Veysel Kutay Vurgun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Veysel Kutay Vurgun has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Basar Candemir
Department of Cardiology Ankara University Ankara Turkey
6 shared publications - Timucin Altin
Department of Cardiology Ankara University Ankara Turkey
5 shared publications - Ömer Akyürek
Department of Cardiology Ankara University Ankara Turkey
5 shared publications Huseyin Goksuluk
Cardiology Department, Ankara University School of Medicine, Ankara, Turkey
4 shared publications- Cetin Erol
Department of Cardiology, Faculty of Medicine, Ankara University, Ankara, Türkiye
3 shared publications Demet Menekse Gerede
Cardiology Department, Ankara University School of Medicine, Ankara, Turkey
2 shared publications
Latest Publications
- 3 April 2022
- Published by Taylor & Francis in Acta Cardiologica
- Vol. 78 (3) , 320-326
Comparison of frequency of silent cerebral infarction as assessed by serum neuron specific enolase in patients with non-valvular atrial fibrillation: Warfarin versus direct oral anticoagulant
Cerebral infarction in patients with atrial fibrillation (AF) may clinically vary from being silent to catastrophic. Silent cerebral infarction (SCI) is the neuronal injury in the absence of clinic...
- 3 April 2022
- Published by Taylor & Francis in Acta Cardiologica
- Vol. 78 (3) , 320-326
Comparison of frequency of silent cerebral infarction as assessed by serum neuron specific enolase in patients with non-valvular atrial fibrillation: Warfarin versus direct oral anticoagulant
Cerebral infarction in patients with atrial fibrillation (AF) may clinically vary from being silent to catastrophic. Silent cerebral infarction (SCI) is the neuronal injury in the absence of clinic...
- 11 October 2020
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (12) , 3251-3261
Clinical, electrocardiographic and electrophysiological characteristics, and catheter ablation results of left upper septal premature ventricular complexes
Background: To investigate the clinical, electrocardiographic and electrophysiological characteristics, and results of catheter ablation of left upper septal (LUS) premature ventricular complexes (PVCs) arising from the proximal left fascicular system.Methods: Thirty‐one patients who had undergone radiofrequency catheter ablation (RFCA) for idiopathic PVCs were enrolled in the study. All PVCs presented with narrow QRS complexes (<110 ms) with precordial QRS morphology of incomplete right bundle branch block type or identical to the sinus rhythm (SR) QRS morphology. RFCA was applied to the LUS area where the earliest fascicular potential (FP) was recorded during mapping.Results: The mean QRS duration during SR and PVCs were 92.3 ± 7.9 and 103.2 ± 7.3 ms, respectively. The mean fascicular potential‐ventricular interval during PVC at the target site was 32.7 ± 2.7 ms. The mean His‐ventricular (H‐V) interval during SR and PVCs were 45.1 ± 2.7 and 21.3 ± 3.6 ms, respectively. Left anterior hemiblock/left posterior hemiblock and left bundle branch block (LBBB) were observed in 16 (53.3%) and 4 (12.9%) patients after RFCA, respectively. The His to FP interval in SR and H‐V interval during PVC were found as significant markers for predicting the postablation LBBB. RFCA was acutely successful in 29 of 31 patients (93.5%) in the first procedure. Two patients had a recurrence of PVCs during follow‐up and one of them underwent a second successful ablation. The overall success rate was 90.3% (28/31) in a mean follow‐up duration of 24.3 ± 15.4 months.Conclusions: LUS‐PVCs have distinctive electrocardiographic and electrophysiologic characteristics and can be managed successfully by focal RFCA with detailed FP mapping of the left upper septum with a mild risk of left bundle branch injury.
- 11 October 2020
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (12) , 3251-3261
Clinical, electrocardiographic and electrophysiological characteristics, and catheter ablation results of left upper septal premature ventricular complexes
Background: To investigate the clinical, electrocardiographic and electrophysiological characteristics, and results of catheter ablation of left upper septal (LUS) premature ventricular complexes (PVCs) arising from the proximal left fascicular system.Methods: Thirty‐one patients who had undergone radiofrequency catheter ablation (RFCA) for idiopathic PVCs were enrolled in the study. All PVCs presented with narrow QRS complexes (<110 ms) with precordial QRS morphology of incomplete right bundle branch block type or identical to the sinus rhythm (SR) QRS morphology. RFCA was applied to the LUS area where the earliest fascicular potential (FP) was recorded during mapping.Results: The mean QRS duration during SR and PVCs were 92.3 ± 7.9 and 103.2 ± 7.3 ms, respectively. The mean fascicular potential‐ventricular interval during PVC at the target site was 32.7 ± 2.7 ms. The mean His‐ventricular (H‐V) interval during SR and PVCs were 45.1 ± 2.7 and 21.3 ± 3.6 ms, respectively. Left anterior hemiblock/left posterior hemiblock and left bundle branch block (LBBB) were observed in 16 (53.3%) and 4 (12.9%) patients after RFCA, respectively. The His to FP interval in SR and H‐V interval during PVC were found as significant markers for predicting the postablation LBBB. RFCA was acutely successful in 29 of 31 patients (93.5%) in the first procedure. Two patients had a recurrence of PVCs during follow‐up and one of them underwent a second successful ablation. The overall success rate was 90.3% (28/31) in a mean follow‐up duration of 24.3 ± 15.4 months.Conclusions: LUS‐PVCs have distinctive electrocardiographic and electrophysiologic characteristics and can be managed successfully by focal RFCA with detailed FP mapping of the left upper septum with a mild risk of left bundle branch injury.
- 1 June 2019
- Published by Elsevier in The American Journal of Cardiology
- Vol. 123 (11) , 1835-1839
Relation of Acute Decompensated Heart Failure to Silent Cerebral Infarcts in Patients With Reduced Left Ventricular Ejection Fraction
- 1 June 2019
- Published by Elsevier in The American Journal of Cardiology
- Vol. 123 (11) , 1835-1839
Relation of Acute Decompensated Heart Failure to Silent Cerebral Infarcts in Patients With Reduced Left Ventricular Ejection Fraction
- 14 July 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (9) , 1276
Extrathoracic subclavian‐axillary vein location over the first rib for pacemaker and defibrillator lead implantation
- 14 July 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (9) , 1276
Extrathoracic subclavian‐axillary vein location over the first rib for pacemaker and defibrillator lead implantation
- 13 June 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 53 (2) , 249-254
Evaluation of right ventricular pacing parameters in patients with proliferative scar
Dermal and myocardial injury results in a healing process, characterized by inflammation and fibrosis. We aimed to investigate association between proliferative scarring at the operation site and right ventricular (RV) pacing and sensing parameters, two clinical outcomes associated with impaired dermal and myocardial healing, respectively.
- 13 June 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 53 (2) , 249-254
Evaluation of right ventricular pacing parameters in patients with proliferative scar
Dermal and myocardial injury results in a healing process, characterized by inflammation and fibrosis. We aimed to investigate association between proliferative scarring at the operation site and right ventricular (RV) pacing and sensing parameters, two clinical outcomes associated with impaired dermal and myocardial healing, respectively.
- 23 May 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (8) , 927-932
Extrathoracic subclavian‐axillary vein location and morphological features over the first rib for pacemaker and defibrillator lead implantation
Background: We aimed to describe the variations of extrathoracic subclavian‐axillary vein location and its morphology over the first rib by venography in order to facilitate venous puncture using fluoroscopic landmarks without contrast venography, and evaluate the success rate of punctures, which is made with our method.Methods: Patients who had undergone de novo lead implantation with the help of prepuncture venography between 2011 and 2015 were enrolled. For detection of the segmental location of the axillary vein, the zones were defined (Zone 1: Posterior, Zone 2: Lateral, Zone 3: Medial) at the first rib by fluoroscopy. Additionally, patients, who underwent venous puncture with our method after January 2017, were evaluated in terms of puncture success.Results: Four hundred thirty‐three patients who had prepuncture contrast venography for defibrillator or pacemaker lead implantation in 2011–2015 were analyzed. The most common position of the axillary vein was found to be over zone 2 (91%) while the zone 1 location was 8.5% and the zone 3 was 0.5%. Venous valves were detected on the first rib in 98 patients. After January 2017, venous puncture using fluoroscopic landmarks was performed to 171 patients. The punctures were successfully performed over zone 2 with our method in 90.7% of the patients.Conclusions: The most common radioanatomic position of the extrathoracic subclavian‐axillary vein was observed at zone 2 according to our method and the probability of presence of venous valve over the first rib is 22%. Additionally, the success rate of puncture using fluoroscopic landmarks over zone 2 was 90.7%.
- 23 May 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (8) , 927-932
Extrathoracic subclavian‐axillary vein location and morphological features over the first rib for pacemaker and defibrillator lead implantation
Background: We aimed to describe the variations of extrathoracic subclavian‐axillary vein location and its morphology over the first rib by venography in order to facilitate venous puncture using fluoroscopic landmarks without contrast venography, and evaluate the success rate of punctures, which is made with our method.Methods: Patients who had undergone de novo lead implantation with the help of prepuncture venography between 2011 and 2015 were enrolled. For detection of the segmental location of the axillary vein, the zones were defined (Zone 1: Posterior, Zone 2: Lateral, Zone 3: Medial) at the first rib by fluoroscopy. Additionally, patients, who underwent venous puncture with our method after January 2017, were evaluated in terms of puncture success.Results: Four hundred thirty‐three patients who had prepuncture contrast venography for defibrillator or pacemaker lead implantation in 2011–2015 were analyzed. The most common position of the axillary vein was found to be over zone 2 (91%) while the zone 1 location was 8.5% and the zone 3 was 0.5%. Venous valves were detected on the first rib in 98 patients. After January 2017, venous puncture using fluoroscopic landmarks was performed to 171 patients. The punctures were successfully performed over zone 2 with our method in 90.7% of the patients.Conclusions: The most common radioanatomic position of the extrathoracic subclavian‐axillary vein was observed at zone 2 according to our method and the probability of presence of venous valve over the first rib is 22%. Additionally, the success rate of puncture using fluoroscopic landmarks over zone 2 was 90.7%.
- 10 April 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (6) , 680
Percutaneous transapical approach and transcatheter closure for ventricular tachycardia ablation
- 10 April 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (6) , 680
Percutaneous transapical approach and transcatheter closure for ventricular tachycardia ablation
- Open Access
- 1 January 2018
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 19 (2) , 148-149
Management of scar-related atrial flutter in a patient with dextrocardia, inferior vena cava interruption, and azygos continuation
- 1 January 2018
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 19 (2) , 148-149
Open AccessManagement of scar-related atrial flutter in a patient with dextrocardia, inferior vena cava interruption, and azygos continuation
- 16 November 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (3) , 334-337
Percutaneous transapical approach and transcatheter closure for ventricular tachycardia ablation
In patients with mechanical aortic and mitral valve prosthesis, left ventricular endocardial ablation via retrograde transaortic or antegrade transmitral approach carry high risk of catheter entrapment and death. In such cases, ablation can be performed via ventricular transseptal or transapical approach. Transapical approach, with the ease of catheter maneuverability and better endocardial contact, may be performed surgically or percutaneously. In this case report, we describe a patient with both aortic and mitral mechanical prosthesis who underwent ventricular tachycardia ablation via percutaneous transapical endocardial approach with the use of closure device.
- 16 November 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (3) , 334-337
Percutaneous transapical approach and transcatheter closure for ventricular tachycardia ablation
In patients with mechanical aortic and mitral valve prosthesis, left ventricular endocardial ablation via retrograde transaortic or antegrade transmitral approach carry high risk of catheter entrapment and death. In such cases, ablation can be performed via ventricular transseptal or transapical approach. Transapical approach, with the ease of catheter maneuverability and better endocardial contact, may be performed surgically or percutaneously. In this case report, we describe a patient with both aortic and mitral mechanical prosthesis who underwent ventricular tachycardia ablation via percutaneous transapical endocardial approach with the use of closure device.