Abdul Rahim A. Khaled
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Abdul Rahim A. Khaled has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Kambiz Vafai
Department of Mechanical Engineering, University of California 2 , Riverside, California 92521
15 shared publications K. Vafai
6 shared publicationsA. Ali
2 shared publicationsAli J. Chamkha
2 shared publications- Ali Jawad Chamkha
Faculty of Engineering, Kuwait College of Science and Technology, Doha District, Kuwait
2 shared publications I. Alqadi
King Abdulaziz University, Aeronautical Engineering Department, Jeddah 21589, Saudi Arabia
2 shared publications
Latest Publications
- 12 September 2015
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 29 (9) , 4017-4030
Analysis of laminar film condensation over vertical permeable hollow short fins
- 12 September 2015
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 29 (9) , 4017-4030
Analysis of laminar film condensation over vertical permeable hollow short fins
- Open Access
- 1 July 2015
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 7 (7)
Investigation of heat transfer enhancement inside developing gravity-driven films along a vertical permeable plate subject to nonuniform suction
Flow and heat transfer through the boundary layers of a falling liquid film on a vertical permeable plate subject to nonuniform suction flow are analyzed in this work. The continuity, momentum, and energy equations are transformed to nonsimilar equations and solved using a validated implicit and iterative finite difference method. Increases in the Froude number, Galilei number, and the dimensionless average suction velocity are found to increase the skin friction coefficient, the Nusselt number, and the heat transfer enhancement ratios. These enhancement ratios are noticed to increase at the plate exit as the suction velocity power-law index increases. The Froude number for uniform suction case required to attain the same enhancement ratios due to nonuniform distribution of this suction flow is found to increase as the Galilei number, average suction velocity, and power-law index increase. It is found that the upper most values of the enhancement factors in heat transfer and Froude number are folds when the suction power-law index is equal to . This work demonstrated that significant heat transfer enhancement inside developing gravity-driven liquid films is attainable when properly distributing the suction velocity along the plate.- 1 July 2015
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 7 (7)
Open AccessInvestigation of heat transfer enhancement inside developing gravity-driven films along a vertical permeable plate subject to nonuniform suction
Flow and heat transfer through the boundary layers of a falling liquid film on a vertical permeable plate subject to nonuniform suction flow are analyzed in this work. The continuity, momentum, and energy equations are transformed to nonsimilar equations and solved using a validated implicit and iterative finite difference method. Increases in the Froude number, Galilei number, and the dimensionless average suction velocity are found to increase the skin friction coefficient, the Nusselt number, and the heat transfer enhancement ratios. These enhancement ratios are noticed to increase at the plate exit as the suction velocity power-law index increases. The Froude number for uniform suction case required to attain the same enhancement ratios due to nonuniform distribution of this suction flow is found to increase as the Galilei number, average suction velocity, and power-law index increase. It is found that the upper most values of the enhancement factors in heat transfer and Froude number are folds when the suction power-law index is equal to . This work demonstrated that significant heat transfer enhancement inside developing gravity-driven liquid films is attainable when properly distributing the suction velocity along the plate. - Open Access
- 8 April 2015
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2015, 1-11
Mathematical and Numerical Analysis of Heat Transfer Enhancement by Distribution of Suction Flows inside Permeable Tubes
Heat transfer enhancement in permeable tubes subjected to transverse suction flow is investigated in this work. Both momentum and energy equations are solved analytically and numerically. Both solutions based on negligible entry regions are well matched. Two different suction velocity distributions are considered. A parametric study including the influence of the average suction velocity and the suction velocity profile is conducted for various Peclet numbers. It is found that enhancement of heat transfer over that in impermeable tubes is only possible with large Peclet numbers. This enhancement increases as suction velocities towards the tube outlet increase and as those towards the tube inlet decrease simultaneously. The identified enhancement mechanisms are expanding the entry regions, increasing the transverse advection, and increasing the downstream excess temperatures under same transverse advection. The average suction velocity that produces maximum enhancement increases as the Peclet number increases until it reaches asymptotically its uppermost value at large Peclet numbers. The maximum reported enhancement ratios for the exponential and linear suction velocity distributions are 17.62-fold and 14.67-fold above those for impermeable tubes, respectively. This work demonstrates that significant heat transfer enhancement is attainable when the suction flow inside the permeable tubes is distributed properly.
- 8 April 2015
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2015, 1-11
Open AccessMathematical and Numerical Analysis of Heat Transfer Enhancement by Distribution of Suction Flows inside Permeable Tubes
Heat transfer enhancement in permeable tubes subjected to transverse suction flow is investigated in this work. Both momentum and energy equations are solved analytically and numerically. Both solutions based on negligible entry regions are well matched. Two different suction velocity distributions are considered. A parametric study including the influence of the average suction velocity and the suction velocity profile is conducted for various Peclet numbers. It is found that enhancement of heat transfer over that in impermeable tubes is only possible with large Peclet numbers. This enhancement increases as suction velocities towards the tube outlet increase and as those towards the tube inlet decrease simultaneously. The identified enhancement mechanisms are expanding the entry regions, increasing the transverse advection, and increasing the downstream excess temperatures under same transverse advection. The average suction velocity that produces maximum enhancement increases as the Peclet number increases until it reaches asymptotically its uppermost value at large Peclet numbers. The maximum reported enhancement ratios for the exponential and linear suction velocity distributions are 17.62-fold and 14.67-fold above those for impermeable tubes, respectively. This work demonstrates that significant heat transfer enhancement is attainable when the suction flow inside the permeable tubes is distributed properly.
- 1 November 2014
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 85, 138-150
Heat transfer enhancement in a vertical tube confining two immiscible falling co-flows
- 1 November 2014
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 85, 138-150
Heat transfer enhancement in a vertical tube confining two immiscible falling co-flows
- Open Access
- 25 February 2014
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2014, 1-13
Analysis of Heat Transfers inside Counterflow Plate Heat Exchanger Augmented by an Auxiliary Fluid Flow
Enhancement of heat transfers in counterflow plate heat exchanger due to presence of an intermediate auxiliary fluid flow is investigated. The intermediate auxiliary channel is supported by transverse conducting pins. The momentum and energy equations for the primary fluids are solved numerically and validated against a derived approximate analytical solution. A parametric study including the effect of the various plate heat exchanger, and auxiliary channel dimensionless parameters is conducted. Different enhancement performance indicators are computed. The various trends of parameters that can better enhance heat transfer rates above those for the conventional plate heat exchanger are identified. Large enhancement factors are obtained under fully developed flow conditions. The maximum enhancement factors can be increased by above 8.0- and 5.0-fold for the step and exponential distributions of the pins, respectively. Finally, counterflow plate heat exchangers with auxiliary fluid flows are recommended over the typical ones if these flows can be provided with the least cost.
- 25 February 2014
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2014, 1-13
Open AccessAnalysis of Heat Transfers inside Counterflow Plate Heat Exchanger Augmented by an Auxiliary Fluid Flow
Enhancement of heat transfers in counterflow plate heat exchanger due to presence of an intermediate auxiliary fluid flow is investigated. The intermediate auxiliary channel is supported by transverse conducting pins. The momentum and energy equations for the primary fluids are solved numerically and validated against a derived approximate analytical solution. A parametric study including the effect of the various plate heat exchanger, and auxiliary channel dimensionless parameters is conducted. Different enhancement performance indicators are computed. The various trends of parameters that can better enhance heat transfer rates above those for the conventional plate heat exchanger are identified. Large enhancement factors are obtained under fully developed flow conditions. The maximum enhancement factors can be increased by above 8.0- and 5.0-fold for the step and exponential distributions of the pins, respectively. Finally, counterflow plate heat exchangers with auxiliary fluid flows are recommended over the typical ones if these flows can be provided with the least cost.
- 1 August 2013
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 27 (8) , 2523-2535
Analysis of heat transfer inside wall-joint-fins systems
- 1 August 2013
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 27 (8) , 2523-2535
Analysis of heat transfer inside wall-joint-fins systems
- Open Access
Analysis of Detection Enhancement Using Microcantilevers with Long-Slit-Based Sensors
The present work analyzes theoretically and verifies the advantage of utilizing rectangular microcantilevers with long-slits in microsensing applications. The deflection profile of these microcantilevers is compared with that of typical rectangular microcantilevers under the action of dynamic disturbances. Various force-loading conditions are considered. The theory of linear elasticity for thin beams is used to obtain the deflection-related quantities. The disturbance in these quantities is obtained based on wave propagation and beam vibration theories. It is found that detections of rectangular microcantilevers with long-slits based on maximum slit opening length can be more than 100 times the deflections of typical rectangular microcantilevers. Moreover, the disturbance (noise effect) in the detection quantities of the microcantilever with long-slits is found to be always smaller than that of typical microcantilevers, regardless of the wavelength, force amplitude, and the frequency of the dynamic disturbance. Eventually, the detection quantities of the microcantilever with long-slits are found to be almost unaffected by dynamic disturbances, as long as the wavelengths of these disturbances are larger than 3.5 times the microcantilever width. Finally, the present work recommends implementation of microcantilevers with long-slits as microsensors in robust applications, including real analyte environments and out of laboratory testing.
Open AccessAnalysis of Detection Enhancement Using Microcantilevers with Long-Slit-Based Sensors
The present work analyzes theoretically and verifies the advantage of utilizing rectangular microcantilevers with long-slits in microsensing applications. The deflection profile of these microcantilevers is compared with that of typical rectangular microcantilevers under the action of dynamic disturbances. Various force-loading conditions are considered. The theory of linear elasticity for thin beams is used to obtain the deflection-related quantities. The disturbance in these quantities is obtained based on wave propagation and beam vibration theories. It is found that detections of rectangular microcantilevers with long-slits based on maximum slit opening length can be more than 100 times the deflections of typical rectangular microcantilevers. Moreover, the disturbance (noise effect) in the detection quantities of the microcantilever with long-slits is found to be always smaller than that of typical microcantilevers, regardless of the wavelength, force amplitude, and the frequency of the dynamic disturbance. Eventually, the detection quantities of the microcantilever with long-slits are found to be almost unaffected by dynamic disturbances, as long as the wavelengths of these disturbances are larger than 3.5 times the microcantilever width. Finally, the present work recommends implementation of microcantilevers with long-slits as microsensors in robust applications, including real analyte environments and out of laboratory testing.
- Open Access
- 1 January 2013
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 5
Generalized Correlations for Heat Transfer through High Performance Fins
Analysis of heat transfer through different candidates for high performance fins is considered in this work. These candidates are: (A) fins of constant cross-sectional area, (B) fins of constant cross-sectional area gradient, and (C) radial fins with power-law cross-sectional area distribution. The types (A) and (B) fins are allowed having variable power-law profile distributions. The energy equation for each case is solved analytically, and closed form equations for various performance indicators including the fin efficiency are obtained. It is identified that high performance fins are those fins having larger tip and surface areas and smaller tip thickness than those of the straight fin. These effects tend to augment the fin heat transfer rate. One of the indicators of the type (A) fins is found to become dependent on the tip thickness when it is smaller than the base thickness and for thermal lengths larger than 1.5. The type (C) fins are found to transfer more thermal energy than the type (B) fins under same tip area and tip thickness. Finally, generalized correlations for the fin efficiency of high performance fins as function of base and tip areas and thicknesses and the thermal length are proposed and validated.
- 1 January 2013
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 5
Open AccessGeneralized Correlations for Heat Transfer through High Performance Fins
Analysis of heat transfer through different candidates for high performance fins is considered in this work. These candidates are: (A) fins of constant cross-sectional area, (B) fins of constant cross-sectional area gradient, and (C) radial fins with power-law cross-sectional area distribution. The types (A) and (B) fins are allowed having variable power-law profile distributions. The energy equation for each case is solved analytically, and closed form equations for various performance indicators including the fin efficiency are obtained. It is identified that high performance fins are those fins having larger tip and surface areas and smaller tip thickness than those of the straight fin. These effects tend to augment the fin heat transfer rate. One of the indicators of the type (A) fins is found to become dependent on the tip thickness when it is smaller than the base thickness and for thermal lengths larger than 1.5. The type (C) fins are found to transfer more thermal energy than the type (B) fins under same tip area and tip thickness. Finally, generalized correlations for the fin efficiency of high performance fins as function of base and tip areas and thicknesses and the thermal length are proposed and validated.
- 6 August 2012
- Published by Elsevier in Energy and Buildings
- Vol. 54, 131-140
Theoretical investigation on thermal insulation performance of closed cavity containing a hollow cylinder
- 6 August 2012
- Published by Elsevier in Energy and Buildings
- Vol. 54, 131-140
Theoretical investigation on thermal insulation performance of closed cavity containing a hollow cylinder
- 23 March 2012
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 22 (2) , 194-214
Augmentation of heat transfer in wall‐rooted‐fins systems
Purpose: The purpose of this work is to consider heat transfer inside wall‐rooted‐fins systems.Design/methodology/approach: The coupled two‐dimensional heat diffusion equations are nondimensionlaized and solved numerically using an iterative finite volume method. Approximate fine analytical solutions for various augmentation indicators are derived. Excellent agreement is obtained between the numerical and the analytical results. A parametric study including all of the involved dimensionless parameters is conducted and presented graphically. Accurate correlations are generated.Findings: It is found that fin‐roots with large root lengths experience bi‐directional heat transfer rates. Moreover, the wall‐rooted‐fins system is found to possess an effectiveness that can be more than 60 percent above that with rootless fins at wall Biot numbers of unity order. This value is found to increase as the Biot number increases or as the wall‐to‐fin thermal conductivities and volumes ratios decrease. In addition, heat transfer rates through wall‐rooted‐fins systems can be more than 100 percent above those having uniform thermal conductivities. Eventually, the heat transfer coefficient between the fin‐roots and wall are derived, which is found to be independent on the wall thickness.Originality/value: Finally, this work paves a way for an effective passive method for augmenting heat transfer inside wall‐fins systems.
- 23 March 2012
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 22 (2) , 194-214
Augmentation of heat transfer in wall‐rooted‐fins systems
Purpose: The purpose of this work is to consider heat transfer inside wall‐rooted‐fins systems.Design/methodology/approach: The coupled two‐dimensional heat diffusion equations are nondimensionlaized and solved numerically using an iterative finite volume method. Approximate fine analytical solutions for various augmentation indicators are derived. Excellent agreement is obtained between the numerical and the analytical results. A parametric study including all of the involved dimensionless parameters is conducted and presented graphically. Accurate correlations are generated.Findings: It is found that fin‐roots with large root lengths experience bi‐directional heat transfer rates. Moreover, the wall‐rooted‐fins system is found to possess an effectiveness that can be more than 60 percent above that with rootless fins at wall Biot numbers of unity order. This value is found to increase as the Biot number increases or as the wall‐to‐fin thermal conductivities and volumes ratios decrease. In addition, heat transfer rates through wall‐rooted‐fins systems can be more than 100 percent above those having uniform thermal conductivities. Eventually, the heat transfer coefficient between the fin‐roots and wall are derived, which is found to be independent on the wall thickness.Originality/value: Finally, this work paves a way for an effective passive method for augmenting heat transfer inside wall‐fins systems.