Chih-Kai Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chih-Kai Hong has a total of 193 co-authors. Here are the top co-authors by number of shared publications:
- Wei-Ren Su
Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Musculoskeletal Research Center, Innovation Headquarter, National Cheng Kung University, Tainan, Taiwan
46 shared publications - Kai-Lan Hsu
Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
22 shared publications Fa-Chuan Kuan
Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
20 shared publications- Fa-Chuan Kuan
Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
16 shared publications - Cheng-Li Lin
Department of Orthopedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
14 shared publications Kai-Lan Hsu
Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
12 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3649
The Evaluation of Developmental Dysplasia of Hip from Pediatric Ultrasound Images by Key Point-Based Deep Learning
Background: Developmental dysplasia of the hip (DDH) is a common hip disorder in infants. Ultrasound is the primary imaging modality for infants younger than 6 months, but measurements using the Graf and Harcke methods depend on examiner experience. This study aimed to develop and internally validate a key point-based deep learning model for the automated measurement of the Graf α and β angles and femoral head coverage. Methods: A total of 300 standard-plane hip ultrasound images from 165 infants aged 0–6 months were retrospectively collected at a single tertiary center, and reference key points were determined by consensus of pediatric orthopedic surgeons. We developed a dual-branch network, named “DDH-KPNet,” which combines a UNet++ convolutional branch and a transformer branch fused with attention modules. Performance was evaluated with fivefold cross-validation at three levels: accuracy of key point localization; intraclass correlation coefficient (ICC); and DDH classification. Results: The experimental results demonstrated that Graf-based classification achieved accuracy = 0.903, sensitivity = 0.81, and specificity = 0.9497 (under 95% conference interval); Harcke classification achieved accuracy = 0.942, sensitivity = 0.888, and specificity = 0.968 (under 95% conference interval); and ICCs for α = 0.832, β = 0.728, and coverage = 0.923. Conclusions: The proposed model showed promising agreement with expert measurements under internal validation. Multicenter external validation and independent diagnostic analysis by different physicians are required before clinical implementation.
- 4 November 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3649
Open AccessThe Evaluation of Developmental Dysplasia of Hip from Pediatric Ultrasound Images by Key Point-Based Deep Learning
Background: Developmental dysplasia of the hip (DDH) is a common hip disorder in infants. Ultrasound is the primary imaging modality for infants younger than 6 months, but measurements using the Graf and Harcke methods depend on examiner experience. This study aimed to develop and internally validate a key point-based deep learning model for the automated measurement of the Graf α and β angles and femoral head coverage. Methods: A total of 300 standard-plane hip ultrasound images from 165 infants aged 0–6 months were retrospectively collected at a single tertiary center, and reference key points were determined by consensus of pediatric orthopedic surgeons. We developed a dual-branch network, named “DDH-KPNet,” which combines a UNet++ convolutional branch and a transformer branch fused with attention modules. Performance was evaluated with fivefold cross-validation at three levels: accuracy of key point localization; intraclass correlation coefficient (ICC); and DDH classification. Results: The experimental results demonstrated that Graf-based classification achieved accuracy = 0.903, sensitivity = 0.81, and specificity = 0.9497 (under 95% conference interval); Harcke classification achieved accuracy = 0.942, sensitivity = 0.888, and specificity = 0.968 (under 95% conference interval); and ICCs for α = 0.832, β = 0.728, and coverage = 0.923. Conclusions: The proposed model showed promising agreement with expert measurements under internal validation. Multicenter external validation and independent diagnostic analysis by different physicians are required before clinical implementation.
- Open Access
- 21 October 2026
- Published by Elsevier in Journal of the Formosan Medical Association
Living in a shared room is associated with worse pain and sleep during hospital admission after arthroscopic rotator cuff repair
- 21 October 2026
- Published by Elsevier in Journal of the Formosan Medical Association
Open AccessLiving in a shared room is associated with worse pain and sleep during hospital admission after arthroscopic rotator cuff repair
- Open Access
- 8 October 2026
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- p. e70099
Variation Exists Among Asia Pacific and American Surgeons in the Treatment of Pediatric Tibial Eminence Fractures
Purpose: To compare operative and nonoperative management strategies, fixation preferences, postoperative immobilization protocols, and approaches to managing postoperative complications among Asia Pacific (APAC) and North American surgeons. Methods: An online survey was distributed to orthopaedic surgeons within the Pediatric Research in Sports Medicine APAC group between January 2023 and June 2024. The survey, which is a modified version of the Pediatric Orthopaedic Society of North America (POSNA) survey, assessed surgeon demographics, treatment strategies, risk factors for postoperative arthrofibrosis, and responses to clinical vignettes. Results: Fifty‐six out of 127 APAC surgeons responded to the survey. Compared with POSNA surgeons, APAC respondents were more likely to perform arthroscopic reduction and transphyseal suture fixation for type II (89.3% vs 37.4%, P < .001) tibial spine fracture regardless of patient's age. APAC surgeons also favored longer postoperative immobilization periods (14.3% vs 24.5%, P = .023) and identified time from injury to surgery (76.8% vs 31.9%, P < .001) as the main risk factor for arthrofibrosis. APAC surgeons were also more likely to manage early postoperative range‐of‐motion restriction nonoperatively with continued physiotherapy, whereas POSNA surgeons leaned toward arthroscopic lysis of adhesions (53.6% vs 33.6%, P = .015). Conclusions: Although there was a 5‐year gap between surveys, APAC surgeons were more likely than POSNA surgeons to perform arthroscopic reduction and transphyseal suture fixation for type 2 tibial spine fracture, favored longer postoperative immobilization, more frequently identified time from injury to surgery as the primary risk factor for arthrofibrosis, and were more inclined to manage early postoperative range‐of‐motion restriction nonoperatively. Clinical Relevance: Understanding regional differences in the management of tibial spine fractures may help identify areas of consensus and variation, inform best‐practice guidelines, and ultimately improve patient outcomes.
- 8 October 2026
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- p. e70099
Open AccessVariation Exists Among Asia Pacific and American Surgeons in the Treatment of Pediatric Tibial Eminence Fractures
Purpose: To compare operative and nonoperative management strategies, fixation preferences, postoperative immobilization protocols, and approaches to managing postoperative complications among Asia Pacific (APAC) and North American surgeons. Methods: An online survey was distributed to orthopaedic surgeons within the Pediatric Research in Sports Medicine APAC group between January 2023 and June 2024. The survey, which is a modified version of the Pediatric Orthopaedic Society of North America (POSNA) survey, assessed surgeon demographics, treatment strategies, risk factors for postoperative arthrofibrosis, and responses to clinical vignettes. Results: Fifty‐six out of 127 APAC surgeons responded to the survey. Compared with POSNA surgeons, APAC respondents were more likely to perform arthroscopic reduction and transphyseal suture fixation for type II (89.3% vs 37.4%, P < .001) tibial spine fracture regardless of patient's age. APAC surgeons also favored longer postoperative immobilization periods (14.3% vs 24.5%, P = .023) and identified time from injury to surgery (76.8% vs 31.9%, P < .001) as the main risk factor for arthrofibrosis. APAC surgeons were also more likely to manage early postoperative range‐of‐motion restriction nonoperatively with continued physiotherapy, whereas POSNA surgeons leaned toward arthroscopic lysis of adhesions (53.6% vs 33.6%, P = .015). Conclusions: Although there was a 5‐year gap between surveys, APAC surgeons were more likely than POSNA surgeons to perform arthroscopic reduction and transphyseal suture fixation for type 2 tibial spine fracture, favored longer postoperative immobilization, more frequently identified time from injury to surgery as the primary risk factor for arthrofibrosis, and were more inclined to manage early postoperative range‐of‐motion restriction nonoperatively. Clinical Relevance: Understanding regional differences in the management of tibial spine fractures may help identify areas of consensus and variation, inform best‐practice guidelines, and ultimately improve patient outcomes.
- Open Access
- 29 August 2026
- Published by Elsevier in Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology
- Vol. 46, 55-59
Prediction of massive rotator cuff tears classified as type B or C in the Collin classification using radiographic measurements
- 29 August 2026
- Published by Elsevier in Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology
- Vol. 46, 55-59
Open AccessPrediction of massive rotator cuff tears classified as type B or C in the Collin classification using radiographic measurements
- 16 August 2026
- Published by Wiley in Developmental Medicine & Child Neurology
Combined pelvic osteotomy and proximal femoral‐guided growth in children with cerebral palsy and hip displacement
Aim: To evaluate radiographic outcomes after combined pelvic osteotomy and proximal femoral‐guided growth in children with cerebral palsy (CP) and hip displacement. Method: We retrospectively reviewed 32 children (14 males, 18 females) with CP (51 hips) treated with combined pelvic osteotomy and guided growth between 2016 and 2022. Indications were a migration percentage greater than 40%, a head‐shaft angle (HSA) greater than 155°, and an acetabular index (≥ 22°). Mean age at surgery was 6 years (range 4–8 years 6 months) with a minimum 2‐year follow‐up. Gross Motor Function Classification System (GMFCS) levels were: seven in GMFCS level III, 20 in GMFCS level IV, and five in GMFCS level V. Radiographic parameters were assessed serially. Poor outcome was defined as a migration percentage of 50% or greater at the final review. Results: HSA, acetabular index, and migration percentage improved significantly (−9.5°, −7.2°, −28%; all p < 0.001). Generalized estimating equation models showed progressive decreases in HSA with the follow‐up (−2.9° per interval, p < 0.001) and lower HSA in older children (−3° per year, p < 0.001). The acetabular index showed an early postoperative reduction with smaller longitudinal changes and was higher in children with greater motor impairment (+3.6° per GMFCS level, p = 0.003). The migration percentage improved markedly and continued to decline with the follow‐up (−6% per interval, p < 0.001), but was significantly higher in children classified in higher GMFCS levels (+9.9% per level, p = 0.001). Five hips (9%) had poor outcomes, mostly with a baseline migration percentage of 80% or greater. Interpretation: While favourable outcomes were generally observed in hips with moderate displacement (approximate migration percentage 40%–60%), those with more severe displacement (e.g. a migration percentage of 80% or more) demonstrated less consistent correction and may ultimately require additional reconstruction.
- 16 August 2026
- Published by Wiley in Developmental Medicine & Child Neurology
Combined pelvic osteotomy and proximal femoral‐guided growth in children with cerebral palsy and hip displacement
Aim: To evaluate radiographic outcomes after combined pelvic osteotomy and proximal femoral‐guided growth in children with cerebral palsy (CP) and hip displacement. Method: We retrospectively reviewed 32 children (14 males, 18 females) with CP (51 hips) treated with combined pelvic osteotomy and guided growth between 2016 and 2022. Indications were a migration percentage greater than 40%, a head‐shaft angle (HSA) greater than 155°, and an acetabular index (≥ 22°). Mean age at surgery was 6 years (range 4–8 years 6 months) with a minimum 2‐year follow‐up. Gross Motor Function Classification System (GMFCS) levels were: seven in GMFCS level III, 20 in GMFCS level IV, and five in GMFCS level V. Radiographic parameters were assessed serially. Poor outcome was defined as a migration percentage of 50% or greater at the final review. Results: HSA, acetabular index, and migration percentage improved significantly (−9.5°, −7.2°, −28%; all p < 0.001). Generalized estimating equation models showed progressive decreases in HSA with the follow‐up (−2.9° per interval, p < 0.001) and lower HSA in older children (−3° per year, p < 0.001). The acetabular index showed an early postoperative reduction with smaller longitudinal changes and was higher in children with greater motor impairment (+3.6° per GMFCS level, p = 0.003). The migration percentage improved markedly and continued to decline with the follow‐up (−6% per interval, p < 0.001), but was significantly higher in children classified in higher GMFCS levels (+9.9% per level, p = 0.001). Five hips (9%) had poor outcomes, mostly with a baseline migration percentage of 80% or greater. Interpretation: While favourable outcomes were generally observed in hips with moderate displacement (approximate migration percentage 40%–60%), those with more severe displacement (e.g. a migration percentage of 80% or more) demonstrated less consistent correction and may ultimately require additional reconstruction.
- Open Access
- 15 July 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1)
Comparison of pediatric proximal femoral locking plates and dynamic hip screws in the fixation of pediatric intertrochanteric fractures, a biomechanical study.
Treatment options for pediatric intertrochanteric fractures range from conservative casting in young children to surgical fixation in older patients, most commonly using dynamic hip screws (DHS) or pediatric proximal femoral locking plates (PF-LCP). As there is limited biomechanical evidence favoring one method over another, this study aimed to compare the biomechanical stability of DHS and PF-LCP for the treatment of pediatric intertrochanteric fractures using a synthetic bone model. Sixteen synthetic composite femurs were allocated into two groups stabilized with either a DHS or a PF-LCP. To simulate Delbet type IV intertrochanteric fractures, a vertical osteotomy was created in each specimen. Biomechanical evaluation was carried out using a universal testing machine, assessing axial stiffness, vertical, horizontal, and total displacement, as well as ultimate load to failure under standardized loading conditions. Comparative statistical analyses were then performed to determine differences in biomechanical performance between the two fixation methods. Group P demonstrated significantly smaller vertical and total displacements (0.15 ± 0.15 mm and 0.41 ± 0.31 mm) compared with the DHS group (0.59 ± 0.42 mm and 0.75 ± 0.33 mm) (p = 0.018 and p = 0.045), whereas horizontal displacement showed no difference (p = 0.142). Axial stiffness and ultimate failure load were comparable between groups. All specimens failed at the level of the most distal screw; however, fracture sites occurred significantly more distal in the DHS group (89.7 ± 3.1 mm) than in the PF-LCP group (62.1 ± 2.3 mm, p < 0.001). In a synthetic bone model, PF-LCP group showed less vertical and total displacement than the DHS when fixing intertrochanteric fractures. This suggests that the locking plate may offer a stronger and safer option for treating pediatric intertrochanteric fractures.
- 15 July 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1)
Open AccessComparison of pediatric proximal femoral locking plates and dynamic hip screws in the fixation of pediatric intertrochanteric fractures, a biomechanical study.
Treatment options for pediatric intertrochanteric fractures range from conservative casting in young children to surgical fixation in older patients, most commonly using dynamic hip screws (DHS) or pediatric proximal femoral locking plates (PF-LCP). As there is limited biomechanical evidence favoring one method over another, this study aimed to compare the biomechanical stability of DHS and PF-LCP for the treatment of pediatric intertrochanteric fractures using a synthetic bone model. Sixteen synthetic composite femurs were allocated into two groups stabilized with either a DHS or a PF-LCP. To simulate Delbet type IV intertrochanteric fractures, a vertical osteotomy was created in each specimen. Biomechanical evaluation was carried out using a universal testing machine, assessing axial stiffness, vertical, horizontal, and total displacement, as well as ultimate load to failure under standardized loading conditions. Comparative statistical analyses were then performed to determine differences in biomechanical performance between the two fixation methods. Group P demonstrated significantly smaller vertical and total displacements (0.15 ± 0.15 mm and 0.41 ± 0.31 mm) compared with the DHS group (0.59 ± 0.42 mm and 0.75 ± 0.33 mm) (p = 0.018 and p = 0.045), whereas horizontal displacement showed no difference (p = 0.142). Axial stiffness and ultimate failure load were comparable between groups. All specimens failed at the level of the most distal screw; however, fracture sites occurred significantly more distal in the DHS group (89.7 ± 3.1 mm) than in the PF-LCP group (62.1 ± 2.3 mm, p < 0.001). In a synthetic bone model, PF-LCP group showed less vertical and total displacement than the DHS when fixing intertrochanteric fractures. This suggests that the locking plate may offer a stronger and safer option for treating pediatric intertrochanteric fractures.
- Open Access
- 1 July 2026
- Published by Wolters Kluwer Health in Formosan Journal of Musculoskeletal Disorders
- Vol. 17 (3) , 147-151
A Bibliometric Analysis of the Most-cited Articles in the Formosan Journal of Musculoskeletal Disorders
Background: The Formosan Journal of Musculoskeletal Disorders (FJMD), the official journal of the Taiwan Orthopaedic Association, has served as a platform for musculoskeletal research since 2010. In 2025, it was indexed in the Directory of Open Access Journals, enhancing its global visibility. However, its publication output has not been examined through bibliometric analysis, which can provide insights into scholarly influence and guide strategic development. Objectives: To identify the most-cited articles in FJMD from 2010 to 2025 and analyze citation trends across different publication types. Materials and Methods: A comprehensive search of FJMD publications (2010–2025) was conducted on June 30, 2025, via the Taiwan Orthopaedic Association website. Article type, title, and authors were recorded. Citation counts were retrieved from Google Scholar. The top 10 original articles, 5 review articles, and 5 case reports were identified. Group comparisons were performed using the Mann–Whitney U -test, with significance set at P < 0.05. Results: Among 422 articles, the mean annual citation count was 28 (range, 0–143). Articles published from 2010 to 2013 had significantly higher mean citations per article (3.6 ± 4.1) than those from 2014 to 2025 (0.25 ± 0.7; P < 0.001). The most-cited original articles (mean, 14 citations) primarily addressed traumatology, spine, sports, and basic research. Review articles (mean, 5 citations) focused on arthroplasty, osteoporosis, pediatrics, and hip disorders. Case reports with ≥5 citations were mostly in traumatology. Conclusions: Citation activity in FJMD peaked between 2010 and 2013, coinciding with publication under an international publisher, and declined thereafter. Publisher visibility, indexing in major databases, and article accessibility likely influence citation performance. Strategic promotion and rigorous editorial standards may enhance future impact.
- 1 July 2026
- Published by Wolters Kluwer Health in Formosan Journal of Musculoskeletal Disorders
- Vol. 17 (3) , 147-151
Open AccessA Bibliometric Analysis of the Most-cited Articles in the Formosan Journal of Musculoskeletal Disorders
Background: The Formosan Journal of Musculoskeletal Disorders (FJMD), the official journal of the Taiwan Orthopaedic Association, has served as a platform for musculoskeletal research since 2010. In 2025, it was indexed in the Directory of Open Access Journals, enhancing its global visibility. However, its publication output has not been examined through bibliometric analysis, which can provide insights into scholarly influence and guide strategic development. Objectives: To identify the most-cited articles in FJMD from 2010 to 2025 and analyze citation trends across different publication types. Materials and Methods: A comprehensive search of FJMD publications (2010–2025) was conducted on June 30, 2025, via the Taiwan Orthopaedic Association website. Article type, title, and authors were recorded. Citation counts were retrieved from Google Scholar. The top 10 original articles, 5 review articles, and 5 case reports were identified. Group comparisons were performed using the Mann–Whitney U -test, with significance set at P < 0.05. Results: Among 422 articles, the mean annual citation count was 28 (range, 0–143). Articles published from 2010 to 2013 had significantly higher mean citations per article (3.6 ± 4.1) than those from 2014 to 2025 (0.25 ± 0.7; P < 0.001). The most-cited original articles (mean, 14 citations) primarily addressed traumatology, spine, sports, and basic research. Review articles (mean, 5 citations) focused on arthroplasty, osteoporosis, pediatrics, and hip disorders. Case reports with ≥5 citations were mostly in traumatology. Conclusions: Citation activity in FJMD peaked between 2010 and 2013, coinciding with publication under an international publisher, and declined thereafter. Publisher visibility, indexing in major databases, and article accessibility likely influence citation performance. Strategic promotion and rigorous editorial standards may enhance future impact.
- Open Access
- 2 May 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 169
Assessing PHILOS plate as an alternative fixation method for pediatric femoral neck fractures: a biomechanical comparison with cannulated screws
Background Pediatric femoral neck fractures require stable fixation to avoid complications. It remains unclear whether fixation with the Proximal Humeral Internal Locking System (PHILOS) can serve as an alternative to cannulated screw fixation. The purpose of this study was to compare the biomechanical properties of PHILOS and cannulated screws for stabilizing unstable pediatric femoral neck fractures using a synthetic bone model. Materials and methods Twelve fourth-generation synthetic composite femurs were randomly assigned to screw fixation (Group S) or PHILOS fixation (Group P) (n = 6 each). A standardized vertically oriented Delbet type II osteotomy was created in all specimens. Group S was fixed with three 6.5-mm cannulated screws, whereas Group P received a PHILOS plate with 3.5-mm locking screws. Each specimen underwent a standardized loading protocol using a universal testing machine. Axial stiffness, cyclic displacement, ultimate failure load, and failure modes were recorded and statistically compared between groups. Results No statistically significant difference was found in axial stiffness between Group P (746 ± 300 N/mm) and Group S (753 ± 256 N/mm) (p = 1.000). Displacement after cyclic loading was significantly greater in Group P (1.42 ± 0.3 mm) compared with Group S (0.57 ± 0.2 mm) (p = 0.004). The ultimate failure load was higher in Group S (2378 ± 513 N) than it was in Group P (1652 ± 206 N) (p = 0.025). Upon reaching ultimate load, all specimens in both groups failed at the femoral head region due to femoral head broken. Conclusions The adult PHILOS plate with 3.5-mm locking screws demonstrated inferior biomechanical stability compared with three 6.5-mm cannulated screws in this synthetic composite femur model. Level of evidence Controlled laboratory study.
- 2 May 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 169
Open AccessAssessing PHILOS plate as an alternative fixation method for pediatric femoral neck fractures: a biomechanical comparison with cannulated screws
Background Pediatric femoral neck fractures require stable fixation to avoid complications. It remains unclear whether fixation with the Proximal Humeral Internal Locking System (PHILOS) can serve as an alternative to cannulated screw fixation. The purpose of this study was to compare the biomechanical properties of PHILOS and cannulated screws for stabilizing unstable pediatric femoral neck fractures using a synthetic bone model. Materials and methods Twelve fourth-generation synthetic composite femurs were randomly assigned to screw fixation (Group S) or PHILOS fixation (Group P) (n = 6 each). A standardized vertically oriented Delbet type II osteotomy was created in all specimens. Group S was fixed with three 6.5-mm cannulated screws, whereas Group P received a PHILOS plate with 3.5-mm locking screws. Each specimen underwent a standardized loading protocol using a universal testing machine. Axial stiffness, cyclic displacement, ultimate failure load, and failure modes were recorded and statistically compared between groups. Results No statistically significant difference was found in axial stiffness between Group P (746 ± 300 N/mm) and Group S (753 ± 256 N/mm) (p = 1.000). Displacement after cyclic loading was significantly greater in Group P (1.42 ± 0.3 mm) compared with Group S (0.57 ± 0.2 mm) (p = 0.004). The ultimate failure load was higher in Group S (2378 ± 513 N) than it was in Group P (1652 ± 206 N) (p = 0.025). Upon reaching ultimate load, all specimens in both groups failed at the femoral head region due to femoral head broken. Conclusions The adult PHILOS plate with 3.5-mm locking screws demonstrated inferior biomechanical stability compared with three 6.5-mm cannulated screws in this synthetic composite femur model. Level of evidence Controlled laboratory study.