TUTakashi Ueguchi

Takashi Ueguchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takashi Ueguchi has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radiotherapy treatment planning with contrast-enhanced computed tomography: feasibility of dual-energy virtual unenhanced imaging for improved dose calculations

    by Sachiko Yamada, Takashi Ueguchi, Toshiyuki Ogata, Hirokazu Mizuno, Ryota Ogihara, Masahiko Koizumi, Takeshi Shimazu, Kenya Murase, Kazuhiko Ogawa

    In radiotherapy treatment planning, intravenous administration of an iodine-based contrast agent during computed tomography (CT) improves the accuracy of delineating target volumes. However, increased tissue attenuation resulting from the high atomic number of iodine may result in erroneous dose calculations because the contrast agent is absent during the actual procedure. The purpose of this proof-of-concept study was to present a novel framework to improve the accuracy of dose calculations using dual-energy virtual unenhanced CT in the presence of an iodine-based contrast agent. Simple phantom experiments were designed to assess the feasibility of the proposed concept. By utilizing a “second-generation” dual-source CT scanner equipped with a tin filter for improved spectral separation, four CT datasets were obtained using both a water phantom and an iodine phantom: “true unenhanced” images with attenuation values of 2 ± 11 Hounsfield Units (HU), “enhanced” images with attenuation values of 274 ± 23 HU, and two series of “virtual unenhanced” images synthesized from dual-energy scans of the iodine phantom, each with a different combination of tube voltages. Two series of virtual unenhanced images demonstrated attenuation values of 12 ± 29 HU (with 80 kVp/140 kVp) and 34 ± 10 HU (with 100 kVp/140 kVp) after removing the iodine component from the contrast-enhanced images. Dose distributions of the single photon beams calculated from the enhanced images and two series of virtual unenhanced images were compared to those from true unenhanced images as a reference. The dose distributions obtained from both series of virtual unenhanced images were almost equivalent to that from the true unenhanced images, whereas the dose distribution obtained from the enhanced images indicated increased beam attenuation caused by the high attenuation characteristics of iodine. Compared to the reference dose distribution from the true unenhanced images, the dose distribution pass rates from both series of virtual unenhanced images were greater than 90%, while those from the enhanced images were less than approximately 50–60%. Dual-energy virtual unenhanced CT improves the accuracy of dose distributions in radiotherapy treatment planning by removing the iodine component from contrast-enhanced images.


    • 1 January 2014
      • Vol. 34  (2) , 35-46

    [Perceptual image dissimilarity--a novel metric for objective assessment of image quality in computed tomography with iterative reconstruction].

    by Sachiko Yamada, Takashi Ueguchi, Toshiyuki Ogata, Ryota Ogihara, Kenya Murase

    An iterative reconstruction (IR) technique in computed tomography (CT) is expected to play an important role in reducing the radiation dose while preserving both spatial resolution and contrast-to-noise ratio. However, images obtained by using the IR technique are known to have different visual appearances from those obtained by using the traditional filtered back-projection (FBP) reconstruction. This appearance is often figuratively described as "blocky," but it has not been objectively characterized further. In this paper, we propose a novel image quality metric, called "perceptual image dissimilarity" (PID), to characterize the visual dissimilarity between FBP and IR images. The PID was formulated as a grayscale transformation and subsequent structural similarity (SSIM)-based image quality measurement. The PID metric was validated using phantom images with three different modules. Sixty datasets, each consisting of an IR image and its corresponding noise-level-equivalent FBP image, were visually assigned "subjective dissimilarity scores" on a five level scale by six observers. The data sets were then quantitatively analyzed using both the PID and the traditional mean squared error (MSE) metrics. Our results show that the PID is highly consistent with the subjective dissimilarity score and thus delivers superior performance, whereas the MSE fails to quantify the observers' visual perception.


  • Open Access

    Feasibility and accuracy of relative electron density determined by virtual monochromatic CT value subtraction at two different energies using the gemstone spectral imaging

    by Toshiyuki Ogata, Takashi Ueguchi, Masashi Yagi, Sachiko Yamada, Chikako Tanaka, Ryota Ogihara, Fumiaki Isohashi, Yasuo Yoshioka, Noriyuki Tomiyama, Kazuhiko Ogawa, et al.

    Recent work by Saito (2012) has demonstrated a simple conversion from energy-subtracted computed tomography (CT) values (ΔHU) obtained using dual-energy CT to relative electron density (RED) via a single linear relationship. The purpose of this study was to investigate the feasibility of this method to obtain RED from virtual monochromatic CT images obtained by the gemstone spectral imaging (GSI) mode with fast-kVp switching. A tissue characterization phantom with 13 inserts made of different materials was scanned using the GSI mode on a Discovery CT750 HD. Four sets of virtual monochromatic CT images (60, 77, 100 and 140 keV) were obtained from a single GSI acquisition. When we define Δ HU in terms of the weighting factor for the subtraction α, Δ HU ≡ (1 + α)H - αL (H and L represent the CT values for high and low energy respectively), the relationship between Δ HU and RED is approximated as a linear function, a × Δ HU/1000 + b (a, b = unity). We evaluated the agreement between the determined and nominal RED. We also have investigated reproducibility over short and long time periods. For the 13 insert materials, the RED determined by monochromatic CT images agreed with the nominal values within 1.1% and the coefficient of determination for this calculation formula was greater than 0.999. The observed reproducibility (1 standard deviation) of calculation error was within 0.5% for all materials. These findings indicate that virtual monochromatic CT scans at two different energies using GSI mode can provide an accurate method for estimating RED.


    • 1 February 2013
      • Vol. 40  (2) , 197-201

    [Impact of preventive administration of antiemetic drugs on risk of acute nausea and vomiting induced by transcatheter arterial chemoembolization in patients with hepatocellular carcinomas - a retrospective study].

    by Masako Kabuki, Hiroki Higashihara, Mami Kakuda, Yoko Fujita, Junichi Masuda, Kyoko Kin, Takashi Ueguchi, Keigo Osuga, Noriyuki Tomiyama

    This study aimed to evaluate the impact of the preventive administration of antiemetic drugs on the risk of acute nausea and vomiting induced by transcatheter arterial chemoembolization(TACE)in patients with hepatocellular carcinomas(HCCs). From January 2007 to June 2009, a total of 536 patients with HCCs who underwent TACE with a mixture of iodized oil, epirubicin, and porous gelatin particles were included in this retrospective study. Of those patients, 23 out of 357(6.4% ) who had received the 5-HT(3) receptor antagonist before TACE, and 18 out of 179(10.1% )without the medication, experienced vomiting. The multivariate logistic regression model with a predictive success of 92. 4% for vomiting identified significant associations between female gender(odds ratio: 3.73, p<0.001 ), the number of tumors(1.29, p<0.01 ), and administration of pentazocine(11.70, p<0.05)with the risk of vomiting. In contrast, the preventive administration of antiemetic drugs was not included in the model as a significant predictive variable. We therefore conclude from this retrospective study that the 5-HT(3) receptor antagonist did not significantly contribute to preventing the TACE-induced emesis.


  • Open Access

    Breast diffusion‐weighted MRI: Comparison of tetrahedral versus orthogonal diffusion sensitization for detection and localization of mass lesions

    by Takashi Ueguchi, Sachiko Yamada, Naoki Mihara, Yoshihiro Koyama, Hiromitsu Sumikawa, Noriyuki Tomiyama

    Purpose: To evaluate the potential of tetrahedral diffusion‐weighted imaging (DWI) compared to orthogonal DWI for detection and localization of early enhanced breast mass lesions at 1.5T. Materials and Methods: Sixty‐seven consecutive patients (mean age 51.7 years, range 14–84 years) with 68 solitary early enhanced breast lesions suspicious for cancer on dynamic contrast‐enhanced magnetic resonance imaging (MRI) were enrolled in this retrospective study. Two radiologists independently observed maximum intensity projection images of orthogonal and tetrahedral DWI and the diagnostic accuracy and background tissue visibility between two DWI techniques were compared. Contrast‐enhanced MRI was used as the reference standard. Background tissue visibility was assessed based on whether the “breast quadrant” and “skin line” were determined. A phantom validation study for apparent diffusion coefficient (ADC) values was also conducted. Results: Sensitivity (93%) and specificity (96%) on tetrahedral DWI were equivalent to those on orthogonal DWI (sensitivity, 88%; specificity, 95%). Background tissue was more easily determined with tetrahedral DWI (breast quadrant, 90%; skin lines, 95%) than with orthogonal DWI (breast quadrant, 61%; skin lines, 16%). ADC values of tetrahedral DWI were highly correlated with those of orthogonal DWI. Conclusion: Tetrahedral DWI provided equivalent detectability of mass lesions with improved visibility of surrounding anatomical structure. J. Magn. Reson. Imaging 2011;33:1375–1381.


  • Evaluation of usefulness of color digital summation radiography for solitary pulmonary nodules on chest radiographs

    by Yuji Ogata, Hiroaki Naito, Noriyuki Tomiyama, Seiki Hamada, Mitusko Tsubamoto, Atsuo Inoue, Sachiko Murai, Hiromitu Sumikawa, Takashi Ueguchi, Mitsuhiro Matsumoto, et al.


  • Novel display technique for reference images for visibility of temporal change on radiographs- color digital summation radiography-

    by Yuji Ogata, Hiroaki Naito, Hiroki Azuma, Hironari Toyota, Takashi Ueguchi, Mitsuhiro Matsumoto, Shinichi Tamura, Hironobu Nakamura, Takeshi Johkon

    Purpose The present study investigated color digital summation radiography (CDSR) as a novel display technique for reference images for the visibility of temporal change on radiographs. In CDSR, only the parts with temporal differences are displayed in color. Moreover, all other parts are displayed in gray scale. Materials and Methods CDSR was defined as “radiographs combined by the additive color mixture method”. The visibility of simulated nodules located in the lung fields and mediastinum was evaluated by 12 radiologists (mean experience, 9.8 years; range, 1–26 years) for 24 conventional radiographs and CDSR for 6 color patterns. A five-point rating system (5, very good; 4, good; 3, adequate; 2, poor; 1, very poor) was used. Results The mean scores (average±standard deviation) for the visibility of simulated nodules were as follows: magenta, 3.88±0.90; blue, 3.08±0.72; green, 3.04±0.86; red, 3.00±0.98; cyan, 2.71±0.86; and yellow, 2.50±0.72. Compared to conventional radiography in gray scale, at 1.21±0.41, all six color patterns for CDSR displayed significantly improved scores (p<0.001). Conclusion CDSR might represent a useful technique for reference images from chest digital radiography.


  • Air Microbubbles as MR Susceptibility Contrast Agent at 1.5 Tesla

    by Takashi Ueguchi, Yuko Tanaka, Seiki Hamada, Risa Kawamoto, Yuji Ogata, Mitsuhiro Matsumoto, Hironobu Nakamura, Takeshi Johkoh

    Air microbubbles have been investigated recently at high magnetic field strength (2 Tesla or greater) as potential MR susceptibility contrast agents. We used a phantom to measure their susceptibility at 1.5T to clarify their usefulness for this purpose. The phantom, filled with fresh Levovist® suspension at 4 different doses (67 to 125 mg/mL), was continuously scanned with a gradient-echo technique at a temporal resolution of 10 s. The transverse relaxation increase (R2*) by microbubbles demonstrated a time course of exponential decay at each dose (time-constant, 39 to 57 s). The dependency of R2* on microbubble volume fraction was linear, with a slope of 89 s-1 per percentage microbubble volume fraction. Our study represents the first step towards applying microbubbles as susceptibility contrast agents at 1.5T.


    • 28 January 2004
      • Vol. 21  (6) , 280-4

    Real-time estimation system for mean glandular dose in mammography.

    by Mitsuhiro Matsumoto, Shinichi Inoue, Ikuko Honda, Shuji Yamamoto, Takashi Ueguchi, Yuji Ogata, Takeshi Johkoh

    The purpose of this study was to construct a system that calculates mean glandular dose (MGD) in mammography in real-time on the RIS network. Measurement of the half-value layer (HVL) and exposure dose were measured according to the Japanese mammographic quality control manual. A parallel plate chamber (10X5-6M; soft X-rays only) was used for measurement. Exposure dose was measured from 26 to 32 kV. Effective energy (Eeff [keV]) could be determined from tube voltage (V [kV] ) using the measure of the HVL according to the following equations: for the Mo/Mo combination, Eeff = 0.1325V + 11.80; for the Mo/Rh combination, Eeff = 0.1435V + 12.20; for the Rh/Rh combination, Eeff = 0.1724V + 11.29. Exposure output (XmAs [mR/mAs]), which can be determined from dosimetry per 1 mAs, becomes the following equation if effective energy is expressed as a variable: for the Mo/Mo combination, XmAs = 2.1329 Eeff2 - 57.784 Eeff + 392.71; for the Mo/Rh combination, XmAs = 1.1919 Eeff2 - 31.924 Eeff + 212.23; and for the Rh/Rh combination, XmAs = 2.6929 Eeff2 - 82.831 Eeff + 643.54. The MGD conversion factor (DgN [mGy/mR]) can be determined from effective energy using the ACR protocol according to the following equation: for the Mo/Mo combination, DgN = (0.3962 Eeff- 4.3178) 10(-3); for the Mo/Rh combination, DgN = (0.3495 Eeff - 3.5479) x 10(-3); and for the Rh/Rh combination, DgN = (0.4498 Eeff - 5.0448) x 10(-3). However, in these cases, compression breast thickness (CBT) was 4.2 cm, and the ratio of adipose and glandular tissue was 50/50. MGD can be determined using mAs obtained from mammography, exposure output (XmAs), MGD conversion factor (DgN), and source-skin distance compensation factor (SSDcf) according to the following equation: MGD [mGy] = mAs x XmAs [mR/mAs] x DgN [mGy/mR] x SSDcf where SSDcf = (64/(64 - CBT [cm]))2.

    • 1 January 2003
      • Vol. 23  (4) , 232-42

    Analysis of entrance surface dose in general radiographies using body mass index classification.

    by Mitsuhiro Matsumoto, Seiichi Ota, Shinichi Inoue, Yuji Ogata, Shuji Yamamoto, Takashi Ueguchi, Takeshi Johkoh

    Dose audit is an important topic in radiology and variations in dose attributable to sex have not been fully investigated. The primary purpose of our study was to determine the entrance surface dose (ESD) for men and women, from which we established an easy estimation equation for ESD, using the body mass index (BMI) as a variable. From April 2000 to March 2002, 15424 patients (8586 men, 6838 women; mean age, 58 years old; age range, 20 to 90 years old) were recruited in this study. Estimated equation of ESD was obtained from the dispersion data of BMI and ESD. Welch's t-test was used as the test of significance. P values evaluated levels of significance at 5%. Analysis for correlation coefficients was used for Peason's correlation coefficient test. And, we also performed a simple regression analysis. The results of the simple regression equation with BMI as variable (y: ESD [mGy], x: BMI [kg/m(2)), and the median values of ESD were as follows: for chest PA, men, 0.22, y = 0.0145 x - 0.0876, women, 0.20, y = 0.0126 x - 0.0704; for abdomen AP, men, 2.12, y = 0.2707 x - 3.7206, women, 1.65, y = 0.2561 x - 3.7989; for pelvis AP, men, 1.87, y = 0.0517 x + 0.8753, women, 1.77, y = 0.0674 x + 0.4775; for lumbar spine AP, men, 3.08, y = 0.3462 x - 4.1416, women, 2.66, y = 0.2525 x - 2.8131; and for lumbar spine lateral, men, 9.31, y = 0.6012 x - 3.7216, women, 7.42, y = 0.3147 x + 0.3384. The results of ESD had a significant difference between sexes (P < 0.05). Chest PA, abdomen AP, lumbar spine AP, and lumbar spine lateral each had a good correlation between ESD and BMI (r: 0.4 to 0.8). We successfully obtained the estimation equation using BMI as variable.