Stefan Filges
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan Filges has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Anders Ståhlberg
Department of Laboratory Medicine, Sahlgrenska Center for Cancer Research, Institute of Biomedicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
14 shared publications Emiko Yamada
Department of Surgery, Boston University/Boston Medical Center, Boston, Massachusetts
4 shared publications- Tony E. Godfrey
Department of Surgery, University of Rochester Medical Center, Rochester, NY
4 shared publications Matthew Egyud
Department of Surgery, Boston University/Boston Medical Center, Boston, Massachusetts
3 shared publications- Daniel Andersson
Sahlgrenska Center for Cancer Research, Department of Laboratory Medicine, Institute of Biomedicine, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
2 shared publications - Erik Larsson
Department of Medical Biochemistry and Cell Biology, Institute of Biomedicine, The Sahlgrenska Academy, University of Gothenburg, SE-405 30 Gothenburg, Sweden
2 shared publications
Latest Publications
- Open Access
- 11 September 2026
- Published by Elsevier in The Journal of Molecular Diagnostics
The Effect of Unique Molecular Identifier Family Size Using Tumor-Informed Circulating Tumor DNA Analysis in Childhood Cancers
- 11 September 2026
- Published by Elsevier in The Journal of Molecular Diagnostics
Open AccessThe Effect of Unique Molecular Identifier Family Size Using Tumor-Informed Circulating Tumor DNA Analysis in Childhood Cancers
- Open Access
- 23 January 2026
- Published by Elsevier in The American Journal of Pathology
- Vol. 196 (4) , 1016-1027
Single-Cell Triomics Analysis of Tumor Cells Infiltrating Patient-Derived Breast Cancer Scaffolds
- 23 January 2026
- Published by Elsevier in The American Journal of Pathology
- Vol. 196 (4) , 1016-1027
Open AccessSingle-Cell Triomics Analysis of Tumor Cells Infiltrating Patient-Derived Breast Cancer Scaffolds
- Open Access
- 29 August 2022
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 68 (11) , 1425-1435
UMIErrorCorrect and UMIAnalyzer: Software for Consensus Read Generation, Error Correction, and Visualization Using Unique Molecular Identifiers
Background: Targeted sequencing using unique molecular identifiers (UMIs) enables detection of rare variant alleles in challenging applications, such as cell-free DNA analysis from liquid biopsies. Standard bioinformatics pipelines for data processing and variant calling are not adapted for deep-sequencing data containing UMIs, are inflexible, and require multistep workflows or dedicated computing resources. Methods: We developed a bioinformatics pipeline using Python and an R package for data analysis and visualization. To validate our pipeline, we analyzed cell-free DNA reference material with known mutant allele frequencies (0%, 0.125%, 0.25%, and 1%) and public data sets. Results: We developed UMIErrorCorrect, a bioinformatics pipeline for analyzing sequencing data containing UMIs. UMIErrorCorrect only requires fastq files as inputs and performs alignment, UMI clustering, error correction, and variant calling. We also provide UMIAnalyzer, a graphical user interface, for data mining, visualization, variant interpretation, and report generation. UMIAnalyzer allows the user to adjust analysis parameters and study their effect on variant calling. We demonstrated the flexibility of UMIErrorCorrect by analyzing data from 4 different targeted sequencing protocols. We also show its ability to detect different mutant allele frequencies in standardized cell-free DNA reference material. UMIErrorCorrect outperformed existing pipelines for targeted UMI sequencing data in terms of variant detection sensitivity. Conclusions: UMIErrorCorrect and UMIAnalyzer are comprehensive and customizable bioinformatics tools that can be applied to any type of library preparation protocol and enrichment chemistry using UMIs. Access to simple, generic, and open-source bioinformatics tools will facilitate the implementation of UMI-based sequencing approaches in basic research and clinical applications.
- 29 August 2022
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 68 (11) , 1425-1435
Open AccessUMIErrorCorrect and UMIAnalyzer: Software for Consensus Read Generation, Error Correction, and Visualization Using Unique Molecular Identifiers
Background: Targeted sequencing using unique molecular identifiers (UMIs) enables detection of rare variant alleles in challenging applications, such as cell-free DNA analysis from liquid biopsies. Standard bioinformatics pipelines for data processing and variant calling are not adapted for deep-sequencing data containing UMIs, are inflexible, and require multistep workflows or dedicated computing resources. Methods: We developed a bioinformatics pipeline using Python and an R package for data analysis and visualization. To validate our pipeline, we analyzed cell-free DNA reference material with known mutant allele frequencies (0%, 0.125%, 0.25%, and 1%) and public data sets. Results: We developed UMIErrorCorrect, a bioinformatics pipeline for analyzing sequencing data containing UMIs. UMIErrorCorrect only requires fastq files as inputs and performs alignment, UMI clustering, error correction, and variant calling. We also provide UMIAnalyzer, a graphical user interface, for data mining, visualization, variant interpretation, and report generation. UMIAnalyzer allows the user to adjust analysis parameters and study their effect on variant calling. We demonstrated the flexibility of UMIErrorCorrect by analyzing data from 4 different targeted sequencing protocols. We also show its ability to detect different mutant allele frequencies in standardized cell-free DNA reference material. UMIErrorCorrect outperformed existing pipelines for targeted UMI sequencing data in terms of variant detection sensitivity. Conclusions: UMIErrorCorrect and UMIAnalyzer are comprehensive and customizable bioinformatics tools that can be applied to any type of library preparation protocol and enrichment chemistry using UMIs. Access to simple, generic, and open-source bioinformatics tools will facilitate the implementation of UMI-based sequencing approaches in basic research and clinical applications.
- 25 November 2021
- Published by The R Foundation
umiAnalyzer: Tools for Analyzing Sequencing Data with Unique Molecular Identifiers
- 25 November 2021
- Published by The R Foundation
umiAnalyzer: Tools for Analyzing Sequencing Data with Unique Molecular Identifiers
- Open Access
- 30 August 2021
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 67 (10) , 1384-1394
Digital Quantification of Chemical Oligonucleotide Synthesis Errors
Background: Chemically synthesized oligonucleotides are vital to most nucleic acids-based technologies and several applications are sensitive to oligonucleotide sequence errors. However, it is challenging to identify and quantify the types and amount of errors in synthetic oligonucleotides. Methods: We applied a digital sequencing approach using unique molecular identifiers to quantify errors in chemically synthesized oligonucleotides from multiple manufacturers with different synthesis strategies, purity grades, batches, and sequence context. Results: We detected both deletions and substitutions in chemical oligonucleotide synthesis, but deletions were 7 times more common. We found that 97.2% of all analyzed oligonucleotide molecules were intact across all manufacturers and purity grades, although the number of oligonucleotide molecules with deletions ranged between 0.2% and 11.7% for different types. Different batches of otherwise identical oligonucleotide types also varied significantly, and batch effect can impact oligonucleotide quality more than purification. We observed a bias of increased deletion rates in chemically synthesized oligonucleotides toward the 5’-end for 1 out of 2 sequence configurations. We also demonstrated that the performance of sequencing assays depends on oligonucleotide quality. Conclusions: Our data demonstrate that manufacturer, synthesis strategy, purity, batch, and sequence context all contribute to errors in chemically synthesized oligonucleotides and need to be considered when choosing and evaluating oligonucleotides. High-performance oligonucleotides are essential in numerous molecular applications, including clinical diagnostics.
- 30 August 2021
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 67 (10) , 1384-1394
Open AccessDigital Quantification of Chemical Oligonucleotide Synthesis Errors
Background: Chemically synthesized oligonucleotides are vital to most nucleic acids-based technologies and several applications are sensitive to oligonucleotide sequence errors. However, it is challenging to identify and quantify the types and amount of errors in synthetic oligonucleotides. Methods: We applied a digital sequencing approach using unique molecular identifiers to quantify errors in chemically synthesized oligonucleotides from multiple manufacturers with different synthesis strategies, purity grades, batches, and sequence context. Results: We detected both deletions and substitutions in chemical oligonucleotide synthesis, but deletions were 7 times more common. We found that 97.2% of all analyzed oligonucleotide molecules were intact across all manufacturers and purity grades, although the number of oligonucleotide molecules with deletions ranged between 0.2% and 11.7% for different types. Different batches of otherwise identical oligonucleotide types also varied significantly, and batch effect can impact oligonucleotide quality more than purification. We observed a bias of increased deletion rates in chemically synthesized oligonucleotides toward the 5’-end for 1 out of 2 sequence configurations. We also demonstrated that the performance of sequencing assays depends on oligonucleotide quality. Conclusions: Our data demonstrate that manufacturer, synthesis strategy, purity, batch, and sequence context all contribute to errors in chemically synthesized oligonucleotides and need to be considered when choosing and evaluating oligonucleotides. High-performance oligonucleotides are essential in numerous molecular applications, including clinical diagnostics.
- Top Cited PapersOpen Access
- 27 August 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-10
The PEMDAC phase 2 study of pembrolizumab and entinostat in patients with metastatic uveal melanoma
Preclinical studies have suggested that epigenetic therapy could enhance immunogenicity of cancer cells. We report the results of the PEMDAC phase 2 clinical trial (n = 29; NCT02697630) where the HDAC inhibitor entinostat was combined with the PD-1 inhibitor pembrolizumab in patients with metastatic uveal melanoma (UM). The primary endpoint was objective response rate (ORR), and was met with an ORR of 14%. The clinical benefit rate at 18 weeks was 28%, median progression free survival was 2.1 months and the median overall survival was 13.4 months. Toxicities were manageable, and there were no treatment-related deaths. Objective responses and/or prolonged survival were seen in patients with BAP1 wildtype tumors, and in one patient with an iris melanoma that exhibited a UV signature. Longer survival also correlated with low baseline ctDNA levels or LDH. In conclusion, HDAC inhibition and anti-PD1 immunotherapy results in durable responses in a subset of patients with metastatic UM.Trial registration ClinicalTrials.gov registration number: NCT02697630 (registered 3 March 2016). EudraCT registration number: 2016–002114-50.
- 27 August 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-10
Top Cited PapersOpen AccessThe PEMDAC phase 2 study of pembrolizumab and entinostat in patients with metastatic uveal melanoma
Preclinical studies have suggested that epigenetic therapy could enhance immunogenicity of cancer cells. We report the results of the PEMDAC phase 2 clinical trial (n = 29; NCT02697630) where the HDAC inhibitor entinostat was combined with the PD-1 inhibitor pembrolizumab in patients with metastatic uveal melanoma (UM). The primary endpoint was objective response rate (ORR), and was met with an ORR of 14%. The clinical benefit rate at 18 weeks was 28%, median progression free survival was 2.1 months and the median overall survival was 13.4 months. Toxicities were manageable, and there were no treatment-related deaths. Objective responses and/or prolonged survival were seen in patients with BAP1 wildtype tumors, and in one patient with an iris melanoma that exhibited a UV signature. Longer survival also correlated with low baseline ctDNA levels or LDH. In conclusion, HDAC inhibition and anti-PD1 immunotherapy results in durable responses in a subset of patients with metastatic UM.Trial registration ClinicalTrials.gov registration number: NCT02697630 (registered 3 March 2016). EudraCT registration number: 2016–002114-50.
- 1 August 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (2) , 343-349
Detection of Circulating Tumor DNA in Plasma: A Potential Biomarker for Esophageal Adenocarcinoma
- 1 August 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (2) , 343-349
Detection of Circulating Tumor DNA in Plasma: A Potential Biomarker for Esophageal Adenocarcinoma
- Open Access
- 1 July 2019
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 21 (4) , 658-676
Multilaboratory Assessment of a New Reference Material for Quality Assurance of Cell-Free Tumor DNA Measurements
- 1 July 2019
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 21 (4) , 658-676
Open AccessMultilaboratory Assessment of a New Reference Material for Quality Assurance of Cell-Free Tumor DNA Measurements
- Open Access
- 5 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-7
Impact of Polymerase Fidelity on Background Error Rates in Next-Generation Sequencing with Unique Molecular Identifiers/Barcodes
Liquid biopsy and detection of tumor-associated mutations in cell-free circulating DNA often requires the ability to identify single nucleotide variants at allele frequencies below 0.1%. Standard sequencing protocols cannot achieve this level of sensitivity due to background noise from DNA damage and polymerase induced errors. Addition of unique molecular identifiers allows identification and removal of errors responsible for this background noise. Theoretically, high fidelity enzymes will also reduce error rates in barcoded NGS but this has not been thoroughly explored. We evaluated the impact of polymerase fidelity on the magnitude of error reduction at different steps of barcoded NGS library construction. We find that barcoding itself displays largest impact on error reduction, even with low fidelity polymerases. Use of high fidelity polymerases in the barcoding step of library construction further suppresses error in barcoded NGS, and allows detection of variant alleles below 0.1% allele frequency. However, the improvement in error correction is modest and is not directly proportional to polymerase fidelity. Depending on the specific application, other polymerase characteristics such as multiplexing capacity, PCR efficiency, buffer requirements and ability to amplify targets with high GC content may outweigh the relatively small additional decrease in error afforded by ultra-high fidelity polymerases.
- 5 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-7
Open AccessImpact of Polymerase Fidelity on Background Error Rates in Next-Generation Sequencing with Unique Molecular Identifiers/Barcodes
Liquid biopsy and detection of tumor-associated mutations in cell-free circulating DNA often requires the ability to identify single nucleotide variants at allele frequencies below 0.1%. Standard sequencing protocols cannot achieve this level of sensitivity due to background noise from DNA damage and polymerase induced errors. Addition of unique molecular identifiers allows identification and removal of errors responsible for this background noise. Theoretically, high fidelity enzymes will also reduce error rates in barcoded NGS but this has not been thoroughly explored. We evaluated the impact of polymerase fidelity on the magnitude of error reduction at different steps of barcoded NGS library construction. We find that barcoding itself displays largest impact on error reduction, even with low fidelity polymerases. Use of high fidelity polymerases in the barcoding step of library construction further suppresses error in barcoded NGS, and allows detection of variant alleles below 0.1% allele frequency. However, the improvement in error correction is modest and is not directly proportional to polymerase fidelity. Depending on the specific application, other polymerase characteristics such as multiplexing capacity, PCR efficiency, buffer requirements and ability to amplify targets with high GC content may outweigh the relatively small additional decrease in error afforded by ultra-high fidelity polymerases.
- Open Access
- 1 March 2019
- Published by Elsevier in Biomolecular Detection and Quantification
- Vol. 17, 100091
Corrigendum to “Considerations and quality controls when analyzing cell-free tumor DNA” [Biomol. Detect. Quantif. 17 (2019) 100078]
- 1 March 2019
- Published by Elsevier in Biomolecular Detection and Quantification
- Vol. 17, 100091
Open AccessCorrigendum to “Considerations and quality controls when analyzing cell-free tumor DNA” [Biomol. Detect. Quantif. 17 (2019) 100078]