SMSamuel Masket

Samuel Masket

*This is an algorithmically generated author record based on publicly available information.

Samuel Masket has a total of 423 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Clinical and refractive outcomes of secondary intraocular lens fixation using small-incision scleral suture fixation vs intrascleral haptic fixation

    by Mahsaw Mansoor, Alice Jiang, Stephen Kwong, Hasan Alsetri, Samuel Masket, Nicole Fram

    Purpose: To compare clinical and refractive outcomes of small-incision scleral suture fixation (SSF) vs intrascleral haptic fixation (ISHF) for secondary intraocular lens (IOL) implantation in adults. Setting: Single outpatient ophthalmology clinic. Design: Retrospective, single-center cohort study. Methods: Eyes undergoing small-incision SSF or ISHF between 2019 and 2024 were identified. Demographics, surgical indications, IOL types, refractive accuracy, and postoperative complications were analyzed. Refractive outcomes were evaluated using spherical equivalent refractive accuracy (SERA) and absolute SERA (ASERA). Results: 132 eyes from 125 adult patients were included. 56 eyes underwent SSF, and 76 underwent ISHF. Indications included subluxated IOL (58%), dislocated IOL (17%), aphakia (20%), and uveitis–glaucoma–hyphema syndrome (5%). In the SSF group, MX60E or ET IOLs predominated, while CT Lucia 602 was most common in ISHF. Mean SERA was −0.45 diopters (D) for SSF and −0.36 D for ISHF ( P = .48); mean ASERA was 0.52 D and 0.54 D, respectively ( P = .96). At postoperative month 3, 70% of SSF vs 62% of ISHF eyes were within ±0.50 D of target and 85% vs 86% were within ±1.00 D. Complication rates were low and comparable, with trends toward higher early hypotony in SSF and more reoperations in ISHF. Conclusions: Both small-incision SSF and ISHF are safe and effective for secondary IOL implantation in adults. Refractive outcomes were comparable, with SSF demonstrating slightly greater predictability and fewer reoperations, while ISHF was associated with less early hypotony. Technique selection should be guided by surgeon experience, IOL choice, and patient-specific factors.

  • Clinical Features, Phenotypic Spectrum, and Associated Factors in Histopathologically Confirmed Dead Bag Syndrome

    by Mahsaw Mansoor, Stephen Kwong, Hasan Alsetri, Nick Mamalis, Liliana Werner, Samuel Masket, Nicole Fram

    Purpose: To characterize the demographic, ocular, systemic, and histopathologic features of patients undergoing surgery for late intraocular lens (IOL) instability with clinically suspected dead bag syndrome (DBS). Setting: Private ophthalmology practice and tertiary ophthalmic pathology laboratory. Design: Single-center consecutive case series with prospective tissue collection and retrospective chart review. Methods: Capsular bag remnants were explanted during secondary IOL surgery and submitted for histopathologic examination. Demographic, ocular, and systemic characteristics were obtained from the medical record. Lens epithelial cell (LEC) status was graded as 0 = absent; 1 = rare residual LECs; 2 = focal identifiable LEC segments. Specimens were assessed for capsular splitting/schisis, cortical material, and anterior capsular fibrous metaplasia. Exploratory clinical comparisons were performed between LEC grade 0 and LEC grade 1-2 subgroups. Results: Thirty-one eyes from 26 patients underwent secondary IOL surgery for late IOL subluxation or dislocation with clinical suspicion of DBS, including 27 with histopathologic evaluation. Mean age at secondary surgery was 70.5 ± 10.5 years and 80.7% patients were male. Median time from cataract surgery to presentation was 13.0 years (IQR 9.0-16.5). Axial myopia was present in 6/31 eyes (19.4%). Atopy was documented in 9/31 (29.0%), prior radiation or chemotherapy exposure in 8/31 (25.8%), autoimmune disease in 10/31 (32.3%), and ACE inhibitor or ARB use in 14/31 (45.2%). Complete LEC absence (grade 0) was present in 8/27 (29.6%), while 19/27 (70.4%) demonstrated residual LECs and/or cortical material (grades 1-2). Spontaneous posterior capsular rupture was documented in 15/31 (48.4%) cases and in 15/27 (55.6%) histopathology-confirmed cases. Atopy was more frequent in LEC grade 0 than among LEC grade 1-2 eyes (37.5% vs 15.8%; P = 0.32), though this did not reach statistical significance. Conclusions: DBS represents a histopathologically definable spectrum of capsular degeneration characterized by LEC depletion and capsular splitting with structural failure leading to late IOL instability. Nearly half of confirmed cases presented without clinically evident spontaneous posterior capsular rupture, suggesting that rupture is not required for DBS diagnosis.

  • Reduced incidence of negative dysphotopsia with scleral-fixated intraocular lenses

    by Samuel Masket, Nicole Fram, Stephen Kwong, Don Pham, Mahsaw Mansoor, Sophie Kantor, Vanessa Reyes, Hasan Alsetri

    Purpose: To determine the incidence of negative dysphotopsia (ND) in eyes with scleral-fixated intraocular lenses (SFIOLs) absent the capsular bag remnant. Setting: Private ophthalmology practice Design: Retrospective observational study Methods: Consecutive cases of patients undergoing SFIOL without a capsule bag remnant were reviewed. Patients were excluded if they had conditions that could impact visual field testing, iris or pupil abnormalities, best-corrected visual acuity worse than 20/50, or clinically significant corneal pathology. Eligible patients were contacted via email and if they agreed to participate, a telephone interview with a novel questionnaire was completed after the patient reviewed a representative image of an ND scotoma. Results: Of 206 identified scleral-fixated IOL cases, 50 patients met inclusion criteria and agreed to complete the novel questionnaire. None of the 50 patients reported symptoms of ND at any time following surgery. Conclusions: Negative dysphotopsia was not observed in this cohort of SFIOLs without a capsule bag remnant. These findings support the hypothesis that ND occurs primarily with “in-the-bag” IOLs and that the lens capsule, in some fashion, may play a role in the development of ND and suggest that existing optical modeling tests alone may be insufficient to explain the etiology for ND.

  • Surgical outcomes of intraocular lens iris suture fixation in eyes with residual capsule support

    by Hasan Bs Alsetri, Samuel Masket, Nicole Fram, Marisa Schoen, Julieanne Bs Cabang, Jared Bs Pagal, Stephen Bs Kwong, Ashlyn Fram, Hector Bs Sandoval

    Purpose: To evaluate the safety and refractive outcomes of eyes after intraocular lens (IOL) iris suture fixation (ISF). Setting: Private practice, Los Angeles, California. Design: Nonrandomized and unmasked retrospective chart review. Methods: Eyes that underwent IOL exchange or repositioning with ISF with at least 270 degrees of capsular support were included. Eyes with less than 270 degrees of capsular support and eyes with iris damage were excluded. The primary outcome measures included incidence of cystoid macular edema (CME), IOL dislocation requiring refixation, and chronic inflammation. Secondary outcome measures included worsening intraocular pressure (IOP) control, retinal tear or detachment, worsening of corrected distance visual acuity (CDVA), and corneal decompensation. Refractive outcomes for 26 subgrouped eyes included mean and median spherical equivalent refraction accuracy (SERA), and percentage of eyes within 0.5 diopter (D) and 1 D of the refractive target. Results: The study included 53 eyes of 50 patients. CME: 2/53 (3.8%), IOL dislocation requiring refixation: 2/53 (3.8%), chronic inflammation: 1/53 (1.9%), worsening IOP control: 5/53 (9.4%), retinal tear or detachment: 2/53 (3.8%). No patient experienced worsening of CDVA from baseline or corneal decompensation. Mean SERA ± SD −0.35 ± 0.29 D, median SERA −0.37 D. Of the 26 eyes subgrouped for refractive analysis, 73% were within 0.5 D and 100% were within 1 D of the desired refractive outcome. Conclusions: ISF can offer stability for sulcus-fixated IOLs provided there is some residual capsule support. Although there are measurable complications, there is a relatively low side effect profile. The refractive error tended to be myopic, indicating the need for further refinement of IOL power predictive formulas.

  • Clinical outcomes and complications following intraocular lens exchange in the setting of an open or intact posterior capsule

    by Hasan Bs Alsetri, Samuel Masket, Nicole Fram, Hector Bs Sandoval, Julieanne Bs Cabang, Jessie BMed McLachlan

    Purpose: To assess whether there are added risks when performing intraocular lens (IOL) exchange in the setting of an open posterior capsule (OPC) when compared with a closed posterior capsule (CPC) IOL exchange. Setting: Private practice, Los Angeles, California. Design: Nonrandomized and unmasked retrospective chart review. Methods: Eyes undergoing IOL exchange solely to relieve optical symptoms, with open or intact posterior capsules, were included. Eyes undergoing IOL exchange due to IOL malposition or dislocation were excluded. Eyes with preexisting, uncontrolled glaucoma and inflammation and eyes with a visual potential worse than 20/40 (Snellen) were also excluded. The main outcome measures were the postoperative complications compared between the OPC and CPC groups. Results: 90 eyes of 75 patients undergoing IOL exchange were included in this study; 38/90 eyes had an OPC, and 52/90 eyes had a CPC. 3/38 in the OPC group and 2/52 in the CPC group experienced worsening intraocular pressure control. 1/38 in the OPC group experienced chronic inflammation. 2/38 in the OPC group and 2/52 in the CPC group experienced cystoid macular edema. 1/52 in the CPC group experienced a retinal tear. Statistically or clinically significant differences in postoperative complications between the OPC and CPC groups were not found. Conclusions: In the hands of an experienced surgeon, IOL exchange with an OPC appear red to be just as safe as IOL exchange with a CPC; when deemed necessary, experienced surgeons may perform an IOL exchange safely in the presence of an OPC.


  • Open Access

    Cataract surgery update

    by Samuel Masket

  • Open Access

    Surgical Correction for Late Postoperative Subluxation of a Diffractive Optic Multifocal IOL, Capsule Bag and Capsule Tension Ring Complex: Case Report

    by Samuel Masket

    Diffractive optic intraocular lenses (IOLs) require near perfect centration for best performance. A patient with a multifocal IOL and pseudoexfoliation developed late marked subluxation of the capsule bag, capsule tension ring and multifocal IOL complex. The surgical challenge was to fixate and recenter the diffractive optic IOL in order to restore normal quality vision; traditional surgical methods are not adequate for repositioning IOLs of this nature. A unique surgical plan that included three-point radially oriented suture fixation of an existing standard capsule tension ring (CTR) was conceived and was successful in achieving the patient’s goal of maintaining spectacle independence by returning his vision to previous levels with a well-centered multifocal IOL.


  • Results of the United States Food and Drug Administration Clinical Trial of the CustomFlex Artificial Iris

    by Brandon D. Ayres, Barbara S. Fant, Zachary C. Landis, Kevin M. Miller, R. Doyle Stulting, Robert J. Cionni, Nicole R. Fram, Stephen Hamilton, David R. Hardten, Douglas D. Koch, et al.


  • Femtosecond laser–assisted intraocular lens exchange

    by Nicole R. Fram, Samuel Masket, Hasan Alsetri, Don Pham

    Intraocular lens (IOL) exchange in patients with anterior capsule contraction resulting from phimosis can complicate IOL exchange as the fibrotic anterior capsule must be cut to gain access to the IOL. Maintaining curvilinear capsulotomy is particularly important when the desired outcome is bag-to-bag IOL exchange. Similarly, when the posterior capsule is open, properly sized curvilinear anterior capsulotomy will allow for optic capture and further stability of the exchanged IOL. Secondary capsulotomy size ranged from 4.9 to 5.0 mm, and the energy was set at 4 to 10 μJ depending on diffusiveness of the anterior capsule. The femtosecond laser was adapted to create a secondary anterior capsulotomy to facilitate IOL exchange.