Donghoon Son
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Donghoon Son has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Metin Sitti
Physical Intelligence Department, Max Planck Institute for Intelligent Systems, Stuttgart 70569, Germany
6 shared publications Jongwon Kim
4 shared publicationsDoyoung Chang
3 shared publicationsDirk‐Michael Drotlef
Physical Intelligence Department Max Planck Institute for Intelligent Systems Stuttgart 70569 Germany
2 shared publications- Doyoung Chang
School of Mechanical and Aerospace Engineering, Seoul National University, Seoul 151-744, South Korea
2 shared publications Hanbi Park
Department of Mechanical Systems Engineering Sookmyung Women's University Seoul Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 7 September 2026
- Published by Wiley in Advanced Intelligent Systems
A Hybrid Magnetic Actuation System for Single‐Input Multistates Stabilization: Application to pH‐Responsive Drug Delivery
Targeted drug delivery requires precise carrier navigation and controlled payload release. We present an integrated robotic platform that combines a hybrid magnetic array with a pH‐responsive soft hydrogel. The array achieves single‐input, multistate stabilization: one current input actively regulates the z ‐axis equilibrium, while the x , y , ϕ , and θ states passively converge through an optimized magnetic potential‐energy landscape. Translating the array along x , y , and z , changing its azimuth provides intuitive 4‐DOF manipulation; an additional current‐redistribution parameter shifts the equilibrium to enable limited θ manipulation, yielding semi‐5‐DOF performance. The system achieves submillimeter positioning in low‐viscosity water. The hydrogel provides passive, pH‐triggered detachment under acidic conditions without additional external actuation. In a simplified pH 2 aqueous environment representing only the acidic‐pH aspect of gastric conditions, the platform completes magnetic transport, hydrogel detachment, and capsule retrieval. These results demonstrate the operational feasibility of integrating precise magnetic navigation with environment‐responsive release and provide a foundation for future targeted‐delivery robotic systems.
- 7 September 2026
- Published by Wiley in Advanced Intelligent Systems
Open AccessA Hybrid Magnetic Actuation System for Single‐Input Multistates Stabilization: Application to pH‐Responsive Drug Delivery
Targeted drug delivery requires precise carrier navigation and controlled payload release. We present an integrated robotic platform that combines a hybrid magnetic array with a pH‐responsive soft hydrogel. The array achieves single‐input, multistate stabilization: one current input actively regulates the z ‐axis equilibrium, while the x , y , ϕ , and θ states passively converge through an optimized magnetic potential‐energy landscape. Translating the array along x , y , and z , changing its azimuth provides intuitive 4‐DOF manipulation; an additional current‐redistribution parameter shifts the equilibrium to enable limited θ manipulation, yielding semi‐5‐DOF performance. The system achieves submillimeter positioning in low‐viscosity water. The hydrogel provides passive, pH‐triggered detachment under acidic conditions without additional external actuation. In a simplified pH 2 aqueous environment representing only the acidic‐pH aspect of gastric conditions, the platform completes magnetic transport, hydrogel detachment, and capsule retrieval. These results demonstrate the operational feasibility of integrating precise magnetic navigation with environment‐responsive release and provide a foundation for future targeted‐delivery robotic systems.
- Open Access
- 3 April 2026
- Published by Elsevier in Materials Today Bio
- Vol. 38, 103093
Ecoflex-hydrogel bilayer soft robot for pH-controlled drug protection and delivery
- 3 April 2026
- Published by Elsevier in Materials Today Bio
- Vol. 38, 103093
Open AccessEcoflex-hydrogel bilayer soft robot for pH-controlled drug protection and delivery
- 6 April 2025
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 77
Layer-jamming soft gripper for improved stiffness control and underwater adhesion
- 6 April 2025
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 77
Layer-jamming soft gripper for improved stiffness control and underwater adhesion
- Open Access
- 14 January 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (2) , eabk0685
Order and information in the patterns of spinning magnetic micro-disks at the air-water interface
A local measure based on the Shannon entropy establishes connections among information, structures, and interactions.
- 14 January 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (2) , eabk0685
Open AccessOrder and information in the patterns of spinning magnetic micro-disks at the air-water interface
A local measure based on the Shannon entropy establishes connections among information, structures, and interactions.
- Open Access
- 22 October 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (43)
Permanent magnet array–driven navigation of wireless millirobots inside soft tissues
A wireless magnetic millirobot navigates inside an ex vivo porcine brain propelled by a permanent magnetic array–based force trap.
- 22 October 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (43)
Open AccessPermanent magnet array–driven navigation of wireless millirobots inside soft tissues
A wireless magnetic millirobot navigates inside an ex vivo porcine brain propelled by a permanent magnetic array–based force trap.
- Open Access
- 3 July 2021
- Published by Wiley in Advanced Science
- Vol. 8 (17) , 2100641
Adaptive Self‐Sealing Suction‐Based Soft Robotic Gripper
While suction cups prevail as common gripping tools for a wide range of real‐world parts and surfaces, they often fail to seal the contact interface when engaging with irregular shapes and textured surfaces. In this work, the authors propose a suction‐based soft robotic gripper where suction is created inside a self‐sealing, highly conformable and thin flat elastic membrane contacting a given part surface. Such soft gripper can self‐adapt the size of its effective suction area with respect to the applied load. The elastomeric membrane covering edge of the soft gripper can develop an air‐tight self‐sealing with parts even smaller than the gripper diameter. Such gripper shows 4 times higher adhesion than the one without the membrane on various textured surfaces. The two major advantages, underactuated self‐adaptability and enhanced suction performance, allow the membrane‐based suction mechanism to grip various three‐dimensional (3D) geometries and delicate parts, such as egg, lime, apple, and even hydrogels without noticeable damage, which can have not been gripped with the previous adhesive microstructures‐based and active suction‐based soft grippers. The structural and material simplicity of the proposed soft gripper design can have a broad use in diverse fields, such as digital manufacturing, robotic manipulation, transfer printing, and medical gripping.
- 3 July 2021
- Published by Wiley in Advanced Science
- Vol. 8 (17) , 2100641
Open AccessAdaptive Self‐Sealing Suction‐Based Soft Robotic Gripper
While suction cups prevail as common gripping tools for a wide range of real‐world parts and surfaces, they often fail to seal the contact interface when engaging with irregular shapes and textured surfaces. In this work, the authors propose a suction‐based soft robotic gripper where suction is created inside a self‐sealing, highly conformable and thin flat elastic membrane contacting a given part surface. Such soft gripper can self‐adapt the size of its effective suction area with respect to the applied load. The elastomeric membrane covering edge of the soft gripper can develop an air‐tight self‐sealing with parts even smaller than the gripper diameter. Such gripper shows 4 times higher adhesion than the one without the membrane on various textured surfaces. The two major advantages, underactuated self‐adaptability and enhanced suction performance, allow the membrane‐based suction mechanism to grip various three‐dimensional (3D) geometries and delicate parts, such as egg, lime, apple, and even hydrogels without noticeable damage, which can have not been gripped with the previous adhesive microstructures‐based and active suction‐based soft grippers. The structural and material simplicity of the proposed soft gripper design can have a broad use in diverse fields, such as digital manufacturing, robotic manipulation, transfer printing, and medical gripping.
- Open Access
- 2 April 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (19) , e2000497
Liquid‐Superrepellent Bioinspired Fibrillar Adhesives
Bioinspired elastomeric fibrillar surfaces have significant potential as reversible dry adhesives, but their adhesion performance is sensitive to the presence of liquids at the contact interface. Like their models in nature, many artificial mimics can effectively repel water, but fail when low‐surface‐tension liquids are introduced at the contact interface. A bioinspired fibrillar adhesive surface that is liquid‐superrepellent even toward ultralow‐surface‐tension liquids while retaining its adhesive properties is proposed herein. This surface combines the effective adhesion principle of mushroom‐shaped fibrillar arrays with liquid repellency based on double re‐entrant fibril tip geometry. The adhesion performance of the proposed microfibril structures is retained even when low‐surface‐tension liquids are added to the contact interface. The extreme liquid repellency enables real‐world applications of fibrillar adhesives for surfaces covered with water, oil, and other liquids. Moreover, fully elastomeric liquid‐superrepellent surfaces are mechanically not brittle, highly robust against physical contact, and highly deformable and stretchable, which can increase the real‐world uses of such antiwetting surfaces.
- 2 April 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (19) , e2000497
Open AccessLiquid‐Superrepellent Bioinspired Fibrillar Adhesives
Bioinspired elastomeric fibrillar surfaces have significant potential as reversible dry adhesives, but their adhesion performance is sensitive to the presence of liquids at the contact interface. Like their models in nature, many artificial mimics can effectively repel water, but fail when low‐surface‐tension liquids are introduced at the contact interface. A bioinspired fibrillar adhesive surface that is liquid‐superrepellent even toward ultralow‐surface‐tension liquids while retaining its adhesive properties is proposed herein. This surface combines the effective adhesion principle of mushroom‐shaped fibrillar arrays with liquid repellency based on double re‐entrant fibril tip geometry. The adhesion performance of the proposed microfibril structures is retained even when low‐surface‐tension liquids are added to the contact interface. The extreme liquid repellency enables real‐world applications of fibrillar adhesives for surfaces covered with water, oil, and other liquids. Moreover, fully elastomeric liquid‐superrepellent surfaces are mechanically not brittle, highly robust against physical contact, and highly deformable and stretchable, which can increase the real‐world uses of such antiwetting surfaces.
- Top Cited Papers
- 1 February 2020
- Published by SAGE Publications in Soft Robotics
- Vol. 7 (1) , 10-21
Magnetically Actuated Soft Capsule Endoscope for Fine-Needle Biopsy
Wireless capsule endoscopes have revolutionized diagnostic procedures in the gastrointestinal (GI) tract by minimizing discomfort and trauma. Biopsy procedures, which are often necessary for a confirmed diagnosis of an illness, have been incorporated recently into robotic capsule endoscopes to improve their diagnostic functionality beyond only imaging. However, capsule robots to date have only been able to acquire biopsy samples of superficial tissues of the GI tract, which could generate false-negative diagnostic results if the diseased tissue is under the surface of the GI tract. To improve their diagnostic accuracy for submucosal tumors/diseases, we propose a magnetically actuated soft robotic capsule robot, which takes biopsy samples in a deep tissue of a stomach using the fine-needle biopsy technique. We present the design, control, and human–machine interfacing methods for the fine-needle biopsy capsule robot. Ex vivo experiments in a porcine stomach show 85% yield for the biopsy of phantom tumors located underneath the first layers of the stomach wall.
- 1 February 2020
- Published by SAGE Publications in Soft Robotics
- Vol. 7 (1) , 10-21
Top Cited PapersMagnetically Actuated Soft Capsule Endoscope for Fine-Needle Biopsy
Wireless capsule endoscopes have revolutionized diagnostic procedures in the gastrointestinal (GI) tract by minimizing discomfort and trauma. Biopsy procedures, which are often necessary for a confirmed diagnosis of an illness, have been incorporated recently into robotic capsule endoscopes to improve their diagnostic functionality beyond only imaging. However, capsule robots to date have only been able to acquire biopsy samples of superficial tissues of the GI tract, which could generate false-negative diagnostic results if the diseased tissue is under the surface of the GI tract. To improve their diagnostic accuracy for submucosal tumors/diseases, we propose a magnetically actuated soft robotic capsule robot, which takes biopsy samples in a deep tissue of a stomach using the fine-needle biopsy technique. We present the design, control, and human–machine interfacing methods for the fine-needle biopsy capsule robot. Ex vivo experiments in a porcine stomach show 85% yield for the biopsy of phantom tumors located underneath the first layers of the stomach wall.
- 28 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (2) , 343-352
A Simultaneous Calibration Method for Magnetic Robot Localization and Actuation Systems
This paper proposes a method of simultaneously calibrating magnetic localization and actuation systems for magnetically actuated robots. In this method, uncalibrated magnetic localization and actuation systems are calibrated simultaneously with minimal human intervention, which enables self-calibration, flexible reconfiguration, and long-term correctness of the system parameters. This method employs a bundle adjustment framework using a quadratic measurement model for sensors and the magnetic dipole model for actuators. The proposed method has been verified in comparison with finite element simulations and existing calibration methods for magnetic actuators and sensor arrays. In the experiments, the determinant of coefficient (R 2 value) was 99.84% for the sensor system and 99.45% for the actuator system after the calibration, comparable with individual state-of-art calibration methods of calibrating magnetic actuators and sensor arrays. This method has potential to improve the reconfigurability and long-term accuracy of magnetic robot localization and actuation systems, such as magnetically actuated capsule endoscopes.
- 28 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (2) , 343-352
A Simultaneous Calibration Method for Magnetic Robot Localization and Actuation Systems
This paper proposes a method of simultaneously calibrating magnetic localization and actuation systems for magnetically actuated robots. In this method, uncalibrated magnetic localization and actuation systems are calibrated simultaneously with minimal human intervention, which enables self-calibration, flexible reconfiguration, and long-term correctness of the system parameters. This method employs a bundle adjustment framework using a quadratic measurement model for sensors and the magnetic dipole model for actuators. The proposed method has been verified in comparison with finite element simulations and existing calibration methods for magnetic actuators and sensor arrays. In the experiments, the determinant of coefficient (R 2 value) was 99.84% for the sensor system and 99.45% for the actuator system after the calibration, comparable with individual state-of-art calibration methods of calibrating magnetic actuators and sensor arrays. This method has potential to improve the reconfigurability and long-term accuracy of magnetic robot localization and actuation systems, such as magnetically actuated capsule endoscopes.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1132-1139
Magnetically actuated soft capsule endoscope for fine-needle aspiration biopsy
This paper presents a magnetically actuated soft capsule endoscope for fine-needle aspiration biopsy (B-MASCE) in the upper gastrointestinal tract. A thin and hollow needle is attached to the capsule, which can penetrate deeply into tissues to obtain subsurface biopsy sample. The design utilizes a soft elastomer body as a compliant mechanism to guide the needle. An internal permanent magnet provides a means for both actuation and tracking. The capsule is designed to roll towards its target and then deploy the biopsy needle in a precise location selected as the target area. B-MASCE is controlled by multiple custom-designed electromagnets while its position and orientation are tracked by a magnetic sensor array. In in vitro trials, B-MASCE demonstrated rolling locomotion and biopsy of a swine tissue model positioned inside an anatomical human stomach model. It was confirmed after the experiment that a tissue sample was retained inside the needle.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1132-1139
Magnetically actuated soft capsule endoscope for fine-needle aspiration biopsy
This paper presents a magnetically actuated soft capsule endoscope for fine-needle aspiration biopsy (B-MASCE) in the upper gastrointestinal tract. A thin and hollow needle is attached to the capsule, which can penetrate deeply into tissues to obtain subsurface biopsy sample. The design utilizes a soft elastomer body as a compliant mechanism to guide the needle. An internal permanent magnet provides a means for both actuation and tracking. The capsule is designed to roll towards its target and then deploy the biopsy needle in a precise location selected as the target area. B-MASCE is controlled by multiple custom-designed electromagnets while its position and orientation are tracked by a magnetic sensor array. In in vitro trials, B-MASCE demonstrated rolling locomotion and biopsy of a swine tissue model positioned inside an anatomical human stomach model. It was confirmed after the experiment that a tissue sample was retained inside the needle.