Robert Kamberger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert Kamberger has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jan Gerrit Korvink
Institute of Microstructure Technology Karlsruhe Institute of Technology Eggenstein‐Leopoldshafen Germany
3 shared publications - Jürgen Hennig
Division of Medical Physics, Department Radiology Medical Center – University of Freiburg, Faculty of Medicine – University of Freiburg Freiburg Germany
2 shared publications - Alexander Däpp
Department of Chemistry and Applied Biosciences, Eidgenössische Technische Hochschule Zürich, Zürich 8049, Switzerland
1 shared publication Andreas Hunkeler
Physical Chemistry, ETH Zurich, Vladimir-Prelog-Weg 2, 8093 Zurich, Switzerland
1 shared publication- Beat H. Meier
Physical Chemistry, ETH Zurich, 8093 Zurich, Switzerland
1 shared publication - Carola A. Haas
Experimental Epilepsy Research, Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, Freiburg, Germany
1 shared publication
Latest Publications
- 1 February 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 299, 196-201
Microscale 3D imaging by magnetic resonance force microscopy using full-volume Fourier- and Hadamard-encoding
- 1 February 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 299, 196-201
Microscale 3D imaging by magnetic resonance force microscopy using full-volume Fourier- and Hadamard-encoding
- 1 October 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 52, 24-32
Improved method for MR microscopy of brain tissue cultured with the interface method combined with Lenz lenses
- 1 October 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 52, 24-32
Improved method for MR microscopy of brain tissue cultured with the interface method combined with Lenz lenses
- Open Access
- 1 July 2017
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 47B (3) , e21357
A comparison of Lenz lenses and LC resonators for NMR signal enhancement
High signal‐to‐noise ratio (SNR) of the NMR signal has always been a key target that drives massive research effort in many fields. Among several parameters, a high filling factor of the MR coil has proven to boost the SNR. In case of small‐volume samples, a high filling factor and thus a high SNR can be achieved through miniaturizing the MR coil. However, under certain circumstances, this can be impractical. In this paper, we present an extensive theoretical and experimental investigation of the inductively coupled LC resonator and the magnetic Lenz lens as two candidate approaches that can enhance the SNR in such circumstances. The results demonstrate that the narrow‐band LC resonator is superior in terms of SNR, while the non‐tuned nature of the Lenz lens makes it preferable in broadband applications.
- 1 July 2017
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 47B (3) , e21357
Open AccessA comparison of Lenz lenses and LC resonators for NMR signal enhancement
High signal‐to‐noise ratio (SNR) of the NMR signal has always been a key target that drives massive research effort in many fields. Among several parameters, a high filling factor of the MR coil has proven to boost the SNR. In case of small‐volume samples, a high filling factor and thus a high SNR can be achieved through miniaturizing the MR coil. However, under certain circumstances, this can be impractical. In this paper, we present an extensive theoretical and experimental investigation of the inductively coupled LC resonator and the magnetic Lenz lens as two candidate approaches that can enhance the SNR in such circumstances. The results demonstrate that the narrow‐band LC resonator is superior in terms of SNR, while the non‐tuned nature of the Lenz lens makes it preferable in broadband applications.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (21605033) , 47-48
Closed-loop pressure control of an adaptive single chamber membrane lens with integrated actuation
We introduce a closed-loop pressure control of a single chamber adaptive fluidic membrane lens with an integrated piezoelectric bending actuator. For this purpose a pressure sensor is integrated into the lens and allows for a measurement of the chamber pressure as a function of the refractive power. The linear relation between pressure and refractive power allows to eliminate the typical hysteresis effects of piezo actuators.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (21605033) , 47-48
Closed-loop pressure control of an adaptive single chamber membrane lens with integrated actuation
We introduce a closed-loop pressure control of a single chamber adaptive fluidic membrane lens with an integrated piezoelectric bending actuator. For this purpose a pressure sensor is integrated into the lens and allows for a measurement of the chamber pressure as a function of the refractive power. The linear relation between pressure and refractive power allows to eliminate the typical hysteresis effects of piezo actuators.