Sergio Alexander Salinas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sergio Alexander Salinas has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Laura Juliana Vargas Escobar
Facultad de Ingeniería Electrónica, Universidad Pontificia Bolivariana, Bucaramanga, Colombia
2 shared publications- Oscar Andrés Vivas Albán
Universidad del Cauca
2 shared publications C. A. Grimaldos-Trillos
Facultad de Ingeniería Electrónica, Universidad Pontificia Bolivariana, Bucaramanga, Colombia
1 shared publication- D. R. Paez Ardila
Pontifical Catholic University of Rio de Janeiro
1 shared publication E. R. Mancipe-Toloza
Facultad de Ingeniería Electrónica, Universidad Pontificia Bolivariana, Bucaramanga, Colombia
1 shared publication- Eliana Margarita Aguilar Larrarte
Universidad del Cauca Popayán-Colombia
1 shared publication
Latest Publications
- Open Access
- 10 February 2022
- Published by Universidad Nacional de Colombia in Ingeniería e Investigación
- Vol. 42 (3) , e87296
Emulating Textures Using Vibrotactile Technology: HaptTech System and its Adaptation to a Commercial Kinesthetic Interface
This article presents the development and testing of a tactile interface prototype, HaptTech, that applies vibrotactile stimulation patterns to the fingertip, as well as an analysis of its performance when coupled to the commercial kinesthetic interface Novint Falcon. Its applicability in digital entertainment expects to improve the level of immersion into virtual reality scenarios. In the first experiment, a group of 75 subjects compared three different vibration stimuli that emulated different textures. They evaluated the stimuli on a 1 to 10 scale, where 1 means ‘non-perceivable differences’ and 10 means ‘entirely differentiable’. The obtained mean values were 9 (textures 1 and 3), 8,29 (textures 1 and 2), and 7,43 (textures 2 and 3), indicating HaptTech’s capability to reproduce differentiable stimuli. In the second experiment, 31 subjects evaluated the coupling between HaptTech and Novint Falcon. They perceived differences when the HaptTech system was activated in the context of a comparison between kinesthetic and vibrotactile plus kinesthetic stimuli. In the third experiment, the subjects evaluated the similarity between the perceived stimuli on the hand and a visualized texture pattern in a virtual environment. The resulting median values were 8, 8, and 9 for textures 1, 2, and 3, respectively, which demonstrate that the subjects perceived a high correspondence for each one.
- 10 February 2022
- Published by Universidad Nacional de Colombia in Ingeniería e Investigación
- Vol. 42 (3) , e87296
Open AccessEmulating Textures Using Vibrotactile Technology: HaptTech System and its Adaptation to a Commercial Kinesthetic Interface
This article presents the development and testing of a tactile interface prototype, HaptTech, that applies vibrotactile stimulation patterns to the fingertip, as well as an analysis of its performance when coupled to the commercial kinesthetic interface Novint Falcon. Its applicability in digital entertainment expects to improve the level of immersion into virtual reality scenarios. In the first experiment, a group of 75 subjects compared three different vibration stimuli that emulated different textures. They evaluated the stimuli on a 1 to 10 scale, where 1 means ‘non-perceivable differences’ and 10 means ‘entirely differentiable’. The obtained mean values were 9 (textures 1 and 3), 8,29 (textures 1 and 2), and 7,43 (textures 2 and 3), indicating HaptTech’s capability to reproduce differentiable stimuli. In the second experiment, 31 subjects evaluated the coupling between HaptTech and Novint Falcon. They perceived differences when the HaptTech system was activated in the context of a comparison between kinesthetic and vibrotactile plus kinesthetic stimuli. In the third experiment, the subjects evaluated the similarity between the perceived stimuli on the hand and a visualized texture pattern in a virtual environment. The resulting median values were 8, 8, and 9 for textures 1, 2, and 3, respectively, which demonstrate that the subjects perceived a high correspondence for each one.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017, 452-454
Exoskeleton for gait rehabilitation of children: Conceptual design
This paper presents the conceptual design of an exoskeleton for gait rehabilitation of children. This system has electronics, mechanicals and software sections, which are implemented and tested using a mannequin of a child. The prototype uses servomotors to move robotic joints that are attached to simulated patient's legs. The design has 4 DOF (degrees of freedom) two for hip joints and other two for knee joints, in the sagittal plane. A microcontroller measures sensor signals, controls motors and exchanges data with a computer. The user interacts with a graphical interface to configure, control and monitor the exoskeleton activities. The laboratory tests show soften movements in joint angle tracking.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017, 452-454
Exoskeleton for gait rehabilitation of children: Conceptual design
This paper presents the conceptual design of an exoskeleton for gait rehabilitation of children. This system has electronics, mechanicals and software sections, which are implemented and tested using a mannequin of a child. The prototype uses servomotors to move robotic joints that are attached to simulated patient's legs. The design has 4 DOF (degrees of freedom) two for hip joints and other two for knee joints, in the sagittal plane. A microcontroller measures sensor signals, controls motors and exchanges data with a computer. The user interacts with a graphical interface to configure, control and monitor the exoskeleton activities. The laboratory tests show soften movements in joint angle tracking.
- 17 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Proposal of a short step and stride measurement system for uncontrolled environments
This paper presents a proposal of a measurement system that will permit to quantify two gait parameters: short step and stride, within uncontrolled environments. The short step and the stride are two important parameters in the gait analysis that usually are measured in a specialized laboratory, but this measurement can be done in uncontrolled environments where the patient would be more comfortable. In order to calculate the gait parameters without a complex setup, to use an Inertial Measurement Unit (IMU) is proposed, because it is a small and portable sensor, and provides linear acceleration data. These data are adjusted to offset the gravitational forces, and, in further research, they are going to be used to calculate the short step and stride.
- 17 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Proposal of a short step and stride measurement system for uncontrolled environments
This paper presents a proposal of a measurement system that will permit to quantify two gait parameters: short step and stride, within uncontrolled environments. The short step and the stride are two important parameters in the gait analysis that usually are measured in a specialized laboratory, but this measurement can be done in uncontrolled environments where the patient would be more comfortable. In order to calculate the gait parameters without a complex setup, to use an Inertial Measurement Unit (IMU) is proposed, because it is a small and portable sensor, and provides linear acceleration data. These data are adjusted to offset the gravitational forces, and, in further research, they are going to be used to calculate the short step and stride.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 4399-4402
e-Health prototype system for cardiac telemonitoring
This paper presents the approach of an e-health system for cardiac telemonitoring which uses the development board LinkIt ONE as a monitoring system. Such board was adapted to measure the cardiac pulse, analyze it and determine whether a person is having a cardiac arrhythmia or not. When an arrhythmia appears, the prototype activates an alarm in order to report the patient's condition and its location to a caregiver or a close healthcare center. The data of the cardiac pulse is originated in an e-health sensor platform connected to an Arduino. Location data comes from a GPS module in the aforementioned board which is connected by WiFi with the virtual platform UBIDOTS. It provides visual information about the variables measured, the patient's location and the alarms; keeping the patient's caregiver or the healthcare center constantly informed.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 4399-4402
e-Health prototype system for cardiac telemonitoring
This paper presents the approach of an e-health system for cardiac telemonitoring which uses the development board LinkIt ONE as a monitoring system. Such board was adapted to measure the cardiac pulse, analyze it and determine whether a person is having a cardiac arrhythmia or not. When an arrhythmia appears, the prototype activates an alarm in order to report the patient's condition and its location to a caregiver or a close healthcare center. The data of the cardiac pulse is originated in an e-health sensor platform connected to an Arduino. Location data comes from a GPS module in the aforementioned board which is connected by WiFi with the virtual platform UBIDOTS. It provides visual information about the variables measured, the patient's location and the alarms; keeping the patient's caregiver or the healthcare center constantly informed.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A toolholder robot for laparoscopy based in the Novint Falcon interface: Workspace
A toolholder robot is proposed for laparoscopy using a Novint Falcon haptic interface, adapted to a laparoscopic forceps through a system of passive joints; this article describes the direct and inverse kinematics for both the interface as well as for the passive joints that form the robot model. The simulation allows to observe that the system maintains a pivotal movement in a Cartesian point of incision, and it is verified that the workspace of the robot will allow conducting training exercises in a simulated abdomen.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A toolholder robot for laparoscopy based in the Novint Falcon interface: Workspace
A toolholder robot is proposed for laparoscopy using a Novint Falcon haptic interface, adapted to a laparoscopic forceps through a system of passive joints; this article describes the direct and inverse kinematics for both the interface as well as for the passive joints that form the robot model. The simulation allows to observe that the system maintains a pivotal movement in a Cartesian point of incision, and it is verified that the workspace of the robot will allow conducting training exercises in a simulated abdomen.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23278161,p. 1-5
Force control and haptic interface applied to prototype of myoelectric prosthetic hand
Development of a force control hardware embedded system for a Prototype of Prosthetic Gripper Hand with 1 grade of liberty is shown. A myoelectric signal is used to enable a servo motor movement which permits opening and closing the prosthesis. The prosthesis force is controlled with a Proportional and Integrative (PI) incremental control. Furthermore, a little vibrator motor acts like a haptic interface and it is put on the user arm; the prosthesis force applied against an object is related with the vibrator motor frequency.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23278161,p. 1-5
Force control and haptic interface applied to prototype of myoelectric prosthetic hand
Development of a force control hardware embedded system for a Prototype of Prosthetic Gripper Hand with 1 grade of liberty is shown. A myoelectric signal is used to enable a servo motor movement which permits opening and closing the prosthesis. The prosthesis force is controlled with a Proportional and Integrative (PI) incremental control. Furthermore, a little vibrator motor acts like a haptic interface and it is put on the user arm; the prosthesis force applied against an object is related with the vibrator motor frequency.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23278161,p. 1-4
Electronic glove for rehabilitation exercises controlling a mobile robot
This paper presents the implementation process of an electronic wireless system. It allows making exercises for hand rehabilitation. The patient can control movements of a mobile robot; it has to use movements of its hand and the electronic glove. The robot is controlled by an accelerometer that is located in the glove; an electronic prototyping platform obtains motion signals from the sensor and processes it.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23278161,p. 1-4
Electronic glove for rehabilitation exercises controlling a mobile robot
This paper presents the implementation process of an electronic wireless system. It allows making exercises for hand rehabilitation. The patient can control movements of a mobile robot; it has to use movements of its hand and the electronic glove. The robot is controlled by an accelerometer that is located in the glove; an electronic prototyping platform obtains motion signals from the sensor and processes it.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Serious game for rehabilitation of meniscus injury using a prototype of orthosis
This paper presents the design of a prototype rehabilitation system through the adaptation of a knee brace control function as a serious game, so it links the entertainment of a game with the progress of rehabilitation, using as based physical therapy is performed after a meniscus operation.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Serious game for rehabilitation of meniscus injury using a prototype of orthosis
This paper presents the design of a prototype rehabilitation system through the adaptation of a knee brace control function as a serious game, so it links the entertainment of a game with the progress of rehabilitation, using as based physical therapy is performed after a meniscus operation.
- Open Access
- 1 December 2009
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 17 (3) , 317-328
MODELADO, SIMULACIÓN Y CONTROL DEL ROBOT PARA CIRUGÍA LAPAROSCÓPICA 'LAPBOT'
- 1 December 2009
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 17 (3) , 317-328
Open AccessMODELADO, SIMULACIÓN Y CONTROL DEL ROBOT PARA CIRUGÍA LAPAROSCÓPICA 'LAPBOT'
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 2183-2188
Operational Space Control for a Puma Robot
This article shows a simple methodology to implement an operational space control on a 6-DOF arm robot. First, the model is linearized and decoupled by feedback, next a computed torque control scheme in the operational space is implemented with a Jacobian matrix calculus running within small sampling period, is exhibited. Major simulation results performed using numerical values of an industrial PUMA robot prove the effectiveness of the proposed approach. The performance of the operational space control and the widely used computed torque control in the joint space is compared. The simulated results are presented to illustrate the behavior of the control schemes with tracking performance and robustness with respect to external disturbances and errors in the dynamic model.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 2183-2188
Operational Space Control for a Puma Robot
This article shows a simple methodology to implement an operational space control on a 6-DOF arm robot. First, the model is linearized and decoupled by feedback, next a computed torque control scheme in the operational space is implemented with a Jacobian matrix calculus running within small sampling period, is exhibited. Major simulation results performed using numerical values of an industrial PUMA robot prove the effectiveness of the proposed approach. The performance of the operational space control and the widely used computed torque control in the joint space is compared. The simulated results are presented to illustrate the behavior of the control schemes with tracking performance and robustness with respect to external disturbances and errors in the dynamic model.