AMAmelia S. Munsterman

Amelia S. Munsterman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amelia S. Munsterman has a total of 127 co-authors. Here are the top co-authors by number of shared publications:

  • R. Reid Hanson

    JT Vaughan Large Animal Teaching Hospital Auburn University Auburn Alabama USA

    16 shared publications
  • Matthew O. D. Coleridge

    Fethard Equine Hospital Fethard Tipperary Ireland

    5 shared publications
  • Alex M. Gillen

    Philip Leverhulme Equine Hopsital University of Liverpool Neston UK

    4 shared publications
  • Jack Kottwitz

    Department of Large Animal Clinical Sciences, College of Veterinary Medicine Michigan State University East Lansing Michigan USA

    4 shared publications
  • Ramsis Farag

    Center of Polymers and Advanced Composites, Samuel Ginn College of Engineering, Auburn University, Auburn, AL 36849

    4 shared publications
  • Valeria Albanese

    Tierärztliches Kompetenzzentrum für Pferde Großwallstadt Altano GmbH, 63868 Großwallstadt, Germany

    4 shared publications

Latest Publications

  • Open Access

    Comparison of blind end closure techniques in equine ileum

    by Rachel L. Hilliard, Amanda Prisk, Sichao Wang, Stefanie Hansen, Amelia Munsterman

    Objective: To determine the difference in bursting pressure (BP), bursting wall tension (BWT), and closure speed between commonly utilized methods of ileal stump closure. Study design: Randomized experimental study. Sample population: A total of 71 ileal segments from 18 healthy horses. Methods: Ileum was collected postmortem from 18 horses and divided into four segments. One end of each segment was closed using one of three techniques: Parker‐Kerr (PK), gastrointestinal staples (ST), or gastrointestinal staples with a Lembert staple oversew (SO). Closure time was recorded. Control (C) segments were not altered. Segments were distended until failure. BP and infusion volume were documented, and BWT was calculated. Results: BP and BWT were higher for controls compared to all closure methods ( p < .001). No differences in BP ( p > .999) or BWT ( p > .77) were found between closure methods. ST technique was 27.1 times faster than PK ( p < .001) and 23.4 times faster than SO ( p < .001). SO was 1.2 times faster than PK ( p < .001). Mechanisms of failure were predictable within each technique. Conclusion: No difference in BP or BWT was observed between closure techniques in healthy ileum. ST and SO were significantly faster than PK. Clinical significance: The similarity in bursting strength across techniques suggests that closure method should be chosen based on other factors. The ST closure was faster compared to other techniques, and the addition of an oversewing pattern did not improve security of closure.

  • Open Access

    Pelvic Flexure Enterotomy in Horses: Scoping Review and Synthesis of the Literature (1996–2026)

    by Valeria Albanese, Paola Straticò, Amelia Munsterman

    This scoping review maps the available literature aimed at identifying the most appropriate technique for suturing pelvic flexure enterotomies in horses. A comprehensive search of Web of Science, Google Scholar, and the National Center for Biotechnology Information was conducted for studies published between January 1996 and February 2026, using terms related to pelvic flexure enterotomy and equine patients. From 22,146 records, only five ex vivo studies on healthy equine colon specimens met the inclusion criteria. The studies compared variables such as suturing time, suture pattern, material, bursting pressure, luminal diameter reduction, and cost. Double-layer hand-sewn closure generally achieved the highest bursting pressures, although it required longer operative time, while TA90 stapling was the most expensive option. Because ex vivo models cannot reproduce tissue healing or host–construct interactions, the clinical applicability of the available evidence remains limited. Nonetheless, a full-thickness simple continuous pattern oversewn with a continuous Cushing pattern appears to offer the most dependable mechanical security until stronger in vivo evidence becomes available.

  • Open Access

    Alactic base excess is not a sensitive or specific diagnostic tool for outcome in horses with colic

    by Corinne E. Crosby, Annette O’cOnnor, Amelia S. Munsterman

    Introduction: Colic is a significant source of morbidity and mortality in horses, and no single biomarker can distinguish surgical from medical colic or predict mortality. Alactic base excess (ABE) has shown an association with mortality and renal insufficiency in humans but has not been evaluated in veterinary species. The purpose of this study was to determine the value of ABE as a diagnostic tool for horses treated for gastrointestinal disease.Methods: This retrospective case series evaluated horses admitted for acute gastrointestinal disease over a 5-year period (2019–2024). Signalment, physical examination findings, venous blood gas analysis results, packed cell volume and total solids on admission, findings in cases undergoing exploratory celiotomy, and outcome were collected from the medical record. Variables were evaluated individually, and by multivariate analysis for sensitivity and specificity to differentiate medical from surgical colic, strangulating versus non-strangulating lesions, and between survivors and non-survivors after surgical intervention. Optimal Youden cut-off values and area under the receiver operating curve (AUC) were calculated.Results: Five hundred and thirty eight horses met the inclusion criteria. Multiple presentations by the same horse were each counted as individual presentations, resulting in 585 admissions. While ABE was higher in surgical cases that did not survive (p = 0.029), it did not discriminate between medical and surgical colic or between survivors and non-survivors as a sole diagnostic or multivariate modality. The best predictor of medical or surgical treatment was serum glucose levels (AUC = 0.76, Se = 0.76, Sp = 0.67). Serum glucose levels were also the best predictor of strangulating versus non-strangulating lesions (AUC = 0.81, Se = 0.67, Sp = 0.83). The model for survival after surgery included age and serum L-lactate (AUC = 0.76, Se = 0.73, Sp = 0.69).Discussion: Elevations in alactic base excess values in surgical cases that did not survive may indicate compensation for hyperlactatemia with complex metabolic derangements. Our investigation supports the use of hyperglycemia and hyperlactatemia as markers of severity for horses with gastrointestinal disease.


  • Open Access

    Primary Jejunal Impactions Resolved via Exploratory Celiotomy in Six Horses: 2017–2023

    by Jaclyn Willette, Alyssa Guinn, Amelia Munsterman

    Impactions of the jejunum are rarely described in the literature. The current case series describes six cases of adult horses with jejunal impactions with feed material diagnosed by exploratory celiotomy. Horses underwent exploratory celiotomy based off of their degree of pain despite medical management and concerns for a primary strangulating small intestinal lesion. All jejunal impactions were relieved via manual decompression of the impaction into the cecum. None of the cases underwent a resection or anastomosis at the site of impaction. All horses were treated with gastroprotectants (omeprazole or sucralfate) post-operatively; 3/6 horses underwent a gastroscopy and were diagnosed with squamous gastric ulceration prior to treatment. Despite post-operative complications, 5/6 horses survived to hospital discharge.

  • Open Access

    Evaluation of the Effects of Detomidine on Equine Myoelectrical Activity Using Electrointestinography

    by Amelia S. Munsterman, Ana S. Dias Moreira, Jack Kottwitz

    Objective: To evaluate the effects of detomidine on equine intestinal slow‐wave activity and frequency distribution measured by electrointestinography (EIG).Design: Prospective, experimental study.Setting: University teaching hospital.Animals: A convenience sample of twelve 7‐ to 21‐year‐old clinically normal horses.Interventions: Horses were randomly assigned to saline control (four horses) or detomidine treatment (eight). After obtaining a 30‐min baseline EIG, a saline or detomidine bolus was administered, followed by a constant rate infusion, and another EIG was recorded. Ultrasonographic examinations monitored cecal and left ventral colon contractions. Spectral analysis was performed to evaluate changes in dominant frequency, dominant power, total power, percent frequency distribution, and changes in slow‐wave rhythmic activity.Measurements and Main Results: Median (interquartile range [IQR]) dominant frequency in cycles per minute (cpm) was similar for the cecum (2.4 cpm; IQR: 0.51 cpm) and left ventral colon (2.13 cpm; IQR: 0.16 cpm) and unchanged by either treatment (P > 0.074). Compared with saline, which was unchanged, detomidine reduced dominant power ratios for both cecum (0.45; IQR: 0.18) and left ventral colon (0.63; IQR: 0.35; P = 0.002). Detomidine decreased total power for the cecum in the 2–4 cpm frequency range from 55.0% (IQR: 4.4%) to 43.1% (IQR: 6.7%) and for the left ventral colon from 54.4% (IQR: 5.5%) to 27.3% (IQR: 9.3%; P < 0.087). Total power for the cecum was increased in the 8–12 cpm frequency range from 9.6% (IQR: 1.9%) to 18.5% (IQR: 6.6%; P = 0.0044) with detomidine. No change in frequency distribution was noted in controls (P > 0.08). Dominant power correlated with the rate of contractions measured ultrasonographically (P < 0.001).Conclusions: Detomidine decreased dominant power ratios for both the cecum and left ventral colon and produced tachyarrhythmias in cecal slow‐wave activity. The correlation of dominant power with intestinal contractions supports the clinical development of EIG to diagnose equine motility disorders.


  • Open Access

    Electrointestinography, ultrasonographic contractility, and borborygmi of the cecum and colon are not altered by a single episode of hand walking exercise in healthy horses

    by Amelia S. Munsterman, Jessica M. Rogers-Tirado, Jack Kottwitz

    OBJECTIVE: To evaluate the effect of hand walking exercise on myoelectrical activity and contractility in normal, healthy horses. METHODS: Prospective experimental design. A convenience sample of 8 horses were randomized to a control or hand walking treatment group; each horse underwent both treatments. After a 30-minute baseline electrointestinography (EIG), horses were stall rested or hand walked for 15 minutes. Electrointestinography was repeated immediately and at 2 hours. Ultrasonography and auscultation monitored cecal and left ventral colon (LVC) contractions during EIG. Electrointestinography spectral analysis obtained dominant frequency (DF), dominant power (DP), total power (TP) frequency distribution, and changes in slow-wave rhythmic activity. RESULTS: The median (IQR) DF in cycles per minute (cpm) was higher for the cecum (2.067 cpm; IQR, 0.633 cpm) compared to the LVC (2.0 cpm; IQR, 0.396 cpm) but was unchanged by either treatment. Cecal DP (0.0086 mV; IQR, 0.0070 mV) was higher than LVC DP (0.0068 mV; IQR, 0.0051 mV) in the hand walking group, but DP and TP were unaffected by either treatment over time. Borborygmi at all time points were unchanged in both treatment groups. Ultrasonographic contractions were similar across time in both treatment groups and correlated with borborygmi (ρ = 0.63). Dominant power did not correlate with contractions or borborygmi (P > .2081). CONCLUSIONS: Brief hand walking as a single strategy to increase gastrointestinal motility did not affect contractility or EIG in normal horses. CLINICAL RELEVANCE: Fasting and stall rest may not represent the spectrum of severity of gastrointestinal stasis observed in clinical cases. This model is directly applicable to horses fasted prior to surgical procedures.

  • Open Access

    Evaluation of point‐of‐care capillary and venous blood glucose concentrations in hospitalized neonatal foals

    by Ana Sofia Dias Moreira, Hsin‐Yi Weng, Laura D. Hostnik, Erin M. Beasley, Simon F. Peek, Amelia S. Munsterman

    Objective: To compare glucose measurements from capillary and venous blood samples using a point‐of‐care (POC) glucometer with a standard laboratory (colorimetric, glucose oxidase) assay (LABGLU) in a population of hospitalized, neonatal foals.Design: Multicenter, prospective, experimental study, conducted between March 2019 and June 2020.Setting: Four university teaching hospitals and 1 private referral hospital.Animals: Fifty‐four hospitalized neonatal (≤30 days of age) foals.Interventions: Simultaneous capillary (muzzle, POCMUZ) and venous (jugular, POCJUG) blood samples were obtained to determine POC glucose concentrations. Venous samples were also analyzed by LABGLU. Each foal was sampled at the time of enrollment or admission to the hospital and at 1 subsequent point during hospitalization. Indirect mean arterial pressure and hematocrit were concurrently recorded.Measurements and Main Results: Bland–Altman analysis showed a mean bias (95% limits of agreement) of −28.0 (−88.6 to 32.6) mg/dL for comparison of POCJUG with LABGLU, −8.2 (−94.3 to 78.0) mg/dL for POCMUZ and LABGLU, and 18.8 (−44.4 to 82.0) mg/dL for POCMUZ and POCJUG. A total of 63.5% of the POCJUG and 45.2% of the POCMUZ samples exceeded the reference value by ±15 mg/dL (for LABGLU samples <75 mg/dL) or ±15% (for LABGLU samples ≥75mg/dL). Concordance correlation coefficient (95% confidence interval [CI]) indicated a fair agreement between POCJUG and LABGLU (0.75, 95% CI: 0.66–0.82) and between POCMUZ and LABGLU (0.71, 95% CI: 0.58–0.80). Fifty percent (14/28) of hypoglycemic foals on the reference method were incorrectly classified as euglycemic by POCJUG, and 5 of 28 were incorrectly classified by POCMUZ.Conclusions: In the sampled population, the chosen POC glucometer lacked agreement with the standard laboratory measurement. Limits of agreement were wide for both POCJUG and POCMUZ. Inaccuracies in POC results could impact decision‐making in the clinical management of glycemic control in hospitalized neonatal foals and, importantly, increase the risk of hypoglycemic events being underdiagnosed in critical patients.


  • Open Access

    Evaluation of the in vitro performance of the double forwarder knot, compared to square and surgeon's knots using large gauge suture

    by Harriet K. Barnes, Amelia S. Munsterman, Alex M. Gillen, Stephanie S. Caston, Dane M. Tatarniuk, Kevin Kersh, Tamara Swor, R. Reid Hanson

    Objective: The aim of the study was to evaluate the strength and size of the double forwarder (DF) knot in 2 and 3 USP polyglactin 910 when used to form a ligature and to compare the knot holding capacity (KHC), size and weight of the DF knot to surgeon's (SU) and square (SQ) knots with varying numbers of throws.Study design: Laboratory study.Study population: Knotted suture.Methods: Knots were tied using 2 and 3 USP polyglactin 910 and tested on a universal testing machine under linear tension. Mode of failure and (KHC) were recorded. Knot volume and weight were determined by digital micrometer and balance. KHC, size, and weight between knot type, number of throws, and suture type and size were compared using ANOVA testing, with p < .05 as significant.Results: In both suture types, DF knots had a higher KHC than SQ/SU knots (p < .004), with the exception of SU knots with 6–8 throws in 3 USP polyglactin 910 (p > .42). All DF knots failed by suture breakage at the knot, as did all SQ/SU knots with >6 throws. DF knots in 2 and 3 USP polyglactin 910 were larger and heavier than SQ and SU knots when the same number of throws was applied (p < .003).Conclusion: Self‐locking DF knots provided increased strength compared to SU/SQ in large gauge suture but only when fewer than six throws are applied to SU/SQ knots.Clinical relevance: The new DF knot could be an alternative for a secure ligature.

  • Pelvic flexure enterotomy in the horse: A review of current literature

    by Valeria Albanese, Paola Straticò, Amelia Munsterman

    Summary: Enterotomy of the pelvic flexure is commonly performed during colic surgery in the horse to empty the large colon of its contents. A two‐layer closure with absorbable suture material is recommended, but a consensus has not been established. Many different techniques have been described and tested to evaluate surgical time, luminal diameter reduction, bursting pressure and post‐operative complications including adhesion formation. The results of these studies vary within and between enterotomy techniques. The objective of this narrative review was to evaluate and summarise relevant published literature on pelvic flexure enterotomy techniques in the horse.


  • Open Access

    Ex vivo evaluation of a novel suture loop method for equine intestinal biopsies

    by Amelia S. Munsterman, Ashley R. VanderBroek, Jack J. Kottwitz, Victoria E. Watson

    Objective: To compare a novel suture loop method for intestinal biopsies (SLB) with a two‐layer, hand‐sutured biopsy (HSB) technique in equine small and large intestines.Study design: Experimental, randomized, ex vivo study.Animals: Eight healthy adult horses.Methods: The duodenum, aboral jejunum, and ventral and dorsal large colon were harvested after euthanasia and divided into three sections each. The sections were randomized to SLB, HSB, or control (C, no biopsy) groups. Tissue samples were excised after placement of a suture loop formed by a 4S Roeder knot and oversewn with a Cushing pattern using barbed suture (SLB), or a simple continuous pattern oversewn with a Cushing pattern (HSB). Intraluminal diameter was assessed with contrast radiographs; bursting pressure and wall tension were determined using a solid‐state sensor after instillation of fluid. Tissue samples were evaluated by a board‐certified pathologist.Results: Tissue samples were full thickness with similar depth and quality (p > .3). Changes in intraluminal diameter did not differ between methods (p > .16). The bursting pressures were higher for controls than biopsied sections (p < .009) but were not different between biopsy methods (p = .998). Bursting wall tension was higher for controls (p < .02) and was similar for both biopsy methods (p = .852).Conclusion: The SLB was equivalent to HSB in strength and effect on intraluminal diameter. The HSB samples were larger and more likely to contain mucosa/villi for histologic diagnosis.Clinical significance: The SLB method can be adapted for laparoscopic surgery to obtain both small and large intestinal biopsies. Further investigation is needed before clinical use.