Hyunchul Roh

Hyunchul Roh

*This is an algorithmically generated author record based on publicly available information.

Hyunchul Roh has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Two Electronic Physical Performance Batteries by Measurement Time and Sarcopenia Classification

    by Chan Mi Park, Hee-Won Jung, Il-Young Jang, Ji Yeon Baek, Seongjun Yoon, Hyunchul Roh, Eunju Lee

    The Short Physical Performance Battery (SPPB) is a widely accepted test for measuring lower extremity function in older adults. However, there are concerns regarding the examination time required to conduct a complete SPPB consisting of three components (walking speed, chair rise, and standing balance tests) in clinical settings. We aimed to assess specific examination times for each component of the electronic Short Physical Performance Battery (eSPPB) and compare the ability of the original three-component examinations (eSPPB) and a faster, two-component examination without a balance test (electronic Quick Physical Performance Battery, eQPPB) to classify sarcopenia. The study was a retrospective, cross-sectional study which included 124 ambulatory outpatients who underwent physical performance examination at a geriatric clinic of a tertiary, academic hospital in Seoul, Korea, between December 2020 and March 2021. For eSPPB, we used a toolkit containing sensors and software (Dyphi, Daejeon, Korea) developed to measure standing balance, walking speed, and chair rise test results. Component-specific time stamps were used to log the raw data. Duration of balance examination, 5 times sit-to-stand test (5XSST), and walking speed examination were calculated. Sarcopenia was determined using the 2019 Asian Working Group for Sarcopenia (AWGS) guideline. The median age was 78 years (interquartile range, IQR: 73,82) and 77 subjects (62.1%) were female. The total mean eSPPB test time was 124.8 ± 29.0 s (balance test time 61.8 ± 12.3 s, 49.5%; gait speed test time 34.3 ± 11.9 s, 27.5%; and 5XSST time 28.7 ± 19.1 s, 23.0%). The total mean eQPPB test time was 63.0 ± 25.4 s. Based on the AWGS criteria, 34 (27.4%) patient’s results were consistent with sarcopenia. C-statistics for classifying sarcopenia were 0.83 for eSPPB and 0.85 for eQPPB (p = 0.264), while eQPPB took 49.5% less measurement time compared with eSPPB. Breakdowns of eSPPB test times were identified. Omitting balance tests may reduce test time without significantly affecting the classifying ability of eSPPB for sarcopenia.


  • Open Access

    Comparison of Human Interpretation and a Rule-Based Algorithm for Instrumented Sit-to-Stand Test

    by Hee-Won Jung, Seongjun Yoon, Ji Yeon Baek, Eunjoo Lee, Il-Young Jang, Hyunchul Roh

    Background: The five times sit-to-stand test (5STS) is one of the most commonly used tests to assess the physical performance of lower extremities. This study assessed the correlation between human interpretation (5STS(human)) and a rule-based algorithm (5STS(rule)) using instrumented 5STS with two sensors. Methods: We analyzed clinical records of 148 patients who visited the geriatric outpatient clinic of Asan Medical Center between December 2020 and March 2021 and underwent physical performance assessment using the electronic Short Physical Performance Battery (eSPPB) protocol. For STS, time-weight and time-distance curves were constructed using a loadcell and light detection and ranging (LiDAR). We manually assessed the grids of these curves to calculate 5STS(human), while 5STS(rule) used an empirical rule-based algorithm. Results: In the study population, the mean 5STS(human) and 5STS(rule) times, i.e., 12.2 +/- 0.4 and 11.4 +/- 0.4 seconds, respectively, did not differ significantly (p=0.232). Linear regression analysis showed that 5STS(human) and 5STS(rule) were positively correlated (beta=0.99, R-2=0.99). The measures also did not differ (p=0.381) in classifying sarcopenia according to the Asian Working Group Society criteria, with C-indices of 0.826 for 5STS(human) and 0.820 for 5STS(rule). Conclusion: An empirical rule-based algorithm correlated with human-interpreted 5STS and had comparable classification ability for sarcopenia.


  • Open Access

    Development and Validation of 2D-LiDAR-Based Gait Analysis Instrument and Algorithm

    by Seongjun Yoon, Hee-Won Jung, Heeyoune Jung, Keewon Kim, Suk-Koo Hong, Hyunchul Roh, Byung-Mo Oh

    Acquiring gait parameters from usual walking is important to predict clinical outcomes including life expectancy, risk of fall, and neurocognitive performance in older people. We developed a novel gait analysis tool that is small, less-intrusive and is based on two-dimensional light detection and ranging (2D-LiDAR) technology. Using an object-tracking algorithm, we conducted a validation study of the spatiotemporal tracking of ankle locations of young, healthy participants (n = 4) by comparing our tool and a stereo camera with the motion capture system as a gold standard modality. We also assessed parameters including step length, step width, cadence, and gait speed. The 2D-LiDAR system showed a much better accuracy than that of a stereo camera system, where mean absolute errors were 46.2 ± 17.8 mm and 116.3 ± 69.6 mm, respectively. Gait parameters from the 2D-LiDAR system were in good agreement with those from the motion capture system (r = 0.955 for step length, r = 0.911 for cadence). Simultaneous tracking of multiple targets by the 2D-LiDAR system was also demonstrated. The novel system might be useful in space and resource constrained clinical practice for older adults.


  • Open Access

    Development and validation of 2D-LiDAR-based gait analysis instrument and algorithm

    by Seongjun Yoon, Hee-Won Jung, Heeyoune Jung, Keewon Kim, Suk Koo Hong, Hyunchul Roh, Byung-Mo Oh

    Acquiring gait parameters from usual walking is important to predict clinical outcomes, including life expectancy, risk of fall, and neurocognitive performance, in older people. For comprehensive gait analysis, instruments such as marker-based motion analysis systems and walkways with pressure sensor arrays are necessary. Traditional instruments are bulky, complex, expensive, and intrinsically intrusive. Requirements of dedicated spaces for installation and specialized staff make it difficult to utilize traditional gait analysis instruments in most outpatient clinics. We present a novel gait analysis tool that is small, highly accurate, easy-to-use, and non-intrusive and is based on two-dimensional light detection and ranging technology. Using an object-tracking algorithm, we conducted a validation study of spatiotemporal tracking of ankle locations of subjects by comparing our tool with a gold standard modality. Our tool showed successful acquisition of gait parameters from usual walking motions and trackability with multiple targets in noisy conditions, including typical clinical environments.

  • Top Cited Papers

    Complex urban dataset with multi-level sensors from highly diverse urban environments

    by Jinyong Jeong, Younggun Cho, Young-Sik Shin, Hyunchul Roh, Ayoung Kim

    The high diversity of urban environments, at both the inter and intra levels, poses challenges for robotics research. Such challenges include discrepancies in urban features between cities and the deterioration of sensor measurements within a city. With such diversity in consideration, this paper aims to provide Light Detection and Ranging (LiDAR) and image data acquired in complex urban environments. In contrast to existing datasets, the presented dataset encapsulates various complex urban features and addresses the major issues of complex urban areas, such as unreliable and sporadic Global Positioning System (GPS) data, multi-lane roads, complex building structures, and the abundance of highly dynamic objects. This paper provides two types of LiDAR sensor data (2D and 3D) as well as navigation sensor data with commercial-level accuracy and high-level accuracy. In addition, two levels of sensor data are provided for the purpose of assisting in the complete validation of algorithms using consumer-grade sensors. A forward-facing stereo camera was utilized to capture visual images of the environment and the position information of the vehicle that was estimated through simultaneous localization mapping (SLAM) are offered as a baseline. This paper presents 3D map data generated by the SLAM algorithm in the LASer (LAS) format for a wide array of research purposes, and a file player and a data viewer have been made available via the Github webpage to allow researchers to conveniently utilize the data in a Robot Operating System (ROS) environment. The provided file player is capable of sequentially publishing large quantities of data, similar to the rosbag player. The dataset in its entirety can be found at http://irap.kaist.ac.kr/dataset .