POPeter Jan Ogrodnik

Peter Jan Ogrodnik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Jan Ogrodnik has a total of 54 co-authors. Here are the top co-authors by number of shared publications:

  • M J Goodwin

    Faculty of Computing, Engineering and Technology Staffordshire University, Stafford, Staffordshire, UK

    5 shared publications
  • Mike J. Goodwin

    Staffordshire University

    4 shared publications
  • Bing Li

    Faculty of Mechanical Engineering, Guangxi University of Science and Technology, Liuzhou, Guangxi, China

    3 shared publications
  • C I Moorcroft

    Staffordshire University, Stafford, Staffordshire, UK

    3 shared publications
  • M P Roach

    Solid Mechanics Group, School of Engineering, Staffordshire University, Stafford

    3 shared publications
  • M. J. Goodwin

    Staffordshire University School of Engineering and Advanced Technology Stafford, UK

    3 shared publications

Latest Publications

  • Tibial fractures treated with mono-lateral fixation: Principles of design and application

    by Peter Jan Ogrodnik, Peter Brian MacFarlane Thomas, Alexander Collingwood

    This paper presents the outcome of a data review of patients treated with the IOS external fixation system at the Royal Stoke University Hospital: a fixation designed to meet four requirements for external fixation proposed in this paper. Demographic data and outcome were collected and assessed. From 69 initial patients, 64 patients (55 males and 9 females) had an average age of 35.9 years. The mean time to union was 127 days. There were no incidences of malunion, or refracture post fixation removal attributable to the treatment method. In addition, in this cohort, there was no incidence of pin tract infection resulting in osteomyelitis. Of all the factors assessed the only factor to have any significant effect on healing was smoking: an average delay of 31 days. An examination of RUST (radiographic union score tibia) and modified RUST scores illustrated a potential false negative of up to 80%. Hence, this study cannot support the use of either scoring system to diagnose fracture healing. IOS external fixation was shown to be an effective method for the treatment of unstable tibial fractures. The reduction at fixation removal was shown to be very good. There was no incidence of osteomyelitis. It is, therefore, suggested that appropriately used external fixation is a viable alternative to intramedullary nailing if designed and surgically applied using four design principles outlined in this paper. Furthermore, it is proposed that external fixation be designed and applied to meet these four principles.

  • A practical, quantitative, fracture healing endpoint assessment criterion for tibial fractures treated with external fixation

    by Peter J Ogrodnik, Peter Bm Thomas

    There is a need for a quick, simple, repeatable, but quantifiable assessment tool to determine the fracture healing endpoint of tibial fractures that does not rely on the use of X-rays or on un-measured manipulation. This article presents an argument to support a ‘maximum of 1° bending’ criterion. The criterion was established from an examination of patient fracture stiffness profiles and following observations of stiffness measurements made in clinics. A proprietary mono-lateral external fixator was used to test the criterion. Sixty subjects had their fracture healing endpoint assessed using this criterion compared with the 15 N m/deg in two planes criterion, and it was deemed to be successful. The method of assessment for both mono-lateral and frame fixation (Ilizarov) is demonstrated.


  • Medium- and long-term results of high tibial osteotomy using Garches external fixator and gait analysis for dynamic correction in varus osteoarthritis of the knee

    by D. McClelland, D. Barlow, T. S. Moores, C. Wynn-Jones, D. Griffiths, P. J. Ogrodnik, P. B. M. Thomas

    In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty. Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up. At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5). HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term. Cite this article: Bone Joint J 2016;98-B:601–7.


  • Effect of journal out-of-roundness on stability of a symmetric hydrodynamic journal bearing system. Part 2: Experimental investigation

    by Wubin Xu, Peter J Ogrodnik, Bing Li, Hongxian Zhang, Shanghan Gao

    Part 2 of the study furthers the research and aims to present evidences from an experimental investigation. The work presents the experimental research with a rig for examining the effect of journal out-of-roundness on the dynamic performance of a symmetric hydrodynamic journal bearing system. Four shafts with different magnitudes of journal out-of-roundness were fabricated for the experiment. The test rig was equipped with a date logging system to collect and process all signals provided by the displacement probes and the thermocouples. The onset speed of oil film instability was determined by analysing the spectrums of the journal vibrations. The experiments show a notable double-synchronous frequency vibration component incurred by the journal out-of-roundness, which makes the system behave as oil whirling but the mechanism is different. The results also coincide with the theoretical calculations presented in Part 1 of the study, which validates that the journal out-of-roundness may increase the overall system stability when the dimensionless out-of-roundness is below 0.4, but vibration levels increase. The study can help engineers to choose reasonable tolerances or enable systems with certain manufacturing tolerances to operate within a more stable range.


  • Effect of journal out-of-roundness on stability of a symmetric hydrodynamic journal bearing system. Part 1: Theoretical analysis

    by Wubin Xu, Peter J Ogrodnik, Bing Li, Hongxian Zhang, Shanghan Gao

    The study examines the effect of journal out-of-roundness on the dynamic performance of rotating machines supported by oil film bearings. A general model of a symmetric hydrodynamic journal bearing system allowing for journal out-of-roundness is presented. The results show that the journal out-of-roundness influences the oil film thickness and further influences the dynamic characteristics of the system. The journal out-of-roundness may incur an additional vibration component when the system operates. The amplitude of this vibration component is dependent upon the magnitude of the journal out-of-roundness, while the frequency of which is an integral multiple of the synchronous vibration frequency, depending upon the profile of journal out-of-roundness. Although journal out-of-roundness may increase overall system stability, when dimensionless out-of-roundness is below 0.2, there is little effect; between 0.2 and 0.4, stability is improved but vibration levels are high. When the dimensionless journal out-of-roundness is larger than 0.5, the theoretical analysis shows much uncertainty on the system stability and the boundary of oil film instability is not very clear, this needs further examination from both theoretical and experimental evidences. The system designer should balance between the stability and the vibration level at the design stage.


  • A multidirectional fracture stiffness model to determine the principal stiffness properties of a healing human tibia

    by Peter J Ogrodnik, Peter Bm Thomas, Christopher I Moorcroft, Khaja N Mohammed

    A model for the stiffness of a fractured human tibia has been developed. The model is based on Mohr’s circle of inertia and relies on tibial fracture stiffness being measured in a number of planes. Using in vitro data, it has been shown that this model can be used to identify the principal stiffness values and their associated planes. It has also been shown that only 4/5 independent measurements are required to generate good correlation between experimental data and fitted data. Initial in vivo experiments show that this model transfers from the laboratory to clinical practice. The model illustrated that the maximum plane for a complete tibia is about 12°–14° relative to anterior–posterior, which correlates with previous publications. It is postulated that the model can be used for further in vitro studies to confirm the most common angle of the minimum stiffness plane. The knowledge of this angle may help orthopaedic surgeons to better assess fracture stiffness and may be the starting point for further discussion about the current minimum value of 15 N m/°.


  • Open Access

    The Effects of Laser Marking and Symbol Etching on the Fatigue Life of Medical Devices

    by P. J. Ogrodnik, C. I. Moorcroft, P. Wardle

    This paper examines the question;“ does permanent laser marking affect the mechanical performance of a metallic medical component?” The literature review revealed the surprising fact that very little has been presented or studied even though intuition suggests that its effect could be detrimental to a component's fatigue life. A brief investigation of laser marking suggests that defects greater than 25 μm are possible. A theoretical investigation further suggests that this is unlikely to cause issues with relation to fast fracture but is highly likely to cause fatigue life issues. An experimental investigation confirmed that laser marking reduced the fatigue life of a component. This combination of lines of evidence suggests, strongly, that positioning of laser marking is highly critical and should not be left to chance. It is further suggested that medical device designers, especially those related to orthopaedic implants, should consider the position of laser marking in the design process. They should ensure that it is in an area of low stress amplitude. They should also ensure that they investigate worst-case scenarios when considering the stress environment; this, however, may not be straightforward.


  • Comparison of Effects of Dimensional Manufacturing Tolerances and Journal Out-of-Roundness on Stability of Hydrodynamic Journal Bearing System

    by Wu Bin Xu, De Jian Zhou, Peter Ogrodnik, Mike Goodwin

    The manufacturing tolerances of a hydrodynamic journal bearing system are inevitable in manufacturing process. To examine and understand the effect of manufacturing tolerances on the system stability can help engineers to confidently choose reasonable tolerances at design stage. This study presented a theoretical analysis method to determine and compare the effects of dimensional manufacturing tolerances and journal out-of-roundness on system stability by Taguchi method. The results show that the journal out-of-roundness has the most significant effect on the system stability and the journal out-of-roundness appears to stabilize the system. The authors suggest that both dimensional manufacturing tolerances and journal roundness should be taken into account in the design of cylindrical journal bearings.

  • The effects of dimensional manufacturing tolerances on stability of a symmetric hydrodynamic journal bearing rotor system – an experimental investigation

    by P J Ogrodnik, W Xu, M J Goodwin, G A Bancroft

    The importance of gross dimensions on the design and operation of hydrodynamic journal bearing system are widely understood, however, the effects of manufacturing tolerances have only been macroscopically analysed. Building on previous theoretical analyses, an experimental investigation on the effect of dimensional manufacturing tolerances is presented. Importantly, the study looks at individual effects and combined effects. The experimental data suggested that the error created by manufacturing tolerances in estimating the onset of oil film instability can be as much as ±20 per cent, depending on the steady state operating position. This finding shows that in order to minimize the effect of manufacturing tolerances on system stability, the hydrodynamic journal bearing system should be designed to operate at a modified Sommerfeld number greater than 0.1, where the effects of manufacturing tolerances on system stability are negligible.