Fariborz Vafaee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fariborz Vafaee has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Masoumeh Khoshhal
Department of Periodontics, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
8 shared publications Bijan Heidari
5 shared publicationsMasoumeh Khoshhal
4 shared publications- Hanif Allahbakhshi
Department of Prosthodontics, Faculty of Dentistry, Kashan University of Medical Sciences, Kashan, Iran
3 shared publications - Maryam Farhadian
Department of Biostatistics, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
3 shared publications - Sajjad Farashi
Neurophysiology Research Center, Institute of Neuroscience and Mental Health, Avicenna Health Research Institute, Hamadan University of Medical Sciences, Hamadan, Iran
3 shared publications
Latest Publications
- 30 December 2025
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 17  (4) , 235-240
Seating Accuracy of Printed Artificial Teeth in Complete Prostheses at Different Print Angles
Background: 3D printers are widely utilized in dentistry for complete prostheses due to fast production, high accuracy, and personal customization.Although these printers have had a significant effect on improving the treatment and manufacturing of tools and prostheses, the techniques used in printing 3D models are still unable to provide ideal quality in all applications, and many variables can affect the accuracy of 3D printing models. The purpose of this study was to compare the difference in the seating accuracy of printed artificial teeth in the resin base cavities of complete prostheses at different print angles with the aim of reducing the created errors. Methods: First, a scan was prepared from the cast of a patient. Then, the teeth and prosthetic base were designed for a single toothless area, and a total of 60 artificial teeth and bases were printed separately at three angles of 0°, 45°, and 90°. The correct seating of these teeth in the base cavities was evaluated by re-scanning and checking in the software (Dental cad, exocad, GMBH, version 3). Results: In the palatal region, the midpoint-to-midpoint (M.M.) and vertical measurement at a 45° angle had the most accuracy, while in the cylinder-to-cylinder (C.C.) measurement, the highest accuracy was observed at a 0° angle (P<0.001). In the buccal area, the M.M. measurement demonstrated the highest accuracy at a 90° angle, the C.C. measurement at a 0° angle, and the vertical measurement at a 45° angle (P<0.001). Conclusion: Based on the findings, there was a significant difference with the gold standard for all printing angles in various measurements of the accuracy of tooth seating in the printed resin base.
- 30 December 2025
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 17  (4) , 235-240
Seating Accuracy of Printed Artificial Teeth in Complete Prostheses at Different Print Angles
Background: 3D printers are widely utilized in dentistry for complete prostheses due to fast production, high accuracy, and personal customization.Although these printers have had a significant effect on improving the treatment and manufacturing of tools and prostheses, the techniques used in printing 3D models are still unable to provide ideal quality in all applications, and many variables can affect the accuracy of 3D printing models. The purpose of this study was to compare the difference in the seating accuracy of printed artificial teeth in the resin base cavities of complete prostheses at different print angles with the aim of reducing the created errors. Methods: First, a scan was prepared from the cast of a patient. Then, the teeth and prosthetic base were designed for a single toothless area, and a total of 60 artificial teeth and bases were printed separately at three angles of 0°, 45°, and 90°. The correct seating of these teeth in the base cavities was evaluated by re-scanning and checking in the software (Dental cad, exocad, GMBH, version 3). Results: In the palatal region, the midpoint-to-midpoint (M.M.) and vertical measurement at a 45° angle had the most accuracy, while in the cylinder-to-cylinder (C.C.) measurement, the highest accuracy was observed at a 0° angle (P<0.001). In the buccal area, the M.M. measurement demonstrated the highest accuracy at a 90° angle, the C.C. measurement at a 0° angle, and the vertical measurement at a 45° angle (P<0.001). Conclusion: Based on the findings, there was a significant difference with the gold standard for all printing angles in various measurements of the accuracy of tooth seating in the printed resin base.
- Open Access
- 21 April 2025
- Published by Maad Rayan Publishing Company in Journal of Advanced Periodontology & Implant Dentistry
- Vol. 17  (2) , 65-70
Effect of emergence profile and space gap size on excess cement in cement-retained implant reconstructions
Effect of emergence profile and space gap size on excess cement in cement-retained implant reconstructions
- 21 April 2025
- Published by Maad Rayan Publishing Company in Journal of Advanced Periodontology & Implant Dentistry
- Vol. 17  (2) , 65-70
Open AccessEffect of emergence profile and space gap size on excess cement in cement-retained implant reconstructions
Effect of emergence profile and space gap size on excess cement in cement-retained implant reconstructions
- Open Access
- 26 April 2024
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 26  (2) , 62-70
Effect of Temporary Cement on the Color of Temporary Crowns Made by Conventional Pressing Methods and Substractive CAM/CAD Technologies
The color stability of temporary restoration is crucial, especially in sensitive areas in terms of aesthetics. This research aimed to determine the effect of temporary cement on the color of temporary crowns made by conventional pressing methods (indirect) and CAM/CAD technologies using milling machines and 3D printers. This study was carried out in a laboratory, utilizing A2 color in all manufacturing methods. The color of the restorations was measured by a spectrophotometer after cementation with semi-permanent resin cement. Subsequently, color changes of the samples (ranging from 0 to 100) were calculated using the Commission International de l'Eclairage (CIE) Lab system. Data analysis was based on descriptive statistics methods and statistical tests, including one-way analysis of variance (ANOVA) and Tukey's post hoc test. According to the results of ANOVA, there was a significant difference between the three groups in terms of the 'a' and 'b' indexes (P<0.001). However, regarding the 'l' index, no significant difference was observed among the three groups (P=0.250). Also, based on Tukey's post hoc test, a significant relationship was seen between the first and second pairs in the 3D printer group, and between the first and third pairs in the milling group (P<0.001). However, no significant difference was observed in the conventional pressing group. The results showed that the 3D printing method exhibited the highest amount of color change among the three methods, while the milling method demonstrated the lowest amount of change.
- 26 April 2024
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 26  (2) , 62-70
Open AccessEffect of Temporary Cement on the Color of Temporary Crowns Made by Conventional Pressing Methods and Substractive CAM/CAD Technologies
The color stability of temporary restoration is crucial, especially in sensitive areas in terms of aesthetics. This research aimed to determine the effect of temporary cement on the color of temporary crowns made by conventional pressing methods (indirect) and CAM/CAD technologies using milling machines and 3D printers. This study was carried out in a laboratory, utilizing A2 color in all manufacturing methods. The color of the restorations was measured by a spectrophotometer after cementation with semi-permanent resin cement. Subsequently, color changes of the samples (ranging from 0 to 100) were calculated using the Commission International de l'Eclairage (CIE) Lab system. Data analysis was based on descriptive statistics methods and statistical tests, including one-way analysis of variance (ANOVA) and Tukey's post hoc test. According to the results of ANOVA, there was a significant difference between the three groups in terms of the 'a' and 'b' indexes (P<0.001). However, regarding the 'l' index, no significant difference was observed among the three groups (P=0.250). Also, based on Tukey's post hoc test, a significant relationship was seen between the first and second pairs in the 3D printer group, and between the first and third pairs in the milling group (P<0.001). However, no significant difference was observed in the conventional pressing group. The results showed that the 3D printing method exhibited the highest amount of color change among the three methods, while the milling method demonstrated the lowest amount of change.
- Open Access
- 17 April 2023
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 15  (2) , 42-46
Amount of Residual Cement at the Margin of Implant-Supported Crowns Cemented Using the Polytetrafluoroethylene Tape, Replica Technique, and Conventional Cementation Technique
Background: This study compared the amount of residual cement at the margin of implant-supported crowns cemented using the polytetrafluoroethylene (PTFE) tape, replica technique, and conventional cementation technique. Methods: In this in vitro experimental study, a mandibular model underwent full-arch scanning. The right first molar tooth was eliminated on the scan using Exocad software, and a regular implant analog was modelled using the Exocad model creator. The designed abutment was then printed. The implant analog was fixed in place with acrylic resin and scanned using a scan body. A full-zirconia custom abutment was then designed by Exocad. Abutments were fabricated using zirconia and sintered. Twenty-seven resin crowns were fabricated for the abutments, and their fit was assessed. Nine crowns were conventionally cemented by filling half of the crown space with cement, 9 crowns were cemented using PTFE tape, and the remaining 9 were first placed on a resin replica and then cemented on the abutments. The residual cement was weighed using a digital scale, and the groups were compared by one-way ANOVA and LSD test (α=0.05). Results: The amount of residual cement was significantly different among the three groups, indicating that the amount of residual cement was the highest in conventional cementation, and the lowest in the replica group (P < 0.05). Pairwise comparisons showed significant differences between all groups (P < 0.05). Conclusions: The replica technique followed by the PTFE tape resulted in the minimum amount of residual cement at the margin of implant-supported cement-retained crowns and are preferred for use in the clinical setting.
- 17 April 2023
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 15  (2) , 42-46
Open AccessAmount of Residual Cement at the Margin of Implant-Supported Crowns Cemented Using the Polytetrafluoroethylene Tape, Replica Technique, and Conventional Cementation Technique
Background: This study compared the amount of residual cement at the margin of implant-supported crowns cemented using the polytetrafluoroethylene (PTFE) tape, replica technique, and conventional cementation technique. Methods: In this in vitro experimental study, a mandibular model underwent full-arch scanning. The right first molar tooth was eliminated on the scan using Exocad software, and a regular implant analog was modelled using the Exocad model creator. The designed abutment was then printed. The implant analog was fixed in place with acrylic resin and scanned using a scan body. A full-zirconia custom abutment was then designed by Exocad. Abutments were fabricated using zirconia and sintered. Twenty-seven resin crowns were fabricated for the abutments, and their fit was assessed. Nine crowns were conventionally cemented by filling half of the crown space with cement, 9 crowns were cemented using PTFE tape, and the remaining 9 were first placed on a resin replica and then cemented on the abutments. The residual cement was weighed using a digital scale, and the groups were compared by one-way ANOVA and LSD test (α=0.05). Results: The amount of residual cement was significantly different among the three groups, indicating that the amount of residual cement was the highest in conventional cementation, and the lowest in the replica group (P < 0.05). Pairwise comparisons showed significant differences between all groups (P < 0.05). Conclusions: The replica technique followed by the PTFE tape resulted in the minimum amount of residual cement at the margin of implant-supported cement-retained crowns and are preferred for use in the clinical setting.
- 18 January 2022
- Published by Springer Nature in International Journal on Interactive Design and Manufacturing (IJIDeM)
- Vol. 16  (1) , 305-316
Effect of extruder temperature and printing speed on the tensile strength of fused deposition modeling (FDM) 3D printed samples: a meta-analysis study
- 18 January 2022
- Published by Springer Nature in International Journal on Interactive Design and Manufacturing (IJIDeM)
- Vol. 16  (1) , 305-316
Effect of extruder temperature and printing speed on the tensile strength of fused deposition modeling (FDM) 3D printed samples: a meta-analysis study
- 16 January 2022
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 7  (4) , 565-582
Effect of printing parameters on the tensile strength of FDM 3D samples: a meta-analysis focusing on layer thickness and sample orientation
- 16 January 2022
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 7  (4) , 565-582
Effect of printing parameters on the tensile strength of FDM 3D samples: a meta-analysis focusing on layer thickness and sample orientation
- 7 April 2021
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 40  (1) , 10-17
Effect of green synthesized silver nanoparticles on optical behavior of feldspathic porcelain
In this study, pomegranate peel extract (PPE) was used for the green synthesis of silver nanoparticles (AgNPs). The AgNPs were characterized by X-ray diffraction pattern (XRD) and transmission electron microscopy (TEM). TEM micrograph showed the spherical shape of AgNPs sized between 30 and 50 nm. XRD confirmed the face-centered cubic (FCC) crystalline structure of AgNPs. The antibacterial activity and cellular toxicity of the modified porcelain with AgNPs were also studied. The results of biocompatibility of modified porcelain with AgNPs revealed that samples decreased the viability of L929 cells and after treatment with AgNPs samples antibacterial activity was significantly increased. The effect of AgNPs on the optical behavior (color change (ΔE), contrast ratio (CR), and translucency parameter (TP)) of feldspathic porcelain was investigated by clinical spectrophotometer. It was shown that addition of AgNPs to feldspathic porcelain significantly increased the TP and decreased the CR compared to the control group. The results of this study indicate that addition of AgNPs up to 500 µg/mL AgNPs to VitaVM9 feldspathic porcelain did not cause the clinically recognizable threshold color change (ΔE = 2.69) and increases the ceramic translucency.
- 7 April 2021
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 40  (1) , 10-17
Effect of green synthesized silver nanoparticles on optical behavior of feldspathic porcelain
In this study, pomegranate peel extract (PPE) was used for the green synthesis of silver nanoparticles (AgNPs). The AgNPs were characterized by X-ray diffraction pattern (XRD) and transmission electron microscopy (TEM). TEM micrograph showed the spherical shape of AgNPs sized between 30 and 50 nm. XRD confirmed the face-centered cubic (FCC) crystalline structure of AgNPs. The antibacterial activity and cellular toxicity of the modified porcelain with AgNPs were also studied. The results of biocompatibility of modified porcelain with AgNPs revealed that samples decreased the viability of L929 cells and after treatment with AgNPs samples antibacterial activity was significantly increased. The effect of AgNPs on the optical behavior (color change (ΔE), contrast ratio (CR), and translucency parameter (TP)) of feldspathic porcelain was investigated by clinical spectrophotometer. It was shown that addition of AgNPs to feldspathic porcelain significantly increased the TP and decreased the CR compared to the control group. The results of this study indicate that addition of AgNPs up to 500 µg/mL AgNPs to VitaVM9 feldspathic porcelain did not cause the clinically recognizable threshold color change (ΔE = 2.69) and increases the ceramic translucency.
- Open Access
- 1 January 2021
- Published by XMLink in Imaging Science in Dentistry
- Vol. 51  (1) , 41-47
Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography
Yousefi F, et al. Imaging Sci Dent. 2021 Jan;51:e6. https://doi.org/10.5624/isd.20200175
- 1 January 2021
- Published by XMLink in Imaging Science in Dentistry
- Vol. 51  (1) , 41-47
Open AccessAccuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography
Yousefi F, et al. Imaging Sci Dent. 2021 Jan;51:e6. https://doi.org/10.5624/isd.20200175
- Open Access
- 21 June 2017
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 11  (2) , 78-83
Immediate vs. delayed endosseous integration of maxi implants: a torque removal animal study
Background. Delayed loading is one of the concerns in implant patients. Immediate loading can solve the problem and make patients more satisfied. The present study aimed to compare the removal torque of maxi implants under different loading (immediate and delayed) patterns.
- 21 June 2017
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 11  (2) , 78-83
Open AccessImmediate vs. delayed endosseous integration of maxi implants: a torque removal animal study
Background. Delayed loading is one of the concerns in implant patients. Immediate loading can solve the problem and make patients more satisfied. The present study aimed to compare the removal torque of maxi implants under different loading (immediate and delayed) patterns.
- Open Access
- 25 March 2017
- Published by Oriental Scientific Publishing Company in Biomedical and Pharmacology Journal
- Vol. 10  (1) , 51-58
A Comparative Study Of Flexural Strength And Fatigue Resistance Of 2 Nanoceramic Composite Resin Cad/Cam Blocks (Lava Ultimate And Vita Enamic) And A Lithium Disilicate Glass Ceramic (Ips E.Max Cad)
Biomedical and Pharmacology Journal (BPJ) is an international, open access, peer reviewed, quarterly research journal.
- 25 March 2017
- Published by Oriental Scientific Publishing Company in Biomedical and Pharmacology Journal
- Vol. 10  (1) , 51-58
Open AccessA Comparative Study Of Flexural Strength And Fatigue Resistance Of 2 Nanoceramic Composite Resin Cad/Cam Blocks (Lava Ultimate And Vita Enamic) And A Lithium Disilicate Glass Ceramic (Ips E.Max Cad)
Biomedical and Pharmacology Journal (BPJ) is an international, open access, peer reviewed, quarterly research journal.