Matteo Novara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matteo Novara has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Schanz
Department of Experimental Methods, Institute of Aerodynamics and Flow Technology, German Aerospace Center (DLR), 37073 Göttingen, Germany
9 shared publications Andreas Schröder
Institute of Aerodynamics and Flow Technology
6 shared publicationsReinhard Geisler
German Aerospace Center
6 shared publications- Andreas Kohl
Department Ground Vehicles, Institute of Aerodynamics and Flow Technology, German Aerospace Center (DLR), Göttingen, Germany
5 shared publications Daniel Schanz
Institute of Aerodynamics and Flow Technology
5 shared publicationsJ. Agocs
Department Experimental Methods, Institute of Aerodynamics and Flow Technology, German Aerospace Center (DLR), Göttingen, Germany
5 shared publications
Latest Publications
- Open Access
- 22 July 2023
- Published by Springer Nature in Flow, Turbulence and Combustion
- Vol. 111 (2) , 409-438
Modification of the SSG/LRR-Omega Model for Turbulent Boundary Layer Flows in an Adverse Pressure Gradient
A modification of the RANS turbulence model SSG/LRR- $$\omega $$ for turbulent boundary layers in an adverse pressure gradient is presented. The modification is based on a wall law for the mean velocity, in which the log law is progressively eroded in an adverse pressure gradient and an extended wall law (designated loosely as a half-power law) emerges above the log law. An augmentation term for the half-power law region is derived from the analysis of the boundary-layer equation for the specific rate of dissipation $$\omega $$ . An extended data structure within the RANS solver provides, for each viscous wall point, the field points on a wall-normal line. This enables the evaluation of characteristic boundary layer parameters for the local activation of the augmentation term. The modification is calibrated using a joint DLR/UniBw turbulent boundary layer experiment. The modified model yields an improved predictive accuracy for flow separation. Finally, the applicability of the modified model to a 3D wing-body configuration is demonstrated.- 22 July 2023
- Published by Springer Nature in Flow, Turbulence and Combustion
- Vol. 111 (2) , 409-438
Open AccessModification of the SSG/LRR-Omega Model for Turbulent Boundary Layer Flows in an Adverse Pressure Gradient
A modification of the RANS turbulence model SSG/LRR- $$\omega $$ for turbulent boundary layers in an adverse pressure gradient is presented. The modification is based on a wall law for the mean velocity, in which the log law is progressively eroded in an adverse pressure gradient and an extended wall law (designated loosely as a half-power law) emerges above the log law. An augmentation term for the half-power law region is derived from the analysis of the boundary-layer equation for the specific rate of dissipation $$\omega $$ . An extended data structure within the RANS solver provides, for each viscous wall point, the field points on a wall-normal line. This enables the evaluation of characteristic boundary layer parameters for the local activation of the augmentation term. The modification is calibrated using a joint DLR/UniBw turbulent boundary layer experiment. The modified model yields an improved predictive accuracy for flow separation. Finally, the applicability of the modified model to a 3D wing-body configuration is demonstrated. - Open Access
- 29 April 2023
- Published by Springer Nature in Experiments in Fluids
- Vol. 64 (5) , 1-21
Two-Pulse 3D particle tracking with Shake-The-Box
This study presents an approach to two-pulse 3D particle tracking using methods developed within the Shake-The-Box (STB, Schanz et al. in Exp Fluids 57:70, 2016) Lagrangian particle tracking (LPT) framework. The original STB algorithm requires time-resolved data and reconstructs 3D trajectories using a particle position prediction–correction scheme. However, dual-frame 3D acquisition systems, consisting of a dual-cavity laser and double-frame cameras, remain commonly used for many particle-image-based investigations in a wide range of flow velocities and applications. While such systems can be used to capture short Multi-Pulse particle trajectories (Multi-Pulse STB, MP-STB—Novara et al. in Exp Fluids 57:128, 2016a; Novara et al. in Exp Fluids 60:44, 2019), the most widespread application is still a single-pulse illumination of each of the two available frames. As a consequence, 3D LPT approaches capable of dealing with two-pulse recordings are of high interest for both the scientific community and industry. Several methods based on various evaluation schemes have been developed in the past. In the present study, a Two-Pulse Shake-The-Box approach (TP-STB) is proposed, based on the advanced IPR algorithm presented by Jahn et al. (Exp Fluids 62:179, 2021), in combination with an iterative scheme of reconstruction and tracking, ideally with the help of a predictor gained by Particle Space Correlation. It basically constitutes a lean version of the MP-STB technique, with lower demands on experimental setup and processing time. The performances of TP-STB are assessed by means of comparison with the results from the time-resolved STB algorithm (TR-STB) both concerning synthetic and experimental data. The suitability of the algorithm for the analysis of dual-frame 3D particle imaging datasets is assessed based on the processing of existing images from a tomographic PIV experiment from 2012. The comparison with the results published by Henningsson et al. (J R Soc Interface 12:20150119, 2015) confirms the capability of TP-STB to accurately reconstruct individual particle tracks despite the limited time-resolution information offered by two-frame recordings.
- 29 April 2023
- Published by Springer Nature in Experiments in Fluids
- Vol. 64 (5) , 1-21
Open AccessTwo-Pulse 3D particle tracking with Shake-The-Box
This study presents an approach to two-pulse 3D particle tracking using methods developed within the Shake-The-Box (STB, Schanz et al. in Exp Fluids 57:70, 2016) Lagrangian particle tracking (LPT) framework. The original STB algorithm requires time-resolved data and reconstructs 3D trajectories using a particle position prediction–correction scheme. However, dual-frame 3D acquisition systems, consisting of a dual-cavity laser and double-frame cameras, remain commonly used for many particle-image-based investigations in a wide range of flow velocities and applications. While such systems can be used to capture short Multi-Pulse particle trajectories (Multi-Pulse STB, MP-STB—Novara et al. in Exp Fluids 57:128, 2016a; Novara et al. in Exp Fluids 60:44, 2019), the most widespread application is still a single-pulse illumination of each of the two available frames. As a consequence, 3D LPT approaches capable of dealing with two-pulse recordings are of high interest for both the scientific community and industry. Several methods based on various evaluation schemes have been developed in the past. In the present study, a Two-Pulse Shake-The-Box approach (TP-STB) is proposed, based on the advanced IPR algorithm presented by Jahn et al. (Exp Fluids 62:179, 2021), in combination with an iterative scheme of reconstruction and tracking, ideally with the help of a predictor gained by Particle Space Correlation. It basically constitutes a lean version of the MP-STB technique, with lower demands on experimental setup and processing time. The performances of TP-STB are assessed by means of comparison with the results from the time-resolved STB algorithm (TR-STB) both concerning synthetic and experimental data. The suitability of the algorithm for the analysis of dual-frame 3D particle imaging datasets is assessed based on the processing of existing images from a tomographic PIV experiment from 2012. The comparison with the results published by Henningsson et al. (J R Soc Interface 12:20150119, 2015) confirms the capability of TP-STB to accurately reconstruct individual particle tracks despite the limited time-resolution information offered by two-frame recordings.
- 4 May 2022
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 941, A42
Experimental study of turbulent bubbly jet. Part 1. Simultaneous measurement of three-dimensional velocity fields of bubbles and water
This study proposes a method for simultaneous measurements of time-resolved three-dimensional velocity fields of the dispersed and continuous phases of a turbulent bubbly jet at a low void fraction using Lagrangian particle tracking (LPT) velocimetry with the Shake-The-Box algorithm. Four high-speed cameras are used to acquire time series of images that include both bubbles and fluid tracer particles. Bubbles are firstly tracked using intensity differences between tracer particles and bubbles, then the bubble images are removed from the camera images and all tracer particles are tracked using the residual images. Subsequently, FlowFit interpolation is applied to the LPT results obtained by phase separation to investigate flow characteristics of a bubbly jet. The bubbly jet was divided into two regions along the vertical direction: jet-like and plume-like regions. Streamwise vortex structures of continuous phase were generated mainly by the rising bubbles. The Gaussian and top-hat velocity profiles matched well with the ensemble-averaged fluid and bubble velocities, respectively. The measured slip velocity in the radial direction was not constant but linearly increased. The classical assumption of self-similarity with Gaussian profiles for fluid velocity and bubble concentration is experimentally verified. The fluid volume flux and entrainment coefficient are obtained as a function of the slip velocity, void fraction, plume and bubble width based on three-dimensional measurements. We found that the classical integral theory agrees well with experiments in the plume region.
- 4 May 2022
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 941, A42
Experimental study of turbulent bubbly jet. Part 1. Simultaneous measurement of three-dimensional velocity fields of bubbles and water
This study proposes a method for simultaneous measurements of time-resolved three-dimensional velocity fields of the dispersed and continuous phases of a turbulent bubbly jet at a low void fraction using Lagrangian particle tracking (LPT) velocimetry with the Shake-The-Box algorithm. Four high-speed cameras are used to acquire time series of images that include both bubbles and fluid tracer particles. Bubbles are firstly tracked using intensity differences between tracer particles and bubbles, then the bubble images are removed from the camera images and all tracer particles are tracked using the residual images. Subsequently, FlowFit interpolation is applied to the LPT results obtained by phase separation to investigate flow characteristics of a bubbly jet. The bubbly jet was divided into two regions along the vertical direction: jet-like and plume-like regions. Streamwise vortex structures of continuous phase were generated mainly by the rising bubbles. The Gaussian and top-hat velocity profiles matched well with the ensemble-averaged fluid and bubble velocities, respectively. The measured slip velocity in the radial direction was not constant but linearly increased. The classical assumption of self-similarity with Gaussian profiles for fluid velocity and bubble concentration is experimentally verified. The fluid volume flux and entrainment coefficient are obtained as a function of the slip velocity, void fraction, plume and bubble width based on three-dimensional measurements. We found that the classical integral theory agrees well with experiments in the plume region.
- Open Access
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
10.1063/5.0086383.10
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
Open Access10.1063/5.0086383.10
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- Open Access
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
10.1063/5.0086383.11
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
Open Access10.1063/5.0086383.11
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- Open Access
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
10.1063/5.0086383.12
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
Open Access10.1063/5.0086383.12
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- Open Access
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
10.1063/5.0086383.15
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
Open Access10.1063/5.0086383.15
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- Open Access
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
10.1063/5.0086383.8
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- 29 March 2022
- Published by AIP Publishing
- Vol. 34 (3) , 035133
Open Access10.1063/5.0086383.8
Exhalation of small aerosol particle droplets and their airborne transport, dispersion, and (local) accumulation in closed rooms have been identified as the main pathways for direct and indirect respiratory virus transmission from person to person, for example, for severe acute respiratory syndrome coronavirus-2 or measles. Therefore, understanding airborne transport mechanisms of aerosol particles inside closed populated rooms is an important key factor for assessing and optimizing various mitigation strategies. Unsteady flow features, which are typically evolving in such mixed convection flow scenarios, govern the respective particle transport properties. Experimental and numerical methods that enable capturing the related broad range of scales in such internal flows over many cubic meters in order to provide reliable data for the adaptation of proper mitigation measures (distances, masks, shields, air purifiers, ventilation systems, etc.) are required. In the present work, we show results of a large-scale, three-dimensional Lagrangian particle tracking (LPT) experiment, which has been performed in a 12-m3 generic test room capturing up to 3 × 106 long-lived and nearly neutrally buoyant helium-filled soap bubbles (HFSBs) with a mean diameter of dHFSB ∼370 μm as (almost) passive tracers. HFSBs are used as fluid mechanical replacements for small aerosol particles dP < 5 μm, which allow to resolve the Lagrangian transport properties and related unsteady flow field inside the whole room around a cyclically breathing thermal manikin with and without mouth-nose-masks and shields applied. Six high-resolution complementary metal-oxide semiconductor streaming cameras, a large array of powerful pulsed light emitting diodes, and the variable-time step Shake-The-Box LPT algorithm have been applied in this experimental study of internal flows in order to gain insight into the complex transient and turbulent aerosol particle transport and dispersion processes around a seated and breathing human model.
- 27 September 2019
- Published by Springer Nature
- p. 705-715
Investigation of 3D Coherent Structures in Turbulent Boundary Layers at High Reynolds Numbers Using MultiPulse-STB
- 27 September 2019
- Published by Springer Nature
- p. 705-715
Investigation of 3D Coherent Structures in Turbulent Boundary Layers at High Reynolds Numbers Using MultiPulse-STB