Jonathan D. Plasencia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jonathan D. Plasencia has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- David Frakes
Arizona State University, Tempe, AZ
2 shared publications - Stephen G. Pophal
Phoenix Children's Hospital, Phoenix, AZ, USA
2 shared publications - Steven D. Zangwill
Division of Cardiology Phoenix Children's Hospital Phoenix Arizona USA
2 shared publications - Alex McLaren
Department of Orthopaedic Surgery, University of Arizona College of Medicine-Phoenix, Phoenix, Arizona
1 shared publication - Alia Dani
Department of Cardiothoracic Surgery Cincinnati Children's Hospital Medical Center Cincinnati Ohio USA
1 shared publication Angela Lorts
Cincinnati Childrens Hosp Med Ctr, Inst Heart, Cincinnati, OH USA
1 shared publication
Latest Publications
- 17 June 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (11) , 1581-1589
Comparing donor and recipient total cardiac volume predicts risk of short-term adverse outcomes following heart transplantation
- 17 June 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (11) , 1581-1589
Comparing donor and recipient total cardiac volume predicts risk of short-term adverse outcomes following heart transplantation
- 23 February 2020
- Published by Wiley in Clinical Transplantation
- Vol. 34 (5) , e13843
Volumetrics and fit assessments for donor to recipient size matching in pediatric heart transplantation: Is it time for a new paradigm?
Pediatric heart transplant patients face the highest waitlist mortality in solid organ transplantation. Given the relatively fixed number of donor organs becoming available each year, improving donor organ utilization could potentially have significant impact on reducing waitlist mortality. Donor to recipient weight ratio has historically been used to identify suitable donors; however, this method does not take into account the potential for significant variance in heart size due to complex congenital heart disease or underlying cardiomyopathy. We believe, based on our experience to date, that donor matching based upon weight ratios should be augmented by improved methodologies that provide a more accurate assessment of heart volumes. Herein we describe the rationale for these methodologies and our single‐center experience using volumetrics as an alternative for donor fit assessments.
- 23 February 2020
- Published by Wiley in Clinical Transplantation
- Vol. 34 (5) , e13843
Volumetrics and fit assessments for donor to recipient size matching in pediatric heart transplantation: Is it time for a new paradigm?
Pediatric heart transplant patients face the highest waitlist mortality in solid organ transplantation. Given the relatively fixed number of donor organs becoming available each year, improving donor organ utilization could potentially have significant impact on reducing waitlist mortality. Donor to recipient weight ratio has historically been used to identify suitable donors; however, this method does not take into account the potential for significant variance in heart size due to complex congenital heart disease or underlying cardiomyopathy. We believe, based on our experience to date, that donor matching based upon weight ratios should be augmented by improved methodologies that provide a more accurate assessment of heart volumes. Herein we describe the rationale for these methodologies and our single‐center experience using volumetrics as an alternative for donor fit assessments.
- 24 September 2018
- Published by Wiley in Pediatric Transplantation
- Vol. 22 (8) , e13290
Alternative methods for virtual heart transplant—Size matching for pediatric heart transplantation with and without donor medical images available
Background: Listed pediatric heart transplant patients have the highest solid‐organ waitlist mortality rate. The donor‐recipient body weight (DRBW) ratio is the clinical standard for allograft size matching but may unnecessarily limit a patient's donor pool. To overcome DRBW ratio limitations, two methods of performing virtual heart transplant fit assessments were developed that account for patient‐specific nuances. Method 1 uses an allograft total cardiac volume (TCV) prediction model informed by patient data wherein a matched allograft 3‐D reconstruction is selected from a virtual library for assessment. Method 2 uses donor images for a direct virtual transplant assessment.Methods: Assessments were performed in medical image reconstruction software. The allograft model was developed using allometric/isometric scaling assumptions and cross‐validation.Results: The final predictive model included gender, height, and weight. The 25th‐, 50th‐, and 75th‐percentiles for TCV percentage errors were −13% (over‐prediction), −1%, and 8% (under‐prediction), respectively. Two examples illustrating the potential of virtual assessments are presented.Conclusion: Transplant centers can apply these methods to perform their virtual assessments using existing technology. These techniques have potential to improve organ allocation. With additional experience and refinement, virtual transplants may become standard of care for determining suitability of donor organ size for an identified recipient.
- 24 September 2018
- Published by Wiley in Pediatric Transplantation
- Vol. 22 (8) , e13290
Alternative methods for virtual heart transplant—Size matching for pediatric heart transplantation with and without donor medical images available
Background: Listed pediatric heart transplant patients have the highest solid‐organ waitlist mortality rate. The donor‐recipient body weight (DRBW) ratio is the clinical standard for allograft size matching but may unnecessarily limit a patient's donor pool. To overcome DRBW ratio limitations, two methods of performing virtual heart transplant fit assessments were developed that account for patient‐specific nuances. Method 1 uses an allograft total cardiac volume (TCV) prediction model informed by patient data wherein a matched allograft 3‐D reconstruction is selected from a virtual library for assessment. Method 2 uses donor images for a direct virtual transplant assessment.Methods: Assessments were performed in medical image reconstruction software. The allograft model was developed using allometric/isometric scaling assumptions and cross‐validation.Results: The final predictive model included gender, height, and weight. The 25th‐, 50th‐, and 75th‐percentiles for TCV percentage errors were −13% (over‐prediction), −1%, and 8% (under‐prediction), respectively. Two examples illustrating the potential of virtual assessments are presented.Conclusion: Transplant centers can apply these methods to perform their virtual assessments using existing technology. These techniques have potential to improve organ allocation. With additional experience and refinement, virtual transplants may become standard of care for determining suitability of donor organ size for an identified recipient.
- Open Access
- 1 January 2018
- Published by Elsevier in NeuroImage: Clinical
- Vol. 18, 1017
Corrigendum to “Structural alterations of the brainstem in migraine” (Neuroimage Clin. 2017; 13: 223–227)
- 1 January 2018
- Published by Elsevier in NeuroImage: Clinical
- Vol. 18, 1017
Open AccessCorrigendum to “Structural alterations of the brainstem in migraine” (Neuroimage Clin. 2017; 13: 223–227)
- Open Access
- 24 April 2013
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2013, 1-12
Spatiotemporal Quantification of Local Drug Delivery Using MRI
Controlled release formulations for local, in vivo drug delivery are of growing interest to device manufacturers, research scientists, and clinicians; however, most research characterizing controlled release formulations occurs in vitro because the spatial and temporal distribution of drug delivery is difficult to measure in vivo. In this work, in vivo magnetic resonance imaging (MRI) of local drug delivery was performed to visualize and quantify the time resolved distribution of MRI contrast agents. Three-dimensional maps (generated from -weighted images with varied ) were processed using noise-reducing filtering. A segmented region of contrast, from a thresholded image, was converted to concentration maps using the equation , where and are the precontrast and postcontrast map values, respectively. In this technique, a uniform estimated value for was used. Error estimations were performed for each step. The practical usefulness of this method was assessed using comparisons between devices located in different locations both with and without contrast. The method using a uniform , requiring no registration of pre- and postcontrast image volumes, was compared to a method using either affine or deformation registrations.
- 24 April 2013
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2013, 1-12
Open AccessSpatiotemporal Quantification of Local Drug Delivery Using MRI
Controlled release formulations for local, in vivo drug delivery are of growing interest to device manufacturers, research scientists, and clinicians; however, most research characterizing controlled release formulations occurs in vitro because the spatial and temporal distribution of drug delivery is difficult to measure in vivo. In this work, in vivo magnetic resonance imaging (MRI) of local drug delivery was performed to visualize and quantify the time resolved distribution of MRI contrast agents. Three-dimensional maps (generated from -weighted images with varied ) were processed using noise-reducing filtering. A segmented region of contrast, from a thresholded image, was converted to concentration maps using the equation , where and are the precontrast and postcontrast map values, respectively. In this technique, a uniform estimated value for was used. Error estimations were performed for each step. The practical usefulness of this method was assessed using comparisons between devices located in different locations both with and without contrast. The method using a uniform , requiring no registration of pre- and postcontrast image volumes, was compared to a method using either affine or deformation registrations.