Guangju Meng
Guangju Meng has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Cuifang Nie
Taian Cent Hosp, Dept Infect Dis, Tai An, Shandong, Peoples R China
1 shared publication - Laifei Cheng
Science and Technology on Thermostructural Composite Materials Laboratory Northwestern Polytechnical University 710072 Xi'an China
1 shared publication - Li Chen
Taian Cent Hosp, Dept Infect Dis, Tai An, Shandong, Peoples R China
1 shared publication - Li Liu
Taian Cent Hosp, Dept Infect Dis, Tai An, Shandong, Peoples R China
1 shared publication Litong Zhang
Science and Technology on Thermostructural Composite Materials Laboratory and State Key Laboratory of Solidification Processing, Northwestern Polytechnical University , 710072 Xi'an, China
1 shared publication- Qin Sun
Taian Cent Hosp, Dept Infect Dis, Tai An, Shandong, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 18 August 2021
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 30 (8) , 789-795
Expression of miR-9a-5p in cirrhosis patients with recurrent portal hypertension after treatment
Background. MicroRNA (miR) influences the biological activities of cirrhotic patients with recurrent portal hypertension. Objectives. The current study was designed to investigate risk factors related to the survival of cirrhosis patients and assessed the possibility of using miR-9a-5p predictability to prevent post-treatment portal hypertension. Materials and methods. Patients with portal hypertension due to liver cirrhosis treated from January 2015 to September 2016 were included in this study. Patients without relapse after treatment were selected as the success group while patients with relapse after treatment were selected as the recurrence group. Serum samples from healthy people were also collected. The blood indexes of the 2 groups of patients before and after treatment were compared and the miR-9a-5p serum level in each group was determined. The Kaplan-Meier method was applied to analyze three-year survival, Cox univariate regression was used to analyze the risk factors for recurrence of cirrhotic portal hypertension, and the receiver operating characteristic curve (ROC) was used to evaluate the diagnostic value of serum miR-9a-5p, total bilirubin (TBIL) and platelet (PLT) levels in patients with recurrence. Results. The miR-9a-5p level in the recurrence group was higher than that in the success group after treatment. In patients with recurrence, the miR-9a-5p level was negatively correlated with red blood cell count, TBIL, white blood cell count, and PLT count, and positively correlated with albumin. The miR-9a-5p, TBIL and PLT are potential markers of recurrent portal hypertension in liver cirrhosis. The miR-9a-5p had the highest area under the curve (AUC) value in patients with relapse. Conclusions. The miR-9a-5p is a risk factor for the recurrence of cirrhotic portal hypertension after treatment. It may be used as a marker of recurrence, and so has potential clinical value for the diagnosis and treatment of recurrent portal hypertension.
- 18 August 2021
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 30 (8) , 789-795
Open AccessExpression of miR-9a-5p in cirrhosis patients with recurrent portal hypertension after treatment
Background. MicroRNA (miR) influences the biological activities of cirrhotic patients with recurrent portal hypertension. Objectives. The current study was designed to investigate risk factors related to the survival of cirrhosis patients and assessed the possibility of using miR-9a-5p predictability to prevent post-treatment portal hypertension. Materials and methods. Patients with portal hypertension due to liver cirrhosis treated from January 2015 to September 2016 were included in this study. Patients without relapse after treatment were selected as the success group while patients with relapse after treatment were selected as the recurrence group. Serum samples from healthy people were also collected. The blood indexes of the 2 groups of patients before and after treatment were compared and the miR-9a-5p serum level in each group was determined. The Kaplan-Meier method was applied to analyze three-year survival, Cox univariate regression was used to analyze the risk factors for recurrence of cirrhotic portal hypertension, and the receiver operating characteristic curve (ROC) was used to evaluate the diagnostic value of serum miR-9a-5p, total bilirubin (TBIL) and platelet (PLT) levels in patients with recurrence. Results. The miR-9a-5p level in the recurrence group was higher than that in the success group after treatment. In patients with recurrence, the miR-9a-5p level was negatively correlated with red blood cell count, TBIL, white blood cell count, and PLT count, and positively correlated with albumin. The miR-9a-5p, TBIL and PLT are potential markers of recurrent portal hypertension in liver cirrhosis. The miR-9a-5p had the highest area under the curve (AUC) value in patients with relapse. Conclusions. The miR-9a-5p is a risk factor for the recurrence of cirrhotic portal hypertension after treatment. It may be used as a marker of recurrence, and so has potential clinical value for the diagnosis and treatment of recurrent portal hypertension.
- 21 August 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (34) , 28844-28858
Flexible SiC/Si3N4 Composite Nanofibers with in Situ Embedded Graphite for Highly Efficient Electromagnetic Wave Absorption
SiC/Si3N4 composite nanofibers with in situ embedded graphite, which show highly efficient electromagnetic (EM) wave absorption performance in gigahertz frequency, were prepared by electrospinning with subsequent polymer pyrolysis and annealing. By means of incorporating graphite and Si3N4 into SiC, the EM wave absorption properties of the nanofibers were improved. The relationship among processing, fiber microstructure, and their superior EM wave absorption performance was systematically investigated. The EM wave absorption capability and effective absorption bandwidth (EAB) of nanofibers can be simply controlled by adjusting annealing atmosphere and temperature. The nanofibers after annealing at 1300 °C in Ar present a minimum reflection loss (RL) of −57.8 dB at 14.6 with 5.5 GHz EAB. The nanofibers annealed in N2 at 1300 °C exhibit a minimum RL value of −32.3 dB at a thickness of 2.5 mm, and the EAB reaches 6.4 GHz over the range of 11.3–17.7 GHz. The highly efficient EM wave absorption performance of nanofibers are closely related to dielectric loss, which originated from interfacial polarization and dipole polarization. The excellent absorbing performance together with wider EAB endows the composite nanofibers potential to be used as reinforcements in polymers and ceramics (SiC, Si3N4, SiO2, Al2O3, etc.) to improve their EM wave absorption performance.
- 21 August 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (34) , 28844-28858
Flexible SiC/Si3N4 Composite Nanofibers with in Situ Embedded Graphite for Highly Efficient Electromagnetic Wave Absorption
SiC/Si3N4 composite nanofibers with in situ embedded graphite, which show highly efficient electromagnetic (EM) wave absorption performance in gigahertz frequency, were prepared by electrospinning with subsequent polymer pyrolysis and annealing. By means of incorporating graphite and Si3N4 into SiC, the EM wave absorption properties of the nanofibers were improved. The relationship among processing, fiber microstructure, and their superior EM wave absorption performance was systematically investigated. The EM wave absorption capability and effective absorption bandwidth (EAB) of nanofibers can be simply controlled by adjusting annealing atmosphere and temperature. The nanofibers after annealing at 1300 °C in Ar present a minimum reflection loss (RL) of −57.8 dB at 14.6 with 5.5 GHz EAB. The nanofibers annealed in N2 at 1300 °C exhibit a minimum RL value of −32.3 dB at a thickness of 2.5 mm, and the EAB reaches 6.4 GHz over the range of 11.3–17.7 GHz. The highly efficient EM wave absorption performance of nanofibers are closely related to dielectric loss, which originated from interfacial polarization and dipole polarization. The excellent absorbing performance together with wider EAB endows the composite nanofibers potential to be used as reinforcements in polymers and ceramics (SiC, Si3N4, SiO2, Al2O3, etc.) to improve their EM wave absorption performance.