Pengling Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pengling Ren has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Rui Wang
3 shared publicationsYawen Liu
3 shared publicationsZhenchang Wang
3 shared publications- Zhenchang Wang
Precision and Intelligence Medical Imaging Lab, Beijing Friendship Hospital, Capital Medical University, Beijing, China
3 shared publications Fengxia Yu
2 shared publicationsHaijun Niu
School of Biological Science and Medical Engineering, Beihang University, 100191, People’s Republic of China
2 shared publications
Latest Publications
- Open Access
- 23 January 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14 (1) , e79389
Two-Minute Deep Learning–Powered Brain Quantitative Mapping: Accelerating Clinical Imaging With Synthetic Magnetic Resonance Imaging
Background: Quantitative magnetic resonance imaging (MRI) is an advanced technique that can map the physical properties (T1, T2, and proton density [PD]) of different tissues, offering crucial insights for disease diagnosis. Nonetheless, the practical application of this technology is indeed constrained by several factors, with the most notable being the protracted scanning duration. Objective: This study aimed to explore whether deep learning (DL)–based superresolution reconstruction of ultrafast whole brain synthetic MRI can obtain quantitative T1/T2/PD maps that are closely approximated to those from routine clinical scans, while substantially shortening scan time and preserving diagnostic image quality. Methods: A total of 151 healthy adults and 7 individuals with different pathologies were prospectively enrolled. Each individual was examined twice on a 3.0T scanner using routine and fast synthetic MRI protocols. The routine scans (acquisition matrix: 320×256) were interpolated to 512 by 512 for clinical display and served as reference images. The fast scans (acquisition matrix: 192×128) were preprocessed to 256 by 256 and used as inputs to a superresolution generative adversarial network (SRGAN), which reconstructed them to the same 512 by 512 interpolated resolution as the reference. For each quantitative chart, 120 (75.95%) healthy individuals’ images were used for training, and 38 (24.05%) individuals’ images (healthy individuals: n=31, 19.62%; patients: n=7, 4.43%) were used for testing. Agreement was assessed with a paired t test, two 1-sided tests, Bland-Altman analysis, and coefficients of variation. Results: DL reconstructed and reference T1/T2/PD values were strongly correlated (T1: R ²=0.98; T2: R ²=0.97; and PD: R ²=0.99). The slopes of the linear regression were near 1.0 both for T1 (0.9418) and PD (0.9946), whereas T2 values were moderate, as the slope of the linear regression was 0.8057. Additionally, the average biases of T1, T2, and PD values were small (0.93%, −0.85%, and 0.31%, respectively). The intra- and intergroup coefficient of variation for most of the brain regions stayed below 5%, especially for PD values, and after DL reconstruction, it still has quantitative accuracy for lesions. Quantitative and qualitative analyses of image quality also indicate that SRGAN markedly suppressed noise and artifacts in fast acquisitions, restoring structural fidelity (structural similarity image measure) and signal fidelity (peak signal-to-noise ratio) close to the level of routine scans while substantially improving perceptual naturalness over fast scans (as measured by the naturalness image quality evaluator), although not yet matching that of routine imaging. Conclusions: SRGAN superresolution applied to ultrafast synthetic MRI yields whole brain T1, T2, and PD maps that show strong correlation with routine synthetic MRI while halving acquisition time and maintaining diagnostic image quality. Although T1 and PD values exhibit near-ideal agreement, and T2 values demonstrate a moderate systematic underestimation, this approach represents a promising step toward accelerating clinical deployment of quantitative brain imaging.
- 23 January 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14 (1) , e79389
Open AccessTwo-Minute Deep Learning–Powered Brain Quantitative Mapping: Accelerating Clinical Imaging With Synthetic Magnetic Resonance Imaging
Background: Quantitative magnetic resonance imaging (MRI) is an advanced technique that can map the physical properties (T1, T2, and proton density [PD]) of different tissues, offering crucial insights for disease diagnosis. Nonetheless, the practical application of this technology is indeed constrained by several factors, with the most notable being the protracted scanning duration. Objective: This study aimed to explore whether deep learning (DL)–based superresolution reconstruction of ultrafast whole brain synthetic MRI can obtain quantitative T1/T2/PD maps that are closely approximated to those from routine clinical scans, while substantially shortening scan time and preserving diagnostic image quality. Methods: A total of 151 healthy adults and 7 individuals with different pathologies were prospectively enrolled. Each individual was examined twice on a 3.0T scanner using routine and fast synthetic MRI protocols. The routine scans (acquisition matrix: 320×256) were interpolated to 512 by 512 for clinical display and served as reference images. The fast scans (acquisition matrix: 192×128) were preprocessed to 256 by 256 and used as inputs to a superresolution generative adversarial network (SRGAN), which reconstructed them to the same 512 by 512 interpolated resolution as the reference. For each quantitative chart, 120 (75.95%) healthy individuals’ images were used for training, and 38 (24.05%) individuals’ images (healthy individuals: n=31, 19.62%; patients: n=7, 4.43%) were used for testing. Agreement was assessed with a paired t test, two 1-sided tests, Bland-Altman analysis, and coefficients of variation. Results: DL reconstructed and reference T1/T2/PD values were strongly correlated (T1: R ²=0.98; T2: R ²=0.97; and PD: R ²=0.99). The slopes of the linear regression were near 1.0 both for T1 (0.9418) and PD (0.9946), whereas T2 values were moderate, as the slope of the linear regression was 0.8057. Additionally, the average biases of T1, T2, and PD values were small (0.93%, −0.85%, and 0.31%, respectively). The intra- and intergroup coefficient of variation for most of the brain regions stayed below 5%, especially for PD values, and after DL reconstruction, it still has quantitative accuracy for lesions. Quantitative and qualitative analyses of image quality also indicate that SRGAN markedly suppressed noise and artifacts in fast acquisitions, restoring structural fidelity (structural similarity image measure) and signal fidelity (peak signal-to-noise ratio) close to the level of routine scans while substantially improving perceptual naturalness over fast scans (as measured by the naturalness image quality evaluator), although not yet matching that of routine imaging. Conclusions: SRGAN superresolution applied to ultrafast synthetic MRI yields whole brain T1, T2, and PD maps that show strong correlation with routine synthetic MRI while halving acquisition time and maintaining diagnostic image quality. Although T1 and PD values exhibit near-ideal agreement, and T2 values demonstrate a moderate systematic underestimation, this approach represents a promising step toward accelerating clinical deployment of quantitative brain imaging.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Space: Science & Technology
- Vol. 6
Coupling between Carotid Hemodynamics and Cerebral Blood Flow During Early Simulated Microgravity
Spaceflight microgravity induces complex cerebral blood flow (CBF) alterations, which may threaten neurological health including cognitive impairment and sensorimotor disturbances of astronauts. How CBF is regulated during microgravity, especially its coupling with carotid hemodynamics, remains poorly understood. This study investigated the coupling between acute hemodynamic changes in internal carotid and vertebral arteries (ICAs and VAs) and CBF, and evaluated the potential of ultrasound-derived parameters as portable predictors for CBF under simulated microgravity using –6° head-down tilt (HDT) bed rest (BR). Thirty-three male participants underwent Doppler ultrasound assessments of ICAs and VAs, and 3-dimensional pseudocontinuous arterial spin labeling (3D-pcASL) perfusion magnetic resonance imaging (MRI), at baseline and 12 h after initiation of HDT BR. Hemodynamic parameters and regional CBF values were compared and linear regression analysis was conducted to identify predictors of changes in CBF (ΔCBF), defined as the change between 12-h HDT and baseline. Ultrasound revealed no significant changes in the bilateral ICAs. In left VA, flow velocity was significantly reduced, and right VA showed decreased resistance index, pulsatility index, and systolic/diastolic ratio. CBF significantly decreased with the most pronounced reductions in posterior circulation. ΔCBF in posterior circulation regions was associated with ultrasound parameters, and anterior circulation was predominantly predicted by baseline CBF. In summary, short-term simulated microgravity reduced CBF and this reduction was closely linked to large-vessel hemodynamic alterations, especially in the posterior circulation. These findings support the potential of ultrasound as a portable and predictive tool for early CBF assessment during spaceflight.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Space: Science & Technology
- Vol. 6
Coupling between Carotid Hemodynamics and Cerebral Blood Flow During Early Simulated Microgravity
Spaceflight microgravity induces complex cerebral blood flow (CBF) alterations, which may threaten neurological health including cognitive impairment and sensorimotor disturbances of astronauts. How CBF is regulated during microgravity, especially its coupling with carotid hemodynamics, remains poorly understood. This study investigated the coupling between acute hemodynamic changes in internal carotid and vertebral arteries (ICAs and VAs) and CBF, and evaluated the potential of ultrasound-derived parameters as portable predictors for CBF under simulated microgravity using –6° head-down tilt (HDT) bed rest (BR). Thirty-three male participants underwent Doppler ultrasound assessments of ICAs and VAs, and 3-dimensional pseudocontinuous arterial spin labeling (3D-pcASL) perfusion magnetic resonance imaging (MRI), at baseline and 12 h after initiation of HDT BR. Hemodynamic parameters and regional CBF values were compared and linear regression analysis was conducted to identify predictors of changes in CBF (ΔCBF), defined as the change between 12-h HDT and baseline. Ultrasound revealed no significant changes in the bilateral ICAs. In left VA, flow velocity was significantly reduced, and right VA showed decreased resistance index, pulsatility index, and systolic/diastolic ratio. CBF significantly decreased with the most pronounced reductions in posterior circulation. ΔCBF in posterior circulation regions was associated with ultrasound parameters, and anterior circulation was predominantly predicted by baseline CBF. In summary, short-term simulated microgravity reduced CBF and this reduction was closely linked to large-vessel hemodynamic alterations, especially in the posterior circulation. These findings support the potential of ultrasound as a portable and predictive tool for early CBF assessment during spaceflight.
- Open Access
- 20 November 2025
- Published by Elsevier in Intelligent Medicine
- Vol. 6 (1) , 5-11
Specific fine-tuned GPT-enhanced medical imaging diagnosis recommendations
- 20 November 2025
- Published by Elsevier in Intelligent Medicine
- Vol. 6 (1) , 5-11
Open AccessSpecific fine-tuned GPT-enhanced medical imaging diagnosis recommendations
- Open Access
- 26 September 2023
- Published by Elsevier in Intelligent Medicine
- Vol. 4 (1) , 10-15
Generative pretrained transformer 4: an innovative approach to facilitate value-based healthcare
- 26 September 2023
- Published by Elsevier in Intelligent Medicine
- Vol. 4 (1) , 10-15
Open AccessGenerative pretrained transformer 4: an innovative approach to facilitate value-based healthcare
- Open Access
- 17 January 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (2) , 025002
Generation of quantification maps and weighted images from synthetic magnetic resonance imaging using deep learning network
Objective. The generation of quantification maps and weighted images in synthetic MRI techniques is based on complex fitting equations. This process requires longer image generation times. The objective of this study is to evaluate the feasibility of deep learning method for fast reconstruction of synthetic MRI. Approach. A total of 44 healthy subjects were recruited and random divided into a training set (30 subjects) and a testing set (14 subjects). A multiple-dynamic, multiple-echo (MDME) sequence was used to acquire synthetic MRI images. Quantification maps (T1, T2, and proton density (PD) maps) and weighted (T1W, T2W, and T2W FLAIR) images were created with MAGiC software and then used as the ground truth images in the deep learning (DL) model. An improved multichannel U-Net structure network was trained to generate quantification maps and weighted images from raw synthetic MRI imaging data (8 module images). Quantitative evaluation was performed on quantification maps. Quantitative evaluation metrics, as well as qualitative evaluation were used in weighted image evaluation. Nonparametric Wilcoxon signed-rank tests were performed in this study. Main results. The results of quantitative evaluation show that the error between the generated quantification images and the reference images is small. For weighted images, no significant difference in overall image quality or signal-to-noise ratio was identified between DL images and synthetic images. Notably, the DL images achieved improved image contrast with T2W images, and fewer artifacts were present on DL images than synthetic images acquired by T2W FLAIR. Significance. The DL algorithm provides a promising method for image generation in synthetic MRI techniques, in which every step of the calculation can be optimized and faster, thereby simplifying the workflow of synthetic MRI techniques.
- 17 January 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (2) , 025002
Open AccessGeneration of quantification maps and weighted images from synthetic magnetic resonance imaging using deep learning network
Objective. The generation of quantification maps and weighted images in synthetic MRI techniques is based on complex fitting equations. This process requires longer image generation times. The objective of this study is to evaluate the feasibility of deep learning method for fast reconstruction of synthetic MRI. Approach. A total of 44 healthy subjects were recruited and random divided into a training set (30 subjects) and a testing set (14 subjects). A multiple-dynamic, multiple-echo (MDME) sequence was used to acquire synthetic MRI images. Quantification maps (T1, T2, and proton density (PD) maps) and weighted (T1W, T2W, and T2W FLAIR) images were created with MAGiC software and then used as the ground truth images in the deep learning (DL) model. An improved multichannel U-Net structure network was trained to generate quantification maps and weighted images from raw synthetic MRI imaging data (8 module images). Quantitative evaluation was performed on quantification maps. Quantitative evaluation metrics, as well as qualitative evaluation were used in weighted image evaluation. Nonparametric Wilcoxon signed-rank tests were performed in this study. Main results. The results of quantitative evaluation show that the error between the generated quantification images and the reference images is small. For weighted images, no significant difference in overall image quality or signal-to-noise ratio was identified between DL images and synthetic images. Notably, the DL images achieved improved image contrast with T2W images, and fewer artifacts were present on DL images than synthetic images acquired by T2W FLAIR. Significance. The DL algorithm provides a promising method for image generation in synthetic MRI techniques, in which every step of the calculation can be optimized and faster, thereby simplifying the workflow of synthetic MRI techniques.
- 1 January 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 89, 48-53
Elastic properties measurement of human enamel based on resonant ultrasound spectroscopy
- 1 January 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 89, 48-53
Elastic properties measurement of human enamel based on resonant ultrasound spectroscopy
- 1 March 2014
- Vol. 38 (2) , 110-3
[Design of mobile vital-signs monitoring system for the elderly in nursing home].
This paper proposed a mobile vital-signs monitoring system based on ZigBee localization and wireless transmission technology for the elderly in nursing home. The system can monitor the vital-signs (pulse, ECG and blood oxygen), localize human body and warn in emergency. The validity and accuracy of this system were testified by the experiments of mobile acquisition and storage of pulse. In these experiments, the measurement of pulse ranged from 50 to 170 time a minute, the mean error of which was less than 3%. The mean error of localizing was less than 4 m. And the data transmission rate was 250 kbps. The system, which effectively conducts the real-time monitoring of the health and safety situation for the elderly, has a great significance for protecting the elderly's life safety.
- 1 March 2014
- Vol. 38 (2) , 110-3
[Design of mobile vital-signs monitoring system for the elderly in nursing home].
This paper proposed a mobile vital-signs monitoring system based on ZigBee localization and wireless transmission technology for the elderly in nursing home. The system can monitor the vital-signs (pulse, ECG and blood oxygen), localize human body and warn in emergency. The validity and accuracy of this system were testified by the experiments of mobile acquisition and storage of pulse. In these experiments, the measurement of pulse ranged from 50 to 170 time a minute, the mean error of which was less than 3%. The mean error of localizing was less than 4 m. And the data transmission rate was 250 kbps. The system, which effectively conducts the real-time monitoring of the health and safety situation for the elderly, has a great significance for protecting the elderly's life safety.