Josefina María Silveyra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Josefina María Silveyra has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Juan Manuel Conde Garrido
Universidad de Buenos Aires, Facultad de Ingeniería, Laboratorio de Sólidos Amorfos/Laboratorio de Ablación Láser and CONICET - Universidad de Buenos Aires, Instituto de Tecnologías y Ciencias de la Ingeniería “Hilario Fernández Long” (INTECIN); Av. Paseo Colón 850, CP: 1063, Buenos Aires, Argentina
6 shared publications - Peter Svec
Institute of Physics, Slovak Academy of Sciences, 845 11 Bratislava, Slovakia
6 shared publications Victoria J. Cremaschi
INTECIN, FIUBA-CONICET
6 shared publications- Dusan Janickovic
Institute of Physics, Slovak Academy of Sciences
3 shared publications Dušan Janičkovič
Institute of Physics SAS, Dúbravská cesta 9, 845 11 Bratislava, Slovak Republic
3 shared publicationsEmília Illeková
3 shared publications
Latest Publications
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (1) , 1-11
Blind Efficient Method for Optimizing Jiles–Atherton Model Parameters
We introduce a novel blind optimization method for determining the parameters of the Jiles–Atherton model of hysteresis, eliminating the need for user-provided initial guesses or search spaces. A carefully designed initialization procedure combined with a standard optimizer yields a high-performing, practical method for parameter estimation. Validation against a theoretical benchmark recovers ground-truth parameters in under half a minute with negligible error (relative error < 4 $\times$ 10−8). When applied to the TEAM32 electrical steel experimental benchmark, our method achieved superior accuracy than previously reported fittings, also converging in under half a minute. Consistently robust performance is further demonstrated across diverse systems, including soft ferrites, nanocrystalline alloys, and magnetostrictive compounds. The presented blind approach offers new insights into magnetic material characterization and is deployed as an automated tool for hysteresis analysis. It advances both fundamental understanding and practical applications by demonstrating the Jiles–Atherton model’s capability to describe anisotropic materials and by revealing its inherent limitations.
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (1) , 1-11
Blind Efficient Method for Optimizing Jiles–Atherton Model Parameters
We introduce a novel blind optimization method for determining the parameters of the Jiles–Atherton model of hysteresis, eliminating the need for user-provided initial guesses or search spaces. A carefully designed initialization procedure combined with a standard optimizer yields a high-performing, practical method for parameter estimation. Validation against a theoretical benchmark recovers ground-truth parameters in under half a minute with negligible error (relative error < 4 $\times$ 10−8). When applied to the TEAM32 electrical steel experimental benchmark, our method achieved superior accuracy than previously reported fittings, also converging in under half a minute. Consistently robust performance is further demonstrated across diverse systems, including soft ferrites, nanocrystalline alloys, and magnetostrictive compounds. The presented blind approach offers new insights into magnetic material characterization and is deployed as an automated tool for hysteresis analysis. It advances both fundamental understanding and practical applications by demonstrating the Jiles–Atherton model’s capability to describe anisotropic materials and by revealing its inherent limitations.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (9) , 1-6
MagAnalyst: A MATLAB Toolbox for Anhysteretic Magnetization Analysis
We introduce MagAnalyst, a user-friendly MATLAB toolbox designed to streamline the fitting process of anhysteretic magnetization curves using the Langevin–Weiss equation of state. Built upon the framework proposed by Silveyra and Conde Garrido, our toolbox facilitates the description of magnetically anisotropic materials through negative molecular fields and magnetically inhomogeneous materials through multicomponent magnetizations. This study showcases the reliability and accuracy of MagAnalyst, enabling the direct extraction of key parameters such as the anisotropy mean field and the induced anisotropy energy constant. By making this toolbox freely available at https://github.com/matias-gonz/maganalyst/ , we aim to provide a valuable tool for comprehending the magnetic properties of soft magnets, thereby contributing to the development of cutting-edge magnetic devices.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (9) , 1-6
MagAnalyst: A MATLAB Toolbox for Anhysteretic Magnetization Analysis
We introduce MagAnalyst, a user-friendly MATLAB toolbox designed to streamline the fitting process of anhysteretic magnetization curves using the Langevin–Weiss equation of state. Built upon the framework proposed by Silveyra and Conde Garrido, our toolbox facilitates the description of magnetically anisotropic materials through negative molecular fields and magnetically inhomogeneous materials through multicomponent magnetizations. This study showcases the reliability and accuracy of MagAnalyst, enabling the direct extraction of key parameters such as the anisotropy mean field and the induced anisotropy energy constant. By making this toolbox freely available at https://github.com/matias-gonz/maganalyst/ , we aim to provide a valuable tool for comprehending the magnetic properties of soft magnets, thereby contributing to the development of cutting-edge magnetic devices.
- 16 September 2023
- Published by Elsevier in Finite Elements in Analysis and Design
- Vol. 227, 104042
Torque calculation method for axial-flux electrical machines in finite element analysis
- 16 September 2023
- Published by Elsevier in Finite Elements in Analysis and Design
- Vol. 227, 104042
Torque calculation method for axial-flux electrical machines in finite element analysis
- 22 February 2023
- Published by Springer Nature in JOM
- Vol. 75 (6) , 1810-1823
A Physically Based Model for Soft Magnets’ Anhysteretic Curve
- 22 February 2023
- Published by Springer Nature in JOM
- Vol. 75 (6) , 1810-1823
A Physically Based Model for Soft Magnets’ Anhysteretic Curve
- 1 May 2022
- Published by American Association of Physics Teachers (AAPT) in American Journal of Physics
- Vol. 90 (5) , 365-372
Electrically connected and magnetically coupled inductors: Aiding or opposing fluxes?
Representing components combined in series or parallel as a single equivalent component is a powerful tool for simplifying systems, both in mechanics and in electrical circuits. When combining inductors, the effect of mutual inductance decreases or increases the total inductance of the system, depending on the coupling factor between the inductors and on how they are connected. The analysis of mutually coupled inductors can be complex and is often avoided, obscuring the underlying physics. Here, we discuss the dependence of the equivalent inductance on the coupling factor for two parallel-connected inductors with linear magnetic core and negligible resistance. By analyzing the current distribution in each coil, we show that the so-called aiding and opposing arrangements are more complicated than is frequently assumed. We recommend avoiding these terms and calling them instead aligned and anti-aligned arrangements.
- 1 May 2022
- Published by American Association of Physics Teachers (AAPT) in American Journal of Physics
- Vol. 90 (5) , 365-372
Electrically connected and magnetically coupled inductors: Aiding or opposing fluxes?
Representing components combined in series or parallel as a single equivalent component is a powerful tool for simplifying systems, both in mechanics and in electrical circuits. When combining inductors, the effect of mutual inductance decreases or increases the total inductance of the system, depending on the coupling factor between the inductors and on how they are connected. The analysis of mutually coupled inductors can be complex and is often avoided, obscuring the underlying physics. Here, we discuss the dependence of the equivalent inductance on the coupling factor for two parallel-connected inductors with linear magnetic core and negligible resistance. By analyzing the current distribution in each coil, we show that the so-called aiding and opposing arrangements are more complicated than is frequently assumed. We recommend avoiding these terms and calling them instead aligned and anti-aligned arrangements.
- Open Access
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035019
On the anhysteretic magnetization of soft magnetic materials
Electrical steels are still the materials of choice for large-scale transformers and most electric motors. Yet, they may present a nonhomogeneous magnetic nature which prevents describing accurately their anhysteretic magnetization with the Langevin-Weiss model. Although interpolation and extrapolation methods may be used to model any anhysteretic curve, a simple and physically-based model would be of great value for fundamental and applied research. Inspired in the law of partial volumes for gas mixtures, we proposed a law of partial magnetizations for magnetic mixtures. In a two-component system, the model leads to the double Langevin-Weiss function. We also introduced a graphical method and a fitting approach to analyze and model anhysteretic magnetization curves. A semi-log magnetization derivative plot is central to this end. We validated our strategy through well-motivated examples using published data on soft magnets. The single Langevin-Weiss function provided an accurate description of the magnetization of isotropic and anisotropic magnetically homogeneous materials: a soft ferrite and a nanocrystalline alloy, respectively. For modelling a magnetization transverse to the material’s preferred direction, the key is to allow a negative molecular field constant. The double Langevin-Weiss function was suitable for less homogeneous materials, such as a grain-oriented electrical steel magnetized along the rolling direction and a non-oriented electrical steel. Moreover, a highly-grain-oriented electrical steel magnetized transverse to the rolling direction, which exhibits a constricted hysteresis loop, could be modeled in excellent agreement with data. The key for the latter, has been to allow an antiparallel arrangement of the mean magnetization of both components.
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035019
Open AccessOn the anhysteretic magnetization of soft magnetic materials
Electrical steels are still the materials of choice for large-scale transformers and most electric motors. Yet, they may present a nonhomogeneous magnetic nature which prevents describing accurately their anhysteretic magnetization with the Langevin-Weiss model. Although interpolation and extrapolation methods may be used to model any anhysteretic curve, a simple and physically-based model would be of great value for fundamental and applied research. Inspired in the law of partial volumes for gas mixtures, we proposed a law of partial magnetizations for magnetic mixtures. In a two-component system, the model leads to the double Langevin-Weiss function. We also introduced a graphical method and a fitting approach to analyze and model anhysteretic magnetization curves. A semi-log magnetization derivative plot is central to this end. We validated our strategy through well-motivated examples using published data on soft magnets. The single Langevin-Weiss function provided an accurate description of the magnetization of isotropic and anisotropic magnetically homogeneous materials: a soft ferrite and a nanocrystalline alloy, respectively. For modelling a magnetization transverse to the material’s preferred direction, the key is to allow a negative molecular field constant. The double Langevin-Weiss function was suitable for less homogeneous materials, such as a grain-oriented electrical steel magnetized along the rolling direction and a non-oriented electrical steel. Moreover, a highly-grain-oriented electrical steel magnetized transverse to the rolling direction, which exhibits a constricted hysteresis loop, could be modeled in excellent agreement with data. The key for the latter, has been to allow an antiparallel arrangement of the mean magnetization of both components.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 25 (3)
Sobre los materiales de encapsulado para electrodos selectivos de iones
RESUMEN Los electrodos selectivos de iones (ISEs) con membranas de vidrios calcogenuros son sensores capaces de detectar iones de metales pesados en soluciones electrolíticas. Su uso in-situ y repetido plantea grandes desafíos a la selección del material para encapsular la membrana sensible. La falla en el encapsulado inutiliza al sensor, que debe ser descartado. Sin embargo, no existe hasta ahora estudios reportados sobre este componente crítico de los sensores. El material encapsulante debe aislar al contacto eléctrico de la solución circundante, tener un bajo nivel de absorción de la solución y de los iones en solución, así como mantener sus propiedades invariables por largos períodos de tiempo. Los requisitos del material dependerán también de la geometría de la membrana, ya sea en bulk o en forma de película delgada. Con el fin de facilitar nuevas investigaciones en la temática de los ISEs, estudiamos cinco materiales encapsulantes disponibles comercialmente en la región latinoamericana (Poxipol transparente, Vaicel, Wilpox APV 3C, Wilpox Doming P-5 y Araldite CY-248 + HY-956). Analizamos los requisitos de estabilidad y confiabilidad evaluando las siguientes propiedades: viscosidad, tiempo de curado, dureza, calidad superficial, formación de burbujas, respuesta al pulido mecánico, reacción con pintura de Ag, efecto del agua y de soluciones de limpieza y almacenamiento. Encontramos que, tomando los cuidados necesarios, las resinas epoxi Wilpox APV 3C y Araldite CY-248 + HY-956 son las más idóneas para encapsular membranas de vidrios calcogenuros en bulk, mientras que la resina epoxi Wilpox APV 3C y la resina acrílica Vaicel resultan ser las mejores candidatas para el caso de las membranas en forma de película delgada.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 25 (3)
Open AccessSobre los materiales de encapsulado para electrodos selectivos de iones
RESUMEN Los electrodos selectivos de iones (ISEs) con membranas de vidrios calcogenuros son sensores capaces de detectar iones de metales pesados en soluciones electrolíticas. Su uso in-situ y repetido plantea grandes desafíos a la selección del material para encapsular la membrana sensible. La falla en el encapsulado inutiliza al sensor, que debe ser descartado. Sin embargo, no existe hasta ahora estudios reportados sobre este componente crítico de los sensores. El material encapsulante debe aislar al contacto eléctrico de la solución circundante, tener un bajo nivel de absorción de la solución y de los iones en solución, así como mantener sus propiedades invariables por largos períodos de tiempo. Los requisitos del material dependerán también de la geometría de la membrana, ya sea en bulk o en forma de película delgada. Con el fin de facilitar nuevas investigaciones en la temática de los ISEs, estudiamos cinco materiales encapsulantes disponibles comercialmente en la región latinoamericana (Poxipol transparente, Vaicel, Wilpox APV 3C, Wilpox Doming P-5 y Araldite CY-248 + HY-956). Analizamos los requisitos de estabilidad y confiabilidad evaluando las siguientes propiedades: viscosidad, tiempo de curado, dureza, calidad superficial, formación de burbujas, respuesta al pulido mecánico, reacción con pintura de Ag, efecto del agua y de soluciones de limpieza y almacenamiento. Encontramos que, tomando los cuidados necesarios, las resinas epoxi Wilpox APV 3C y Araldite CY-248 + HY-956 son las más idóneas para encapsular membranas de vidrios calcogenuros en bulk, mientras que la resina epoxi Wilpox APV 3C y la resina acrílica Vaicel resultan ser las mejores candidatas para el caso de las membranas en forma de película delgada.
- Top Cited Papers
- 26 October 2018
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 362 (6413) , eaao0195-+
Soft magnetic materials for a sustainable and electrified world
Faster switching for soft magnets: The most familiar magnets are permanent magnets like the ones on a refrigerator door. However, for applications in transformers and motors, soft magnets that can rapidly switch their magnetization in response to a magnetic field are used. In electronics, wide bandgap semiconductors such as silicon carbide will allow power conversion electronics and motor controllers to operate more efficiently, but soft magnets must be developed that can respond at higher frequencies. Silveyra et al. review the development of current soft magnetic materials and opportunities for improving their performance in high-frequency operation. Materials being explored include soft ferrites, amorphous and nanocrystalline alloys, and powder cores or soft magnetic composites. Science , this issue p. eaao0195
- 26 October 2018
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 362 (6413) , eaao0195-+
Top Cited PapersSoft magnetic materials for a sustainable and electrified world
Faster switching for soft magnets: The most familiar magnets are permanent magnets like the ones on a refrigerator door. However, for applications in transformers and motors, soft magnets that can rapidly switch their magnetization in response to a magnetic field are used. In electronics, wide bandgap semiconductors such as silicon carbide will allow power conversion electronics and motor controllers to operate more efficiently, but soft magnets must be developed that can respond at higher frequencies. Silveyra et al. review the development of current soft magnetic materials and opportunities for improving their performance in high-frequency operation. Materials being explored include soft ferrites, amorphous and nanocrystalline alloys, and powder cores or soft magnetic composites. Science , this issue p. eaao0195
- Open Access
- 13 August 2018
- Published by Springer Nature in Journal of Materials Research
- Vol. 33 (15) , 2119
Introduction
- 13 August 2018
- Published by Springer Nature in Journal of Materials Research
- Vol. 33 (15) , 2119
Open AccessIntroduction