Andreas F. Borkenstein
Research Subjects
Andreas F. Borkenstein has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Eva-Maria Borkenstein
Borkenstein & Borkenstein Research & Laboratory Gmbh, Privatklinik der Kreuzschwestern, Graz, Austria
37 shared publications- Ruediger Schmid
Accuratis, Practice for Refractive Eye Surgery, Ulm, Germany
6 shared publications - Achim Langenbucher
Department of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany
4 shared publications E. M. Borkenstein
Borkenstein & Borkenstein private practice, Privatklinik Der Kreuzschwestern Graz, Graz, Austria
4 shared publicationsAchim Langenbucher
Institute of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany
3 shared publicationsHarald Fitzek
Institute of Electron Microscopy and Nanoanalysis (FELMI), Graz University of Technology
3 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-14
Geometry-Based Intravitreal Pharmacokinetics: A Theoretical Pharmacokinetic Modeling Study Using Triamcinolone Acetonide and Vancomycin as Representative Intravitreal Agents
Purpose: To quantify how anatomical variation in vitreous cavity volume, estimated from axial length (AL) using the VIVEX formula, influences intravitreal drug concentration, therapeutic exposure duration, and immediate intraocular pressure (IOP) dynamics under fixed-dose intravitreal therapy. Patients and Methods: This theoretical pharmacokinetic modeling study utilized the VIVEX equation {V = (π/6) × AL3 × [0.76 + 0.012(AL − 24)]} to calculate vitreous volume (VV) for three representative eye types: small hyperopic (AL 20 mm), emmetropic (AL 23.5 mm), and large myopic (AL 30 mm). A one-compartment first-order elimination model was applied to two commonly used intravitreal agents: triamcinolone acetonide (4 mg) and vancomycin (1 mg). Primary outcomes included initial concentration (C0), duration above therapeutic threshold (t_eff), and modeled acute IOP rise. A Monte-Carlo simulation (10,000 virtual eyes) was performed to estimate population-level variability. Results: Modeled VV increased from 2.98 mL (AL 20 mm) to 11.76 mL (AL 30 mm), producing an approximately fourfold difference in C0. For triamcinolone, C0 decreased from 1.34 to 0.34 mg/mL and t_eff decreased from 67.4 to 31.8 days (≈50% reduction). For vancomycin, C0 decreased from 0.336 to 0.085 mg/mL and t_eff decreased from 9.1 to 6.1 days. Predicted immediate IOP elevations were ~4.3 mmHg in small eyes versus ~1.1 mmHg in large eyes. Monte Carlo analysis suggested that anatomical variability accounts for ~30% of modeled pharmacokinetic variance. Conclusion: Anatomical differences in VV substantially and predictably influence intravitreal pharmacokinetics. The modeled results demonstrate that fixed intravitreal dosing leads to substantial geometry-driven differences in drug exposure across eye sizes. Fixed dosing strategies may increase peak exposure and IOP load in small eyes and shorten effective therapeutic duration in large myopic eyes. Biometry-stratified clinical studies are warranted to validate these modeling predictions and to assess their clinical relevance in intravitreal antibiotic and corticosteroid therapies.
- 1 March 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-14
Open AccessGeometry-Based Intravitreal Pharmacokinetics: A Theoretical Pharmacokinetic Modeling Study Using Triamcinolone Acetonide and Vancomycin as Representative Intravitreal Agents
Purpose: To quantify how anatomical variation in vitreous cavity volume, estimated from axial length (AL) using the VIVEX formula, influences intravitreal drug concentration, therapeutic exposure duration, and immediate intraocular pressure (IOP) dynamics under fixed-dose intravitreal therapy. Patients and Methods: This theoretical pharmacokinetic modeling study utilized the VIVEX equation {V = (π/6) × AL3 × [0.76 + 0.012(AL − 24)]} to calculate vitreous volume (VV) for three representative eye types: small hyperopic (AL 20 mm), emmetropic (AL 23.5 mm), and large myopic (AL 30 mm). A one-compartment first-order elimination model was applied to two commonly used intravitreal agents: triamcinolone acetonide (4 mg) and vancomycin (1 mg). Primary outcomes included initial concentration (C0), duration above therapeutic threshold (t_eff), and modeled acute IOP rise. A Monte-Carlo simulation (10,000 virtual eyes) was performed to estimate population-level variability. Results: Modeled VV increased from 2.98 mL (AL 20 mm) to 11.76 mL (AL 30 mm), producing an approximately fourfold difference in C0. For triamcinolone, C0 decreased from 1.34 to 0.34 mg/mL and t_eff decreased from 67.4 to 31.8 days (≈50% reduction). For vancomycin, C0 decreased from 0.336 to 0.085 mg/mL and t_eff decreased from 9.1 to 6.1 days. Predicted immediate IOP elevations were ~4.3 mmHg in small eyes versus ~1.1 mmHg in large eyes. Monte Carlo analysis suggested that anatomical variability accounts for ~30% of modeled pharmacokinetic variance. Conclusion: Anatomical differences in VV substantially and predictably influence intravitreal pharmacokinetics. The modeled results demonstrate that fixed intravitreal dosing leads to substantial geometry-driven differences in drug exposure across eye sizes. Fixed dosing strategies may increase peak exposure and IOP load in small eyes and shorten effective therapeutic duration in large myopic eyes. Biometry-stratified clinical studies are warranted to validate these modeling predictions and to assess their clinical relevance in intravitreal antibiotic and corticosteroid therapies.
- Open Access
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 14
No ring approach technique for Nd:YAG capsulotomy in pinhole intraocular lenses: mask-sparing strategy to prevent occluder ring damage
Posterior capsule opacification (PCO) is the most common late complication after cataract surgery, with incidence rates influenced by intraocular lens (IOL) material and design. Small-aperture IOLs such as the IC-8 Apthera incorporate a central carbon-black mask that provides extended depth of focus but is highly susceptible to Nd:YAG laser energy. Bench experiments demonstrate that identical pulse settings cause catastrophic mask fragmentation with volumetric material loss, whereas the hydrophobic acrylic periphery shows only microscopic pits. Clinical cases confirm that inadvertent mask hits may induce dysphotopsia and necessitate IOL exchange. The “no ring approach” (NORA) strategy is introduced to prevent such outcomes by confining laser application either within the 1.36 mm central aperture or in the clear peripheral optic while strictly avoiding the 3.23 mm carbon-black mask. Practical recommendations include wide dilation, low initial energy, posterior offset, and careful alignment. Adoption of the NORA technique preserves the optical benefits of pinhole IOLs while enabling safe restoration of vision after PCO.
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 14
Open AccessNo ring approach technique for Nd:YAG capsulotomy in pinhole intraocular lenses: mask-sparing strategy to prevent occluder ring damage
Posterior capsule opacification (PCO) is the most common late complication after cataract surgery, with incidence rates influenced by intraocular lens (IOL) material and design. Small-aperture IOLs such as the IC-8 Apthera incorporate a central carbon-black mask that provides extended depth of focus but is highly susceptible to Nd:YAG laser energy. Bench experiments demonstrate that identical pulse settings cause catastrophic mask fragmentation with volumetric material loss, whereas the hydrophobic acrylic periphery shows only microscopic pits. Clinical cases confirm that inadvertent mask hits may induce dysphotopsia and necessitate IOL exchange. The “no ring approach” (NORA) strategy is introduced to prevent such outcomes by confining laser application either within the 1.36 mm central aperture or in the clear peripheral optic while strictly avoiding the 3.23 mm carbon-black mask. Practical recommendations include wide dilation, low initial energy, posterior offset, and careful alignment. Adoption of the NORA technique preserves the optical benefits of pinhole IOLs while enabling safe restoration of vision after PCO.
- Open Access
- 8 December 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 15 (1) , 479-493
Real-World Validation of the VIVEX Formula for Vitreous Volume Estimation in Vitreoretinal Surgery: A First Clinical Case Series
Background Accurate, patient‑specific estimation of vitreous cavity volume can support planning and safety during vitreoretinal surgery and tamponade procedures. We evaluated the performance of the vitreous volume exact (VIVEX) formula—which predicts vitreous volume from axial length (AL)—in a first clinical case series. Methods This retrospective observational case series included 27 eyes undergoing vitreoretinal procedures. Intraoperative volume measurements (aspirated fluid in group 1 (G1), injected silicone oil in group 2 (G2), and removed silicone oil in group 3 (G3)) were compared with VIVEX‑predicted volumes computed from AL. Accuracy metrics included mean absolute error (MAE) and mean absolute percentage error (MAPE). Agreement was assessed using Pearson correlation, ordinary least-squares regression (slope, intercept, 95% confidence intervals (CIs)), and Bland–Altman analysis. Results Across all eyes (N = 27), VIVEX predictions correlated strongly with intraoperative measurements (r = 0.961, p < 0.0001). Overall, MAE and MAPE were 0.48 mL and 7.43%, respectively. Regression yielded a slope of 0.74 (95% CI 0.65–0.83) and an intercept of 1.17 mL (95% CI 0.60–1.74). Bland–Altman analysis showed a bias of +0.42 mL with 95% limits of agreement from −0.88 to +1.73 mL. Subgroup results were: G1 (n = 17), MAE 0.33 mL and MAPE 6.09%; G2 (n = 5), MAE 0.39 mL and MAPE 6.9%; G3 (n = 5), MAE 1.07 mL and MAPE 12.51%, with a positive bias indicating slightly higher VIVEX values than intraoperative measurements. Conclusions The VIVEX formula demonstrates high correlation and clinically useful accuracy for individualized vitreous volume estimation across common surgical contexts. It seems that the largest error and a positive bias occur during silicone oil removal, warranting caution in oil-filled eyes. In such cases, measurement artifacts due to altered optical pathways in silicone-oil–filled eyes and the possible presence of residual oil remnants after removal may contribute to minor discrepancies between calculated and true intraoperative volumes, indicating a need for further evaluation. Overall, VIVEX may assist preoperative planning and realistic volume targeting in routine practice. As this is the first clinical case series evaluating the VIVEX formula in real surgical settings, larger prospective multicenter studies are needed to confirm and expand the findings.
- 8 December 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 15 (1) , 479-493
Open AccessReal-World Validation of the VIVEX Formula for Vitreous Volume Estimation in Vitreoretinal Surgery: A First Clinical Case Series
Background Accurate, patient‑specific estimation of vitreous cavity volume can support planning and safety during vitreoretinal surgery and tamponade procedures. We evaluated the performance of the vitreous volume exact (VIVEX) formula—which predicts vitreous volume from axial length (AL)—in a first clinical case series. Methods This retrospective observational case series included 27 eyes undergoing vitreoretinal procedures. Intraoperative volume measurements (aspirated fluid in group 1 (G1), injected silicone oil in group 2 (G2), and removed silicone oil in group 3 (G3)) were compared with VIVEX‑predicted volumes computed from AL. Accuracy metrics included mean absolute error (MAE) and mean absolute percentage error (MAPE). Agreement was assessed using Pearson correlation, ordinary least-squares regression (slope, intercept, 95% confidence intervals (CIs)), and Bland–Altman analysis. Results Across all eyes (N = 27), VIVEX predictions correlated strongly with intraoperative measurements (r = 0.961, p < 0.0001). Overall, MAE and MAPE were 0.48 mL and 7.43%, respectively. Regression yielded a slope of 0.74 (95% CI 0.65–0.83) and an intercept of 1.17 mL (95% CI 0.60–1.74). Bland–Altman analysis showed a bias of +0.42 mL with 95% limits of agreement from −0.88 to +1.73 mL. Subgroup results were: G1 (n = 17), MAE 0.33 mL and MAPE 6.09%; G2 (n = 5), MAE 0.39 mL and MAPE 6.9%; G3 (n = 5), MAE 1.07 mL and MAPE 12.51%, with a positive bias indicating slightly higher VIVEX values than intraoperative measurements. Conclusions The VIVEX formula demonstrates high correlation and clinically useful accuracy for individualized vitreous volume estimation across common surgical contexts. It seems that the largest error and a positive bias occur during silicone oil removal, warranting caution in oil-filled eyes. In such cases, measurement artifacts due to altered optical pathways in silicone-oil–filled eyes and the possible presence of residual oil remnants after removal may contribute to minor discrepancies between calculated and true intraoperative volumes, indicating a need for further evaluation. Overall, VIVEX may assist preoperative planning and realistic volume targeting in routine practice. As this is the first clinical case series evaluating the VIVEX formula in real surgical settings, larger prospective multicenter studies are needed to confirm and expand the findings.
- Open Access
- 22 October 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (11) , 1138
Assessing Particle Release from Intraocular Lenses with a Combination of OptoFluidic Force Induction, μ-Raman and μ-FTIR
Intraocular lenses (IOLs) are among the most common medical implants that remain in the body long-term, with millions of IOLs implanted into patients every year. In addition, there are rapidly growing concerns about microplastic pollution, including particle emission from medical implants directly inside the body. Against this backdrop, we analyze the particle emission of seven common types of IOLs over a 30-day period under laboratory conditions. To accomplish both particle counting over a long period and chemical identification, we combine OptoFluidic Force Induction (OF2i), a novel online particle counting method, with micro Fourier Transform Infrared Spectroscopy with Attenuated Total Reflection (μ-FTIR-ATR) and Raman microscopy. Encouragingly, over the 30-day period, no significant particle emission from the IOLs was detectable. Neither was any increase in particle count detectable by OF2i, nor could any particle related to IOL material be found out of over 500 particles analyzed on non-control samples by FTIR and Raman microscopy. The most notable limitation of these results is the 30-day period, which is short compared to the time an IOL stays in the patient, which can be years or even decades. However, two of the tested IOLs were stored in liquid in their original packaging, the analysis of which represents a less-controlled long-term version of our study. Whilst microplastic contamination was found in these liquids, the FTIR and Raman analysis showed that it relates to the packaging materials (PE, PP) rather than the IOLs (acrylic), pointing to a high stability of the IOLs. Future work should try to assess longer time frames with accelerated aging (thermal/UV/oxidative conditions) to approximate long-term in vivo scenarios. Moreover, our findings highlight the need for manufacturers to ensure maximum stability of packaging materials and packaging methods to minimize potential microplastic contamination.
- 22 October 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (11) , 1138
Open AccessAssessing Particle Release from Intraocular Lenses with a Combination of OptoFluidic Force Induction, μ-Raman and μ-FTIR
Intraocular lenses (IOLs) are among the most common medical implants that remain in the body long-term, with millions of IOLs implanted into patients every year. In addition, there are rapidly growing concerns about microplastic pollution, including particle emission from medical implants directly inside the body. Against this backdrop, we analyze the particle emission of seven common types of IOLs over a 30-day period under laboratory conditions. To accomplish both particle counting over a long period and chemical identification, we combine OptoFluidic Force Induction (OF2i), a novel online particle counting method, with micro Fourier Transform Infrared Spectroscopy with Attenuated Total Reflection (μ-FTIR-ATR) and Raman microscopy. Encouragingly, over the 30-day period, no significant particle emission from the IOLs was detectable. Neither was any increase in particle count detectable by OF2i, nor could any particle related to IOL material be found out of over 500 particles analyzed on non-control samples by FTIR and Raman microscopy. The most notable limitation of these results is the 30-day period, which is short compared to the time an IOL stays in the patient, which can be years or even decades. However, two of the tested IOLs were stored in liquid in their original packaging, the analysis of which represents a less-controlled long-term version of our study. Whilst microplastic contamination was found in these liquids, the FTIR and Raman analysis showed that it relates to the packaging materials (PE, PP) rather than the IOLs (acrylic), pointing to a high stability of the IOLs. Future work should try to assess longer time frames with accelerated aging (thermal/UV/oxidative conditions) to approximate long-term in vivo scenarios. Moreover, our findings highlight the need for manufacturers to ensure maximum stability of packaging materials and packaging methods to minimize potential microplastic contamination.
- 12 October 2025
- Published by Taylor & Francis in Current Eye Research
- Vol. 51 (3) , 297-304
Nd:YAG Laser Induced Microfragmentation in Intraocular Lenses: A Correlative Optical and Raman Spectroscopy Study
Neodymium-doped yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy is among the most frequently performed postoperative procedures in pseudophakic patients. Despite its widespread use and generally favorable safety profile, its potential to release solid-phase polymer debris from intraocular lenses (IOLs) has not been fully characterized. In this study, we investigated whether clinically relevant laser settings can cause the liberation of detachable fragments from both hydrophobic and hydrophilic acrylic IOLs. Six commercially available one-piece IOLs were exposed to 2.6 mJ single-pulse Nd:YAG laser shots under standardized in vitro conditions. Microscopic evaluation before and after ultrasonic cleaning was performed. Raman spectroscopy was used to identify the chemical composition of any released fragments. Fragments adjacent to YAG-induced pits were observed in all lens types. Raman spectroscopy confirmed that the fragments matched the chemical signature of the respective IOL material. After sonication and filtration, identical Raman spectra were obtained from fragments retained on gold-coated filters, confirming their origin from the lens surface. Fragment sizes ranged from 10-20 µm. This study demonstrates that solid IOL-derived fragments can be released by standard laser energy levels used in posterior capsulotomy. Although conducted in vitro, the findings raise concerns about the potential clinical relevance of laser-induced material release. Free-floating debris may contribute to straylight, glare, increased intraocular pressure, or inflammatory responses. Further clinical studies are warranted to systematically assess whether such microfragments lead to postoperative complications. Optimized laser parameters and precise focusing are recommended to minimize structural damage and fragment release.
- 12 October 2025
- Published by Taylor & Francis in Current Eye Research
- Vol. 51 (3) , 297-304
Nd:YAG Laser Induced Microfragmentation in Intraocular Lenses: A Correlative Optical and Raman Spectroscopy Study
Neodymium-doped yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy is among the most frequently performed postoperative procedures in pseudophakic patients. Despite its widespread use and generally favorable safety profile, its potential to release solid-phase polymer debris from intraocular lenses (IOLs) has not been fully characterized. In this study, we investigated whether clinically relevant laser settings can cause the liberation of detachable fragments from both hydrophobic and hydrophilic acrylic IOLs. Six commercially available one-piece IOLs were exposed to 2.6 mJ single-pulse Nd:YAG laser shots under standardized in vitro conditions. Microscopic evaluation before and after ultrasonic cleaning was performed. Raman spectroscopy was used to identify the chemical composition of any released fragments. Fragments adjacent to YAG-induced pits were observed in all lens types. Raman spectroscopy confirmed that the fragments matched the chemical signature of the respective IOL material. After sonication and filtration, identical Raman spectra were obtained from fragments retained on gold-coated filters, confirming their origin from the lens surface. Fragment sizes ranged from 10-20 µm. This study demonstrates that solid IOL-derived fragments can be released by standard laser energy levels used in posterior capsulotomy. Although conducted in vitro, the findings raise concerns about the potential clinical relevance of laser-induced material release. Free-floating debris may contribute to straylight, glare, increased intraocular pressure, or inflammatory responses. Further clinical studies are warranted to systematically assess whether such microfragments lead to postoperative complications. Optimized laser parameters and precise focusing are recommended to minimize structural damage and fragment release.
- Open Access
- 24 August 2025
- Published by Springer Nature in Cureus
- Vol. 17 (8)
Neodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) Laser-Induced Damage to Intraocular Lenses: A Systematic Review of Mechanisms, Clinical Consequences, and Preventive Strategies
Neodymium-doped:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy is considered the gold standard treatment for visually significant posterior capsule opacification (PCO), which remains the most common long-term complication following cataract surgery. However, Nd:YAG laser treatment carries the risk of inducing intraocular lens (IOL) damage, including pits, cracks, and optical degradation, particularly affecting the quality of premium hydrophobic acrylic and small-aperture IOLs. To systematically review the morphology, material dependence, optical, and clinical consequences, as well as preventive strategies associated with Nd:YAG laser-induced IOL damage. A comprehensive literature search was conducted in PubMed and Medical Literature Analysis and Retrieval System Online (MEDLINE) databases, including publications from January 1995 to April 2025. Keywords and MeSH terms included "Nd:YAG capsulotomy," "intraocular lens damage," "IOL pits," "posterior capsule opacification," "device-related injuries," and "Yttrium Aluminum Garnet." Peer-reviewed experimental studies, clinical series, case reports, reviews, and guidelines published in English or German were included. Non-peer-reviewed articles, editorials, and conference abstracts were excluded. A total of 53 relevant publications were included following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Morphological alterations ranged from superficial micro-pits to extensive crater formation and delamination, particularly prominent in hydrophobic acrylic and pinhole (small-aperture) IOLs. Experimental studies consistently demonstrated measurable degradation in optical quality, including reduced contrast sensitivity, increased glare, and higher-order aberrations after central pit formation. Clinically, symptomatic IOL damage requiring lens explantation was identified in up to 9.3% of cases analyzed retrospectively. Laboratory analyses, including micro-computed tomography (µCT) and Raman spectroscopy, revealed structural and chemical alterations within damaged areas. Preventive measures proven effective include peripheral laser patterns, posterior offset focusing, minimal effective energy usage (<1.8 mJ), and structured laser alignment techniques. Nd:YAG laser-induced IOL damage significantly depends on material properties, lens design, and laser parameters. Effective preventive strategies, including optimized laser protocols and targeted surgical training, can substantially mitigate these risks. However, robust clinical data linking experimental findings to patient outcomes remain scarce, highlighting the need for large prospective studies in the future, especially focusing on modern premium IOLs. Careful attention seems essential to minimize IOL damage, particularly in premium lens designs, thereby ensuring optimal visual outcomes and patient satisfaction.
- 24 August 2025
- Published by Springer Nature in Cureus
- Vol. 17 (8)
Open AccessNeodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) Laser-Induced Damage to Intraocular Lenses: A Systematic Review of Mechanisms, Clinical Consequences, and Preventive Strategies
Neodymium-doped:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy is considered the gold standard treatment for visually significant posterior capsule opacification (PCO), which remains the most common long-term complication following cataract surgery. However, Nd:YAG laser treatment carries the risk of inducing intraocular lens (IOL) damage, including pits, cracks, and optical degradation, particularly affecting the quality of premium hydrophobic acrylic and small-aperture IOLs. To systematically review the morphology, material dependence, optical, and clinical consequences, as well as preventive strategies associated with Nd:YAG laser-induced IOL damage. A comprehensive literature search was conducted in PubMed and Medical Literature Analysis and Retrieval System Online (MEDLINE) databases, including publications from January 1995 to April 2025. Keywords and MeSH terms included "Nd:YAG capsulotomy," "intraocular lens damage," "IOL pits," "posterior capsule opacification," "device-related injuries," and "Yttrium Aluminum Garnet." Peer-reviewed experimental studies, clinical series, case reports, reviews, and guidelines published in English or German were included. Non-peer-reviewed articles, editorials, and conference abstracts were excluded. A total of 53 relevant publications were included following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Morphological alterations ranged from superficial micro-pits to extensive crater formation and delamination, particularly prominent in hydrophobic acrylic and pinhole (small-aperture) IOLs. Experimental studies consistently demonstrated measurable degradation in optical quality, including reduced contrast sensitivity, increased glare, and higher-order aberrations after central pit formation. Clinically, symptomatic IOL damage requiring lens explantation was identified in up to 9.3% of cases analyzed retrospectively. Laboratory analyses, including micro-computed tomography (µCT) and Raman spectroscopy, revealed structural and chemical alterations within damaged areas. Preventive measures proven effective include peripheral laser patterns, posterior offset focusing, minimal effective energy usage (<1.8 mJ), and structured laser alignment techniques. Nd:YAG laser-induced IOL damage significantly depends on material properties, lens design, and laser parameters. Effective preventive strategies, including optimized laser protocols and targeted surgical training, can substantially mitigate these risks. However, robust clinical data linking experimental findings to patient outcomes remain scarce, highlighting the need for large prospective studies in the future, especially focusing on modern premium IOLs. Careful attention seems essential to minimize IOL damage, particularly in premium lens designs, thereby ensuring optimal visual outcomes and patient satisfaction.
- Open Access
- 4 July 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1450922
Intraocular lens calculation for cataract surgery in high myopia: a case report of an extreme axial eyeball length of 35.7 mm
Extreme axial eyeball length is a known risk factor for decreased accuracy of intraocular lens calculations. We report a case of a 35 years-old male with anisometropic amblyopia and an axial length of 35.7 mm in his right eye. To the best of our knowledge, this is a case of one of the longest eyeballs ever scientifically reported. The patient presented with presenile cataracts in the right eye, hand movement visual acuity, and required cataract surgery. Due to his high anisometropia, he was unable to wear spectacle correction prior to surgery in the amblyopic eye. The left (non-amblyopic) eye had moderate myopia and corrected to 20/20 with no signs of cataracts. Various intraocular lens (IOL) calculations were compared, aiming for a slight postoperative residual myopia in the right eye (approx. −1.50 D). The patient required a minus-power intraocular lens, and an IOL with a larger overall diameter (model 92S “Bigfoot IOL” manufactured by Morcher GmbH, Stuttgart, Germany) was selected. On the last available visit at 6 months, his refractive error was −1.50 to −0.75 D × 179° with a corrected visual acuity of 20/63. The large IOL was stable in the capsular bag, and there were no postoperative complications. The patient was able to wear spectacles with correction in both eyes and reported significant improvement in binocular vision and quality of life. Negative power IOLs typically have different optic configurations and require special considerations during IOL calculation. Care should be taken to avoid postoperative hyperopic refractive error. Nowadays, surgeons can choose from a selection of traditional formulas, newer-generation formulas, and axial length adjustment techniques to improve refractive predictability of eyes with extreme axial myopia. With this case report, we would like to demonstrate that even in rare cases of extreme, high myopia and eyeball length > 35 mm, good results can be achieved with correct IOL power implantation if certain considerations are made prior and during the procedure. Special considerations should be taken into account to maximize patient satisfaction.
- 4 July 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1450922
Open AccessIntraocular lens calculation for cataract surgery in high myopia: a case report of an extreme axial eyeball length of 35.7 mm
Extreme axial eyeball length is a known risk factor for decreased accuracy of intraocular lens calculations. We report a case of a 35 years-old male with anisometropic amblyopia and an axial length of 35.7 mm in his right eye. To the best of our knowledge, this is a case of one of the longest eyeballs ever scientifically reported. The patient presented with presenile cataracts in the right eye, hand movement visual acuity, and required cataract surgery. Due to his high anisometropia, he was unable to wear spectacle correction prior to surgery in the amblyopic eye. The left (non-amblyopic) eye had moderate myopia and corrected to 20/20 with no signs of cataracts. Various intraocular lens (IOL) calculations were compared, aiming for a slight postoperative residual myopia in the right eye (approx. −1.50 D). The patient required a minus-power intraocular lens, and an IOL with a larger overall diameter (model 92S “Bigfoot IOL” manufactured by Morcher GmbH, Stuttgart, Germany) was selected. On the last available visit at 6 months, his refractive error was −1.50 to −0.75 D × 179° with a corrected visual acuity of 20/63. The large IOL was stable in the capsular bag, and there were no postoperative complications. The patient was able to wear spectacles with correction in both eyes and reported significant improvement in binocular vision and quality of life. Negative power IOLs typically have different optic configurations and require special considerations during IOL calculation. Care should be taken to avoid postoperative hyperopic refractive error. Nowadays, surgeons can choose from a selection of traditional formulas, newer-generation formulas, and axial length adjustment techniques to improve refractive predictability of eyes with extreme axial myopia. With this case report, we would like to demonstrate that even in rare cases of extreme, high myopia and eyeball length > 35 mm, good results can be achieved with correct IOL power implantation if certain considerations are made prior and during the procedure. Special considerations should be taken into account to maximize patient satisfaction.
- Open Access
Optical Bench Evaluation of a Novel, Hydrophobic, Acrylic, One-Piece, Polyfocal Intraocular Lens with a “Zig-Zag” L-Loop Haptic Design
Purpose: The number of presbyopia-correcting (premium) intraocular lenses (IOLs) is growing steadily as the desire for spectacle independence after cataract surgery increases. The aim of this laboratory study was to evaluate a newly launched hydrophobic, acrylic, polyfocal, refractive intraocular lens with a new optical design and geometry. This polyfocal IOL has three different zones (within the optic) with radially asymmetric design. Methods: We performed optical bench tests to calculate the optical characteristics of the sample. The optical performance and quality of IOLs based on ISO 11979-2 and 11979-9 requirements were analyzed with the NIMO TR0815 (Lambda-X). In addition, optical quality metrics were evaluated with the IOLA MFD device (Rotlex). Sphere, Add, modulation transfer function (MTF), the energy distribution between the modes and the MTF along the whole range from far to near were analyzed. Results: The power histogram showed that the tested IOL has the characteristics of a polyfocal IOL with a wide range of optical power between 20.5 and 24.5 diopters. Two distinct peaks were observed, indicating bifocal functionality. In the radial and axial power surface map, all three zones, stated by the company, could be detected. Larger apertures lead to a significant increase in MTF at the far peak, indicating better visual acuity for distant objects under low-light conditions. It was observed that in small aperture sizes, intermediate vision seems to be dominant. The energy distribution remained almost constant with increasing aperture size. Conclusions: This laboratory study was able to confirm the properties of the polyfocal lens stated by the company. Three optical zones could be identified. However, further optical bench tests should be performed to evaluate the new lens under tilted and decentered conditions. Clinical studies have to confirm that the presbyopia-correcting, polyfocal lens can achieve good clinical results with high patient satisfaction without disturbing side effects.
Open AccessOptical Bench Evaluation of a Novel, Hydrophobic, Acrylic, One-Piece, Polyfocal Intraocular Lens with a “Zig-Zag” L-Loop Haptic Design
Purpose: The number of presbyopia-correcting (premium) intraocular lenses (IOLs) is growing steadily as the desire for spectacle independence after cataract surgery increases. The aim of this laboratory study was to evaluate a newly launched hydrophobic, acrylic, polyfocal, refractive intraocular lens with a new optical design and geometry. This polyfocal IOL has three different zones (within the optic) with radially asymmetric design. Methods: We performed optical bench tests to calculate the optical characteristics of the sample. The optical performance and quality of IOLs based on ISO 11979-2 and 11979-9 requirements were analyzed with the NIMO TR0815 (Lambda-X). In addition, optical quality metrics were evaluated with the IOLA MFD device (Rotlex). Sphere, Add, modulation transfer function (MTF), the energy distribution between the modes and the MTF along the whole range from far to near were analyzed. Results: The power histogram showed that the tested IOL has the characteristics of a polyfocal IOL with a wide range of optical power between 20.5 and 24.5 diopters. Two distinct peaks were observed, indicating bifocal functionality. In the radial and axial power surface map, all three zones, stated by the company, could be detected. Larger apertures lead to a significant increase in MTF at the far peak, indicating better visual acuity for distant objects under low-light conditions. It was observed that in small aperture sizes, intermediate vision seems to be dominant. The energy distribution remained almost constant with increasing aperture size. Conclusions: This laboratory study was able to confirm the properties of the polyfocal lens stated by the company. Three optical zones could be identified. However, further optical bench tests should be performed to evaluate the new lens under tilted and decentered conditions. Clinical studies have to confirm that the presbyopia-correcting, polyfocal lens can achieve good clinical results with high patient satisfaction without disturbing side effects.
- Open Access
- 9 October 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (12) , 3059-3077
Geometry of Modern Presbyopia-Correcting Intraocular Lenses and Changes in Haptic–Capsular Bag Behavior According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography
Introduction The geometry of an intraocular lens (IOL), the design of the haptics, and the optic–haptic junction play a role in initial and long-term visual outcome after cataract surgery. Knowledge of the behavior of an implant in the capsular bag and under compression is of major importance. Our laboratory experiment analyzed in-depth the geometry of acrylic, single-piece, premium, presbyopia-correcting intraocular lenses and changes in haptic–capsular bag relationships according to capsular bag size using a range of compression well diameters. Methods One hydrophilic (RayOne Trifocal® RAO603F) and three hydrophobic intraocular lenses (AcrySof IQ PanOptix®, Synergy DFR00V™, and AT ELANA 841P®) were scanned with computed tomography (CT) in a dry, uncompressed state for quantitative analyses of haptic and optic–haptic junction (OHJ) dimensions and qualitative assessment of geometry. In the second part of the experiment, CT was performed after sample placement into a series of compression wells (9.0, 10.0, 11.0, 11.5 mm) for analyses of length of contact (LoC) between the haptics and the wells. Axial alignment and haptic–capsular bag relationships were assessed. Results The qualitative and quantitative evaluations highlighted differences in haptic and OHJ geometry and dimensions across the samples. The mid-zone of the optic was thickest in the hydrophilic sample (RayOne Trifocal® RAO603F) with a maximum of 0.880 mm compared to the thinnest hydrophobic sample (AT ELANA 841P®) with 0.564 mm. The AT ELANA 841P® showed the largest OHJ surface area (3.86 mm2) and OHJ volume (0.60 mm3) of the hydrophobic samples. The TECNIS Synergy DFR00V™ showed the thickest OHJ (0.51 mm), while the AcrySof IQ PanOptix® showed the thinnest OHJ (0.21 mm). The LoC values decreased with increasing well size for all tested samples. The AT ELANA 841P® showed the largest LoC and largest contact zones of hydrophobic samples in all wells. Conclusion The laboratory experiments highlight differences in the haptics, the OHJ geometric characteristics, and behavior of samples in different well diameters. The results support the idea that specific IOL designs may have advantages or disadvantages depending on anatomical dimensions. We cannot make any classification or rating (good versus bad) for clinical practice on the basis these experimental results, as many other factors play a role. However, knowledge of IOL geometry seems important to select the best option in each individual case.
- 9 October 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (12) , 3059-3077
Open AccessGeometry of Modern Presbyopia-Correcting Intraocular Lenses and Changes in Haptic–Capsular Bag Behavior According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography
Introduction The geometry of an intraocular lens (IOL), the design of the haptics, and the optic–haptic junction play a role in initial and long-term visual outcome after cataract surgery. Knowledge of the behavior of an implant in the capsular bag and under compression is of major importance. Our laboratory experiment analyzed in-depth the geometry of acrylic, single-piece, premium, presbyopia-correcting intraocular lenses and changes in haptic–capsular bag relationships according to capsular bag size using a range of compression well diameters. Methods One hydrophilic (RayOne Trifocal® RAO603F) and three hydrophobic intraocular lenses (AcrySof IQ PanOptix®, Synergy DFR00V™, and AT ELANA 841P®) were scanned with computed tomography (CT) in a dry, uncompressed state for quantitative analyses of haptic and optic–haptic junction (OHJ) dimensions and qualitative assessment of geometry. In the second part of the experiment, CT was performed after sample placement into a series of compression wells (9.0, 10.0, 11.0, 11.5 mm) for analyses of length of contact (LoC) between the haptics and the wells. Axial alignment and haptic–capsular bag relationships were assessed. Results The qualitative and quantitative evaluations highlighted differences in haptic and OHJ geometry and dimensions across the samples. The mid-zone of the optic was thickest in the hydrophilic sample (RayOne Trifocal® RAO603F) with a maximum of 0.880 mm compared to the thinnest hydrophobic sample (AT ELANA 841P®) with 0.564 mm. The AT ELANA 841P® showed the largest OHJ surface area (3.86 mm2) and OHJ volume (0.60 mm3) of the hydrophobic samples. The TECNIS Synergy DFR00V™ showed the thickest OHJ (0.51 mm), while the AcrySof IQ PanOptix® showed the thinnest OHJ (0.21 mm). The LoC values decreased with increasing well size for all tested samples. The AT ELANA 841P® showed the largest LoC and largest contact zones of hydrophobic samples in all wells. Conclusion The laboratory experiments highlight differences in the haptics, the OHJ geometric characteristics, and behavior of samples in different well diameters. The results support the idea that specific IOL designs may have advantages or disadvantages depending on anatomical dimensions. We cannot make any classification or rating (good versus bad) for clinical practice on the basis these experimental results, as many other factors play a role. However, knowledge of IOL geometry seems important to select the best option in each individual case.
- Open Access
- 17 August 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (10) , 2745-2758
Incorrectly Focused Neodymium:Yttrium–Aluminum-Garnet (Nd:YAG) Laser Beam Leads to Massive Destructive Effects in Small-Aperture (Pinhole) Intraocular Lenses
Introduction Pinhole intraocular lenses (IOLs) were developed to improve reading by compensating for loss of accommodative function. The IC-8® Apthera™ is a small-aperture presbyopia-correcting IOL that combines the proven principle of small-aperture optics with an aspheric monofocal lens to deliver a continuous range of vision for patients with cataracts from distance to near vision. Posterior capsule opacification is the most common sequela after cataract surgery. It is effectively treated by laser capsulotomy. However, if the laser beam is incorrectly focused, the IOL can be permanently damaged (pits/shots). Methods In this experimental study, yttrium–aluminum-garnet (YAG) pits were purposefully created. Defects were analyzed and compared between the periphery of the ring in the clear area of the hydrophobic acrylic lens and at the carbon black (CB)-polyvinylidene fluoride (PVDF) filtering component (FilterRing™) of the pinhole lens. All defects were made using identical settings/energy levels (2.6 mJ). The damage induced to the IC-8® Apthera™ IOL was examined by low-magnification images, light microscopy, scanning electron microscopy, and micro-computed tomography (micro-CT). Results YAG defects in the carbon black filter ring were much more severe than those in the clear zone due to the high absorption of the carbon black. Massive defects and destruction of the lens with tearing out of fragments and particles were observed. The missing volume calculated from the micro-CT reconstruction was 0.266 mm3, which is 1.6% of the entire IOL volume, or more than 1000 times the volume damaged in the largest shot in the periphery. Conclusion Based on the results, we highly recommend using the lowest possible energy levels, posterior offset setting, and circular pattern for maximum safety when performing laser capsulotomy with pinhole implants. Care should be taken to avoid creating irreversible iatrogenic defects that may affect overall quality. The safest area for performing capsulotomy seems to be the periphery of the ring segment. Video available for this article.
- 17 August 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (10) , 2745-2758
Open AccessIncorrectly Focused Neodymium:Yttrium–Aluminum-Garnet (Nd:YAG) Laser Beam Leads to Massive Destructive Effects in Small-Aperture (Pinhole) Intraocular Lenses
Introduction Pinhole intraocular lenses (IOLs) were developed to improve reading by compensating for loss of accommodative function. The IC-8® Apthera™ is a small-aperture presbyopia-correcting IOL that combines the proven principle of small-aperture optics with an aspheric monofocal lens to deliver a continuous range of vision for patients with cataracts from distance to near vision. Posterior capsule opacification is the most common sequela after cataract surgery. It is effectively treated by laser capsulotomy. However, if the laser beam is incorrectly focused, the IOL can be permanently damaged (pits/shots). Methods In this experimental study, yttrium–aluminum-garnet (YAG) pits were purposefully created. Defects were analyzed and compared between the periphery of the ring in the clear area of the hydrophobic acrylic lens and at the carbon black (CB)-polyvinylidene fluoride (PVDF) filtering component (FilterRing™) of the pinhole lens. All defects were made using identical settings/energy levels (2.6 mJ). The damage induced to the IC-8® Apthera™ IOL was examined by low-magnification images, light microscopy, scanning electron microscopy, and micro-computed tomography (micro-CT). Results YAG defects in the carbon black filter ring were much more severe than those in the clear zone due to the high absorption of the carbon black. Massive defects and destruction of the lens with tearing out of fragments and particles were observed. The missing volume calculated from the micro-CT reconstruction was 0.266 mm3, which is 1.6% of the entire IOL volume, or more than 1000 times the volume damaged in the largest shot in the periphery. Conclusion Based on the results, we highly recommend using the lowest possible energy levels, posterior offset setting, and circular pattern for maximum safety when performing laser capsulotomy with pinhole implants. Care should be taken to avoid creating irreversible iatrogenic defects that may affect overall quality. The safest area for performing capsulotomy seems to be the periphery of the ring segment. Video available for this article.