Olof Svensson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Olof Svensson has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Gordon A. Leonard
European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France
7 shared publications - Fabien Dobias
European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France
5 shared publications - Thierry Giraud
European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France
5 shared publications - Alexander N. Popov
European Synchrotron Radiation Facility, Grenoble, France
4 shared publications - Antonia Beteva
European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France
4 shared publications - David Flot
European Synchrotron Radiation Facility (ESRF), Grenoble, France
4 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 82 (8) , 915-939
An unattended image-processing pipeline for on-the-fly quality assessment and 3D exploration in cryo-EM
Single-particle analysis (SPA) by cryogenic electron microscopy (cryo-EM) has become a cornerstone of structural biology; yet, the workflow from data acquisition to a 3D structure remains a time-consuming, manual and significant task. Researchers often invest days of valuable microscope time collecting massive datasets with little to no real-time feedback on sample quality or the ultimate feasibility of achieving a high-resolution reconstruction. To address this challenge, we have developed an automated, end-to-end processing workflow designed for on-the-fly analysis. Built within the Scipion framework, the pipeline integrates a cascade of automated quality-control filters, a novel consensus-based strategy for training a data-specific particle-picking model, and a parallel 2D/3D validation scheme to ensure robust processing outcomes. We validated the workflow on a diverse benchmark of 32 datasets (CryoPPP), achieving a 94% overall processing success rate and obtaining high-quality 3D reconstructions in 78% of cases. Real-world deployment at the European Synchrotron (ESRF) cryo-EM facility further validated its practical utility: the pipeline demonstrated processing speeds exceeding data acquisition, delivering preliminary 3D maps in under 3 h. Approximately 70% of user experiments converged to interpretable structures, with half achieving 3–4 Å resolution, despite the inherent complexity of facility-collected samples. By providing researchers with rapid, actionable feedback and identifying both promising and problematic datasets in real time, this workflow transforms cryo-EM data collection from a passive process into an active, data-driven experiment. It serves as a powerful diagnostic and decision-support tool, accelerating structural determination and optimizing microscope time in high-throughput cryo-EM environments.
- 28 July 2026
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 82 (8) , 915-939
Open AccessAn unattended image-processing pipeline for on-the-fly quality assessment and 3D exploration in cryo-EM
Single-particle analysis (SPA) by cryogenic electron microscopy (cryo-EM) has become a cornerstone of structural biology; yet, the workflow from data acquisition to a 3D structure remains a time-consuming, manual and significant task. Researchers often invest days of valuable microscope time collecting massive datasets with little to no real-time feedback on sample quality or the ultimate feasibility of achieving a high-resolution reconstruction. To address this challenge, we have developed an automated, end-to-end processing workflow designed for on-the-fly analysis. Built within the Scipion framework, the pipeline integrates a cascade of automated quality-control filters, a novel consensus-based strategy for training a data-specific particle-picking model, and a parallel 2D/3D validation scheme to ensure robust processing outcomes. We validated the workflow on a diverse benchmark of 32 datasets (CryoPPP), achieving a 94% overall processing success rate and obtaining high-quality 3D reconstructions in 78% of cases. Real-world deployment at the European Synchrotron (ESRF) cryo-EM facility further validated its practical utility: the pipeline demonstrated processing speeds exceeding data acquisition, delivering preliminary 3D maps in under 3 h. Approximately 70% of user experiments converged to interpretable structures, with half achieving 3–4 Å resolution, despite the inherent complexity of facility-collected samples. By providing researchers with rapid, actionable feedback and identifying both promising and problematic datasets in real time, this workflow transforms cryo-EM data collection from a passive process into an active, data-driven experiment. It serves as a powerful diagnostic and decision-support tool, accelerating structural determination and optimizing microscope time in high-throughput cryo-EM environments.
- Open Access
- 26 June 2025
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 81 (7) , 344-356
Enhanced capabilities for multi-crystal data collection based on double mesh scans
Two-dimensional X-ray mesh (raster) scans are broadly used in macromolecular crystallography to identify positions on the sample holder at which diffraction images can be collected. Based on a single mesh scan, the commonly known method Mesh&Collect allows the collection of small angular wedges of diffraction data from multiple crystals identified in the mesh-scan area. Recently, the capabilities of the method have been extended by using two mesh scans instead of one. The scans are usually performed at orthogonal orientations of the rotation axis, or any other angular difference less than 90° can be used. This allows the more accurate determination, when compared with a single mesh scan, of the 3D centre positions of each crystal contained in the scanned area and gives better estimates of their dimensions and diffraction qualities. We present the upgraded DoubleMesh&Collect method based on the Dozor, Dozor-m2 and Resheteau software programs which automatically analyse the diffraction images of the two mesh scans. The applicability of the method is demonstrated on several cases, including room-temperature diffraction studies. The problem of cartography of large crystals is discussed.
- 26 June 2025
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 81 (7) , 344-356
Open AccessEnhanced capabilities for multi-crystal data collection based on double mesh scans
Two-dimensional X-ray mesh (raster) scans are broadly used in macromolecular crystallography to identify positions on the sample holder at which diffraction images can be collected. Based on a single mesh scan, the commonly known method Mesh&Collect allows the collection of small angular wedges of diffraction data from multiple crystals identified in the mesh-scan area. Recently, the capabilities of the method have been extended by using two mesh scans instead of one. The scans are usually performed at orthogonal orientations of the rotation axis, or any other angular difference less than 90° can be used. This allows the more accurate determination, when compared with a single mesh scan, of the 3D centre positions of each crystal contained in the scanned area and gives better estimates of their dimensions and diffraction qualities. We present the upgraded DoubleMesh&Collect method based on the Dozor, Dozor-m2 and Resheteau software programs which automatically analyse the diffraction images of the two mesh scans. The applicability of the method is demonstrated on several cases, including room-temperature diffraction studies. The problem of cartography of large crystals is discussed.
- Open Access
- 1 November 2024
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 37 (6) , 9-15
EWOKS: An Extensible WOrKflow System
- 1 November 2024
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 37 (6) , 9-15
Open AccessEWOKS: An Extensible WOrKflow System
- Open Access
- 1 November 2024
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 37 (6) , 35-42
DRAC – Data Repository for Advancing Open sCience
- 1 November 2024
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 37 (6) , 35-42
Open AccessDRAC – Data Repository for Advancing Open sCience
- Open Access
- 14 March 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 928-929
ID23-2: an automated and high-performance microfocus beamline for macromolecular crystallography at the ESRF. Corrigendum
A revised version of Table 2 of Nanao et al. [J. Synchrotron Rad. (2022). 29, 581–590] is provided.
- 14 March 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 928-929
Open AccessID23-2: an automated and high-performance microfocus beamline for macromolecular crystallography at the ESRF. Corrigendum
A revised version of Table 2 of Nanao et al. [J. Synchrotron Rad. (2022). 29, 581–590] is provided.
- Open Access
- 22 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 581-590
ID23-2: an automated and high-performance microfocus beamline for macromolecular crystallography at the ESRF
ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s−1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.
- 22 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 581-590
Open AccessID23-2: an automated and high-performance microfocus beamline for macromolecular crystallography at the ESRF
ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s−1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.
- Open Access
- 29 April 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 844-851
ID30A-3 (MASSIF-3) – a beamline for macromolecular crystallography at the ESRF with a small intense beam
ID30A-3 (or MASSIF-3) is a mini-focus (beam size 18 µm × 14 µm) highly intense (2.0 × 1013 photons s−1), fixed-energy (12.81 keV) beamline for macromolecular crystallography (MX) experiments at the European Synchrotron Radiation Facility (ESRF). MASSIF-3 is one of two fixed-energy beamlines sited on the first branch of the canted undulator setup on the ESRF ID30 port and is equipped with a MD2 micro-diffractometer, a Flex HCD sample changer, and an Eiger X 4M fast hybrid photon-counting detector. MASSIF-3 is recommended for collecting diffraction data from single small crystals (≤15 µm in one dimension) or for experiments using serial methods. The end-station has been in full user operation since December 2014, and here its current characteristics and capabilities are described.
- 29 April 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 844-851
Open AccessID30A-3 (MASSIF-3) – a beamline for macromolecular crystallography at the ESRF with a small intense beam
ID30A-3 (or MASSIF-3) is a mini-focus (beam size 18 µm × 14 µm) highly intense (2.0 × 1013 photons s−1), fixed-energy (12.81 keV) beamline for macromolecular crystallography (MX) experiments at the European Synchrotron Radiation Facility (ESRF). MASSIF-3 is one of two fixed-energy beamlines sited on the first branch of the canted undulator setup on the ESRF ID30 port and is equipped with a MD2 micro-diffractometer, a Flex HCD sample changer, and an Eiger X 4M fast hybrid photon-counting detector. MASSIF-3 is recommended for collecting diffraction data from single small crystals (≤15 µm in one dimension) or for experiments using serial methods. The end-station has been in full user operation since December 2014, and here its current characteristics and capabilities are described.
- Open Access
- 10 July 2019
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 6 (5) , 822-831
A comparative anatomy of protein crystals: lessons from the automatic processing of 56 000 samples
The fully automatic processing of crystals of macromolecules has presented a unique opportunity to gather information on the samples that is not usually recorded. This has proved invaluable in improving sample-location, characterization and data-collection algorithms. After operating for four years, MASSIF-1 has now processed over 56 000 samples, gathering information at each stage, from the volume of the crystal to the unit-cell dimensions, the space group, the quality of the data collected and the reasoning behind the decisions made in data collection. This provides an unprecedented opportunity to analyse these data together, providing a detailed landscape of macromolecular crystals, intimate details of their contents and, importantly, how the two are related. The data show that mosaic spread is unrelated to the size or shape of crystals and demonstrate experimentally that diffraction intensities scale in proportion to crystal volume and molecular weight. It is also shown that crystal volume scales inversely with molecular weight. The results set the scene for the development of X-ray crystallography in a changing environment for structural biology.
- 10 July 2019
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 6 (5) , 822-831
Open AccessA comparative anatomy of protein crystals: lessons from the automatic processing of 56 000 samples
The fully automatic processing of crystals of macromolecules has presented a unique opportunity to gather information on the samples that is not usually recorded. This has proved invaluable in improving sample-location, characterization and data-collection algorithms. After operating for four years, MASSIF-1 has now processed over 56 000 samples, gathering information at each stage, from the volume of the crystal to the unit-cell dimensions, the space group, the quality of the data collected and the reasoning behind the decisions made in data collection. This provides an unprecedented opportunity to analyse these data together, providing a detailed landscape of macromolecular crystals, intimate details of their contents and, importantly, how the two are related. The data show that mosaic spread is unrelated to the size or shape of crystals and demonstrate experimentally that diffraction intensities scale in proportion to crystal volume and molecular weight. It is also shown that crystal volume scales inversely with molecular weight. The results set the scene for the development of X-ray crystallography in a changing environment for structural biology.
- Open Access
- 28 May 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 75 (6) , 528-535
CM01: a facility for cryo-electron microscopy at the European Synchrotron
Recent improvements in direct electron detectors, microscope technology and software provided the stimulus for a `quantum leap' in the application of cryo-electron microscopy in structural biology, and many national and international centres have since been created in order to exploit this. Here, a new facility for cryo-electron microscopy focused on single-particle reconstruction of biological macromolecules that has been commissioned at the European Synchrotron Radiation Facility (ESRF) is presented. The facility is operated by a consortium of institutes co-located on the European Photon and Neutron Campus and is managed in a similar fashion to a synchrotron X-ray beamline. It has been open to the ESRF structural biology user community since November 2017 and will remain open during the 2019 ESRF–EBS shutdown.
- 28 May 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 75 (6) , 528-535
Open AccessCM01: a facility for cryo-electron microscopy at the European Synchrotron
Recent improvements in direct electron detectors, microscope technology and software provided the stimulus for a `quantum leap' in the application of cryo-electron microscopy in structural biology, and many national and international centres have since been created in order to exploit this. Here, a new facility for cryo-electron microscopy focused on single-particle reconstruction of biological macromolecules that has been commissioned at the European Synchrotron Radiation Facility (ESRF) is presented. The facility is operated by a consortium of institutes co-located on the European Photon and Neutron Campus and is managed in a similar fashion to a synchrotron X-ray beamline. It has been open to the ESRF structural biology user community since November 2017 and will remain open during the 2019 ESRF–EBS shutdown.
- Open Access
A comparative anatomy of protein crystals: lessons from the automatic processing of 56,000 samples
Synopsis: The automatic processing of over 56,000 crystals by the autonomous ESRF beamline MASSIF-1 has provided a data set of crystal characteristics and properties that allows many theoretical proposals and assumptions to be evaluated experimentally. The fully automatic processing of crystals of macromolecules has presented a unique opportunity to gather information on the samples that is not usually recorded. This has proved invaluable in improving the sample location, characterisation and data collection algorithms. After operating for four years, MASSIF-1 has now processed over 56,000 samples, gathering information at each stage, from the volume of the crystal to the unit cell dimensions, space group, quality of the data collected and the reasoning behind the decisions made in data collection. This provides an unprecedented opportunity to analyse these data together, providing a detailed landscape of macromolecular crystals and intimate details of their contents and, importantly, how the two are related. The data show that mosaic spread is unrelated to the size or shape of crystals and demonstrate experimentally that diffraction intensities scale in proportion to crystal volume and molecular weight. It is also shown that crystal volume scales inversely with molecular weight. The results set the scene for the development of X-ray crystallography in a changing environment for structural biology.
Open AccessA comparative anatomy of protein crystals: lessons from the automatic processing of 56,000 samples
Synopsis: The automatic processing of over 56,000 crystals by the autonomous ESRF beamline MASSIF-1 has provided a data set of crystal characteristics and properties that allows many theoretical proposals and assumptions to be evaluated experimentally. The fully automatic processing of crystals of macromolecules has presented a unique opportunity to gather information on the samples that is not usually recorded. This has proved invaluable in improving the sample location, characterisation and data collection algorithms. After operating for four years, MASSIF-1 has now processed over 56,000 samples, gathering information at each stage, from the volume of the crystal to the unit cell dimensions, space group, quality of the data collected and the reasoning behind the decisions made in data collection. This provides an unprecedented opportunity to analyse these data together, providing a detailed landscape of macromolecular crystals and intimate details of their contents and, importantly, how the two are related. The data show that mosaic spread is unrelated to the size or shape of crystals and demonstrate experimentally that diffraction intensities scale in proportion to crystal volume and molecular weight. It is also shown that crystal volume scales inversely with molecular weight. The results set the scene for the development of X-ray crystallography in a changing environment for structural biology.