Mohtar Yunianto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mohtar Yunianto has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Fuad Anwar
Physics Department, Universitas Sebelas Maret
10 shared publicationsCari Cari
Physics Department, Universitas Sebelas Maret
7 shared publications- Cari Cari
Faculties Member of Physics Department, Universitas Sebelas Maret, Surakarta, Indonesia
6 shared publications Suharyana Suharyana
Physics Department, Universitas Sebelas Maret
5 shared publicationsA. Suparmi
Department of Physics, Faculty of Mathematics and Natural Sciences, Sebelas Maret University, Surakarta, Indonesia
4 shared publications- Ahmad Marzuki
Department of Physics, Universitas Sebelas Maret - Indonesia, Indonesia
4 shared publications
Latest Publications
- Open Access
- 25 November 2026
- Published by Springer Nature in The Egyptian Journal of Bronchology
- Vol. 20  (1)
Radiomics-based shape feature analysis and machine learning classification of primary NSCLC tumors and mediastinal lymph nodes using TCIA data
Background: Primary non-small cell lung cancer (NSCLC) tumors and mediastinal lymph nodes differ in morphology, but these differences have rarely been quantified with reproducible imaging descriptors. Although anatomical localization on CT imaging aids in distinguishing between lesions, precise quantitative characterization of their morphological differences remains an open research question. Radiomics is a quantitative framework that, when combined with machine learning, enables the systematic extraction of imaging biomarkers beyond what visual assessment can provide. Objectives: This study aimed to investigate the use of shape-based radiomics features and machine-learning classifiers to quantify and characterize the morphological differences between these two types. Methods: The Cancer Imaging Archive (TCIA) was used to access data, including QIN-Lung, LungFCP, CPTAC-LUAD, CPTAC-LSCC, Non-Small Cell Lung Cancer, and Mediastinal-Lymph-Node-SEG collections, comprising 220 patients (112 primary NSCLC tumors and 108 mediastinal lymph nodes from oncology patients, 55 of whom had NSCLC). Shape features (sphericity, elongation, and flatness) and one first-order intensity feature (mean Hounsfield units, HU) were extracted from the CT images with PyRadiomics. Outlier elimination and z-score standardization of the extracted feature values were fitted on training data only. Five classifiers, including Support Vector Machine (SVM), Random Forest, XGBoost, Logistic Regression, and K-Nearest Neighbors (KNN), were evaluated using patient-level stratified 5-fold nested cross-validation with bootstrap 95% confidence intervals. Statistical group differences were assessed using independent t-tests with false discovery rate (FDR) correction for multiple comparisons. For external testing, models trained on the remaining collections were applied to 38 held-out CPTAC-LUAD tumors and 90 mediastinal lymph nodes from a different institution (TCIA CT Lymph Nodes collection). Results: The shape descriptors and mean HU were statistically different between primary lung tumors and mediastinal lymph nodes (FDR-adjusted p < 0.005 for sphericity, elongation, flatness, and mean HU). Lymph nodes were more spherical but more elongated and flattened (ovoid) than primary tumors. Under proper nested cross-validation, SVM achieved an ROC-AUC of 0.969 (95% CI: 0.924–0.984) and a mean accuracy of 92.7%, while Random Forest achieved the highest mean accuracy at 93.6% (AUC = 0.956). All five classifiers demonstrated consistent performance (AUC range: 0.933–0.969). On the external test set, AUC was 0.928 for SVM and 0.927 for Logistic Regression (range across models 0.804–0.928), and 0.942 for SVM using the three shape features alone. Conclusion: Shape-based radiomic features quantify systematic morphological differences between primary NSCLC tumors and mediastinal lymph nodes and allow the two lesion types to be classified accurately, including on an external test set from a different institution. The model does not detect nodal metastasis and has not been evaluated for clinical use; validation outside public TCIA data is needed.
- 25 November 2026
- Published by Springer Nature in The Egyptian Journal of Bronchology
- Vol. 20  (1)
Open AccessRadiomics-based shape feature analysis and machine learning classification of primary NSCLC tumors and mediastinal lymph nodes using TCIA data
Background: Primary non-small cell lung cancer (NSCLC) tumors and mediastinal lymph nodes differ in morphology, but these differences have rarely been quantified with reproducible imaging descriptors. Although anatomical localization on CT imaging aids in distinguishing between lesions, precise quantitative characterization of their morphological differences remains an open research question. Radiomics is a quantitative framework that, when combined with machine learning, enables the systematic extraction of imaging biomarkers beyond what visual assessment can provide. Objectives: This study aimed to investigate the use of shape-based radiomics features and machine-learning classifiers to quantify and characterize the morphological differences between these two types. Methods: The Cancer Imaging Archive (TCIA) was used to access data, including QIN-Lung, LungFCP, CPTAC-LUAD, CPTAC-LSCC, Non-Small Cell Lung Cancer, and Mediastinal-Lymph-Node-SEG collections, comprising 220 patients (112 primary NSCLC tumors and 108 mediastinal lymph nodes from oncology patients, 55 of whom had NSCLC). Shape features (sphericity, elongation, and flatness) and one first-order intensity feature (mean Hounsfield units, HU) were extracted from the CT images with PyRadiomics. Outlier elimination and z-score standardization of the extracted feature values were fitted on training data only. Five classifiers, including Support Vector Machine (SVM), Random Forest, XGBoost, Logistic Regression, and K-Nearest Neighbors (KNN), were evaluated using patient-level stratified 5-fold nested cross-validation with bootstrap 95% confidence intervals. Statistical group differences were assessed using independent t-tests with false discovery rate (FDR) correction for multiple comparisons. For external testing, models trained on the remaining collections were applied to 38 held-out CPTAC-LUAD tumors and 90 mediastinal lymph nodes from a different institution (TCIA CT Lymph Nodes collection). Results: The shape descriptors and mean HU were statistically different between primary lung tumors and mediastinal lymph nodes (FDR-adjusted p < 0.005 for sphericity, elongation, flatness, and mean HU). Lymph nodes were more spherical but more elongated and flattened (ovoid) than primary tumors. Under proper nested cross-validation, SVM achieved an ROC-AUC of 0.969 (95% CI: 0.924–0.984) and a mean accuracy of 92.7%, while Random Forest achieved the highest mean accuracy at 93.6% (AUC = 0.956). All five classifiers demonstrated consistent performance (AUC range: 0.933–0.969). On the external test set, AUC was 0.928 for SVM and 0.927 for Logistic Regression (range across models 0.804–0.928), and 0.942 for SVM using the three shape features alone. Conclusion: Shape-based radiomic features quantify systematic morphological differences between primary NSCLC tumors and mediastinal lymph nodes and allow the two lesion types to be classified accurately, including on an external test set from a different institution. The model does not detect nodal metastasis and has not been evaluated for clinical use; validation outside public TCIA data is needed.
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM-Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 12  (59) , 411-422
From Classical Filtering to Adaptive and AI-Driven Paradigms: A PRISMA-Based Systematic Review and Bibliometric Analysis of EMG Signal Filtering
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM-Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 12  (59) , 411-422
From Classical Filtering to Adaptive and AI-Driven Paradigms: A PRISMA-Based Systematic Review and Bibliometric Analysis of EMG Signal Filtering
- Open Access
- 1 October 2025
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 15  (2) , 399-408
Performance Analysis of EPC Material as a Kidney Organ Phantom with Exposure Voltage Variations and PA-GF-Based Kidney Stone Size
Research in the field of radiodiagnostics has been extensively developed, creating the need for substitute objects to represent human organs—namely, radiological phantoms. A phantom is a simulated model of an organ fabricated using 3D printing technology. This study aims to evaluate the suitability of Expanded Polyamide – Glass Fiber (EPA-GF) as a kidney stone phantom material embedded within a kidney phantom, based on parameters such as material density, CT number, electron density, and radiation dose across various CT scan exposure voltages. The phantom samples were printed using a dual-extruder 3D printer, with Expanded Polycarbonate (EPC) used as the kidney phantom material. CT scan exposure voltages were set to 80 kV, 100 kV, and 120 kV. Kidney stone sizes used in this study ranged from 1 mm to 8 mm (1 mm, 2 mm, 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, and 8 mm). The measured density of EPA-GF was 1.51 ± 0.06 g/cm³. The CT numbers obtained at each voltage were 373.30 HU, 329.05 HU, and 299.46 HU, respectively. The corresponding electron density values were 1.231, 1.210, and 1.196, respectively. The effective doses measured at each voltage were 0.0240 mSv, 0.0448 mSv, and 0.0798 mSv. All parameter values were found to be closely aligned with literature references. The smallest visible kidney stone size detected was 2 mm.
- 1 October 2025
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 15  (2) , 399-408
Open AccessPerformance Analysis of EPC Material as a Kidney Organ Phantom with Exposure Voltage Variations and PA-GF-Based Kidney Stone Size
Research in the field of radiodiagnostics has been extensively developed, creating the need for substitute objects to represent human organs—namely, radiological phantoms. A phantom is a simulated model of an organ fabricated using 3D printing technology. This study aims to evaluate the suitability of Expanded Polyamide – Glass Fiber (EPA-GF) as a kidney stone phantom material embedded within a kidney phantom, based on parameters such as material density, CT number, electron density, and radiation dose across various CT scan exposure voltages. The phantom samples were printed using a dual-extruder 3D printer, with Expanded Polycarbonate (EPC) used as the kidney phantom material. CT scan exposure voltages were set to 80 kV, 100 kV, and 120 kV. Kidney stone sizes used in this study ranged from 1 mm to 8 mm (1 mm, 2 mm, 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, and 8 mm). The measured density of EPA-GF was 1.51 ± 0.06 g/cm³. The CT numbers obtained at each voltage were 373.30 HU, 329.05 HU, and 299.46 HU, respectively. The corresponding electron density values were 1.231, 1.210, and 1.196, respectively. The effective doses measured at each voltage were 0.0240 mSv, 0.0448 mSv, and 0.0798 mSv. All parameter values were found to be closely aligned with literature references. The smallest visible kidney stone size detected was 2 mm.
- Open Access
- 24 June 2025
- Published by Lembaga Penelitian dan Pengabdian Masyarakat Universitas Jambi in Jurnal Ilmiah Ilmu Terapan Universitas Jambi
- Vol. 9  (3) , 924-940
STUDY OF 3D PRINTING HIPS BREAST PHANTOM MATERIAL: EFFECT OF EXPOSURE VOLTAGE VARIATION AND NODULE SIZE
A study has examined the characteristics of 3D printer materials of HIPS and PLA. The study began by printing HIPS materials that resembled breast organs and PLA materials that resembled breast cancer nodules. Then it exposed them using a CT scan with voltage variations of 80 kV, 100 kV, and 120 kV. The parameters studied were compared with the reference breast organ. The results obtained at these voltages obtained CT-number values sequentially (-85.14+0.25) ; (-64.79+0.21) HU; (-55.08+0.18) HU values from the reference 35 to -94 HU, relative electron density values sequentially 0.915; 0.935; 0.945 with a reference value of 0.950, the density value of the material obtained is (0.921+0.002) g/, The EDG value is 3.24 x from ICRU 1989 was 3.33 x, The EDV value is (3.00 + 0.01) x from ICRU report 44 was 3.18 x 10, the value is 3.50 the value of ICRU data is 3.28, and the effective dose values are respectively 2.53 mSv, 2.83 mSv, 3.20 mSv. Based on these characteristics, the results indicate that the breast phantom matches the characteristics of the breast organ, allowing it to be used to predict the presence of breast cancer, as it shares the same characteristics. The results of exposure to the lung cancer nodule phantom on the CT-Scan image of the 2 mm nodule size are not visible. The results of this study can be used as a consideration for radiologists when choosing a voltage based on the predicted size of the breast cancer nodule.
- 24 June 2025
- Published by Lembaga Penelitian dan Pengabdian Masyarakat Universitas Jambi in Jurnal Ilmiah Ilmu Terapan Universitas Jambi
- Vol. 9  (3) , 924-940
Open AccessSTUDY OF 3D PRINTING HIPS BREAST PHANTOM MATERIAL: EFFECT OF EXPOSURE VOLTAGE VARIATION AND NODULE SIZE
A study has examined the characteristics of 3D printer materials of HIPS and PLA. The study began by printing HIPS materials that resembled breast organs and PLA materials that resembled breast cancer nodules. Then it exposed them using a CT scan with voltage variations of 80 kV, 100 kV, and 120 kV. The parameters studied were compared with the reference breast organ. The results obtained at these voltages obtained CT-number values sequentially (-85.14+0.25) ; (-64.79+0.21) HU; (-55.08+0.18) HU values from the reference 35 to -94 HU, relative electron density values sequentially 0.915; 0.935; 0.945 with a reference value of 0.950, the density value of the material obtained is (0.921+0.002) g/, The EDG value is 3.24 x from ICRU 1989 was 3.33 x, The EDV value is (3.00 + 0.01) x from ICRU report 44 was 3.18 x 10, the value is 3.50 the value of ICRU data is 3.28, and the effective dose values are respectively 2.53 mSv, 2.83 mSv, 3.20 mSv. Based on these characteristics, the results indicate that the breast phantom matches the characteristics of the breast organ, allowing it to be used to predict the presence of breast cancer, as it shares the same characteristics. The results of exposure to the lung cancer nodule phantom on the CT-Scan image of the 2 mm nodule size are not visible. The results of this study can be used as a consideration for radiologists when choosing a voltage based on the predicted size of the breast cancer nodule.
- Open Access
- 4 May 2025
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 15  (1) , 133-146
Lung Cancer Classification using Gray-Level Co-Occurrence Matrix Feature Extraction and Forward Selection Feature Selection based on the K-Nearest Neighbor Algorithm
In diagnosing lung cancer, the medical imaging team manually identifies CT-scan images of the lungs. This identification process makes it difficult for the medical imaging team to differentiate between lung cancer and normal images. This is because there is noise in the image, which reduces the image quality, so image processing must reduce the noise. This study used median and Gaussian filters, Otsu thresholding segmentation, GLCM feature extraction, forward selection, and k-nearest Neighbor classification. The research results show that of the 22 statistical features extracted, only 16 were selected for characterizing image classification. The image datasets used are 900 image data sets for program training and 100 image data sets for program testing. With a dataset of 100 image data sets, the level of diagnostic accuracy without forward selection (22 GLCM features) was 81.67%, while the diagnostic accuracy using forward selection (16 GLCM features) was 93.22% with a sensitivity of 92.25% and specificity is 94.46%.
- 4 May 2025
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 15  (1) , 133-146
Open AccessLung Cancer Classification using Gray-Level Co-Occurrence Matrix Feature Extraction and Forward Selection Feature Selection based on the K-Nearest Neighbor Algorithm
In diagnosing lung cancer, the medical imaging team manually identifies CT-scan images of the lungs. This identification process makes it difficult for the medical imaging team to differentiate between lung cancer and normal images. This is because there is noise in the image, which reduces the image quality, so image processing must reduce the noise. This study used median and Gaussian filters, Otsu thresholding segmentation, GLCM feature extraction, forward selection, and k-nearest Neighbor classification. The research results show that of the 22 statistical features extracted, only 16 were selected for characterizing image classification. The image datasets used are 900 image data sets for program training and 100 image data sets for program testing. With a dataset of 100 image data sets, the level of diagnostic accuracy without forward selection (22 GLCM features) was 81.67%, while the diagnostic accuracy using forward selection (16 GLCM features) was 93.22% with a sensitivity of 92.25% and specificity is 94.46%.
- Open Access
- 1 April 2025
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 15  (1) , 246-259
Analysis of ASA and Wood Characteristics with Variations in Thickness and Infill Density as 3D Printing Phantom Radiology Material
This research was conducted to identify wood filaments and ASA as potential organ phantoms based on material density, CT number, electron density, effective atomic number, and radiation dose parameters. The thickness and density of the samples were varied to determine the effect on each parameter. The sample image was obtained from a CTScan radiology test with the same exposure factor. The potential of samples as organ phantoms varies for each parameter. In wood filament samples, a thickness of 1 cm to 2 cm with a density of 20% can potentially be a lung organ phantom. Meanwhile, at a thickness of 5 cm with a density of 100%, it can potentially act as a phantom for bone, liver and muscle organs. In ASA filament samples with a thickness of 1 cm to 5 cm with a low density of 20%, it has the potential to be a lung organ phantom and at a density of 100% it has the potential to be an adipose tissue phantom.
- 1 April 2025
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 15  (1) , 246-259
Open AccessAnalysis of ASA and Wood Characteristics with Variations in Thickness and Infill Density as 3D Printing Phantom Radiology Material
This research was conducted to identify wood filaments and ASA as potential organ phantoms based on material density, CT number, electron density, effective atomic number, and radiation dose parameters. The thickness and density of the samples were varied to determine the effect on each parameter. The sample image was obtained from a CTScan radiology test with the same exposure factor. The potential of samples as organ phantoms varies for each parameter. In wood filament samples, a thickness of 1 cm to 2 cm with a density of 20% can potentially be a lung organ phantom. Meanwhile, at a thickness of 5 cm with a density of 100%, it can potentially act as a phantom for bone, liver and muscle organs. In ASA filament samples with a thickness of 1 cm to 5 cm with a low density of 20%, it has the potential to be a lung organ phantom and at a density of 100% it has the potential to be an adipose tissue phantom.
- Open Access
- 29 December 2024
- Published by Institute of Postgraduate Studies, Syiah Kuala University in Aceh International Journal of Science and Technology
- Vol. 13  (2) , 103-113
Analysis of The Effect of Changes in Thickness and Infill Density of Thermoplastic Polyurethane and Polyethylene Terephthalate Glycol Materials as a Radiological Phantom
Phantoms are used to research image quality and the amount of attenuation as an organ simulation. If done in the human body, it would be hazardous. High radiation exposure can damage cells. Therefore, the phantom is made to resemble the properties and characteristics of a tissue so that the absorbed dose value can be analyzed according to the tissue in the organ. One use of 3D printing technology is in making phantoms. Radiology phantoms must have the same characteristics as human body tissue. This research varies the thickness and infill density of the phantom to get the suitable phantom based on material density, CT number, electron density, and effective dose. The materials used are Thermoplastic Polyurethane (TPU) and Polyethylene Terephthalate Glycol (PETG) with thickness variations of 1 cm, 2 cm, 3 cm, 4 cm, and 5 cm, and infill density variations of 20%, 40%, 60%, 80% and 100 %. Based on the test parameters carried out, it was found that changes in thickness did not affect the material density, EDG, EDV, and Z eff of the sample. However, changes in thickness are proportional to the CT number and electron density values. Meanwhile, changes in infill density are proportional to changes in material density values, CT number, electron density, and EDV. However, changes in infill density do not affect the EDG and Z eff values. The values obtained for each parameter are compared with the reference organ. Samples made from TPU and PETG are suitable for lung, muscle, soft tissue, and spongy bone.
- 29 December 2024
- Published by Institute of Postgraduate Studies, Syiah Kuala University in Aceh International Journal of Science and Technology
- Vol. 13  (2) , 103-113
Open AccessAnalysis of The Effect of Changes in Thickness and Infill Density of Thermoplastic Polyurethane and Polyethylene Terephthalate Glycol Materials as a Radiological Phantom
Phantoms are used to research image quality and the amount of attenuation as an organ simulation. If done in the human body, it would be hazardous. High radiation exposure can damage cells. Therefore, the phantom is made to resemble the properties and characteristics of a tissue so that the absorbed dose value can be analyzed according to the tissue in the organ. One use of 3D printing technology is in making phantoms. Radiology phantoms must have the same characteristics as human body tissue. This research varies the thickness and infill density of the phantom to get the suitable phantom based on material density, CT number, electron density, and effective dose. The materials used are Thermoplastic Polyurethane (TPU) and Polyethylene Terephthalate Glycol (PETG) with thickness variations of 1 cm, 2 cm, 3 cm, 4 cm, and 5 cm, and infill density variations of 20%, 40%, 60%, 80% and 100 %. Based on the test parameters carried out, it was found that changes in thickness did not affect the material density, EDG, EDV, and Z eff of the sample. However, changes in thickness are proportional to the CT number and electron density values. Meanwhile, changes in infill density are proportional to changes in material density values, CT number, electron density, and EDV. However, changes in infill density do not affect the EDG and Z eff values. The values obtained for each parameter are compared with the reference organ. Samples made from TPU and PETG are suitable for lung, muscle, soft tissue, and spongy bone.
- Open Access
- 1 November 2024
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 14  (2) , 339-352
Using Decision Tree With First and Second-Order Statistical Feature Extraction for Classification of Lung Cancer
The classification of CT-Scan images on images with lung cancer and normal lung has been done by improving the image quality of the median and Gabor filters, extraction of first and second-order statistical features, and decision tree classification. The data used comes from LIDC-IDRI as much as 100 training data and 40 test data. The median filter removes noise without removing edges in the image. A Gabor filter is used to facilitate texture analysis on the image. At the feature extraction stage, statistical variations of the first order, second order statistics and the merging of first and second-order statistics. The best results obtained at the testing stage are program designs with variations of feature extraction combining first and second-order statistics. The level of accuracy obtained is 97.5%, with a sensitivity of 100% and a specificity of 95%.
- 1 November 2024
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 14  (2) , 339-352
Open AccessUsing Decision Tree With First and Second-Order Statistical Feature Extraction for Classification of Lung Cancer
The classification of CT-Scan images on images with lung cancer and normal lung has been done by improving the image quality of the median and Gabor filters, extraction of first and second-order statistical features, and decision tree classification. The data used comes from LIDC-IDRI as much as 100 training data and 40 test data. The median filter removes noise without removing edges in the image. A Gabor filter is used to facilitate texture analysis on the image. At the feature extraction stage, statistical variations of the first order, second order statistics and the merging of first and second-order statistics. The best results obtained at the testing stage are program designs with variations of feature extraction combining first and second-order statistics. The level of accuracy obtained is 97.5%, with a sensitivity of 100% and a specificity of 95%.
- Open Access
- 2 May 2024
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 14  (1) , 52-62
Lung Cancer Detection Using a Modified Convolutional Neural Network (CNN)
Image processing is used to classify lung images with malignant or normal nodules. The Convolutional Neural Network (CNN) method is often used to classify images. This study uses a modified CNN architecture with various layers, filters, batch size, dropout, and epoch values. Variations were made to determine the best accuracy value and reduce the overfitting value of the proposed CNN architecture. This study implements the method using the Keras library with the Python programming language. The data is in the form of CT-Scan images of lung cancer and normal lungs. The results of several experiments from the proposed model produce an accuracy value of 95% using three layers, 128 filters on the first layer, 256 on the second layer, and 512 filters on the third layer, then with 32 batch sizes, 0.5 dropout.
- 2 May 2024
- Published by UNS Solo in INDONESIAN JOURNAL OF APPLIED PHYSICS
- Vol. 14  (1) , 52-62
Open AccessLung Cancer Detection Using a Modified Convolutional Neural Network (CNN)
Image processing is used to classify lung images with malignant or normal nodules. The Convolutional Neural Network (CNN) method is often used to classify images. This study uses a modified CNN architecture with various layers, filters, batch size, dropout, and epoch values. Variations were made to determine the best accuracy value and reduce the overfitting value of the proposed CNN architecture. This study implements the method using the Keras library with the Python programming language. The data is in the form of CT-Scan images of lung cancer and normal lungs. The results of several experiments from the proposed model produce an accuracy value of 95% using three layers, 128 filters on the first layer, 256 on the second layer, and 512 filters on the third layer, then with 32 batch sizes, 0.5 dropout.
- Open Access
- 15 March 2024
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 20  (05) , 78-100
Advancing Non-Cuff Hypertension Detection: Leveraging 1D Convolutional Neural Network and Time Domain Physiological Signals
Timely identification of hypertension (HT) is crucial for effectively managing and reducing the potential health consequences, including cardiovascular events such as heart attacks and strokes, as well as the development of kidney disease. Traditional cuff-based devices often discourage regular monitoring because they cause discomfort. Furthermore, the lack of symptoms in HT complicates the early detection of this condition. To address these challenges, our study employs a non-cuff methodology that utilizes unprocessed electrocardiogram (ECG) and photoplethysmogram (PPG) signals. We utilize a customized approach to enhance the features of a one-dimensional convolutional neural network (CNN) specifically tailored to optimize timeseries data. In contrast to previous research, our methodology avoids the need for complex signal extraction or transformation techniques. The main goal is to identify the optimal input signals and fine-tune the critical hyperparameters of CNNs. The clinical data underwent analysis, which revealed that the use of an integrated ECG and PPG approach resulted in the highest level of accuracy for detection. Notably, the F1 score achieved an impressive value of 98.88%. When evaluated separately, ECG outperformed PPG. Our study contributes to the advancement of the field by introducing a new approach that combines comfort and high accuracy in the early detection of HT. This method is practical and ensures a patient-friendly experience.
- 15 March 2024
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 20  (05) , 78-100
Open AccessAdvancing Non-Cuff Hypertension Detection: Leveraging 1D Convolutional Neural Network and Time Domain Physiological Signals
Timely identification of hypertension (HT) is crucial for effectively managing and reducing the potential health consequences, including cardiovascular events such as heart attacks and strokes, as well as the development of kidney disease. Traditional cuff-based devices often discourage regular monitoring because they cause discomfort. Furthermore, the lack of symptoms in HT complicates the early detection of this condition. To address these challenges, our study employs a non-cuff methodology that utilizes unprocessed electrocardiogram (ECG) and photoplethysmogram (PPG) signals. We utilize a customized approach to enhance the features of a one-dimensional convolutional neural network (CNN) specifically tailored to optimize timeseries data. In contrast to previous research, our methodology avoids the need for complex signal extraction or transformation techniques. The main goal is to identify the optimal input signals and fine-tune the critical hyperparameters of CNNs. The clinical data underwent analysis, which revealed that the use of an integrated ECG and PPG approach resulted in the highest level of accuracy for detection. Notably, the F1 score achieved an impressive value of 98.88%. When evaluated separately, ECG outperformed PPG. Our study contributes to the advancement of the field by introducing a new approach that combines comfort and high accuracy in the early detection of HT. This method is practical and ensures a patient-friendly experience.