Emmanuel A. Andreadis
Emmanuel A. Andreadis has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Charalampia V. Geladari
Hypertension and Cardiovascular Disease Prevention Center Athens Medical Group Psychiko Clinic Neo Psychiko Greece
8 shared publications- Epameinondas Angelopoulos
Evangelismos General Hospital
7 shared publications Vasilios Papademetriou
Department of Cardiology, Veterans Affairs and Georgetown University Medical Centers, Washington, DC, USA
3 shared publications- Vasilios Papademetriou
Georgetown University and VA Medical Center
3 shared publications Anna I. Georgantoni
Hypertension and Cardiovascular Disease Prevention Center, Evangelismos General Hospital, Athens, Greece
1 shared publicationAnnice Chung
Georgetown University and VA medical Centers, District of Columbia, Washington
1 shared publication
Latest Publications
- Open Access
- 9 May 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (10) , 1360
The Prognostic Role of Automated Office Blood Pressure Measurement in Hypertensive Patients with Chronic Kidney Disease
Background: The aim of this study was to evaluate the prognostic value of automated office blood pressure (AOBP) measurement in patients with hypertension and chronic kidney disease (CKD) stage 3–5 not on dialysis. Methods: At baseline, 140 patients were recruited, and blood pressure (BP) measurements with 3 different methods, namely, office blood pressure (OBP), AOBP, and ambulatory blood pressure measurement (ABPM), were recorded. All patients were prospectively followed for a median period of 3.4 years. The primary outcome of this study was a composite outcome of cardiovascular (CV) events (both fatal and nonfatal) or a doubling of serum creatine or progression to end-stage kidney disease (ESKD), whichever occurred first. Results: At baseline, the median age of patients was 65.2 years; 36.4% had diabetes; 21.4% had a history of CV disease; the mean of estimated glomerular filtration rate (eGFR) was 33 mL/min/1.73 m2; and the means of OBP, AOBP, and daytime ABPM were 151/84 mm Hg, 134/77 mm Hg, and 132/77 mm Hg, respectively. During the follow-up, 18 patients had a CV event, and 37 patients had a renal event. In the univariate cox regression analysis, systolic AOBP was found to be predictive of the primary outcome (HR per 1 mm Hg increase in BP, 1.019, 95% CI 1.003–1.035), and after adjustment for eGFR, smoking status, diabetes, and a history of CV disease and systolic and diastolic AOBP were also found to be predictive of the primary outcome (HR per 1 mm Hg increase in BP, 1.017, 95% CI 1.002–1.032 and 1.033, 95% CI 1.009–1.058, respectively). Conclusions: In patients with CKD, AOBP appears to be prognostic of CV risk or risk for kidney disease progression and could, therefore, be considered a reliable means for recording BP in the office setting.
- 9 May 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (10) , 1360
Open AccessThe Prognostic Role of Automated Office Blood Pressure Measurement in Hypertensive Patients with Chronic Kidney Disease
Background: The aim of this study was to evaluate the prognostic value of automated office blood pressure (AOBP) measurement in patients with hypertension and chronic kidney disease (CKD) stage 3–5 not on dialysis. Methods: At baseline, 140 patients were recruited, and blood pressure (BP) measurements with 3 different methods, namely, office blood pressure (OBP), AOBP, and ambulatory blood pressure measurement (ABPM), were recorded. All patients were prospectively followed for a median period of 3.4 years. The primary outcome of this study was a composite outcome of cardiovascular (CV) events (both fatal and nonfatal) or a doubling of serum creatine or progression to end-stage kidney disease (ESKD), whichever occurred first. Results: At baseline, the median age of patients was 65.2 years; 36.4% had diabetes; 21.4% had a history of CV disease; the mean of estimated glomerular filtration rate (eGFR) was 33 mL/min/1.73 m2; and the means of OBP, AOBP, and daytime ABPM were 151/84 mm Hg, 134/77 mm Hg, and 132/77 mm Hg, respectively. During the follow-up, 18 patients had a CV event, and 37 patients had a renal event. In the univariate cox regression analysis, systolic AOBP was found to be predictive of the primary outcome (HR per 1 mm Hg increase in BP, 1.019, 95% CI 1.003–1.035), and after adjustment for eGFR, smoking status, diabetes, and a history of CV disease and systolic and diastolic AOBP were also found to be predictive of the primary outcome (HR per 1 mm Hg increase in BP, 1.017, 95% CI 1.002–1.032 and 1.033, 95% CI 1.009–1.058, respectively). Conclusions: In patients with CKD, AOBP appears to be prognostic of CV risk or risk for kidney disease progression and could, therefore, be considered a reliable means for recording BP in the office setting.
- Open Access
- 1 July 2020
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 22 (7) , 1177-1183
Automated office blood pressure is in agreement with awake and mean 24-hour ambulatory blood pressure at the lower blood pressure range
Automated office blood pressure measurement eliminates the white coat effect and is associated with awake ambulatory blood pressure. This study examined whether automated office blood pressure values at lower limits were comparable to those of awake and mean 24-hour ambulatory blood pressure. A total of 552 patients were included in the study, involving 293 (53.1%) men and 259 (46.9%) women, with a mean age 55.0 +/- 12.5, of whom 36% were treated for hypertension. Both systolic and diastolic automated office blood pressures exhibited lower values compared to awake ambulatory blood pressure among 254 individuals with systolic automated office blood pressure <130 mm Hg (119 +/- 8 mm Hg vs 125 +/- 11 mm Hg,P < .0001 and 75 +/- 9 mm Hg vs 79 +/- 9 mm Hg,P < .0001 for systolic and diastolic BPs, respectively). Furthermore, the comparison of systolic automated office blood pressure to the mean 24-hour ambulatory blood pressure levels also showed lower values (119 +/- 8 vs 121 +/- 10,P = .007), whereas the diastolic automated office blood pressure measurements were similar to 24-hour ambulatory blood pressure values. Our findings show that when automated office blood pressure readings express values <130/80 mm Hg in repeated office visits, further investigation should be performed only when masked hypertension is suspected; otherwise, higher automated office blood pressure values could be used for the diagnosis of uncontrolled hypertension, especially in individuals with organ damage.
- 1 July 2020
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 22 (7) , 1177-1183
Open AccessAutomated office blood pressure is in agreement with awake and mean 24-hour ambulatory blood pressure at the lower blood pressure range
Automated office blood pressure measurement eliminates the white coat effect and is associated with awake ambulatory blood pressure. This study examined whether automated office blood pressure values at lower limits were comparable to those of awake and mean 24-hour ambulatory blood pressure. A total of 552 patients were included in the study, involving 293 (53.1%) men and 259 (46.9%) women, with a mean age 55.0 +/- 12.5, of whom 36% were treated for hypertension. Both systolic and diastolic automated office blood pressures exhibited lower values compared to awake ambulatory blood pressure among 254 individuals with systolic automated office blood pressure <130 mm Hg (119 +/- 8 mm Hg vs 125 +/- 11 mm Hg,P < .0001 and 75 +/- 9 mm Hg vs 79 +/- 9 mm Hg,P < .0001 for systolic and diastolic BPs, respectively). Furthermore, the comparison of systolic automated office blood pressure to the mean 24-hour ambulatory blood pressure levels also showed lower values (119 +/- 8 vs 121 +/- 10,P = .007), whereas the diastolic automated office blood pressure measurements were similar to 24-hour ambulatory blood pressure values. Our findings show that when automated office blood pressure readings express values <130/80 mm Hg in repeated office visits, further investigation should be performed only when masked hypertension is suspected; otherwise, higher automated office blood pressure values could be used for the diagnosis of uncontrolled hypertension, especially in individuals with organ damage.
- Open Access
- 28 February 2020
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 22 (4) , 555-559
The optimal use of automated office blood pressure measurement in clinical practice
This evidence‐based article endorses the use of automated office blood pressure (AOBP). AOBP is the most favorable office blood pressure (BP) measuring technique as it provides accurate readings with 3‐15 mm Hg lower values than the casual conventional office measurements with auscultatory or semi‐automated oscillometric devices and relates closely to awake ABP readings. The AOBP technique seems to be superior to conventional office BP in predicting hypertension‐mediated organ damage and appears to be equally reliable to awake ABP in the prediction of cardiovascular (CV) disease. AOBP readings should be obtained either unattended, with the patient alone in the examination room, or attended with the presence of personnel in the room but with no talking to the patient, although this recommendation is not frequently followed in routine clinical practice. To optimize office BP readings, the type of device, the rest period before AOBP measurements (preceding rest), and the time intervals between measurements were evaluated. As AOBP readings have the advantage of removing many confounding factors, the authors propose to perform measurements with a preceding rest in all patients at the initial visit; if AOBP readings remain <130 mm Hg in subsequent visits, measurements could be accepted, otherwise, if are higher, patients should be evaluated by out‐of‐office BP measurements.
- 28 February 2020
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 22 (4) , 555-559
Open AccessThe optimal use of automated office blood pressure measurement in clinical practice
This evidence‐based article endorses the use of automated office blood pressure (AOBP). AOBP is the most favorable office blood pressure (BP) measuring technique as it provides accurate readings with 3‐15 mm Hg lower values than the casual conventional office measurements with auscultatory or semi‐automated oscillometric devices and relates closely to awake ABP readings. The AOBP technique seems to be superior to conventional office BP in predicting hypertension‐mediated organ damage and appears to be equally reliable to awake ABP in the prediction of cardiovascular (CV) disease. AOBP readings should be obtained either unattended, with the patient alone in the examination room, or attended with the presence of personnel in the room but with no talking to the patient, although this recommendation is not frequently followed in routine clinical practice. To optimize office BP readings, the type of device, the rest period before AOBP measurements (preceding rest), and the time intervals between measurements were evaluated. As AOBP readings have the advantage of removing many confounding factors, the authors propose to perform measurements with a preceding rest in all patients at the initial visit; if AOBP readings remain <130 mm Hg in subsequent visits, measurements could be accepted, otherwise, if are higher, patients should be evaluated by out‐of‐office BP measurements.
- Open Access
- 1 December 2019
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 22 (1) , 32-38
Automated office blood pressure measurements obtained with and without preceding rest are associated with awake ambulatory blood pressure
Automated office blood pressure (AOBP) measurement, attended or unattended, eliminates the white coat effect (WCE) showing a strong association with awake ambulatory blood pressure (ABP). This study examined the difference in AOBP readings, with and without 5 minutes of rest prior to three readings recorded at 1‐min intervals. Cross‐sectional data from 100 randomized selected hypertensives, 61 men and 39 women, with a mean age of 52.2 ± 10.8 years, 82% treated, were analyzed. The mean systolic AOBP values without preceding rest were 127.0 ± 18.2 mm Hg, and the mean systolic AOBP values with 5 minutes of preceding rest were 125.7 ± 17.9 mm Hg (P = .05). A significant order effect was observed for the mean systolic BP values when AOBP without 5 minutes of preceding rest was performed as the first measurement (130.0 ± 17.7 vs 126.5 ± 16.2, P = .008). When we used a target systolic AOBP ≥ 130 mm Hg, awake ABP yielded lower readings, while at a target systolic AOBP value of < 130 mm Hg higher awake ABP values were obtained. Our findings indicate that systolic AOBP can be initially checked without any preceding rest and if readings are normal can be accepted. Otherwise, when AOBP is ≥ 130 mm Hg, measurements should be rechecked with 5 minutes of rest.
- 1 December 2019
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 22 (1) , 32-38
Open AccessAutomated office blood pressure measurements obtained with and without preceding rest are associated with awake ambulatory blood pressure
Automated office blood pressure (AOBP) measurement, attended or unattended, eliminates the white coat effect (WCE) showing a strong association with awake ambulatory blood pressure (ABP). This study examined the difference in AOBP readings, with and without 5 minutes of rest prior to three readings recorded at 1‐min intervals. Cross‐sectional data from 100 randomized selected hypertensives, 61 men and 39 women, with a mean age of 52.2 ± 10.8 years, 82% treated, were analyzed. The mean systolic AOBP values without preceding rest were 127.0 ± 18.2 mm Hg, and the mean systolic AOBP values with 5 minutes of preceding rest were 125.7 ± 17.9 mm Hg (P = .05). A significant order effect was observed for the mean systolic BP values when AOBP without 5 minutes of preceding rest was performed as the first measurement (130.0 ± 17.7 vs 126.5 ± 16.2, P = .008). When we used a target systolic AOBP ≥ 130 mm Hg, awake ABP yielded lower readings, while at a target systolic AOBP value of < 130 mm Hg higher awake ABP values were obtained. Our findings indicate that systolic AOBP can be initially checked without any preceding rest and if readings are normal can be accepted. Otherwise, when AOBP is ≥ 130 mm Hg, measurements should be rechecked with 5 minutes of rest.
- 9 July 2019
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 26 (4) , 293-303
Attended Versus Unattended Automated Office Blood Pressure: A Systematic Review and Meta-analysis
Automated office blood pressure (AOBP) has been proposed for blood pressure (BP) assessment in the office because it shows a strong association with the awake ambulatory BP. However, it remains unknown whether the presence or absence of an observer modulates AOBP readings.
- 9 July 2019
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 26 (4) , 293-303
Attended Versus Unattended Automated Office Blood Pressure: A Systematic Review and Meta-analysis
Automated office blood pressure (AOBP) has been proposed for blood pressure (BP) assessment in the office because it shows a strong association with the awake ambulatory BP. However, it remains unknown whether the presence or absence of an observer modulates AOBP readings.
- 15 April 2019
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 26 (3) , 209-215
Morning Surge and Peak Morning Ambulatory Blood Pressure Versus Automated Office Blood Pressure in Predicting Cardiovascular Disease
Automated office blood pressure (AOBP) has been recently shown to predict equally well to ambulatory blood pressure (ABP), conventional office blood pressure (OBP) and home blood pressure (HBP), cardiovascular (CV) events among hypertensives.
- 15 April 2019
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 26 (3) , 209-215
Morning Surge and Peak Morning Ambulatory Blood Pressure Versus Automated Office Blood Pressure in Predicting Cardiovascular Disease
Automated office blood pressure (AOBP) has been recently shown to predict equally well to ambulatory blood pressure (ABP), conventional office blood pressure (OBP) and home blood pressure (HBP), cardiovascular (CV) events among hypertensives.
- 14 December 2018
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 21 (2) , 156-158
The clinical value of automated office blood pressure: What is the latest evidence on attended vs unattended automated readings in clinical practice?
- 14 December 2018
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 21 (2) , 156-158
The clinical value of automated office blood pressure: What is the latest evidence on attended vs unattended automated readings in clinical practice?
- Open Access
- 1 October 2018
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 20 (10) , 1411-1416
Unobserved automated office BP is similar to other clinic BP measurements: A prospective randomized study
Results of the SPRINT study have been disputed, based on the assumption that unattended BP measurements do not correlate with usual BP measurements. In this study, the authors investigated the correlation of unattended SPRINT‐like measurements with other conventional measurements. All BP measurements were taken with the patient seated in a comfortable chair with the legs uncrossed and not speaking during the procedure. For the purpose of this study, sixty‐five patients, mostly male (93%), were recruited from our hypertension clinic and all were on antihypertensive medication (av 3.0 ± 1.1). Patients were at high cardiovascular risk with high rates of comorbidities, av age 68 ± 12 years, 49% with diabetes, 34% with mild CKD (CKD 1‐3, average eGFR 55.0 ± 13 mL/min/1.73 m2), and 20% with history of stable coronary artery disease. All BP measurements were similar with no statistically significant difference (one‐way ANOVA,P = 0.621). Compared to unattended SPRINT BP values (139.77 ± 19.22/75.42 ± 11.72 mm Hg), the clinic BP measurements were numerically slightly higher but with a NSPvalue (P = 0.163). Similarly, unattended BP measurements were similar to values taken by the clinic physician. In a smaller cohort of 11 patients, the authors compared unobserved vs observed SPRINT‐like BP measurements, and in 13 patients, the authors compared unobserved SPRINT‐like BP measurements to average home BP measurements (Table 3). There were no significant differences between any of the subgroups (one‐way ANOVA,P = 0.816 for systolic andP = 0.803 for diastolic). The authors conclude that unattended BP measurements taken (the SPRINT way) are similar to other conventional office blood pressure measurements.
- 1 October 2018
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 20 (10) , 1411-1416
Open AccessUnobserved automated office BP is similar to other clinic BP measurements: A prospective randomized study
Results of the SPRINT study have been disputed, based on the assumption that unattended BP measurements do not correlate with usual BP measurements. In this study, the authors investigated the correlation of unattended SPRINT‐like measurements with other conventional measurements. All BP measurements were taken with the patient seated in a comfortable chair with the legs uncrossed and not speaking during the procedure. For the purpose of this study, sixty‐five patients, mostly male (93%), were recruited from our hypertension clinic and all were on antihypertensive medication (av 3.0 ± 1.1). Patients were at high cardiovascular risk with high rates of comorbidities, av age 68 ± 12 years, 49% with diabetes, 34% with mild CKD (CKD 1‐3, average eGFR 55.0 ± 13 mL/min/1.73 m2), and 20% with history of stable coronary artery disease. All BP measurements were similar with no statistically significant difference (one‐way ANOVA,P = 0.621). Compared to unattended SPRINT BP values (139.77 ± 19.22/75.42 ± 11.72 mm Hg), the clinic BP measurements were numerically slightly higher but with a NSPvalue (P = 0.163). Similarly, unattended BP measurements were similar to values taken by the clinic physician. In a smaller cohort of 11 patients, the authors compared unobserved vs observed SPRINT‐like BP measurements, and in 13 patients, the authors compared unobserved SPRINT‐like BP measurements to average home BP measurements (Table 3). There were no significant differences between any of the subgroups (one‐way ANOVA,P = 0.816 for systolic andP = 0.803 for diastolic). The authors conclude that unattended BP measurements taken (the SPRINT way) are similar to other conventional office blood pressure measurements.
- Open Access
- 17 April 2018
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 7 (8)
Attended and Unattended Automated Office Blood Pressure Measurements Have Better Agreement With Ambulatory Monitoring Than Conventional Office Readings
Background: Automated office blood pressure (AOBP) measurement is superior to conventional office blood pressure (OBP) because it eliminates the “white coat effect” and shows a strong association with ambulatory blood pressure. Methods and Results: We conducted a cross‐sectional study in 146 participants with office hypertension, and we compared AOBP readings, taken with or without the presence of study personnel, before and after the conventional office readings to determine whether their variation in blood pressure showed a difference in blood pressure values. We also compared AOBP measurements with daytime ambulatory blood pressure monitoring and conventional office readings. The mean age of the studied population was 56±12 years, and 53.4% of participants were male. Bland–Altman analysis revealed a bias (ie, mean of the differences) of 0.6±6 mm Hg systolic for attended AOBP compared with unattended and 1.4±6 and 0.1±6 mm Hg bias for attended compared with unattended systolic AOBP when measurements were performed before and after conventional readings, respectively. A small bias was observed when unattended and attended systolic AOBP measurements were compared with daytime ambulatory blood pressure monitoring (1.3±13 and 0.6±13 mm Hg, respectively). Biases were higher for conventional OBP readings compared with unattended AOBP (−5.6±15 mm Hg for unattended AOBP and oscillometric OBP measured by a physician, −6.8±14 mm Hg for unattended AOBP and oscillometric OBP measured by a nurse, and −2.1±12 mm Hg for unattended AOBP and auscultatory OBP measured by a second physician). Conclusions: Our findings showed that independent of the presence or absence of medical staff, AOBP readings revealed similar values that were closer to daytime ambulatory blood pressure monitoring than conventional office readings, further supporting the use of AOBP in the clinical setting.
- 17 April 2018
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 7 (8)
Open AccessAttended and Unattended Automated Office Blood Pressure Measurements Have Better Agreement With Ambulatory Monitoring Than Conventional Office Readings
Background: Automated office blood pressure (AOBP) measurement is superior to conventional office blood pressure (OBP) because it eliminates the “white coat effect” and shows a strong association with ambulatory blood pressure. Methods and Results: We conducted a cross‐sectional study in 146 participants with office hypertension, and we compared AOBP readings, taken with or without the presence of study personnel, before and after the conventional office readings to determine whether their variation in blood pressure showed a difference in blood pressure values. We also compared AOBP measurements with daytime ambulatory blood pressure monitoring and conventional office readings. The mean age of the studied population was 56±12 years, and 53.4% of participants were male. Bland–Altman analysis revealed a bias (ie, mean of the differences) of 0.6±6 mm Hg systolic for attended AOBP compared with unattended and 1.4±6 and 0.1±6 mm Hg bias for attended compared with unattended systolic AOBP when measurements were performed before and after conventional readings, respectively. A small bias was observed when unattended and attended systolic AOBP measurements were compared with daytime ambulatory blood pressure monitoring (1.3±13 and 0.6±13 mm Hg, respectively). Biases were higher for conventional OBP readings compared with unattended AOBP (−5.6±15 mm Hg for unattended AOBP and oscillometric OBP measured by a physician, −6.8±14 mm Hg for unattended AOBP and oscillometric OBP measured by a nurse, and −2.1±12 mm Hg for unattended AOBP and auscultatory OBP measured by a second physician). Conclusions: Our findings showed that independent of the presence or absence of medical staff, AOBP readings revealed similar values that were closer to daytime ambulatory blood pressure monitoring than conventional office readings, further supporting the use of AOBP in the clinical setting.
- 1 January 2018
- Published by IMR Press in Frontiers in Bioscience-Scholar
- Vol. 10 (2) , 276-284
Hypertension and atrial fibrillation a bench to bedside perspective
Atrial Fibrillation (AF) is the most common cardiac arrhythmia in clinical practice and its prevalence increases markedly with advancing age, worldwide. Almost every primary care physician, internist, or cardiologist, has dealt with stroke or with other complications of AF. Still, its management remains a hot issue for clinicians and the debate over which treatment strategy is the best is ongoing. Moreover, AF increases significantly the total cardiovascular (CV) morbidity and mortality. Despite a great bulk of data in the existing medical literature, the pathophysiology of AF in patients with hypertensive heart disease (HHD) is poorly understood, and the underlying signaling pathways linking hypertension (HTN) to AF remain to be fully elucidated. The scope of this article is to discuss the myocardial anatomical and physiological alterations that occur in HTN, and highlight the proposed electrophysiological mechanisms that cause the hypertensive heart to fibrillate. In addition, we will focus on the latest ESC 2016 guidelines for the risk stratification of AF patients as a tool to guide anticoagulation which represents the mainstay of treatment for AF. Last, the other therapeutic approaches for hypertensives with AF currently adopted for optimal patient management will be reviewed.
- 1 January 2018
- Published by IMR Press in Frontiers in Bioscience-Scholar
- Vol. 10 (2) , 276-284
Hypertension and atrial fibrillation a bench to bedside perspective
Atrial Fibrillation (AF) is the most common cardiac arrhythmia in clinical practice and its prevalence increases markedly with advancing age, worldwide. Almost every primary care physician, internist, or cardiologist, has dealt with stroke or with other complications of AF. Still, its management remains a hot issue for clinicians and the debate over which treatment strategy is the best is ongoing. Moreover, AF increases significantly the total cardiovascular (CV) morbidity and mortality. Despite a great bulk of data in the existing medical literature, the pathophysiology of AF in patients with hypertensive heart disease (HHD) is poorly understood, and the underlying signaling pathways linking hypertension (HTN) to AF remain to be fully elucidated. The scope of this article is to discuss the myocardial anatomical and physiological alterations that occur in HTN, and highlight the proposed electrophysiological mechanisms that cause the hypertensive heart to fibrillate. In addition, we will focus on the latest ESC 2016 guidelines for the risk stratification of AF patients as a tool to guide anticoagulation which represents the mainstay of treatment for AF. Last, the other therapeutic approaches for hypertensives with AF currently adopted for optimal patient management will be reviewed.