Jun-Ichi Asaumi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jun-Ichi Asaumi has a total of 212 co-authors. Here are the top co-authors by number of shared publications:
Miki Hisatomi
20 shared publicationsYoshinobu Yanagi
Department of Dental Informatics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
17 shared publicationsHidenobu Matsuzaki
Department of Oral Diagnosis and Dentomaxillofacial Radiology, Okayama University Hospital, Okayama, Japan
16 shared publicationsHironobu Konouchi
Department of Oral Diagnosis and Dentomaxillofacial Radiology, Okayama University Hospital of Medicine and Dentistry, Okayama, Japan
16 shared publicationsKanji Kishi
Okayama University
13 shared publications- Yoshinobu Yanagi
Department of Oral and Maxillofacial Radiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama 700-8558, Japan
13 shared publications
Latest Publications
- Open Access
- 20 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (6) , 790
Improving Diagnostic Performance for Head and Neck Tumors with Simple Diffusion Kurtosis Imaging and Machine Learning Bi-Parameter Analysis
Background/Objectives: Mean kurtosis (MK) values in simple diffusion kurtosis imaging (SDI)—a type of diffusion kurtosis imaging (DKI)—have been reported to be useful in the diagnosis of head and neck malignancies, for which pre-processing with smoothing filters has been reported to improve the diagnostic accuracy. Multi-parameter analysis using DKI in combination with other image types has recently been reported to improve the diagnostic performance. The purpose of this study was to evaluate the usefulness of machine learning (ML)-based multi-parameter analysis using the MK and apparent diffusion coefficient (ADC) values—which can be acquired simultaneously through SDI—for the differential diagnosis of benign and malignant head and neck tumors, which is important for determining the treatment strategy, as well as examining the usefulness of filter pre-processing. Methods: A total of 32 pathologically diagnosed head and neck tumors were included in the study, and a Gaussian filter was used for image pre-processing. MK and ADC values were extracted from pixels within the tumor area and used as explanatory variables. Five ML algorithms were used to create models for the prediction of tumor status (benign or malignant), which were evaluated through ROC analysis. Results: Bi-parameter analysis with gradient boosting achieved the best diagnostic performance, with an AUC of 0.81. Conclusions: The usefulness of bi-parameter analysis with ML methods for the differential diagnosis of benign and malignant head and neck tumors using SDI data were demonstrated.
- 20 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (6) , 790
Open AccessImproving Diagnostic Performance for Head and Neck Tumors with Simple Diffusion Kurtosis Imaging and Machine Learning Bi-Parameter Analysis
Background/Objectives: Mean kurtosis (MK) values in simple diffusion kurtosis imaging (SDI)—a type of diffusion kurtosis imaging (DKI)—have been reported to be useful in the diagnosis of head and neck malignancies, for which pre-processing with smoothing filters has been reported to improve the diagnostic accuracy. Multi-parameter analysis using DKI in combination with other image types has recently been reported to improve the diagnostic performance. The purpose of this study was to evaluate the usefulness of machine learning (ML)-based multi-parameter analysis using the MK and apparent diffusion coefficient (ADC) values—which can be acquired simultaneously through SDI—for the differential diagnosis of benign and malignant head and neck tumors, which is important for determining the treatment strategy, as well as examining the usefulness of filter pre-processing. Methods: A total of 32 pathologically diagnosed head and neck tumors were included in the study, and a Gaussian filter was used for image pre-processing. MK and ADC values were extracted from pixels within the tumor area and used as explanatory variables. Five ML algorithms were used to create models for the prediction of tumor status (benign or malignant), which were evaluated through ROC analysis. Results: Bi-parameter analysis with gradient boosting achieved the best diagnostic performance, with an AUC of 0.81. Conclusions: The usefulness of bi-parameter analysis with ML methods for the differential diagnosis of benign and malignant head and neck tumors using SDI data were demonstrated.
- Open Access
- 10 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (6) , 668
Robustness of Machine Learning Predictions for Determining Whether Deep Inspiration Breath-Hold Is Required in Breast Cancer Radiation Therapy
Background/Objectives: Deep inspiration breath-hold (DIBH) is a commonly used technique to reduce the mean heart dose (MHD), which is critical for minimizing late cardiac side effects in breast cancer patients undergoing radiation therapy (RT). Although previous studies have explored the potential of machine learning (ML) to predict which patients might benefit from DIBH, none have rigorously assessed ML model performance across various MHD thresholds and parameter settings. This study aims to evaluate the robustness of ML models in predicting the need for DIBH across different clinical scenarios. Methods: Using data from 207 breast cancer patients treated with RT, we developed and tested ML models at three MHD cut-off values (240, 270, and 300 cGy), considering variations in the number of independent variables (three vs. six) and folds in the cross-validation (three, four, and five). Robustness was defined as achieving high F2 scores and low instability in predictive performance. Results: Our findings indicate that the decision tree (DT) model demonstrated consistently high robustness at 240 and 270 cGy, while the random forest model performed optimally at 300 cGy. At 240 cGy, a threshold critical to minimize late cardiac risks, the DT model exhibited stable predictive power, reducing the risk of overestimating DIBH necessity. Conclusions: These results suggest that the DT model, particularly at lower MHD thresholds, may be the most reliable for clinical applications. By providing a tool for targeted DIBH implementation, this model has the potential to enhance patient-specific treatment planning and improve clinical outcomes in RT.
- 10 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (6) , 668
Open AccessRobustness of Machine Learning Predictions for Determining Whether Deep Inspiration Breath-Hold Is Required in Breast Cancer Radiation Therapy
Background/Objectives: Deep inspiration breath-hold (DIBH) is a commonly used technique to reduce the mean heart dose (MHD), which is critical for minimizing late cardiac side effects in breast cancer patients undergoing radiation therapy (RT). Although previous studies have explored the potential of machine learning (ML) to predict which patients might benefit from DIBH, none have rigorously assessed ML model performance across various MHD thresholds and parameter settings. This study aims to evaluate the robustness of ML models in predicting the need for DIBH across different clinical scenarios. Methods: Using data from 207 breast cancer patients treated with RT, we developed and tested ML models at three MHD cut-off values (240, 270, and 300 cGy), considering variations in the number of independent variables (three vs. six) and folds in the cross-validation (three, four, and five). Robustness was defined as achieving high F2 scores and low instability in predictive performance. Results: Our findings indicate that the decision tree (DT) model demonstrated consistently high robustness at 240 and 270 cGy, while the random forest model performed optimally at 300 cGy. At 240 cGy, a threshold critical to minimize late cardiac risks, the DT model exhibited stable predictive power, reducing the risk of overestimating DIBH necessity. Conclusions: These results suggest that the DT model, particularly at lower MHD thresholds, may be the most reliable for clinical applications. By providing a tool for targeted DIBH implementation, this model has the potential to enhance patient-specific treatment planning and improve clinical outcomes in RT.
- Open Access
Efficacy of Cisplatin–CXCR4 Antagonist Combination Therapy in Oral Cancer
Cisplatin is a platinum-based compound that is widely used for treating inoperable oral squamous cell carcinoma (OSCC) in Japan; however, resistance to cisplatin presents a challenge and innovative approaches are required. We aimed to investigate the therapeutic potential of targeting the chemokine receptor CXCR4, which is involved in angiogenesis and tumor progression, using the CXCR4 inhibitor AMD3100, in combination with cisplatin. AMD3100 induced necrosis and bleeding in OSCC xenografts by inhibiting angiogenesis. We investigated the combined ability of AMD3100 plus cisplatin to enhance the antitumor effect in cisplatin-resistant OSCC. An MTS assay identified HSC-2 cells as cisplatin-resistant cells in vitro. Mice treated with the cisplatin-AMD combination exhibited the most significant reduction in tumor volume, accompanied by extensive hemorrhage and necrosis. Histological examination indicated thin and short tumor vessels in the AMD and cisplatin–AMD groups. These results indicated that cisplatin and AMD3100 had synergistic antitumor effects, highlighting their potential for vascular therapy of refractory OSCC. Antitumor vascular therapy using cisplatin combined with a CXCR4 inhibitor provides a novel strategy for addressing cisplatin-resistant OSCC.
Open AccessEfficacy of Cisplatin–CXCR4 Antagonist Combination Therapy in Oral Cancer
Cisplatin is a platinum-based compound that is widely used for treating inoperable oral squamous cell carcinoma (OSCC) in Japan; however, resistance to cisplatin presents a challenge and innovative approaches are required. We aimed to investigate the therapeutic potential of targeting the chemokine receptor CXCR4, which is involved in angiogenesis and tumor progression, using the CXCR4 inhibitor AMD3100, in combination with cisplatin. AMD3100 induced necrosis and bleeding in OSCC xenografts by inhibiting angiogenesis. We investigated the combined ability of AMD3100 plus cisplatin to enhance the antitumor effect in cisplatin-resistant OSCC. An MTS assay identified HSC-2 cells as cisplatin-resistant cells in vitro. Mice treated with the cisplatin-AMD combination exhibited the most significant reduction in tumor volume, accompanied by extensive hemorrhage and necrosis. Histological examination indicated thin and short tumor vessels in the AMD and cisplatin–AMD groups. These results indicated that cisplatin and AMD3100 had synergistic antitumor effects, highlighting their potential for vascular therapy of refractory OSCC. Antitumor vascular therapy using cisplatin combined with a CXCR4 inhibitor provides a novel strategy for addressing cisplatin-resistant OSCC.
- Open Access
- 20 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (6) , 1783
Enhancing Diagnostic Precision: Evaluation of Preprocessing Filters in Simple Diffusion Kurtosis Imaging for Head and Neck Tumors
Background: Our initial clinical study using simple diffusion kurtosis imaging (SDI), which simultaneously produces a diffusion kurtosis image (DKI) and an apparent diffusion coefficient map, confirmed the usefulness of SDI for tumor diagnosis. However, the obtained DKI had noticeable variability in the mean kurtosis (MK) values, which is inherent to SDI. We aimed to improve this variability in SDI by preprocessing with three different filters (Gaussian [G], median [M], and nonlocal mean) of the diffusion-weighted images used for SDI. Methods: The usefulness of filter parameters for diagnosis was examined in basic and clinical studies involving 13 patients with head and neck tumors. Results: The filter parameters, which did not change the median MK value, but reduced the variability and significantly homogenized the MK values in tumor and normal tissues in both basic and clinical studies, were identified. In the receiver operating characteristic curve analysis for distinguishing tumors from normal tissues using MK values, the area under curve values significantly improved from 0.627 without filters to 0.641 with G (σ = 0.5) and 0.638 with M (radius = 0.5). Conclusions: Thus, image pretreatment with G and M for SDI was shown to be useful for improving tumor diagnosis in clinical practice.
- 20 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (6) , 1783
Open AccessEnhancing Diagnostic Precision: Evaluation of Preprocessing Filters in Simple Diffusion Kurtosis Imaging for Head and Neck Tumors
Background: Our initial clinical study using simple diffusion kurtosis imaging (SDI), which simultaneously produces a diffusion kurtosis image (DKI) and an apparent diffusion coefficient map, confirmed the usefulness of SDI for tumor diagnosis. However, the obtained DKI had noticeable variability in the mean kurtosis (MK) values, which is inherent to SDI. We aimed to improve this variability in SDI by preprocessing with three different filters (Gaussian [G], median [M], and nonlocal mean) of the diffusion-weighted images used for SDI. Methods: The usefulness of filter parameters for diagnosis was examined in basic and clinical studies involving 13 patients with head and neck tumors. Results: The filter parameters, which did not change the median MK value, but reduced the variability and significantly homogenized the MK values in tumor and normal tissues in both basic and clinical studies, were identified. In the receiver operating characteristic curve analysis for distinguishing tumors from normal tissues using MK values, the area under curve values significantly improved from 0.627 without filters to 0.641 with G (σ = 0.5) and 0.638 with M (radius = 0.5). Conclusions: Thus, image pretreatment with G and M for SDI was shown to be useful for improving tumor diagnosis in clinical practice.
- Open Access
- 22 January 2024
- Published by Springer Nature in Oral Radiology
- Vol. 40 (2) , 277-284
Imaging characteristics of incidentally detected cosmetic surgery-derived foreign bodies on CT images in the maxillofacial region
Objectives: This study examined the imaging characteristics of cosmetic surgery-derived foreign bodies in the maxillofacial region through a retrospective review of cosmetic material foreign bodies incidentally detected on computed tomography (CT) images in routine clinical practice. Methods: We retrospectively investigated cases of cosmetic surgery-derived foreign bodies other than dental materials in the maxillofacial region, using 5 years of CT image data stored on an imaging server. The imaging findings of these foreign bodies were investigated, along with patient age, patient sex, whether the foreign bodies were associated with the disease targeted by the CT scan, and the availability of cosmetic surgery information prior to examination. Results: Foreign bodies were more common in women (19/21 cases), and affected patients displayed a wide age range (20–84 years). Four types of cosmetic surgery-derived foreign bodies in the maxillofacial region were detected by CT examination: nasal prostheses (nasal region), lifting sutures and injectable facial fillers (both in the buccal region), and silicone chin implants (chin region). Conclusions: A cosmetic surgery-derived foreign body should be suspected when a foreign body is identified without a dental source of infection. In addition, cosmetic surgery-derived foreign bodies may be present in numerous patients, regardless of age or sex.
- 22 January 2024
- Published by Springer Nature in Oral Radiology
- Vol. 40 (2) , 277-284
Open AccessImaging characteristics of incidentally detected cosmetic surgery-derived foreign bodies on CT images in the maxillofacial region
Objectives: This study examined the imaging characteristics of cosmetic surgery-derived foreign bodies in the maxillofacial region through a retrospective review of cosmetic material foreign bodies incidentally detected on computed tomography (CT) images in routine clinical practice. Methods: We retrospectively investigated cases of cosmetic surgery-derived foreign bodies other than dental materials in the maxillofacial region, using 5 years of CT image data stored on an imaging server. The imaging findings of these foreign bodies were investigated, along with patient age, patient sex, whether the foreign bodies were associated with the disease targeted by the CT scan, and the availability of cosmetic surgery information prior to examination. Results: Foreign bodies were more common in women (19/21 cases), and affected patients displayed a wide age range (20–84 years). Four types of cosmetic surgery-derived foreign bodies in the maxillofacial region were detected by CT examination: nasal prostheses (nasal region), lifting sutures and injectable facial fillers (both in the buccal region), and silicone chin implants (chin region). Conclusions: A cosmetic surgery-derived foreign body should be suspected when a foreign body is identified without a dental source of infection. In addition, cosmetic surgery-derived foreign bodies may be present in numerous patients, regardless of age or sex.
- Open Access
- 7 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (24) , 3619
Characteristic Mean Kurtosis Values in Simple Diffusion Kurtosis Imaging of Dentigerous Cysts
We evaluated the usefulness of simple diffusion kurtosis (SD) imaging, which was developed to generate diffusion kurtosis images simultaneously with an apparent diffusion coefficient (ADC) map for 27 cystic disease lesions in the head and neck region. The mean kurtosis (MK) and ADC values were calculated for the cystic space. The MK values were dentigerous cyst (DC): 0.74, odontogenic keratocyst (OKC): 0.86, ranula (R): 0.13, and mucous cyst (M): 0, and the ADC values were DC: 1364 × 10−6 mm2/s, OKC: 925 × 10−6 mm2/s, R: 2718 × 10−6 mm2/s, and M: 2686 × 10−6 mm2/s. The MK values of DC and OKC were significantly higher than those of R and M, whereas their ADC values were significantly lower. One reason for the characteristic signal values in diffusion-weighted images of DC may be related to content components such as fibrous tissue and exudate cells. When imaging cystic disease in the head and neck region using SD imaging, the maximum b-value setting at the time of imaging should be limited to approximately 1200 s/mm2 for accurate MK value calculation. This study is the first to show that the MK values of DC are characteristically higher than those of other cysts.
- 7 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (24) , 3619
Open AccessCharacteristic Mean Kurtosis Values in Simple Diffusion Kurtosis Imaging of Dentigerous Cysts
We evaluated the usefulness of simple diffusion kurtosis (SD) imaging, which was developed to generate diffusion kurtosis images simultaneously with an apparent diffusion coefficient (ADC) map for 27 cystic disease lesions in the head and neck region. The mean kurtosis (MK) and ADC values were calculated for the cystic space. The MK values were dentigerous cyst (DC): 0.74, odontogenic keratocyst (OKC): 0.86, ranula (R): 0.13, and mucous cyst (M): 0, and the ADC values were DC: 1364 × 10−6 mm2/s, OKC: 925 × 10−6 mm2/s, R: 2718 × 10−6 mm2/s, and M: 2686 × 10−6 mm2/s. The MK values of DC and OKC were significantly higher than those of R and M, whereas their ADC values were significantly lower. One reason for the characteristic signal values in diffusion-weighted images of DC may be related to content components such as fibrous tissue and exudate cells. When imaging cystic disease in the head and neck region using SD imaging, the maximum b-value setting at the time of imaging should be limited to approximately 1200 s/mm2 for accurate MK value calculation. This study is the first to show that the MK values of DC are characteristically higher than those of other cysts.
- Open Access
- 4 August 2023
- Published by MDPI AG in Current Oncology
- Vol. 30 (8) , 7412-7424
Mean Heart Dose Prediction Using Parameters of Single-Slice Computed Tomography and Body Mass Index: Machine Learning Approach for Radiotherapy of Left-Sided Breast Cancer of Asian Patients
Deep inspiration breath-hold (DIBH) is an excellent technique to reduce the incidental radiation received by the heart during radiotherapy in patients with breast cancer. However, DIBH is costly and time-consuming for patients and radiotherapy staff. In Asian countries, the use of DIBH is restricted due to the limited number of patients with a high mean heart dose (MHD) and the shortage of radiotherapy personnel and equipment compared to that in the USA. This study aimed to develop, evaluate, and compare the performance of ten machine learning algorithms for predicting MHD using a patient’s body mass index and single-slice CT parameters to identify patients who may not require DIBH. Machine learning models were built and tested using a dataset containing 207 patients with left-sided breast cancer who were treated with field-in-field radiotherapy with free breathing. The average MHD was 251 cGy. Stratified repeated four-fold cross-validation was used to build models using 165 training data. The models were compared internally using their average performance metrics: F2 score, AUC, recall, accuracy, Cohen’s kappa, and Matthews correlation coefficient. The final performance evaluation for each model was further externally analyzed using 42 unseen test data. The performance of each model was evaluated as a binary classifier by setting the cut-off value of MHD ≥ 300 cGy. The deep neural network (DNN) achieved the highest F2 score (78.9%). Most models successfully classified all patients with high MHD as true positive. This study indicates that the ten models, especially the DNN, might have the potential to identify patients who may not require DIBH.
- 4 August 2023
- Published by MDPI AG in Current Oncology
- Vol. 30 (8) , 7412-7424
Open AccessMean Heart Dose Prediction Using Parameters of Single-Slice Computed Tomography and Body Mass Index: Machine Learning Approach for Radiotherapy of Left-Sided Breast Cancer of Asian Patients
Deep inspiration breath-hold (DIBH) is an excellent technique to reduce the incidental radiation received by the heart during radiotherapy in patients with breast cancer. However, DIBH is costly and time-consuming for patients and radiotherapy staff. In Asian countries, the use of DIBH is restricted due to the limited number of patients with a high mean heart dose (MHD) and the shortage of radiotherapy personnel and equipment compared to that in the USA. This study aimed to develop, evaluate, and compare the performance of ten machine learning algorithms for predicting MHD using a patient’s body mass index and single-slice CT parameters to identify patients who may not require DIBH. Machine learning models were built and tested using a dataset containing 207 patients with left-sided breast cancer who were treated with field-in-field radiotherapy with free breathing. The average MHD was 251 cGy. Stratified repeated four-fold cross-validation was used to build models using 165 training data. The models were compared internally using their average performance metrics: F2 score, AUC, recall, accuracy, Cohen’s kappa, and Matthews correlation coefficient. The final performance evaluation for each model was further externally analyzed using 42 unseen test data. The performance of each model was evaluated as a binary classifier by setting the cut-off value of MHD ≥ 300 cGy. The deep neural network (DNN) achieved the highest F2 score (78.9%). Most models successfully classified all patients with high MHD as true positive. This study indicates that the ten models, especially the DNN, might have the potential to identify patients who may not require DIBH.
- Open Access
- 1 January 2022
- Published by XMLink in Imaging Science in Dentistry
- Vol. 52 (1) , 67-74
Influence of mesiodens on adjacent teeth and the timing of its safe removal
Barham M, et al. Imaging Sci Dent. 2022 Jan;52:e4. https://doi.org/10.5624/isd.20210218
- 1 January 2022
- Published by XMLink in Imaging Science in Dentistry
- Vol. 52 (1) , 67-74
Open AccessInfluence of mesiodens on adjacent teeth and the timing of its safe removal
Barham M, et al. Imaging Sci Dent. 2022 Jan;52:e4. https://doi.org/10.5624/isd.20210218
- 23 February 2021
- Published by Springer Nature in Oral Radiology
- Vol. 37 (2) , 189-208
Clinical guidelines for the application of panoramic radiographs in screening for osteoporosis
Osteoporotic fractures are associated with an increased risk of subsequent fractures, a higher rate of mortality, and incremental medical costs. Incidental findings, which include some measurements related to the mandibular inferior cortex and the alveolar trabecular bone pattern of the mandible determined on panoramic radiographs, are considered to be a useful tool for identifying asymptomatic individuals at risk of having osteoporosis and/or fragility fractures. We undertook a worldwide literature survey and present the following clinical recommendations. Postmenopausal female dental patients with a mandibular inferior cortical width of less than 3 mm on panoramic radiographs may be at risk of having low skeletal bone mineral density (BMD) or osteoporosis, but not fragility fractures. In addition, those with a severely eroded mandibular inferior cortex may have an increased risk of having low skeletal BMD, osteoporosis, and fragility fractures. The alveolar trabecular bone pattern of the mandible might be useful for identifying female dental patients at risk of having fragility fractures, although further investigation is necessary to confirm this possibility. These incidental findings on panoramic radiographs, when used for identifying asymptomatic postmenopausal female patients at risk of having osteoporosis in general dental practice, may be helpful in reducing the incidence of first fractures, with a consequent reduction in the secondary fractures, medical costs, and mortality associated with osteoporotic fragility fractures, without incurring any additional cost.
- 23 February 2021
- Published by Springer Nature in Oral Radiology
- Vol. 37 (2) , 189-208
Clinical guidelines for the application of panoramic radiographs in screening for osteoporosis
Osteoporotic fractures are associated with an increased risk of subsequent fractures, a higher rate of mortality, and incremental medical costs. Incidental findings, which include some measurements related to the mandibular inferior cortex and the alveolar trabecular bone pattern of the mandible determined on panoramic radiographs, are considered to be a useful tool for identifying asymptomatic individuals at risk of having osteoporosis and/or fragility fractures. We undertook a worldwide literature survey and present the following clinical recommendations. Postmenopausal female dental patients with a mandibular inferior cortical width of less than 3 mm on panoramic radiographs may be at risk of having low skeletal bone mineral density (BMD) or osteoporosis, but not fragility fractures. In addition, those with a severely eroded mandibular inferior cortex may have an increased risk of having low skeletal BMD, osteoporosis, and fragility fractures. The alveolar trabecular bone pattern of the mandible might be useful for identifying female dental patients at risk of having fragility fractures, although further investigation is necessary to confirm this possibility. These incidental findings on panoramic radiographs, when used for identifying asymptomatic postmenopausal female patients at risk of having osteoporosis in general dental practice, may be helpful in reducing the incidence of first fractures, with a consequent reduction in the secondary fractures, medical costs, and mortality associated with osteoporotic fragility fractures, without incurring any additional cost.
- 1 February 2021
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 50 (2) , 20200188
Assessment of Hounsfield unit in the differential diagnosis of odontogenic cysts
Objectives: The purpose of this study was to evaluate the usefulness of Hounsfield unit (HU) assessment with multislice-CT in the differentiation of radicular cysts (RCs), dentigerous cysts (DCs) and odontogenic keratocysts (OKCs). Methods: In total, 307 odontogenic cysts (RCs, DCs and OKCs) were included in this study. Cysts with lesion diameter <10 mm, cysts with artefacts affecting measurement of HU values, cysts involving infection and recurrent cysts were regarded as exclusion criteria. Images were acquired in three different types of CT scanners: Aquilion ONE, Discovery CT750 HD and SOMATOM Definition Flash. Differences in HU values among scanners and among types of odontogenic cysts were assessed using one-way analysis of variance; multiple comparisons were performed post hoc, using the Tukey–Kramer honestly significant difference test. Results: In total, 164 cysts were analysed in this study (64 RCs, 57 DCs and 43 OKCs). Regardless of the type of lesion, the Aquilion ONE scanner demonstrated a significant difference in HU value, compared with the Discovery CT750 HD scanner. Regardless of CT scanner model, HU values significantly differed between DCs and OKCs (p < 0.0001), as well as between OKCs and RCs (p < 0.0001). Conclusions: HU values were found to vary among CT scanners and should always be associated with other lesion imaging features while interpreting and elaboration diagnostic hypothesis. Notably, the results suggested that OKCs might be able to be differentiated from DCs and RCs by using HU values.
- 1 February 2021
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 50 (2) , 20200188
Assessment of Hounsfield unit in the differential diagnosis of odontogenic cysts
Objectives: The purpose of this study was to evaluate the usefulness of Hounsfield unit (HU) assessment with multislice-CT in the differentiation of radicular cysts (RCs), dentigerous cysts (DCs) and odontogenic keratocysts (OKCs). Methods: In total, 307 odontogenic cysts (RCs, DCs and OKCs) were included in this study. Cysts with lesion diameter <10 mm, cysts with artefacts affecting measurement of HU values, cysts involving infection and recurrent cysts were regarded as exclusion criteria. Images were acquired in three different types of CT scanners: Aquilion ONE, Discovery CT750 HD and SOMATOM Definition Flash. Differences in HU values among scanners and among types of odontogenic cysts were assessed using one-way analysis of variance; multiple comparisons were performed post hoc, using the Tukey–Kramer honestly significant difference test. Results: In total, 164 cysts were analysed in this study (64 RCs, 57 DCs and 43 OKCs). Regardless of the type of lesion, the Aquilion ONE scanner demonstrated a significant difference in HU value, compared with the Discovery CT750 HD scanner. Regardless of CT scanner model, HU values significantly differed between DCs and OKCs (p < 0.0001), as well as between OKCs and RCs (p < 0.0001). Conclusions: HU values were found to vary among CT scanners and should always be associated with other lesion imaging features while interpreting and elaboration diagnostic hypothesis. Notably, the results suggested that OKCs might be able to be differentiated from DCs and RCs by using HU values.