ADAgnese Denzi

Agnese Denzi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Agnese Denzi has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microdosimetry for pulsed E fields in a realistic models of cells and endoplasmic reticulum

    by Agnese Denzi, Hanna Hanna, Franck M. Andre, Lluis M. Mir, Francesca Apollonio, Micaela Liberti

    Microsecond pulsed electric fields (μsPEFs) with amplitude of tens of kV/m are used to permeabilize the plasma membrane whereas nanosecond pulsed electric fields of MV/m also permeabilize cell internal structures, such as the endoplasmic reticulum. In this work, a numerical realistic model of cell and its reticulum has been realized to study the use of μsPEFs also for the permeabilization of this internal structure.


  • Numerical estimation of a 10 nanosecond pulse effects on non-uniformly distributed liposomes

    by Elena Della Valle, Francesca Apollonio, Micaela Liberti, Agnese Denzi, Lluis M. Mir

    Nano-systems, often used in biomedical applications for the treatment of a broad category of illnesses, represent one of the nanomedicine approaches recently proposed to target specific drugs only in the region where the disease has been developed. Recently the use of this technique has been proposed with electropulsation, hence taking advantage of the enhanced permeabilization of the cell membrane and simultaneously control the release of the encapsulated drug by the nano-system. In this work, we focus our attention on the study of liposomes nano-systems controlled by the nanosecond pulses electric fields through a microdosimetric approach. The aim is to analyse the electric field necessary to porate a non-uniform distribution of 400 nm liposomes. The work has been carried out by randomly placing 30 liposomes between two electrodes with the application of a 10 nano-second electric field pulse.


  • A computational design of a versatile microchamber for in vitro nanosecond pulsed electric fields experiments

    by Maura Casciola, Micaela Liberti, Agnese Denzi, Alessandra Paffi, Caterina Merla, Francesca Apollonio


  • A microdosimetry study for a realistic shaped nucleus

    by A. Denzi, J. A. A. Escobar, C. Nasta, C. Merla, B. Benassi, C. Consales, F. Apollonio, M. Liberti

    In the last decades, the effects of ultrashort pulsed electric fields have been investigated demonstrating their capability to be involved in a great number of medical applications (e.g. cancer, gene electrotransfer, drug delivery, electrofusion). In particular, experiments in literature demonstrate that internal structures can be involved when pulse duration is reduced. Up to now, the mechanism that permits the electroporation phenomenon has not been completely understood and hence atomistic, microdosimetry and dosimetry models have been developed to help in this field. Aim of this work is to demonstrate the importance of realistically model also the internal organelles to obtain predictive results of effects at sub-cellular level with a microdosimetry model.


  • Exploring the Applicability of Nano-Poration for Remote Control in Smart Drug Delivery Systems

    by Agnese Denzi, Elena della Valle, Francesca Apollonio, Marie Breton, Lluis M. Mir, Micaela Liberti

    Smart drug delivery systems represent an interesting tool to significantly improve the efficiency and the precision in the treatment of a broad category of diseases. In this context, a drug delivery mediated by nanosecond pulsed electric fields seems a promising technique, allowing for a controlled release and uptake of drugs by the synergy between the electropulsation and nanocarriers with encapsulated drugs. The main concern about the use of electroporation for drug delivery applications is the difference in dimension between the liposome (nanometer range) and the cell (micrometer range). The choice of liposome dimension is not trivial. Liposomes larger than 500 nm of diameter could be recognized as pathogen agents by the immune system, while liposomes of smaller size would require external electric field of high amplitudes for the membrane electroporation that could compromise the cell viability. The aim of this work is to theoretically study the possibility of a simultaneous cell and liposomes electroporation. The numerical simulations reported the possibility to electroporate the cell and a significant percentage of liposomes with comparable values of external electric field, when a 12 nsPEF is used.


  • Microchambers for cell exposure: From the design to applications

    by A. Denzi, C. Merla, M. Casciola, J. C. M. Hwang, X. Cheng, F. Apollonio, M. Liberti

    In the last decades, the advances in the micro and nano fabrication techniques have led to the development of microdevices that improved the possibility of analysis at cell level. These devices can be used in different applications (e.g., cell detection and identification, manipulation, cell treatments). The requisites, that are necessary to achieve, are different for various applications and represent the starting point of the project. The numerical multiphysics models can be very advantageous to analyze the performances of such devices and to predict their operation. Aim of this work is to give a look of the design rules of microchamber devices in particular for their application in electric field exposure. Two different applications for cell discrimination and characterization are reported considering time and frequency domain measurements.


  • A Microdosimetric Study of Electropulsation on Multiple Realistically Shaped Cells: Effect of Neighbours

    by Agnese Denzi, Francesca Camera, Caterina Merla, Barbara Benassi, Claudia Consales, Alessandra Paffi, Francesca Apollonio, Micaela Liberti

    Over the past decades, the effects of ultrashort-pulsed electric fields have been used to investigate their action in many medical applications (e.g. cancer, gene electrotransfer, drug delivery, electrofusion). Promising aspects of these pulses has led to several in vitro and in vivo experiments to clarify their action. Since the basic mechanisms of these pulses have not yet been fully clarified, scientific interest has focused on the development of numerical models at different levels of complexity: atomic (molecular dynamic simulations), microscopic (microdosimetry) and macroscopic (dosimetry). The aim of this work is to demonstrate that, in order to predict results at the cellular level, an accurate microdosimetry model is needed using a realistic cell shape, and with their position and packaging (cell density) characterised inside the medium.


  • A numerical design of versatile microchambers for nsPEFs experiments

    by Maura Casciola, Micaela Liberti, Francesca Apollonio, Agnese Denzi

    The emergence of nanosecond pulsed electric fields (nsPEFs) for intracellular electro-manipulation experiments implies the application of extremely short (ns) high intensity (MV/m) electric field pulses. Specific pulse generators and miniaturized applicators are necessary to properly deliver this category of voltage signals to biological loads. In this context, we propose the design of a versatile nsPEFs applicator, developed following the guidelines typical of microwave propagating systems. The designed microchamber is suitable for in vitro exposure to undistorted pulses with duration down to 1-3 ns during single and multi cell experiments. Further features are: high efficiency (above 0.95), high cell viability by the integration of microfluidic components, real time monitoring of the biological sample and of the pulse propagation. These features can be considered as designing rules for new nanosecond and sub-nanosecond applicators, to ensure experimental repeatability and reproducibility when the impact of propagation on pulse signals is no more negligible.


  • Open Access

    Modeling the positioning of single needle electrodes for the treatment of breast cancer in a clinical case

    by Agnese Denzi, Lidia Strigari, Franco Di Filippo, Claudio Botti, Simona Di Filippo, Letizia Perracchio, Mattia Ronchetti, Ruggero Cadossi, Micaela Liberti

    Breast cancer is the most common cancer in women worldwide and is the second most common cause of cancer death in women. Electrochemotherapy (ECT) used in early-phase clinical trials for the treatment of primary breast cancer resulted in a not complete tumor necrosis in most cases. The present study was undertaken to analyze the feasibility to use ECT to treat patients with histologically proven unifocal ductal breast cancer. In particular, results of ECT treatment in a clinical case are compared with the ones of a simplified 3D dosimetric model. This clinical study was conducted with the pulse generator Cliniporator Vitae (IGEA, Carpi, Italy). ECT procedures were performed according to ESOPE standard operating procedures. Five single needle electrodes were used with one positioned in the center of the tumor, and the other four distributed around the nodule. Histological images of the resected tumor are compared with the maps of the electric field obtained with a simplified 3D model in Comsol Multiphysics v 4.3. The results of the clinical case demonstrated a reduced efficacy of the ECT treatment described. The proposed simple numerical model of the breast tumor located in a low conductive tissue suggests that this is due to the reduced electric field induced inside the tumor with such 5 electrodes placement. However, where the electric field is predicted higher than the reversible electroporation threshold (E>400 V/cm), also the histological images confirm the necrosis of the target with a good agreement between the modeled and clinical results. The results suggest the dependence of the effectiveness of the treatment on the careful placement of the electrodes. A detailed planned procedure for the tumor analysis after the treatment is also needed in order to better correlate the single electrode positions and the histological images. Simulation models could be used to identify better electrodes configuration in planning the experimental protocol for ECT treatment of breast tumors.


  • Assessment of Cytoplasm Conductivity by Nanosecond Pulsed Electric Fields

    by Agnese Denzi, Caterina Merla, Cristiano Palego, Alessandra Paffi, Yaqing Ning, Caroline R. Multari, Xuanhong Cheng, Francesca Apollonio, James C. M. Hwang, Micaela Liberti

    The aim of this paper is to propose a new method for the better assessment of cytoplasm conductivity, which is critical to the development of electroporation protocols as well as insight into fundamental mechanisms underlying electroporation. For this goal, we propose to use nanosecond electrical pulses to bypass the complication of membrane polarization and a single cell to avoid the complication of the application of the “mixing formulas.” Further, by suspending the cell in a low-conductivity medium, it is possible to force most of the sensing current through the cytoplasm for a more direct assessment of its conductivity. For proof of principle, the proposed technique was successfully demonstrated on a Jurkat cell by comparing the measured and modeled currents. The cytoplasm conductivity was best assessed at 0.32 S/m and it is in line with the literature. The cytoplasm conductivity plays a key role in the understanding of the basis mechanism of the electroporation phenomenon, and in particular, a large error in the cytoplasm conductivity determination could result in a correspondingly large error in predicting electroporation. Methods for a good estimation of such parameter become fundamental.