Kentaro Doi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kentaro Doi has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Satoyuki Kawano
Graduate School of Engineering Science, The University of Osaka, Toyonaka, Japan
31 shared publications Satoyuki Kawano
Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531, Japan
11 shared publicationsFumika Nito
7 shared publicationsAyako Yano
Division of Mechanical Science and Technology, Faculty of Science and Technology, Gunma University
5 shared publications- Tetsuro Tsuji
Kyoto University
5 shared publications Tatsunori Kishimoto
4 shared publications
Latest Publications
- Open Access
- 20 August 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Electrostatic and hydrodynamic modulation of resistive pulse waveforms for nanoparticle sensing
- 20 August 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessElectrostatic and hydrodynamic modulation of resistive pulse waveforms for nanoparticle sensing
- 1 December 2025
- Published by IOP Publishing in Nanotechnology
- Vol. 36 (49) , 495101
Two-dimensional rotational manipulation of nanoparticles on lipid bilayers with an optical vortex beam
Optical trapping is a non-invasive technique for manipulating nano- and microscopic objects and is widely used to investigate biological processes, such as membrane viscosity, membrane–cytoskeleton interactions, and the regulation of cellular functions. Optical vortex beams can maintain orbital angular momentum (OAM) and have recently been used for optical manipulation. When nanoparticles in aqueous solutions are rotated at the laser focus owing to the optical forces derived from the optical vortex beam, their subsequent motion is governed by the OAM. The dynamics of nanoparticles attached to the biological membrane may be further affected by the viscoelasticity of the membrane and hydrodynamic coupling; however, it is unclear whether such rotational motion on lipid bilayers can be controlled. In this study, we applied an optical vortex beam to the two-dimensional rotational manipulation of fluorescent nanoparticles attached to a supporting lipid bilayer (SLB) and investigated their rotational behavior. We revealed that the single nanoparticles attached to the SLB rotated more slowly than those in an aqueous solution, but their orbital motion was still clearly driven by the OAM of the beam. The orbital radius of rotation was tuned according to the magnitude of the topological charge, and an angle velocity that changed linearly in proportion to both the laser power and nanoparticle diffusion coefficient was identified, which was consistent with theoretical calculations. These results suggest that optical vortex beams can manipulate nanoparticles attached to SLB with controllable rotational dynamics. Such rotational manipulation of nanoparticles on lipid bilayers can provide a platform for studying the effects of nanoparticle rotation on the local organization of membrane components and can be useful for developing methods to regulate their dynamic properties.
- 1 December 2025
- Published by IOP Publishing in Nanotechnology
- Vol. 36 (49) , 495101
Two-dimensional rotational manipulation of nanoparticles on lipid bilayers with an optical vortex beam
Optical trapping is a non-invasive technique for manipulating nano- and microscopic objects and is widely used to investigate biological processes, such as membrane viscosity, membrane–cytoskeleton interactions, and the regulation of cellular functions. Optical vortex beams can maintain orbital angular momentum (OAM) and have recently been used for optical manipulation. When nanoparticles in aqueous solutions are rotated at the laser focus owing to the optical forces derived from the optical vortex beam, their subsequent motion is governed by the OAM. The dynamics of nanoparticles attached to the biological membrane may be further affected by the viscoelasticity of the membrane and hydrodynamic coupling; however, it is unclear whether such rotational motion on lipid bilayers can be controlled. In this study, we applied an optical vortex beam to the two-dimensional rotational manipulation of fluorescent nanoparticles attached to a supporting lipid bilayer (SLB) and investigated their rotational behavior. We revealed that the single nanoparticles attached to the SLB rotated more slowly than those in an aqueous solution, but their orbital motion was still clearly driven by the OAM of the beam. The orbital radius of rotation was tuned according to the magnitude of the topological charge, and an angle velocity that changed linearly in proportion to both the laser power and nanoparticle diffusion coefficient was identified, which was consistent with theoretical calculations. These results suggest that optical vortex beams can manipulate nanoparticles attached to SLB with controllable rotational dynamics. Such rotational manipulation of nanoparticles on lipid bilayers can provide a platform for studying the effects of nanoparticle rotation on the local organization of membrane components and can be useful for developing methods to regulate their dynamic properties.
- Open Access
- 1 April 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (4)
Direct sensing of temperature dependence of electric field and conductivity of liquids using glass microelectrodes
In recent years, ionic current analyses for liquid environments have attracted significant attention. Ionic responses obtained from confined small spaces provide information and new findings from the viewpoint of micro- and nano-scales. Signals in such small spaces are weak and often disturbed by noise, and thus, the measurement technique in liquids has been an important issue. Herein, we have developed a novel technique to directly measure the electric field in a small test section, which enables us to determine the electrical conductivity and concentration. Upon scanning a glass microelectrode, the spatial distribution of the electric field is visualized. In this study, the temperature dependence of electrical conductivity is analyzed by scanning the electric field in the temperature range from 303 to 333 K, using LiCl, NaCl, and KCl solutions. The relationship between the electric field, conductivity, and viscosity of liquids is discussed. In summary, the glass microelectrode technique has been shown to enable quantitative analysis of the physical properties of liquids from spatially localized temperature-dependent quantities.
- 1 April 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (4)
Open AccessDirect sensing of temperature dependence of electric field and conductivity of liquids using glass microelectrodes
In recent years, ionic current analyses for liquid environments have attracted significant attention. Ionic responses obtained from confined small spaces provide information and new findings from the viewpoint of micro- and nano-scales. Signals in such small spaces are weak and often disturbed by noise, and thus, the measurement technique in liquids has been an important issue. Herein, we have developed a novel technique to directly measure the electric field in a small test section, which enables us to determine the electrical conductivity and concentration. Upon scanning a glass microelectrode, the spatial distribution of the electric field is visualized. In this study, the temperature dependence of electrical conductivity is analyzed by scanning the electric field in the temperature range from 303 to 333 K, using LiCl, NaCl, and KCl solutions. The relationship between the electric field, conductivity, and viscosity of liquids is discussed. In summary, the glass microelectrode technique has been shown to enable quantitative analysis of the physical properties of liquids from spatially localized temperature-dependent quantities.
- Open Access
- 1 January 2025
- Published by Japan Society of Mechanical Engineers in Mechanical Engineering Journal
- Vol. 12 (4) , 25-00036
Separation and trapping of nanoparticles using pressure-driven flow and electrokinetic transport in micro- and nanochannels
Recently, detection and separation techniques of micro- and nanoparticles using micro- and nanofluidic channels have been developed. Especially, micro- and nanoplastics have attracted significant attention as pollutants of the water environment. On the other hand, it is known that the separation and recovery of nanoobjects that widely disperse in water are quite difficult. In this study, we investigate the behavior of nanoparticles in nanochannels where nanoparticle transport driven by pressure-driven flow is modified by electrostatic force and electroosmotic flow. Furthermore, nanoparticles are effectively separated by size and captured in the nanochannel by the balance between the Stokes drag and the electrostatic forces acting on particles passing through the nanochannel. The present methods are expected to be one of effective methods for separation, condensation, and recovery of nanoplastics from wastewater as well as transport velocity control for single particle analysis.
- 1 January 2025
- Published by Japan Society of Mechanical Engineers in Mechanical Engineering Journal
- Vol. 12 (4) , 25-00036
Open AccessSeparation and trapping of nanoparticles using pressure-driven flow and electrokinetic transport in micro- and nanochannels
Recently, detection and separation techniques of micro- and nanoparticles using micro- and nanofluidic channels have been developed. Especially, micro- and nanoplastics have attracted significant attention as pollutants of the water environment. On the other hand, it is known that the separation and recovery of nanoobjects that widely disperse in water are quite difficult. In this study, we investigate the behavior of nanoparticles in nanochannels where nanoparticle transport driven by pressure-driven flow is modified by electrostatic force and electroosmotic flow. Furthermore, nanoparticles are effectively separated by size and captured in the nanochannel by the balance between the Stokes drag and the electrostatic forces acting on particles passing through the nanochannel. The present methods are expected to be one of effective methods for separation, condensation, and recovery of nanoplastics from wastewater as well as transport velocity control for single particle analysis.
- Open Access
- 25 December 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3896
Fluid–Structure Interaction Analysis of Trapezoidal and Arc‐Shaped Membranes Mimicking the Organ of Corti
In a previous study [H. Shintaku et al., Sensors and Actuators A: Physical 158 (2010): 183–192], an artificially developed auditory sensor device showed a frequency selectivity in the range from 6.6 to 19.8 kHz in air and from 1.4 to 4.9 kHz in liquid. Furthermore, the sensor succeeded in obtaining auditory brain‐stem responses in deafened guinea pigs [T. Inaoka et al., Proceedings of the National Academy of Sciences of the United States of America 108 (2011): 18390–18395]. Since then, several research groups have developed piezoelectric auditory devices that have the capability of acoustic/electric conversion. However, the piezoelectric devices are required to be optimally designed with respect to the frequency range in liquids. In the present study, focusing on the trapezoidal shape of the piezoelectric membrane, the vibration characteristics are numerically and experimentally investigated. In the numerical analysis, solving a three‐dimensional fluid‐structure interaction problem, resonant frequencies of the trapezoidal membrane are evaluated. Herein, Young's modulus of the membrane, which is made of polyvinylidene difluoride and is different from that of bulk, is properly determined to reproduce the experimental results measured in air. Using the modified elastic modulus for the membrane, the vibration modes and resonant frequencies in liquid are in good agreement with experimental results. It is also found that the resonant characteristics of the artificial basilar membrane for guinea pigs are quantitatively reproduced, considering the fluid–structure interaction. The present numerical method predicts experimental results and is available to improve the frequency selectivity of the piezoelectric membranes for artificial cochlear devices.
- 25 December 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3896
Open AccessFluid–Structure Interaction Analysis of Trapezoidal and Arc‐Shaped Membranes Mimicking the Organ of Corti
In a previous study [H. Shintaku et al., Sensors and Actuators A: Physical 158 (2010): 183–192], an artificially developed auditory sensor device showed a frequency selectivity in the range from 6.6 to 19.8 kHz in air and from 1.4 to 4.9 kHz in liquid. Furthermore, the sensor succeeded in obtaining auditory brain‐stem responses in deafened guinea pigs [T. Inaoka et al., Proceedings of the National Academy of Sciences of the United States of America 108 (2011): 18390–18395]. Since then, several research groups have developed piezoelectric auditory devices that have the capability of acoustic/electric conversion. However, the piezoelectric devices are required to be optimally designed with respect to the frequency range in liquids. In the present study, focusing on the trapezoidal shape of the piezoelectric membrane, the vibration characteristics are numerically and experimentally investigated. In the numerical analysis, solving a three‐dimensional fluid‐structure interaction problem, resonant frequencies of the trapezoidal membrane are evaluated. Herein, Young's modulus of the membrane, which is made of polyvinylidene difluoride and is different from that of bulk, is properly determined to reproduce the experimental results measured in air. Using the modified elastic modulus for the membrane, the vibration modes and resonant frequencies in liquid are in good agreement with experimental results. It is also found that the resonant characteristics of the artificial basilar membrane for guinea pigs are quantitatively reproduced, considering the fluid–structure interaction. The present numerical method predicts experimental results and is available to improve the frequency selectivity of the piezoelectric membranes for artificial cochlear devices.
- Open Access
- 25 May 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 698
Micro- and Nanofluidic pH Sensors Based on Electrodiffusioosmosis
Recently, various kinds of micro- and nanofluidic functional devices have been proposed, where a large surface-to-volume ratio often plays an important role in nanoscale ion transport phenomena. Ionic current analysis methods for ions, molecules, nanoparticles, and biological cells have attracted significant attention. In this study, focusing on ionic current rectification (ICR) caused by the separation of cation and anion transport in nanochannels, we successfully induce electrodiffusioosmosis with concentration differences between protons separated by nanochannels. The proton concentration in sample solutions is quantitatively evaluated in the range from pH 1.68 to 10.01 with a slope of 243 mV/pH at a galvanostatic current of 3 nA. Herein, three types of micro- and nanochannels are proposed to improve the stability and measurement accuracy of the current–voltage characteristics, and the ICR effects on pH analysis are evaluated. It is found that a nanochannel filled with polyethylene glycol exhibits increased impedance and an improved ICR ratio. The present principle is expected to be applicable to various types of ions.
- 25 May 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 698
Open AccessMicro- and Nanofluidic pH Sensors Based on Electrodiffusioosmosis
Recently, various kinds of micro- and nanofluidic functional devices have been proposed, where a large surface-to-volume ratio often plays an important role in nanoscale ion transport phenomena. Ionic current analysis methods for ions, molecules, nanoparticles, and biological cells have attracted significant attention. In this study, focusing on ionic current rectification (ICR) caused by the separation of cation and anion transport in nanochannels, we successfully induce electrodiffusioosmosis with concentration differences between protons separated by nanochannels. The proton concentration in sample solutions is quantitatively evaluated in the range from pH 1.68 to 10.01 with a slope of 243 mV/pH at a galvanostatic current of 3 nA. Herein, three types of micro- and nanochannels are proposed to improve the stability and measurement accuracy of the current–voltage characteristics, and the ICR effects on pH analysis are evaluated. It is found that a nanochannel filled with polyethylene glycol exhibits increased impedance and an improved ICR ratio. The present principle is expected to be applicable to various types of ions.
- Open Access
- 17 May 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
High-throughput mechanical phenotyping and transcriptomics of single cells
The molecular system regulating cellular mechanical properties remains unexplored at single-cell resolution mainly due to a limited ability to combine mechanophenotyping with unbiased transcriptional screening. Here, we describe an electroporation-based lipid-bilayer assay for cell surface tension and transcriptomics (ELASTomics), a method in which oligonucleotide-labelled macromolecules are imported into cells via nanopore electroporation to assess the mechanical state of the cell surface and are enumerated by sequencing. ELASTomics can be readily integrated with existing single-cell sequencing approaches and enables the joint study of cell surface mechanics and underlying transcriptional regulation at an unprecedented resolution. We validate ELASTomics via analysis of cancer cell lines from various malignancies and show that the method can accurately identify cell types and assess cell surface tension. ELASTomics enables exploration of the relationships between cell surface tension, surface proteins, and transcripts along cell lineages differentiating from the haematopoietic progenitor cells of mice. We study the surface mechanics of cellular senescence and demonstrate that RRAD regulates cell surface tension in senescent TIG-1 cells. ELASTomics provides a unique opportunity to profile the mechanical and molecular phenotypes of single cells and can dissect the interplay among these in a range of biological contexts.
- 17 May 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Open AccessHigh-throughput mechanical phenotyping and transcriptomics of single cells
The molecular system regulating cellular mechanical properties remains unexplored at single-cell resolution mainly due to a limited ability to combine mechanophenotyping with unbiased transcriptional screening. Here, we describe an electroporation-based lipid-bilayer assay for cell surface tension and transcriptomics (ELASTomics), a method in which oligonucleotide-labelled macromolecules are imported into cells via nanopore electroporation to assess the mechanical state of the cell surface and are enumerated by sequencing. ELASTomics can be readily integrated with existing single-cell sequencing approaches and enables the joint study of cell surface mechanics and underlying transcriptional regulation at an unprecedented resolution. We validate ELASTomics via analysis of cancer cell lines from various malignancies and show that the method can accurately identify cell types and assess cell surface tension. ELASTomics enables exploration of the relationships between cell surface tension, surface proteins, and transcripts along cell lineages differentiating from the haematopoietic progenitor cells of mice. We study the surface mechanics of cellular senescence and demonstrate that RRAD regulates cell surface tension in senescent TIG-1 cells. ELASTomics provides a unique opportunity to profile the mechanical and molecular phenotypes of single cells and can dissect the interplay among these in a range of biological contexts.
- Open Access
- 21 December 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 128 (1) , 346-354
pH Sensing Based on Ionic Current Rectification Using Triple-Barreled Glass Microelectrodes
- 21 December 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 128 (1) , 346-354
Open AccesspH Sensing Based on Ionic Current Rectification Using Triple-Barreled Glass Microelectrodes
- Open Access
- 21 October 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (43) , 39437-39445
Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
Transport phenomena in microfluidic chips are induced by electric fields and electrolyte concentrations. Liquid flows are often affected by ionic currents driven by electric fields in narrow channels, which are applied in microelectromechanical systems, microreactors, lab-on-a-chip, and so forth. Even though numerical studies to evaluate those local fields have been reported, measurement methods seem to be under construction. To deeply understand the dynamics of ions at the microscale, measurement techniques are necessary to be developed. In this study, we propose a novel method to directly measure electrical potential differences in liquids, local electric fields, and electrical conductivities, using a glass microelectrode. Scanning an electrolyte solution, for example, KCl solutions, with a 1 μm tip under constant ionic current conditions, a potential difference in liquids is locally measured with a micrometer-scale resolution. The conductivity of KCl solutions ranging from 0.56 to 100 mM is evaluated from electric fields locally measured, and errors are within 5% compared with the reference values. It is found that the present method enables us to directly measure local electric fields under constant current and that the electrical conductivity is quantitatively evaluated. Furthermore, it is suggested that the present method is available for various electrical analyses without calibration procedures before measurements.
- 21 October 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (43) , 39437-39445
Open AccessLocal Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
Transport phenomena in microfluidic chips are induced by electric fields and electrolyte concentrations. Liquid flows are often affected by ionic currents driven by electric fields in narrow channels, which are applied in microelectromechanical systems, microreactors, lab-on-a-chip, and so forth. Even though numerical studies to evaluate those local fields have been reported, measurement methods seem to be under construction. To deeply understand the dynamics of ions at the microscale, measurement techniques are necessary to be developed. In this study, we propose a novel method to directly measure electrical potential differences in liquids, local electric fields, and electrical conductivities, using a glass microelectrode. Scanning an electrolyte solution, for example, KCl solutions, with a 1 μm tip under constant ionic current conditions, a potential difference in liquids is locally measured with a micrometer-scale resolution. The conductivity of KCl solutions ranging from 0.56 to 100 mM is evaluated from electric fields locally measured, and errors are within 5% compared with the reference values. It is found that the present method enables us to directly measure local electric fields under constant current and that the electrical conductivity is quantitatively evaluated. Furthermore, it is suggested that the present method is available for various electrical analyses without calibration procedures before measurements.
- Open Access
- 24 June 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (26) , 10713-10721
Micro-to-Nano Bimodal Single-Particle Sensing Using Optical Tweezers
- 24 June 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (26) , 10713-10721
Open AccessMicro-to-Nano Bimodal Single-Particle Sensing Using Optical Tweezers