Nobutomo Morita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nobutomo Morita has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Wataru Iwasaki
Sensing Technology Research Institute, National Institute of Advanced Industrial Science and Technology, Tosu 841-0052, Japan
11 shared publications - Eiji Higurashi
Graduate School of Engineering, Tohoku University, Sendai, Japan
7 shared publications - Kenshin Takemura
Sensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), 807-1 Shuku-machi, Tosu, Saga 841-0052, Japan
5 shared publications Renshi Sawada
Kyushu Univ, Dept Mech Engn, Fac Engn, Nishi Ku, 744 Motooka, Fukuoka, Fukuoka 8190395, Japan
5 shared publications- Shinya Ohmagari
Sensing Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 807-1 Shuku-Machi, Tosu, Saga 841-0052, Japan
3 shared publications Toshihiro Takeshita
Sensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tosu, Saga, Japan
3 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by Wiley in Animal Science Journal
- Vol. 96 (1) , e70069
Enhanced Retinol Extraction From Bovine Whole Blood Using n ‐Hexane and Phosphate‐Buffered Saline
Ensuring optimal blood retinol levels of cattle during fattening is essential for achieving high‐quality marbling in beef production. We previously developed a rapid analytical method for measuring blood retinol concentration that eliminates the process of blood cell separation. However, achieving a strong correlation with actual retinol levels proved challenging due to the requirements of vigorous agitation of blood and n ‐hexane using a vortex mixer. Consequently, in this study, we developed a modified method that does not require intense agitation by adding phosphate‐buffered saline (PBS) to the blood and n ‐hexane mixture. The addition of PBS facilitated the dispersion of whole blood in n ‐hexane, although the augmented interface between the two enhanced extraction efficiency. Furthermore, we conducted field tests using blood samples collected from 98 fattening cattle from six different farms, each using distinct feeding methods and rearing environments, to reflect the diverse feeding practices in Japanese Black beef production. Their retinol concentrations were analyzed using the developed method and compared with values obtained by HPLC. A correlation coefficient of 0.94–0.96 was obtained, indicating that blood retinol levels can be reliably measured even among farms with different feeding methods.
- 1 January 2025
- Published by Wiley in Animal Science Journal
- Vol. 96 (1) , e70069
Open AccessEnhanced Retinol Extraction From Bovine Whole Blood Using n ‐Hexane and Phosphate‐Buffered Saline
Ensuring optimal blood retinol levels of cattle during fattening is essential for achieving high‐quality marbling in beef production. We previously developed a rapid analytical method for measuring blood retinol concentration that eliminates the process of blood cell separation. However, achieving a strong correlation with actual retinol levels proved challenging due to the requirements of vigorous agitation of blood and n ‐hexane using a vortex mixer. Consequently, in this study, we developed a modified method that does not require intense agitation by adding phosphate‐buffered saline (PBS) to the blood and n ‐hexane mixture. The addition of PBS facilitated the dispersion of whole blood in n ‐hexane, although the augmented interface between the two enhanced extraction efficiency. Furthermore, we conducted field tests using blood samples collected from 98 fattening cattle from six different farms, each using distinct feeding methods and rearing environments, to reflect the diverse feeding practices in Japanese Black beef production. Their retinol concentrations were analyzed using the developed method and compared with values obtained by HPLC. A correlation coefficient of 0.94–0.96 was obtained, indicating that blood retinol levels can be reliably measured even among farms with different feeding methods.
- Open Access
- 5 June 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (11) , 981
Determination of Low Concentrations of Mercury Based on the Electrodeposition Time
Soil plays a crucial role in human health through its impact on food and habitation. However, it often contains toxic heavy metals, with mercury being particularly hazardous when methylated. Currently, high-sensitivity, rapid detection of mercury is achievable only through electrochemical measurements. These measurements require pretreatment of the soil sample and the preparation of a calibration curve tailored to the sample’s condition. In this study, we developed a method to determine the environmental standard value of mercury content in soil by significantly reducing the pretreatment process. Our approach involves analyzing current peaks from electrodeposition times using specific electrodes and solvent settings. This method demonstrates low error rates under low concentration conditions and can detect mercury levels as low as 0.5 ppb in soil leachate and reagent dilution series. This research facilitates the determination of low mercury concentrations in solutions containing various soil micro-compounds without the need for calibration curves.
- 5 June 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (11) , 981
Open AccessDetermination of Low Concentrations of Mercury Based on the Electrodeposition Time
Soil plays a crucial role in human health through its impact on food and habitation. However, it often contains toxic heavy metals, with mercury being particularly hazardous when methylated. Currently, high-sensitivity, rapid detection of mercury is achievable only through electrochemical measurements. These measurements require pretreatment of the soil sample and the preparation of a calibration curve tailored to the sample’s condition. In this study, we developed a method to determine the environmental standard value of mercury content in soil by significantly reducing the pretreatment process. Our approach involves analyzing current peaks from electrodeposition times using specific electrodes and solvent settings. This method demonstrates low error rates under low concentration conditions and can detect mercury levels as low as 0.5 ppb in soil leachate and reagent dilution series. This research facilitates the determination of low mercury concentrations in solutions containing various soil micro-compounds without the need for calibration curves.
- Open Access
- 27 February 2024
- Published by Elsevier in Diamond and Related Materials
- Vol. 144
Electrochemical fingerprinting of complex solutions using boron-doped diamond electrodes: Advanced classifications by machine learning
- 27 February 2024
- Published by Elsevier in Diamond and Related Materials
- Vol. 144
Open AccessElectrochemical fingerprinting of complex solutions using boron-doped diamond electrodes: Advanced classifications by machine learning
- Open Access
Design and Fabrication of a Thin and Micro-Optical Sensor for Rapid Prototyping
Optical sensing offers several advantages owing to its non-invasiveness and high sensitivity. The miniaturization of optical sensors will mitigate spatial and weight constraints, expanding their applications and extending the principal advantages of optical sensing to different fields, such as healthcare, Internet of Things, artificial intelligence, and other aspects of society. In this study, we present the development of a miniature optical sensor for monitoring thrombi in extracorporeal membrane oxygenation (ECMO). The sensor, based on a complementary metal-oxide semiconductor integrated circuit (CMOS-IC), also serves as a photodiode, amplifier, and light-emitting diode (LED)-mounting substrate. It is sized 3.8 × 4.8 × 0.75 mm3 and provides reflectance spectroscopy at three wavelengths. Based on semiconductor and microelectromechanical system (MEMS) processes, the design of the sensor achieves ultra-compact millimeter size, customizability, prototyping, and scalability for mass production, facilitating the development of miniature optical sensors for a variety of applications.
Open AccessDesign and Fabrication of a Thin and Micro-Optical Sensor for Rapid Prototyping
Optical sensing offers several advantages owing to its non-invasiveness and high sensitivity. The miniaturization of optical sensors will mitigate spatial and weight constraints, expanding their applications and extending the principal advantages of optical sensing to different fields, such as healthcare, Internet of Things, artificial intelligence, and other aspects of society. In this study, we present the development of a miniature optical sensor for monitoring thrombi in extracorporeal membrane oxygenation (ECMO). The sensor, based on a complementary metal-oxide semiconductor integrated circuit (CMOS-IC), also serves as a photodiode, amplifier, and light-emitting diode (LED)-mounting substrate. It is sized 3.8 × 4.8 × 0.75 mm3 and provides reflectance spectroscopy at three wavelengths. Based on semiconductor and microelectromechanical system (MEMS) processes, the design of the sensor achieves ultra-compact millimeter size, customizability, prototyping, and scalability for mass production, facilitating the development of miniature optical sensors for a variety of applications.
- Open Access
- 1 February 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (2) , 025153
Suppression of substrate temperature in DC magnetron sputtering deposition by magnetic mirror-type magnetron cathode
Magnetron sputtering generally increases the temperature of the substrate placed to face the sputtering target above 40 °C because the plasmas are transported through unbalanced magnetic field lines from the sputtering target to the substrate surface. However, by using a magnetic mirror-type magnetron cathode, we were able to suppress the temperature of the substrate temperature to the environmental temperature of less than 40 °C at a target–substrate distance of 50 mm with a DC input power of 30 W and an Ar gas pressure of 0.15 Pa. This was possible because the balanced magnetic field lines confined the plasmas near the sputtering target. By enabling film deposition on low heat-resistant substrates, this deposition technique for suppressing the substrate temperature may have uses in various application fields.- 1 February 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (2) , 025153
Open AccessSuppression of substrate temperature in DC magnetron sputtering deposition by magnetic mirror-type magnetron cathode
Magnetron sputtering generally increases the temperature of the substrate placed to face the sputtering target above 40 °C because the plasmas are transported through unbalanced magnetic field lines from the sputtering target to the substrate surface. However, by using a magnetic mirror-type magnetron cathode, we were able to suppress the temperature of the substrate temperature to the environmental temperature of less than 40 °C at a target–substrate distance of 50 mm with a DC input power of 30 W and an Ar gas pressure of 0.15 Pa. This was possible because the balanced magnetic field lines confined the plasmas near the sputtering target. By enabling film deposition on low heat-resistant substrates, this deposition technique for suppressing the substrate temperature may have uses in various application fields. - Open Access
- 19 May 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (10) , 1741
High-Density and Monodisperse Electrochemical Gold Nanoparticle Synthesis Utilizing the Properties of Boron-Doped Diamond Electrodes
Owing to its simplicity and sensitivity, electrochemical analysis is of high significance in the detection of pollutants and highly toxic substances in the environment. In electrochemical analysis, the sensitivity of the sensor and reliability of the obtained signal are especially dependent on the electrode characteristics. Electrodes with a high density of nanomaterials, which exhibit excellent activity, are useful as sensor substrates for pollutant detection. However, the effective placement of high-density nanomaterials requires a high degree of control over the particle size, particle shape, and distance between the particles on the substrate. In this study, we exploited the properties of boron-doped diamond (BDD) electrodes, which have a wide potential window, and succeeded in coating a highly dense layer of gold nanoparticles (AuNPs) at high potential. The AuNP-modified BDD (AuNP-BDD) electrodes comprising less than 100 nm AuNPs at a density of 125 particles/µm were electrochemically synthesized over a short period of 30–60 s. The AuNP-BDD electrodes were applied for detecting arsenic, which is one of the most abundant elements, and exhibited a limit of detection of 0.473 ppb in solution.
- 19 May 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (10) , 1741
Open AccessHigh-Density and Monodisperse Electrochemical Gold Nanoparticle Synthesis Utilizing the Properties of Boron-Doped Diamond Electrodes
Owing to its simplicity and sensitivity, electrochemical analysis is of high significance in the detection of pollutants and highly toxic substances in the environment. In electrochemical analysis, the sensitivity of the sensor and reliability of the obtained signal are especially dependent on the electrode characteristics. Electrodes with a high density of nanomaterials, which exhibit excellent activity, are useful as sensor substrates for pollutant detection. However, the effective placement of high-density nanomaterials requires a high degree of control over the particle size, particle shape, and distance between the particles on the substrate. In this study, we exploited the properties of boron-doped diamond (BDD) electrodes, which have a wide potential window, and succeeded in coating a highly dense layer of gold nanoparticles (AuNPs) at high potential. The AuNP-modified BDD (AuNP-BDD) electrodes comprising less than 100 nm AuNPs at a density of 125 particles/µm were electrochemically synthesized over a short period of 30–60 s. The AuNP-BDD electrodes were applied for detecting arsenic, which is one of the most abundant elements, and exhibited a limit of detection of 0.473 ppb in solution.
- Open Access
- 28 April 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (5) , 690
Reversible Thermo-Responsive Valve for Microfluidic Paper-Based Analytical Devices
Fluid control on a paper channel is necessary for analysis with multiple reagents, such as enzyme-linked immunosorbent assay (ELISA) in microfluidic paper-based analytical devices (µPADs). In this study, a thermo-responsive valve was fabricated by polymerizing N-isopropylacrylamide on a PVDF porous membrane by plasma-induced graft polymerization. The polymerized membrane was observed by scanning electron microscopy (SEM), and it was confirmed that more pores were closed at temperatures below 32 °C and more pores were opened at temperatures above 32 °C. Valve permeability tests confirmed that the proposed polymerized membrane was impermeable to water and proteins at temperatures below 32 °C and permeable to water at temperatures above 32 °C. The valve could also be reversibly and repeatedly opened and closed by changing the temperature near 32 °C. These results suggest that plasma-induced graft polymerization may be used to produce thermo-responsive valves that can be opened and closed without subsequent loss of performance. These results indicate that the thermo-responsive valve fabricated by plasma-induced graft polymerization could potentially be applied to ELISA with µPADs.
- 28 April 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (5) , 690
Open AccessReversible Thermo-Responsive Valve for Microfluidic Paper-Based Analytical Devices
Fluid control on a paper channel is necessary for analysis with multiple reagents, such as enzyme-linked immunosorbent assay (ELISA) in microfluidic paper-based analytical devices (µPADs). In this study, a thermo-responsive valve was fabricated by polymerizing N-isopropylacrylamide on a PVDF porous membrane by plasma-induced graft polymerization. The polymerized membrane was observed by scanning electron microscopy (SEM), and it was confirmed that more pores were closed at temperatures below 32 °C and more pores were opened at temperatures above 32 °C. Valve permeability tests confirmed that the proposed polymerized membrane was impermeable to water and proteins at temperatures below 32 °C and permeable to water at temperatures above 32 °C. The valve could also be reversibly and repeatedly opened and closed by changing the temperature near 32 °C. These results suggest that plasma-induced graft polymerization may be used to produce thermo-responsive valves that can be opened and closed without subsequent loss of performance. These results indicate that the thermo-responsive valve fabricated by plasma-induced graft polymerization could potentially be applied to ELISA with µPADs.
- Open Access
- 1 January 2021
- Published by Wiley in Animal Science Journal
- Vol. 92 (1) , e13606
Preliminary system of rapid analysis of blood retinol level in cattle
Control of blood retinol levels in cattle during fattening is important in the production of marbled beef. However, it is difficult to easily measure the blood retinol concentration in the field. In this study, we attempted to develop an analysis method that does not require blood cell separation and uses a compact fluorescence analyzer that can be carried around as a preliminary system for measuring blood retinol concentration in the field. This system was used to monitor blood retinol levels in 12 fattening cattle (14 to 27 months old) and demonstrated a strong correlation ( r = 0.78) with the results obtained by the standard high‐performance liquid chromatography (HPLC) method. Stronger correlations ( r = 0.87) were obtained until the cattle were 24 months of age. These results suggest that higher correlations can be expected to be obtained by improving the robustness of the extraction system. Refinements for practical use need to be considered, but whole blood extraction and the vitamin A analyzer that was developed show potential to be used for on‐farm monitoring of retinol levels.
- 1 January 2021
- Published by Wiley in Animal Science Journal
- Vol. 92 (1) , e13606
Open AccessPreliminary system of rapid analysis of blood retinol level in cattle
Control of blood retinol levels in cattle during fattening is important in the production of marbled beef. However, it is difficult to easily measure the blood retinol concentration in the field. In this study, we attempted to develop an analysis method that does not require blood cell separation and uses a compact fluorescence analyzer that can be carried around as a preliminary system for measuring blood retinol concentration in the field. This system was used to monitor blood retinol levels in 12 fattening cattle (14 to 27 months old) and demonstrated a strong correlation ( r = 0.78) with the results obtained by the standard high‐performance liquid chromatography (HPLC) method. Stronger correlations ( r = 0.87) were obtained until the cattle were 24 months of age. These results suggest that higher correlations can be expected to be obtained by improving the robustness of the extraction system. Refinements for practical use need to be considered, but whole blood extraction and the vitamin A analyzer that was developed show potential to be used for on‐farm monitoring of retinol levels.
- Open Access
- 10 December 2020
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 44 (8) , 565-573
Real-time, non-invasive thrombus detection in an extracorporeal circuit using micro-optical thrombus sensors
Introduction: Real-time, non-invasive monitoring of thrombus formation in extracorporeal circuits has yet to be achieved. To address the challenges of conventional optical thrombus detection methods requiring large devices that limit detection capacity, we developed a micro-optical thrombus sensor. Methods: The proposed micro-optical thrombus sensor can detect the intensity of light scattered by blood at wavelengths of 660 and 855 nm. Two thrombus sensors were installed on in vitro circuit: one at the rotary blood pump and one at a flow channel. To evaluate the variation in the ratio of incident light intensity at each wavelength of the two sensors, Rfluct (for 660 nm) and Ifluct (for 855 nm) were defined. Using fresh porcine blood as a working fluid, we performed in vitro tests of haematocrit (Hct) and oxygen saturation (SaO2) variation and thrombus detection. Thrombus tests were terminated after Rfluct or Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. Results: In all three thrombus detection tests, Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. After the tests, thrombus formation was confirmed in the pump, and there was no thrombus in the flow channel. The results indicate that Ifluct is an effective parameter for identifying the presence of a thrombus. Conclusion: Thrombus detection in an extracorporeal circuit using the developed micro-optical sensors was successfully demonstrated in an in vitro test.
- 10 December 2020
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 44 (8) , 565-573
Open AccessReal-time, non-invasive thrombus detection in an extracorporeal circuit using micro-optical thrombus sensors
Introduction: Real-time, non-invasive monitoring of thrombus formation in extracorporeal circuits has yet to be achieved. To address the challenges of conventional optical thrombus detection methods requiring large devices that limit detection capacity, we developed a micro-optical thrombus sensor. Methods: The proposed micro-optical thrombus sensor can detect the intensity of light scattered by blood at wavelengths of 660 and 855 nm. Two thrombus sensors were installed on in vitro circuit: one at the rotary blood pump and one at a flow channel. To evaluate the variation in the ratio of incident light intensity at each wavelength of the two sensors, Rfluct (for 660 nm) and Ifluct (for 855 nm) were defined. Using fresh porcine blood as a working fluid, we performed in vitro tests of haematocrit (Hct) and oxygen saturation (SaO2) variation and thrombus detection. Thrombus tests were terminated after Rfluct or Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. Results: In all three thrombus detection tests, Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. After the tests, thrombus formation was confirmed in the pump, and there was no thrombus in the flow channel. The results indicate that Ifluct is an effective parameter for identifying the presence of a thrombus. Conclusion: Thrombus detection in an extracorporeal circuit using the developed micro-optical sensors was successfully demonstrated in an in vitro test.