CTCatrine Tudor-Locke

Catrine Tudor-Locke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Catrine Tudor-Locke has a total of 200 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real-Time Versus Video-Recorded Step Count Validation Among Young Adults

    by Sicong Ren, Mariya Boikova, Cayla R. McAvoy, Agnes Bucko, Tahmina Begum, Mike Dulin, Spencer Ingoglia, Maha Raya, Leah Patterson, Daheia J. Barr-Anderson, et al.

    Background : Consumer Technology Association guidelines recommend two independent researchers review video recordings of treadmill bouts to verify accuracy of the number of steps taken. Performing multiple post hoc validation checks requires significant resources for personnel time and costs, but it is unknown if the burden is necessary. The purpose of this study was to evaluate accuracy and efficiency of step counts assessed during direct observation compared with multiple reviews of video recordings. Methods : Participants ages 18–20 years ( n = 72) completed up to twelve 5-min, zero-incline treadmill bouts, speeds ranging 0.2–2.7 m/s (0.5–6.0 mph). Directly observed steps were counted and hand-tallied in real-time. A sex-age stratified random sample of 30 participants’ bouts were selected for analysis. Two independent researchers recounted steps from video recordings, producing three independent counts. Intraclass correlation coefficient determined interrater reliability. Mean average percent deviation computed deviation magnitude among the three counts. Correlation tests determined the relationship between absolute count differences and average counts for each pairwise comparison. Results : Interrater reliability was excellent with intraclass correlation coefficients ≥ .995 ( p < .001) across all speeds. Average mean average percent deviation was 0.29% with bout-specific deviations ranging from 0.10% to 0.54%, indicating < 1% difference among the three counts for all bouts. Conclusions : A single real-time step count represents a sufficient and efficient approach to measure steps taken in a controlled treadmill setting, while video recounts serve as back-up to allay potential data loss concerns and/or for random selection verification. These data-driven findings are useful for optimizing personnel time and reducing costs associated with collecting quality data in large-scale treadmill-based step-counting studies.

  • Open Access

    Promoting Vigorous Intermittent Lifestyle Physical Activity (VILPA) in middle-aged adults: An evaluation of the MovSnax mobile app

    by Cecilie Thøgersen-Ntoumani, Anne Grunseit, Andreas Holtermann, Sarah Steiner, Catrine Tudor-Locke, Annemarie Koster, Nathan Johnson, Carol Maher, Matthew Ahmadi, Josephine Y. Chau, et al.

    Background: Most adults fail to meet the moderate to vigorous physical activity-based recommendations needed to maintain or improve health. Vigorous Intermittent Lifestyle Physical Activity (VILPA) refers to short (1-2 mins) high-intensity activities that are integrated into activities of daily living. VILPA has shown strong potential to improve health and addresses commonly reported barriers to physical activity. However, it is unknown how VILPA can best be promoted among the adult population. This study aimed to evaluate the usability, user engagement, and satisfaction of a mobile application (MovSnax) designed to promote VILPA. Methods: A concurrent mixed methods design was used. It comprised four parts. Part A was a survey with n =8 mHealth and physical activity experts who had used the app over 7-10 days. Part B was think- aloud interviews with n =5 end-users aged 40-65 years old. Part C was a survey with a new group of 40-65-year-old end-users ( n =35) who had used the MovSnax app over 7-10 days. Part D was semi- structured interviews with n =18 participants who took part in Part C. Directed content analysis was used to analyze the results from Parts A, B, and D, and descriptive statistics were used to analyze findings from Part C. Results: Participants reported positive views on the MovSnax app for promoting VILPA but also identified usability issues such as unclear purpose, difficulties in manual data entry, and limited customization options. Across the different data collections, they consistently emphasized the need for more motivational features, clearer feedback, and gamification elements to enhance engagement. Quantitative assessment showed satisfactory scores on objective measures but lower ratings on subjective aspects, possibly due to unfamiliarity with the VILPA concept and/or technical barriers. Conclusions: The MovSnax app, tested in the present study, is the world’s first digital tool aimed specifically at increasing VILPA. The findings of the present study underscore the need for further app refinement, focusing on clarifying its purpose and instructions, boosting user engagement through personalization and added motivational elements, enhancing accuracy in detecting VILPA bouts, implementing clearer feedback mechanisms, expanding customization choices (such as font size and comparative data), and ensuring transparent and meaningful activity tracking.

  • Open Access

    Cadence (steps/min) and relative intensity in 61 to 85-year-olds: the CADENCE-Adults study

    by Cayla R. McAvoy, Taavy A. Miller, Elroy J. Aguiar, Scott W. Ducharme, Christopher C. Moore, John M. Schuna, Tiago V. Barreira, Colleen J. Chase, Zachary R. Gould, Marcos A. Amalbert-Birriel, et al.

    Background: We previously demonstrated that a heuristic (i.e., evidence-based, rounded yet practical) cadence threshold of ≥ 100 steps/min was associated with absolutely-defined moderate intensity physical activity (i.e., ≥ 3 metabolic equivalents [METs]) in older adults 61–85 years of age. Although it was difficult to ascertain achievement of absolutely-defined vigorous (6 METs) intensity, ≥ 130 steps/min was identified as a defensible threshold for this population. However, little evidence exists regarding cadence thresholds andrelatively-defined moderate intensity indicators, including ≥ 64% heart rate [HR] maximum [HRmax= 220-age], ≥ 40% HR reserve [HRR = HRmax-HRresting], and ≥ 12 Borg Scale Rating of Perceived Exertion [RPE]; or vigorous intensity indicators including ≥ 77%HRmax, ≥ 60%HRR, and ≥ 14 RPE.Purpose: To analyze the relationship between cadence and relatively-defined physical activity intensity and identify relatively-defined moderate and vigorous heuristic cadence thresholds for older adults 61–85 years of age.Methods: Ninety-seven ostensibly healthy adults (72.7 ± 6.9 years; 49.5% women) completed up to nine 5-min treadmill walking bouts beginning at 0.5 mph (0.8 km/h) and progressing by 0.5 mph speed increments (with 2-min rest between bouts). Directly-observed (and video-recorded) steps were hand-counted, HR was measured using a chest-strapped monitor, and in the final minute of each bout, participants self-reported RPE. Segmented mixed model regression and Receiver Operating Characteristic (ROC) curve analyses identified optimal cadence thresholds associated with relatively-defined moderate (≥ 64%HRmax, ≥ 40%HRR, and ≥ 12 RPE) and vigorous (≥ 77%HRmax, ≥ 60%HRR, and ≥ 14 RPE) intensities. A compromise between the two analytical methods, including Youden’s Index (a sum of sensitivity and specificity), positive and negative predictive values, and overall accuracy, yielded final heuristic cadences.Results: Across all relatively-defined moderate intensity indicators, segmented regression models and ROC curve analyses identified optimal cadence thresholds ranging from 105.9 to 112.8 steps/min and 102.0-104.3 steps/min, respectively. Comparable values for vigorous intensity indicators ranged between126.1-132.1 steps/min and 106.7–116.0 steps/min, respectively. Regardless of the relatively-defined intensity indicator, the overall best heuristic cadence threshold aligned with moderate intensity was ≥ 105 steps/min. Vigorous intensity varied between ≥ 115 (greater sensitivity) or ≥ 120 (greater specificity) steps/min.Conclusions: Heuristic cadence thresholds align with relatively-defined intensity indicators and can be useful for studying and prescribing older adults’ physiological response to, and/or perceived experience of, ambulatory physical activity.Trial registration: Clinicaltrials.gov NCT02650258. Registered 24 December 2015.


  • Open Access

    Barriers and enablers of vigorous intermittent lifestyle physical activity (VILPA) in physically inactive adults: a focus group study

    by C. Thøgersen-Ntoumani, M. Kritz, A. Grunseit, J. Chau, M. Ahmadi, A. Holtermann, A. Koster, C. Tudor-Locke, N. Johnson, C. Sherrington, et al.

    Background: Vigorous Intermittent Lifestyle Physical Activity (VILPA) refers to brief bouts of vigorous intensity physical activity performed as part of daily living. VILPA has been proposed as a novel concept to expand physical activity options among the least active. As a nascent area of research, factors which impede or encourage VILPA in physically inactive adults are yet to be explored. Such information is pertinent in the design of future interventions. We examined the barriers and enablers of VILPA among physically inactive adults using the Capability, Opportunity, Motivation, Behavior (COM-B) model as a conceptual framework. Methods: We recruited a sample of self-identified physically inactive middle-aged and older adults (N = 78) based in Australia to take part in 19 online focus groups across three age groups: young-middle (age 35–44), middle (age 45–59) and old (age 60–76). We analyzed interviews using a critical realist approach to thematic analysis. Identified barriers and enablers were subsequently mapped onto the COM-B model components. Results: The data generated 6 barriers and 10 enablers of VILPA that corresponded to COM-B concepts. Barriers included physical limitations (physical capability), perceptions of aging, need for knowledge (psychological capability), environmental constraints (physical opportunity), perceptions of effort and energy, and fear (automatic motivation). Enablers included convenience, reframing physical activity as purposeful movement, use of prompts and reminders (physical opportunity), normalization of taking the active option, gamification (social opportunity), sense of achievement, health improvements, personally salient rewards (reflective motivation), identity fit, and changing from effortful deliberation to habitual action (automatic motivation). Conclusion: The barriers and enablers of VILPA span capability, opportunity, and motivation beliefs. Promoting the time-efficient nature and simplicity of VILPA requiring no equipment or special gym sessions, the use of prompts and reminders at opportune times, and habit formation strategies could capitalize on the enablers. Addressing the suitability of the small bouts, the development of specific guidelines, addressing safety concerns, and explicating the potential benefits of, and opportunities to do, VILPA could ameliorate some of the barriers identified. Future VILPA interventions may require limited age customization, speaking to the potential for such interventions to be delivered at scale.


  • Open Access

    A catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE-adults study

    by Jose Mora-Gonzalez, Zachary R. Gould, Christopher C. Moore, Elroy J. Aguiar, Scott W. Ducharme, John M. Schuna, Tiago V. Barreira, John Staudenmayer, Cayla R. McAvoy, Mariya Boikova, et al.

    Background: Standardized validation indices (i.e., accuracy, bias, and precision) provide a comprehensive comparison of step counting wearable technologies. Purpose: To expand a previously published child/youth catalog of validity indices to include adults (21–40, 41–60 and 61–85 years of age) assessed across a range of treadmill speeds (slow [0.8–3.2 km/h], normal [4.0–6.4 km/h], fast [7.2–8.0 km/h]) and device wear locations (ankle, thigh, waist, and wrist). Methods: Two hundred fifty-eight adults (52.5 ± 18.7 years, 49.6% female) participated in this laboratory-based study and performed a series of 5-min treadmill bouts while wearing multiple devices; 21 devices in total were evaluated over the course of this multi-year cross-sectional study (2015–2019). The criterion measure was directly observed steps. Computed validity indices included accuracy (mean absolute percentage error, MAPE), bias (mean percentage error, MPE), and precision (correlation coefficient, r; standard deviation, SD; coefficient of variation, CoV). Results: Over the range of normal speeds, 15 devices (Actical, waist-worn ActiGraph GT9X, activPAL, Apple Watch Series 1, Fitbit Ionic, Fitbit One, Fitbit Zip, Garmin vivoactive 3, Garmin vivofit 3, waist-worn GENEActiv, NL-1000, PiezoRx, Samsung Gear Fit2, Samsung Gear Fit2 Pro, and StepWatch) performed at < 5% MAPE. The wrist-worn ActiGraph GT9X displayed the worst accuracy across normal speeds (MAPE = 52%). On average, accuracy was compromised across slow walking speeds for all wearable technologies (MAPE = 40%) while all performed best across normal speeds (MAPE = 7%). When analyzing the data by wear locations, the ankle and thigh demonstrated the best accuracy (both MAPE = 1%), followed by the waist (3%) and the wrist (15%) across normal speeds. There were significant effects of speed, wear location, and age group on accuracy and bias (both p < 0.001) and precision (p ≤ 0.045). Conclusions: Standardized validation indices cataloged by speed, wear location, and age group across the adult lifespan facilitate selecting, evaluating, or comparing performance of step counting wearable technologies. Speed, wear location, and age displayed a significant effect on accuracy, bias, and precision. Overall, reduced performance was associated with very slow walking speeds (0.8 to 3.2 km/h). Ankle- and thigh-located devices logged the highest accuracy, while those located at the wrist reported the worst accuracy. Trial registration: Clinicaltrials.gov NCT02650258. Registered 24 December 2015.


  • Open Access

    Correction: Cadence (steps/min) and relative intensity in 21 to 60-year-olds: the CADENCE-adults study

    by Cayla R. McAvoy, Christopher C. Moore, Elroy J. Aguiar, Scott W. Ducharme, John M. Schuna, Tiago V. Barreira, Colleen J. Chase, Zachary R. Gould, Marcos A. Amalbert-Birriel, Stuart R. Chipkin, et al.

  • Open Access

    Walking cadence (steps/min) and intensity in 61–85-year-old adults: the CADENCE-Adults study

    by Catrine Tudor-Locke, Jose Mora-Gonzalez, Scott W. Ducharme, Elroy J. Aguiar, John M. Schuna, Tiago V. Barreira, Christopher C. Moore, Colleen J. Chase, Zachary R. Gould, Marcos A. Amalbert-Birriel, et al.

    Background: Heuristic (i.e., evidence-based, rounded) cadences of ≥100 and ≥ 130 steps/min have consistently corresponded with absolutely-defined moderate (3 metabolic equivalents [METs]) and vigorous (6 METs) physical activity intensity, respectively, in adults 21–60 years of age. There is no consensus regarding similar thresholds in older adults. Purpose: To provide heuristic cadence thresholds for 3, 4, 5, and 6 METs in 61–85-year-old adults. Methods: Ninety-eight community-dwelling ambulatory and ostensibly healthy older adults (age = 72.6 ± 6.9 years; 49% women) walked on a treadmill for a series of 5-min bouts (beginning at 0.5 mph with 0.5 mph increments) in this laboratory-based cross-sectional study until: 1) transitioning to running, 2) reaching ≥75% of their age-predicted maximum heart rate, or 3) reporting a Borg rating of perceived exertion > 13. Cadence was directly observed and hand-tallied. Intensity (oxygen uptake [VO2] mL/kg/min) was assessed with indirect calorimetry and converted to METs (1 MET = 3.5 mL/kg/min). Cadence thresholds were identified via segmented mixed effects model regression and using Receiver Operating Characteristic (ROC) curves. Final heuristic cadence thresholds represented an analytical compromise based on classification accuracy (sensitivity, specificity, positive and negative predictive value, and overall accuracy). Results: Cadences of 103.1 (95% Prediction Interval: 70.0–114.2), 116.4 (105.3–127.4), 129.6 (118.6–140.7), and 142.9 steps/min (131.8–148.4) were identified for 3, 4, 5, and 6 METs, respectively, based on the segmented regression. Comparable values based on ROC analysis were 100.3 (95% Confidence Intervals: 95.7–103.1), 111.5 (106.1–112.9), 116.0 (112.4–120.2), and 128.6 steps/min (128.3–136.4). Heuristic cadence thresholds of 100, 110, and 120 were associated with 3, 4, and 5 METs. Data to inform a threshold for ≥6 METs was limited, as only 6/98 (6.0%) participants achieved this intensity. Conclusions: Consistent with previous data collected from 21–40 and 41–60-year-old adults, heuristic cadence thresholds of 100, 110, and 120 steps/min were associated with 3, 4, and 5 METs, respectively, in 61–85-year-old adults. Most older adults tested did not achieve the intensity of ≥6 METs; therefore, our data do not support establishing thresholds corresponding with this intensity level. Trial registration: Clinicaltrials.gov NCT02650258. Registered 24 December 2015.


  • Open Access

    A catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE-Kids study

    by Zachary R. Gould, Jose Mora-Gonzalez, Elroy J. Aguiar, John M. Schuna, Tiago V. Barreira, Christopher C. Moore, John Staudenmayer, Catrine Tudor-Locke

    Background: Wearable technologies play an important role in measuring physical activity (PA) and promoting health. Standardized validation indices (i.e., accuracy, bias, and precision) compare performance of step counting wearable technologies in young people. Purpose: To produce a catalog of validity indices for step counting wearable technologies assessed during different treadmill speeds (slow [0.8–3.2 km/h], normal [4.0–6.4 km/h], fast [7.2–8.0 km/h]), wear locations (waist, wrist/arm, thigh, and ankle), and age groups (children, 6–12 years; adolescents, 13–17 years; young adults, 18–20 years). Methods: One hundred seventeen individuals (13.1 ± 4.2 years, 50.4% female) participated in this cross-sectional study and completed 5-min treadmill bouts (0.8 km/h to 8.0 km/h) while wearing eight devices (Waist: Actical, ActiGraph GT3X+, NL-1000, SW-200; Wrist: ActiGraph GT3X+; Arm: SenseWear; Thigh: activPAL; Ankle: StepWatch). Directly observed steps served as the criterion measure. Accuracy (mean absolute percentage error, MAPE), bias (mean percentage error, MPE), and precision (correlation coefficient, r; standard deviation, SD; coefficient of variation, CoV) were computed. Results: Five of the eight tested wearable technologies (i.e., Actical, waist-worn ActiGraph GT3X+, activPAL, StepWatch, and SW-200) performed at < 5% MAPE over the range of normal speeds. More generally, waist (MAPE = 4%), thigh (4%) and ankle (5%) locations displayed higher accuracy than the wrist location (23%) at normal speeds. On average, all wearable technologies displayed the lowest accuracy across slow speeds (MAPE = 50.1 ± 35.5%), and the highest accuracy across normal speeds (MAPE = 15.9 ± 21.7%). Speed and wear location had a significant effect on accuracy and bias (P < 0.001), but not on precision (P > 0.05). Age did not have any effect (P > 0.05). Conclusions: Standardized validation indices focused on accuracy, bias, and precision were cataloged by speed, wear location, and age group to serve as important reference points when selecting and/or evaluating device performance in young people moving forward. Reduced performance can be expected at very slow walking speeds (0.8 to 3.2 km/h) for all devices. Ankle-worn and thigh-worn devices demonstrated the highest accuracy. Speed and wear location had a significant effect on accuracy and bias, but not precision. Trial registration: Clinicaltrials.gov NCT01989104. Registered November 14, 2013.


  • Open Access

    Cadence (steps/min) and relative intensity in 21 to 60-year-olds: the CADENCE-adults study

    by Cayla R. McAvoy, Christopher C. Moore, Elroy J. Aguiar, Scott W. Ducharme, John M. Schuna, Tiago V. Barreira, Colleen J. Chase, Zachary R. Gould, Marcos A. Amalbert-Birriel, Stuart R. Chipkin, et al.

    Background: Heuristic cadence (steps/min) thresholds of ≥100 and ≥ 130 steps/min correspond with absolutely-defined moderate (3 metabolic equivalents [METs]; 1 MET = 3.5 mL O2·kg− 1·min− 1) and vigorous (6 METs) intensity, respectively. Scarce evidence informs cadence thresholds for relatively-defined moderate (≥ 64% heart rate maximum [HRmax = 220-age], ≥ 40%HR reserve [HRR = HRmax -HRresting, and ≥ 12 Rating of Perceived Exertion [RPE]); or vigorous intensity (≥ 77%HRmax, ≥ 60%HRR, and ≥ 14 RPE). Purpose: To identify heuristic cadence thresholds corresponding with relatively-defined moderate and vigorous intensity in 21–60-year-olds. Methods: In this cross-sectional study, 157 adults (40.4 ± 11.5 years; 50.6% men) completed up to twelve 5-min treadmill bouts, beginning at 0.5 mph and increasing by 0.5 mph. Steps were directly observed, HR was measured with chest-worn monitors, and RPE was queried in the final minute of each bout. Segmented mixed model regression and Receiver Operating Characteristic (ROC) curve analyses identified optimal cadence thresholds, stratified by age (21–30, 31–40, 41–50, and 51–60 years). Reconciliation of the two analytical models, including trade-offs between sensitivity, specificity, positive and negative predictive values, and overall accuracy, yielded final heuristic cadences. Results: Across all moderate intensity indicators, the segmented regression models estimated optimal cadence thresholds ranging from 123.8–127.5 (ages 21–30), 120.2–126.0 (ages 31–40), 117.7–122.7 (ages 41–50), and 113.3–116.1 steps/min (ages 51–60). Corresponding values for vigorous intensity were 140.3–144.1, 139.6–142.6, 139.3–143.6, and 131.6–132.8 steps/min, respectively. ROC analysis estimated chronologically-arranged age groups’ cadence thresholds ranging from 114.5–118, 113.5–114.5, 104.6–112.9, and 103.6–106.0 across all moderate intensity indicators, and 124.5, 121.5, 117.2–122.2, and 113.0 steps/min, respectively, for vigorous intensity. Conclusions: Heuristic cadence thresholds corresponding to relatively-defined moderate intensity for the chronologically-arranged age groups were ≥ 120, 120, 115, and 110 steps/min, regardless of the intensity indicator (i.e., % HRmax, %HRR, or RPE). Corresponding heuristic values for vigorous intensity indicators were ≥ 135, 130, 125, and 120 steps/min. These cadences are useful for predicting/programming intensity aligned with age-associated differences in physiological response to, and perceived experiences of, moderate and/or vigorous intensity. Trial registration: Clinicaltrials.gov NCT02650258. Registered 24 December 2015.