbulent kinetic energy in normal and myopathic left ventricles
Purpose: To assess turbulent kinetic energy (TKE) within the left ventricle (LV) of healthy subjects using novel 4D flow magnetic resonance imaging (MRI) methods and to compare TKE values to those from a limited group of patients with a spectrum of dilated cardiomyopathy (DCM).Materials and Methods: 4D flow and morphological MRI data were acquired in 11 healthy subjects and 9 patients with different degrees of diastolic dysfunction. TKELV was calculated within the LV at each diastolic timeframe. At peak early (E) and late (A) diastolic filling, the TKELV was compared to transmitral peak velocity, LV diameter, and mitral annular diameter.Results: In the majority of subjects, TKELV peaks were observed at E and A. Peak TKELV at E was not different between the groups (P = 0.33), and correlated with mitral annular dimensions (r2 = 0.32, P = 0.01). Peak TKELV at A was higher in DCM patients compared to healthy subjects (3.0 ± 1.8 vs. 1.5 ± 0.8 mJ, P = 0.02), and correlated with LV diameter and transmitral velocity (r2 = 0.36, P = 0.01 and r2 = 0.47, P < 0.01, respectively).Conclusion: In LVs of healthy subjects, TKE values are low. Values are highest during early diastole, and diminish with increasing LV size. In a heterogeneous group of DCM patients, late diastolic TKE values are higher than in healthy subjects. J. Magn. Reson. Imaging 2015;41:1021–1029. © 2014 Wiley Periodicals, Inc.
- 8 April 2014
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (4) , 1021-1029
Open AccessTurbulent kinetic energy in normal and myopathic left ventricles
Purpose: To assess turbulent kinetic energy (TKE) within the left ventricle (LV) of healthy subjects using novel 4D flow magnetic resonance imaging (MRI) methods and to compare TKE values to those from a limited group of patients with a spectrum of dilated cardiomyopathy (DCM).Materials and Methods: 4D flow and morphological MRI data were acquired in 11 healthy subjects and 9 patients with different degrees of diastolic dysfunction. TKELV was calculated within the LV at each diastolic timeframe. At peak early (E) and late (A) diastolic filling, the TKELV was compared to transmitral peak velocity, LV diameter, and mitral annular diameter.Results: In the majority of subjects, TKELV peaks were observed at E and A. Peak TKELV at E was not different between the groups (P = 0.33), and correlated with mitral annular dimensions (r2 = 0.32, P = 0.01). Peak TKELV at A was higher in DCM patients compared to healthy subjects (3.0 ± 1.8 vs. 1.5 ± 0.8 mJ, P = 0.02), and correlated with LV diameter and transmitral velocity (r2 = 0.36, P = 0.01 and r2 = 0.47, P < 0.01, respectively).Conclusion: In LVs of healthy subjects, TKE values are low. Values are highest during early diastole, and diminish with increasing LV size. In a heterogeneous group of DCM patients, late diastolic TKE values are higher than in healthy subjects. J. Magn. Reson. Imaging 2015;41:1021–1029. © 2014 Wiley Periodicals, Inc.
- Open Access
- 8 August 2012
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 14 (5) , 417-424
Four-dimensional blood flow-specific markers of LV dysfunction in dilated cardiomyopathy
Patients with mild heart failure (HF) who are clinically compensated may have normal left ventricular (LV) stroke volume (SV). Despite this, altered intra-ventricular flow patterns have been recognized in these subjects. We hypothesized that, compared with normal LVs, flow in myopathic LVs would demonstrate a smaller proportion of inflow volume passing directly to ejection and diminished the end-diastolic preservation of the inflow kinetic energy (KE). In 10 patients with dilated cardiomyopathy (DCM) (49 ± 14 years, six females) and 10 healthy subjects (44 ± 17 years, four females), four-dimensional MRI velocity and morphological data were acquired. A previously validated method was used to separate the LV end-diastolic volume (EDV) into four flow components based on the blood's locations at the beginning and end of the cardiac cycle. KE was calculated over the cardiac cycle for each component. The EDV was larger (P = 0.021) and the ejection fraction smaller (P < 0.001) in DCM compared with healthy subjects; the SV was equivalent (DCM: 77 ± 19, healthy: 79 ± 16 mL). The proportion of the total LV inflow that passed directly to ejection was smaller in DCM (P = 0.000), but the end-diastolic KE/mL of the direct flow was not different in the two groups (NS). Despite equivalent LVSVs, HF patients with mild LV remodelling demonstrate altered diastolic flow routes through the LV and impaired preservation of inflow KE at pre-systole compared with healthy subjects. These unique flow-specific changes in the flow route and energetics are detectable despite clinical compensation, and may prove useful as subclinical markers of LV dysfunction.
- 8 August 2012
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 14 (5) , 417-424
Open AccessFour-dimensional blood flow-specific markers of LV dysfunction in dilated cardiomyopathy
Patients with mild heart failure (HF) who are clinically compensated may have normal left ventricular (LV) stroke volume (SV). Despite this, altered intra-ventricular flow patterns have been recognized in these subjects. We hypothesized that, compared with normal LVs, flow in myopathic LVs would demonstrate a smaller proportion of inflow volume passing directly to ejection and diminished the end-diastolic preservation of the inflow kinetic energy (KE). In 10 patients with dilated cardiomyopathy (DCM) (49 ± 14 years, six females) and 10 healthy subjects (44 ± 17 years, four females), four-dimensional MRI velocity and morphological data were acquired. A previously validated method was used to separate the LV end-diastolic volume (EDV) into four flow components based on the blood's locations at the beginning and end of the cardiac cycle. KE was calculated over the cardiac cycle for each component. The EDV was larger (P = 0.021) and the ejection fraction smaller (P < 0.001) in DCM compared with healthy subjects; the SV was equivalent (DCM: 77 ± 19, healthy: 79 ± 16 mL). The proportion of the total LV inflow that passed directly to ejection was smaller in DCM (P = 0.000), but the end-diastolic KE/mL of the direct flow was not different in the two groups (NS). Despite equivalent LVSVs, HF patients with mild LV remodelling demonstrate altered diastolic flow routes through the LV and impaired preservation of inflow KE at pre-systole compared with healthy subjects. These unique flow-specific changes in the flow route and energetics are detectable despite clinical compensation, and may prove useful as subclinical markers of LV dysfunction.
- Open Access
- 1 December 2011
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 301 (6) , H2344-H2350
4-D blood flow in the human right ventricle
Right ventricular (RV) function is a powerful prognostic indicator in many forms of heart disease, but its assessment remains challenging and inexact. RV dysfunction may alter the normal patterns of RV blood flow, but those patterns have been incompletely characterized. We hypothesized that, based on anatomic differences, the proportions and energetics of RV flow components would differ from those identified in the left ventricle (LV) and that the portion of the RV inflow passing directly to outflow ( Direct Flow) would be prepared for effective systolic ejection as a result of preserved kinetic energy (KE) compared with other RV flow components. Three-dimensional, time-resolved phase-contrast velocity, and balanced steady-state free-precession morphological data were acquired in 10 healthy subjects using MRI. A previously validated method was used to separate the RV and LV end-diastolic volumes into four flow components and measure their volume and KE over the cardiac cycle. The RV Direct Flow: 1) followed a smoothly curving route that did not extend into the apical region of the ventricle; 2) had a larger volume and possessed a larger presystolic KE (0.4 ± 0.3 mJ) than the other flow components ( P < 0.001 and P < 0.01, respectively); and 3) represented a larger part of the end-diastolic blood volume compared with the LV Direct Flow ( P < 0.01). These findings suggest that diastolic flow patterns distinct to the normal RV create favorable conditions for ensuing systolic ejection of the Direct Flow component. These flow-specific aspects of RV diastolic-systolic coupling provide novel perspectives on RV physiology and may add to the understanding of RV pathophysiology.
- 1 December 2011
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 301 (6) , H2344-H2350
Open Access4-D blood flow in the human right ventricle
Right ventricular (RV) function is a powerful prognostic indicator in many forms of heart disease, but its assessment remains challenging and inexact. RV dysfunction may alter the normal patterns of RV blood flow, but those patterns have been incompletely characterized. We hypothesized that, based on anatomic differences, the proportions and energetics of RV flow components would differ from those identified in the left ventricle (LV) and that the portion of the RV inflow passing directly to outflow ( Direct Flow) would be prepared for effective systolic ejection as a result of preserved kinetic energy (KE) compared with other RV flow components. Three-dimensional, time-resolved phase-contrast velocity, and balanced steady-state free-precession morphological data were acquired in 10 healthy subjects using MRI. A previously validated method was used to separate the RV and LV end-diastolic volumes into four flow components and measure their volume and KE over the cardiac cycle. The RV Direct Flow: 1) followed a smoothly curving route that did not extend into the apical region of the ventricle; 2) had a larger volume and possessed a larger presystolic KE (0.4 ± 0.3 mJ) than the other flow components ( P < 0.001 and P < 0.01, respectively); and 3) represented a larger part of the end-diastolic blood volume compared with the LV Direct Flow ( P < 0.01). These findings suggest that diastolic flow patterns distinct to the normal RV create favorable conditions for ensuing systolic ejection of the Direct Flow component. These flow-specific aspects of RV diastolic-systolic coupling provide novel perspectives on RV physiology and may add to the understanding of RV pathophysiology.
- Open Access
- 1 June 2011
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 300 (6) , H2135-H2141
Quantification of presystolic blood flow organization and energetics in the human left ventricle
Intracardiac blood flow patterns are potentially important to cardiac pumping efficiency. However, these complex flow patterns remain incompletely characterized both in health and disease. We hypothesized that normal left ventricular (LV) blood flow patterns would preferentially optimize a portion of the end-diastolic volume (LVEDV) for effective and rapid systolic ejection by virtue of location near and motion towards the LV outflow tract (LVOT). Three-dimensional cine velocity and morphological data were acquired in 12 healthy persons and 1 patient with dilated cardiomyopathy using MRI. A previously validated method was used for analysis in which the LVEDV was separated into four functional flow components based on the blood's locations at the beginning and end of the cardiac cycle. Each component's volume, kinetic energy (KE), site, direction, and linear momentum relative to the LVOT were calculated. Of the four components, the LV inflow that passes directly to outflow in a single cardiac cycle ( Direct Flow) had the largest volume. At the time of isovolumic contraction, Direct Flow had the greatest amount of KE and the most favorable combination of distance, angle, and linear momentum relative to the LVOT. Atrial contraction boosted the late diastolic KE of the ejected components. We conclude that normal diastolic LV flow creates favorable conditions for ensuing ejection, defined by proximity and energetics, for the Direct Flow, and that atrial contraction augments the end-diastolic KE of the ejection volume. The correlation of Direct Flow characteristics with ejection efficiency might be a relevant investigative target in cardiac failure.
- 1 June 2011
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 300 (6) , H2135-H2141
Open AccessQuantification of presystolic blood flow organization and energetics in the human left ventricle
Intracardiac blood flow patterns are potentially important to cardiac pumping efficiency. However, these complex flow patterns remain incompletely characterized both in health and disease. We hypothesized that normal left ventricular (LV) blood flow patterns would preferentially optimize a portion of the end-diastolic volume (LVEDV) for effective and rapid systolic ejection by virtue of location near and motion towards the LV outflow tract (LVOT). Three-dimensional cine velocity and morphological data were acquired in 12 healthy persons and 1 patient with dilated cardiomyopathy using MRI. A previously validated method was used for analysis in which the LVEDV was separated into four functional flow components based on the blood's locations at the beginning and end of the cardiac cycle. Each component's volume, kinetic energy (KE), site, direction, and linear momentum relative to the LVOT were calculated. Of the four components, the LV inflow that passes directly to outflow in a single cardiac cycle ( Direct Flow) had the largest volume. At the time of isovolumic contraction, Direct Flow had the greatest amount of KE and the most favorable combination of distance, angle, and linear momentum relative to the LVOT. Atrial contraction boosted the late diastolic KE of the ejected components. We conclude that normal diastolic LV flow creates favorable conditions for ensuing ejection, defined by proximity and energetics, for the Direct Flow, and that atrial contraction augments the end-diastolic KE of the ejection volume. The correlation of Direct Flow characteristics with ejection efficiency might be a relevant investigative target in cardiac failure.
- Open Access
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 9
Semi-automatic quantification of 4D left ventricular blood flow
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 9
Open AccessSemi-automatic quantification of 4D left ventricular blood flow