Donald William Howie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Donald William Howie has a total of 246 co-authors. Here are the top co-authors by number of shared publications:
- Lucian Bogdan Solomon
Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
37 shared publications - Stuart Adam Callary
Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
23 shared publications Kerry Costi
Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia; Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia, Australia
12 shared publicationsMargaret A. McGee
Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
11 shared publicationsDavid R. Haynes
University of Adelaide
9 shared publications- Gerald J. Atkins
Biomedical Orthopaedic Research Group, Discipline of Orthopaedics and Trauma, School of Medicine, College of Health, Adelaide University, Adelaide, SA, Australia
9 shared publications
Latest Publications
- 1 April 2020
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 8 (4) , e0170
Acetabular Component Migration Measured Using Radiostereometric Analysis Following Revision Total Hip Arthroplasty
» Radiostereometric analysis (RSA) studies of acetabular component migration following revision total hip arthroplasty (THA) have a large variation in their methodology and reporting of results, and, therefore, they may not be directly comparable. Standardization of RSA reporting is recommended. » In our review of RSA studies, there was a trend for cemented acetabular components to have larger amounts of early proximal migration than uncemented acetabular components. Results regarding cemented and uncemented components should be reported separately. » Cohorts that addressed larger acetabular defects were associated with a larger amount of early migration. » Reporting the migration result at 1 and 2 years postoperatively may enable earlier identification of poorly performing implants.
- 1 April 2020
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 8 (4) , e0170
Acetabular Component Migration Measured Using Radiostereometric Analysis Following Revision Total Hip Arthroplasty
» Radiostereometric analysis (RSA) studies of acetabular component migration following revision total hip arthroplasty (THA) have a large variation in their methodology and reporting of results, and, therefore, they may not be directly comparable. Standardization of RSA reporting is recommended. » In our review of RSA studies, there was a trend for cemented acetabular components to have larger amounts of early proximal migration than uncemented acetabular components. Results regarding cemented and uncemented components should be reported separately. » Cohorts that addressed larger acetabular defects were associated with a larger amount of early migration. » Reporting the migration result at 1 and 2 years postoperatively may enable earlier identification of poorly performing implants.
- 10 February 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (7) , 1497-1505
Accuracy of EBRA‐cup measurements after reconstruction of severe acetabular defects at revision THR
Radiostereometric analysis (RSA) is the most accurate method of measuring component migration using radiographs but is restricted to use in prospective studies. Ein‐Bild‐Roentgen‐analyze (EBRA)‐Cup can be used retrospectively, but its accuracy to measure component migration following revision is unknown. This study aimed to determine the accuracy of EBRA‐Cup measurements of uncemented acetabular component migration after revision total hip replacement (THR). The secondary aim was to compare the number of cases identified using EBRA‐Cup and RSA as having proximally migrated above and below 1 mm at 2 years postoperatively. EBRA‐Cup measurements were performed on plain antero‐posterior pelvic radiographs taken at the same time as RSA radiographs in a prospective cohort of 53 hips undergoing acetabular revision. At 2 years, the mean difference between the RSA and EBRA‐Cup measurements for 17 components used to treat pelvic discontinuity was 0.90 mm, significantly greater than the mean difference of 0.28 mm for 36 components without discontinuity (P = .0001). The mean difference between the RSA and EBRA‐Cup measurements at 2 years for hips that were reconstructed with an acetabular component alone, 0.28 mm, was significantly lower than hips that were reconstructed with an acetabular component in combination with an augment and/or cage, 0.74 mm (P = .0005). In conclusion, EBRA‐Cup can accurately measure migration of uncemented acetabular components used at revision THR. The presence of pelvic discontinuity, and addition of augments and cages, significantly influenced the accuracy of EBRA‐Cup measurements. EBRA‐Cup and RSA had good agreement on classification of components that migrated proximally above or below 1 mm at 2 years, with 100% sensitivity, and 87% specificity.
- 10 February 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (7) , 1497-1505
Accuracy of EBRA‐cup measurements after reconstruction of severe acetabular defects at revision THR
Radiostereometric analysis (RSA) is the most accurate method of measuring component migration using radiographs but is restricted to use in prospective studies. Ein‐Bild‐Roentgen‐analyze (EBRA)‐Cup can be used retrospectively, but its accuracy to measure component migration following revision is unknown. This study aimed to determine the accuracy of EBRA‐Cup measurements of uncemented acetabular component migration after revision total hip replacement (THR). The secondary aim was to compare the number of cases identified using EBRA‐Cup and RSA as having proximally migrated above and below 1 mm at 2 years postoperatively. EBRA‐Cup measurements were performed on plain antero‐posterior pelvic radiographs taken at the same time as RSA radiographs in a prospective cohort of 53 hips undergoing acetabular revision. At 2 years, the mean difference between the RSA and EBRA‐Cup measurements for 17 components used to treat pelvic discontinuity was 0.90 mm, significantly greater than the mean difference of 0.28 mm for 36 components without discontinuity (P = .0001). The mean difference between the RSA and EBRA‐Cup measurements at 2 years for hips that were reconstructed with an acetabular component alone, 0.28 mm, was significantly lower than hips that were reconstructed with an acetabular component in combination with an augment and/or cage, 0.74 mm (P = .0005). In conclusion, EBRA‐Cup can accurately measure migration of uncemented acetabular components used at revision THR. The presence of pelvic discontinuity, and addition of augments and cages, significantly influenced the accuracy of EBRA‐Cup measurements. EBRA‐Cup and RSA had good agreement on classification of components that migrated proximally above or below 1 mm at 2 years, with 100% sensitivity, and 87% specificity.
- 1 July 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (7) , 1430-1434
Vancouver B2 Peri-Prosthetic Fractures in Cemented Femoral Implants can be Treated With Open Reduction and Internal Fixation Alone Without Revision
- 1 July 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (7) , 1430-1434
Vancouver B2 Peri-Prosthetic Fractures in Cemented Femoral Implants can be Treated With Open Reduction and Internal Fixation Alone Without Revision
- 1 January 2019
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 9 (3) , e0347
Surgical Technique to Manage Periprosthetic Fractures of the Knee in Patients with Infected Leg Ulcers
Cases: We describe 2 cases of nonagenarians with periprosthetic knee fractures that were not amenable to either standard internal fixation nor prosthesis revision because of infected leg ulcers in the same limb. The fractures were internally fixed by percutaneous insertion of medial and lateral plates that spanned the knee. Both patients returned to their baseline level of activity without developing surgical site infections. Conclusions: Percutaneous bridging plates that span the knee are a useful option for treating these difficult cases.
- 1 January 2019
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 9 (3) , e0347
Surgical Technique to Manage Periprosthetic Fractures of the Knee in Patients with Infected Leg Ulcers
Cases: We describe 2 cases of nonagenarians with periprosthetic knee fractures that were not amenable to either standard internal fixation nor prosthesis revision because of infected leg ulcers in the same limb. The fractures were internally fixed by percutaneous insertion of medial and lateral plates that spanned the knee. Both patients returned to their baseline level of activity without developing surgical site infections. Conclusions: Percutaneous bridging plates that span the knee are a useful option for treating these difficult cases.
- 21 November 2018
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 100 (22) , 1926-1933
The Stability of the Porous Tantalum Components Used in Revision THA to Treat Severe Acetabular Defects
Background: The acetabular components used in revision total hip arthroplasty (THA) to treat severe acetabular bone defects have high rates of re-revision at mid to long-term follow-up. Early translation of acetabular components used in revision THA is a good predictor of later loosening, and radiostereometric analysis (RSA) is the most sensitive method to measure migration. The objectives of the present study were to use RSA to compare the migration of the porous tantalum acetabular components used to treat severe bone defects with the previously established acceptable proximal translation threshold of ≤1 mm within 2 years, and to determine the effect on migration of the addition of inferior screws through the component into the ischium or pubis. Methods: RSA was utilized to measure the migration of 55 porous tantalum components used to treat severe acetabular defects (28 Paprosky IIIA, 27 Paprosky IIIB; 21 hips with pelvic discontinuity) at a mean follow-up of 4 years (range, 2 to 12 years). Results: Forty-eight of the 55 components migrated less than the threshold that predicts later loosening (>1 mm) and 50 had not been re-revised at the time of the latest follow-up. Seven components, none of which had inferior screw fixation, exceeded the translation threshold. Of these, 6 were implanted to treat pelvic discontinuity. Of those 6 components, 5 were re-revised for loosening related to patient symptoms. At 2 years, the absolute median proximal translation of components with inferior screw fixation was |0.3| mm (range, |0.1| to |0.9| mm), compared with |0.4| mm (range, |0.03| to |16.4| mm) for those without inferior screws (p = 0.04). Conclusions: As measured with use of RSA, the majority of porous tantalum acetabular components used in a revision THA to treat severe acetabular defects had acceptable early migration. This predicts good long-term survivorship of these components. The use of inferior screws further improved acetabular component fixation. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 21 November 2018
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 100 (22) , 1926-1933
The Stability of the Porous Tantalum Components Used in Revision THA to Treat Severe Acetabular Defects
Background: The acetabular components used in revision total hip arthroplasty (THA) to treat severe acetabular bone defects have high rates of re-revision at mid to long-term follow-up. Early translation of acetabular components used in revision THA is a good predictor of later loosening, and radiostereometric analysis (RSA) is the most sensitive method to measure migration. The objectives of the present study were to use RSA to compare the migration of the porous tantalum acetabular components used to treat severe bone defects with the previously established acceptable proximal translation threshold of ≤1 mm within 2 years, and to determine the effect on migration of the addition of inferior screws through the component into the ischium or pubis. Methods: RSA was utilized to measure the migration of 55 porous tantalum components used to treat severe acetabular defects (28 Paprosky IIIA, 27 Paprosky IIIB; 21 hips with pelvic discontinuity) at a mean follow-up of 4 years (range, 2 to 12 years). Results: Forty-eight of the 55 components migrated less than the threshold that predicts later loosening (>1 mm) and 50 had not been re-revised at the time of the latest follow-up. Seven components, none of which had inferior screw fixation, exceeded the translation threshold. Of these, 6 were implanted to treat pelvic discontinuity. Of those 6 components, 5 were re-revised for loosening related to patient symptoms. At 2 years, the absolute median proximal translation of components with inferior screw fixation was |0.3| mm (range, |0.1| to |0.9| mm), compared with |0.4| mm (range, |0.03| to |16.4| mm) for those without inferior screws (p = 0.04). Conclusions: As measured with use of RSA, the majority of porous tantalum acetabular components used in a revision THA to treat severe acetabular defects had acceptable early migration. This predicts good long-term survivorship of these components. The use of inferior screws further improved acetabular component fixation. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 12 November 2018
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 477 (5) , 1126-1134
Structured-mentorship Program for Periacetabular Osteotomy Resulted in Few Complications for a Low-volume Pelvic Surgeon
Background: The Bernese periacetabular osteotomy (PAO) is a complex surgical procedure with a substantial learning curve. Although larger hospital and surgeon procedure volumes have recently been associated with a lower risk of complications, in geographically isolated regions, some complex operations such as PAO will inevitably be performed in low volume. A continuous structured program of distant mentoring may offer benefits when low numbers of PAOs are undertaken, but this has not been tested. We sought to examine a structured, distant-mentorship program of a low-volume surgeon in a geographically remote setting. Questions/purposes: The purposes of this study were (1) to identify the clinical results of PAO performed in a remote-mentorship program, as determined by patient-reported outcome measures and complications of the surgery; (2) to determine radiographic results, specifically postoperative angular corrections, hip congruity, and progression of osteoarthritis; and (3) to determine worst-case analysis of PAO survivorship, defined as nonconversion to THA, in a regionally isolated cohort of patients with a high rate of followup. Methods: Between August 1992 and August 2016, 85 PAOs were undertaken in 72 patients under a structured, distant-mentorship program. The patients were followed for a median of 5 years (range, 2-25 years). There were 18 males (21 hips) and 54 females (64 hips). The median age of the patients at the time of surgery was 26 years (range, 14-45 years). One patient was lost to followup (two PAOs) and one patient died as a result of an unrelated event. Patient-reported outcome measures and complications were collected through completion of patient and doctor questionnaires and clinical examination. Radiographic assessment of angular correction, joint congruity, and osteoarthritis was undertaken using standard radiology software. PAO survivorship was defined as nonconversion to THA and is presented using worst-case analysis. The loss-to-followup quotient—number of patients lost to followup divided by the number of a patients converted to THA—was calculated to determine quality of followup and reliability of survivorship data. Results: The median preoperative Harris hip scores of 58 (range, 20-96) improved postoperatively to 78 (range, 33-100), 86 (range, 44-100), 87 (range, 55-97), and 80 (range, 41-97) at 1, 5, 10, and 14 years, respectively. Sink Grade III complications at 12 months included four relating to the PAO and one relating to the concomitant femoral procedure. The median lateral center-edge angle correction achieved was 22° (range, 3°-50°) and the median correction of acetabular index was 19° (range, 3°-37°). Osteoarthritis progressed from a preoperative mean Tönnis grade of 0.6 (median, 1; range, 0-2) to a postoperative mean of 0.9 (median, 1; range, 0-3). Six hips underwent conversion to THA: five for progression of osteoarthritis and one for impingement. At 12-year followup, survivorship of PAO was 94% (95% confidence interval [CI], 85%-98%) and survivorship with worst-case analysis was 90% (95% CI, 79%-96%). The loss-to-followup quotient for this study was low, calculated to be 0.3. Conclusions: When PAO is performed using a structured process of mentoring under the guidance of an expert, one low-volume surgeon in a geographically isolated region achieved good patient-reported outcomes, a low incidence of complications at 12 months, satisfactory radiographic outcomes, and high survivorship. A structured distant-mentorship program may be a suitable method for initially learning and continuing to perform low-volume complex surgery in a geographically isolated region. Level of Evidence: Level IV, therapeutic study.
- 12 November 2018
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 477 (5) , 1126-1134
Structured-mentorship Program for Periacetabular Osteotomy Resulted in Few Complications for a Low-volume Pelvic Surgeon
Background: The Bernese periacetabular osteotomy (PAO) is a complex surgical procedure with a substantial learning curve. Although larger hospital and surgeon procedure volumes have recently been associated with a lower risk of complications, in geographically isolated regions, some complex operations such as PAO will inevitably be performed in low volume. A continuous structured program of distant mentoring may offer benefits when low numbers of PAOs are undertaken, but this has not been tested. We sought to examine a structured, distant-mentorship program of a low-volume surgeon in a geographically remote setting. Questions/purposes: The purposes of this study were (1) to identify the clinical results of PAO performed in a remote-mentorship program, as determined by patient-reported outcome measures and complications of the surgery; (2) to determine radiographic results, specifically postoperative angular corrections, hip congruity, and progression of osteoarthritis; and (3) to determine worst-case analysis of PAO survivorship, defined as nonconversion to THA, in a regionally isolated cohort of patients with a high rate of followup. Methods: Between August 1992 and August 2016, 85 PAOs were undertaken in 72 patients under a structured, distant-mentorship program. The patients were followed for a median of 5 years (range, 2-25 years). There were 18 males (21 hips) and 54 females (64 hips). The median age of the patients at the time of surgery was 26 years (range, 14-45 years). One patient was lost to followup (two PAOs) and one patient died as a result of an unrelated event. Patient-reported outcome measures and complications were collected through completion of patient and doctor questionnaires and clinical examination. Radiographic assessment of angular correction, joint congruity, and osteoarthritis was undertaken using standard radiology software. PAO survivorship was defined as nonconversion to THA and is presented using worst-case analysis. The loss-to-followup quotient—number of patients lost to followup divided by the number of a patients converted to THA—was calculated to determine quality of followup and reliability of survivorship data. Results: The median preoperative Harris hip scores of 58 (range, 20-96) improved postoperatively to 78 (range, 33-100), 86 (range, 44-100), 87 (range, 55-97), and 80 (range, 41-97) at 1, 5, 10, and 14 years, respectively. Sink Grade III complications at 12 months included four relating to the PAO and one relating to the concomitant femoral procedure. The median lateral center-edge angle correction achieved was 22° (range, 3°-50°) and the median correction of acetabular index was 19° (range, 3°-37°). Osteoarthritis progressed from a preoperative mean Tönnis grade of 0.6 (median, 1; range, 0-2) to a postoperative mean of 0.9 (median, 1; range, 0-3). Six hips underwent conversion to THA: five for progression of osteoarthritis and one for impingement. At 12-year followup, survivorship of PAO was 94% (95% confidence interval [CI], 85%-98%) and survivorship with worst-case analysis was 90% (95% CI, 79%-96%). The loss-to-followup quotient for this study was low, calculated to be 0.3. Conclusions: When PAO is performed using a structured process of mentoring under the guidance of an expert, one low-volume surgeon in a geographically isolated region achieved good patient-reported outcomes, a low incidence of complications at 12 months, satisfactory radiographic outcomes, and high survivorship. A structured distant-mentorship program may be a suitable method for initially learning and continuing to perform low-volume complex surgery in a geographically isolated region. Level of Evidence: Level IV, therapeutic study.
- 1 November 2018
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 100-B (11) , 1455-1462
Risk analysis of patients with an osteolytic acetabular defect after total hip arthroplasty using subject-specific finite-element modelling
Aims: Osteolysis, secondary to local and systemic physiological effects, is a major challenge in total hip arthroplasty (THA). While osteolytic defects are commonly observed in long-term follow-up, how such lesions alter the distribution of stress is unclear. The aim of this study was to quantitatively describe the biomechanical implication of such lesions by performing subject-specific finite-element (FE) analysis on patients with osteolysis after THA.Patients and Methods: A total of 22 hemipelvis FE models were constructed in order to assess the transfer of load in 11 patients with osteolysis around the acetabular component of a THA during slow walking and a fall onto the side. There were nine men and two women. Their mean age was 69 years (55 to 81) at final follow-up. Changes in peak stress values and loads to fracture in the presence of the osteolytic defects were measured.Results: The von Mises stresses were increased in models of those with and those without defects for both loading scenarios. Although some regions showed increases in stress values of up to 100%, there was only a moderate 11.2% increase in von Mises stress in the series as a whole. The site of fracture changed in some models with lowering of the load to fracture by 500 N. The most common site of fracture was the pubic ramus. This was more frequent in models with larger defects.Conclusion: We conclude that cancellous defects cause increases in stress within cortical structures. However, these are likely to lead to a modest decrease in the load to fracture if the defect is large (> 20cm3) or if the patient is small with thin cortical structures and low bone mineral density. Cite this article: Bone Joint J 2018;100-B:1455–62.
- 1 November 2018
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 100-B (11) , 1455-1462
Risk analysis of patients with an osteolytic acetabular defect after total hip arthroplasty using subject-specific finite-element modelling
Aims: Osteolysis, secondary to local and systemic physiological effects, is a major challenge in total hip arthroplasty (THA). While osteolytic defects are commonly observed in long-term follow-up, how such lesions alter the distribution of stress is unclear. The aim of this study was to quantitatively describe the biomechanical implication of such lesions by performing subject-specific finite-element (FE) analysis on patients with osteolysis after THA.Patients and Methods: A total of 22 hemipelvis FE models were constructed in order to assess the transfer of load in 11 patients with osteolysis around the acetabular component of a THA during slow walking and a fall onto the side. There were nine men and two women. Their mean age was 69 years (55 to 81) at final follow-up. Changes in peak stress values and loads to fracture in the presence of the osteolytic defects were measured.Results: The von Mises stresses were increased in models of those with and those without defects for both loading scenarios. Although some regions showed increases in stress values of up to 100%, there was only a moderate 11.2% increase in von Mises stress in the series as a whole. The site of fracture changed in some models with lowering of the load to fracture by 500 N. The most common site of fracture was the pubic ramus. This was more frequent in models with larger defects.Conclusion: We conclude that cancellous defects cause increases in stress within cortical structures. However, these are likely to lead to a modest decrease in the load to fracture if the defect is large (> 20cm3) or if the patient is small with thin cortical structures and low bone mineral density. Cite this article: Bone Joint J 2018;100-B:1455–62.
- 1 August 2017
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 127 (2) , 317-325
Predicting Perioperative Transfusion in Elective Hip and Knee Arthroplasty
Background: Preoperative anemia is a significant predictor of perioperative erythrocyte transfusion in elective arthroplasty patients. However, interactions with other patient and procedure characteristics predicting transfusion requirements have not been well studied. Methods: Patients undergoing elective primary total hip arthroplasty or total knee arthroplasty at a tertiary hospital in Adelaide, South Australia, Australia, from January 2010 to June 2014 were used to identify preoperative predictors of perioperative transfusion. A logistic regression model was developed and externally validated with an independent data set from three other hospitals in Adelaide. Results: Altogether, 737 adult patients in the derivation group and 653 patients in the validation group were included. Binary logistic regression modeling identified preoperative hemoglobin (odds ratio, 0.51; 95% CI, 0.43 to 0.59; P < 0.001 for each 1 g/dl increase), total hip arthroplasty (odds ratio, 3.56; 95% CI, 2.39 to 5.30; P < 0.001), and females 65 yr of age and older (odds ratio, 3.37; 95% CI, 1.88 to 6.04; P = 0.01) as predictors of transfusion in the derivation cohort. Conclusions: Using a combination of patient-specific preoperative variables, this validated model can predict transfusion in patients undergoing elective hip and knee arthroplasty. The model may also help to identify patients whose need for transfusion may be decreased through preoperative hemoglobin optimization.
- 1 August 2017
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 127 (2) , 317-325
Predicting Perioperative Transfusion in Elective Hip and Knee Arthroplasty
Background: Preoperative anemia is a significant predictor of perioperative erythrocyte transfusion in elective arthroplasty patients. However, interactions with other patient and procedure characteristics predicting transfusion requirements have not been well studied. Methods: Patients undergoing elective primary total hip arthroplasty or total knee arthroplasty at a tertiary hospital in Adelaide, South Australia, Australia, from January 2010 to June 2014 were used to identify preoperative predictors of perioperative transfusion. A logistic regression model was developed and externally validated with an independent data set from three other hospitals in Adelaide. Results: Altogether, 737 adult patients in the derivation group and 653 patients in the validation group were included. Binary logistic regression modeling identified preoperative hemoglobin (odds ratio, 0.51; 95% CI, 0.43 to 0.59; P < 0.001 for each 1 g/dl increase), total hip arthroplasty (odds ratio, 3.56; 95% CI, 2.39 to 5.30; P < 0.001), and females 65 yr of age and older (odds ratio, 3.37; 95% CI, 1.88 to 6.04; P = 0.01) as predictors of transfusion in the derivation cohort. Conclusions: Using a combination of patient-specific preoperative variables, this validated model can predict transfusion in patients undergoing elective hip and knee arthroplasty. The model may also help to identify patients whose need for transfusion may be decreased through preoperative hemoglobin optimization.
- 1 April 2017
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 99-B (4) , 458-464
The diagnostic performance of radiographic criteria to detect aseptic acetabular component loosening after revision total hip arthroplasty
Aims This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria. Patients and Methods Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed. Results Using EBRA, both proximal translation and sagittal rotation were excellent diagnostic tests for detecting aseptic loosening. The area under the receiver operating characteristic (ROC) curves was 0.94 and 0.93, respectively. The thresholds of 2.5 mm proximal translation or 2° sagittal rotation (EBRA) in combination with radiolucency criteria had a sensitivity of 93% and specificity of 88% to detect aseptic loosening. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of radiolucency criteria were 41%, 100%, 100% and 68% respectively. Manual measurements of both proximal translation and sagittal rotation were very good diagnostic tests. The area under the ROC curve was 0.86 and 0.92 respectively. However, manual measurements had a decreased specificity compared with EBRA. Radiolucency criteria had a poor sensitivity and NPV of 41% and 68% respectively. Conclusion This study shows that EBRA and manual migration measurements can be used as accurate diagnostic tools to detect aseptic loosening of cementless acetabular components used at revision THA. Radiolucency criteria should not be used in isolation to exclude loosening of cementless acetabular components used at revision THA given their poor sensitivity and NPV. Cite this article: Bone Joint J 2017;99-B:458–64.
- 1 April 2017
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 99-B (4) , 458-464
The diagnostic performance of radiographic criteria to detect aseptic acetabular component loosening after revision total hip arthroplasty
Aims This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria. Patients and Methods Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed. Results Using EBRA, both proximal translation and sagittal rotation were excellent diagnostic tests for detecting aseptic loosening. The area under the receiver operating characteristic (ROC) curves was 0.94 and 0.93, respectively. The thresholds of 2.5 mm proximal translation or 2° sagittal rotation (EBRA) in combination with radiolucency criteria had a sensitivity of 93% and specificity of 88% to detect aseptic loosening. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of radiolucency criteria were 41%, 100%, 100% and 68% respectively. Manual measurements of both proximal translation and sagittal rotation were very good diagnostic tests. The area under the ROC curve was 0.86 and 0.92 respectively. However, manual measurements had a decreased specificity compared with EBRA. Radiolucency criteria had a poor sensitivity and NPV of 41% and 68% respectively. Conclusion This study shows that EBRA and manual migration measurements can be used as accurate diagnostic tools to detect aseptic loosening of cementless acetabular components used at revision THA. Radiolucency criteria should not be used in isolation to exclude loosening of cementless acetabular components used at revision THA given their poor sensitivity and NPV. Cite this article: Bone Joint J 2017;99-B:458–64.
- 1 April 2017
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 99-B (4) , 465-474
Proximal translation of > 1 mm within the first two years of revision total hip arthroplasty correctly predicts whether or not an acetabular component is loose in 80% of cases
Aims The purpose of this study was to determine the sensitivity, specificity and predictive values of previously reported thresholds of proximal translation and sagittal rotation of cementless acetabular components used for revision total hip arthroplasty (THA) at various times during early follow-up. Patients and Methods Migration of cementless acetabular components was measured retrospectively in 84 patients (94 components) using Ein-Bild-Rontgen-Analyse (EBRA-Cup) in two groups of patients. In Group A, components were recorded as not being loose intra-operatively at re-revision THA (52 components/48 patients) and Group B components were recorded to be loose at re-revision (42 components/36 patients). Results The mean proximal translation and sagittal rotation were significantly higher in Group B than in Group A from three months onwards (p < 0.02). Proximal translation > 1.0 mm within 24 months had a positive predictive value (PPV) of 90% and a specificity of 94%, but a sensitivity of 64%. Proximal translation > 1.0 mm within the first 24 months correctly identified 76 of 94 (81%) of components to be either loose or not loose. However, ten components in Group B (24%) did not migrate proximally above 1.0 mm within the first 60 months. Conclusion The high PPV of EBRA-Cup measurements of proximal translation (90%) shows that this can be used in early follow-up to identify patients at risk of aseptic loosening. The absence of proximal translation within the first 60 months indicates a component is not likely to be loose at re-revision THA although it does not exclude late aseptic loosening as a cause of failure. Cite this article: Bone Joint J 2017;99-B:465–74.
- 1 April 2017
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 99-B (4) , 465-474
Proximal translation of > 1 mm within the first two years of revision total hip arthroplasty correctly predicts whether or not an acetabular component is loose in 80% of cases
Aims The purpose of this study was to determine the sensitivity, specificity and predictive values of previously reported thresholds of proximal translation and sagittal rotation of cementless acetabular components used for revision total hip arthroplasty (THA) at various times during early follow-up. Patients and Methods Migration of cementless acetabular components was measured retrospectively in 84 patients (94 components) using Ein-Bild-Rontgen-Analyse (EBRA-Cup) in two groups of patients. In Group A, components were recorded as not being loose intra-operatively at re-revision THA (52 components/48 patients) and Group B components were recorded to be loose at re-revision (42 components/36 patients). Results The mean proximal translation and sagittal rotation were significantly higher in Group B than in Group A from three months onwards (p < 0.02). Proximal translation > 1.0 mm within 24 months had a positive predictive value (PPV) of 90% and a specificity of 94%, but a sensitivity of 64%. Proximal translation > 1.0 mm within the first 24 months correctly identified 76 of 94 (81%) of components to be either loose or not loose. However, ten components in Group B (24%) did not migrate proximally above 1.0 mm within the first 60 months. Conclusion The high PPV of EBRA-Cup measurements of proximal translation (90%) shows that this can be used in early follow-up to identify patients at risk of aseptic loosening. The absence of proximal translation within the first 60 months indicates a component is not likely to be loose at re-revision THA although it does not exclude late aseptic loosening as a cause of failure. Cite this article: Bone Joint J 2017;99-B:465–74.