Jian-Bo He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jian-Bo He has a total of 248 co-authors. Here are the top co-authors by number of shared publications:
Yan Wang
Hefei University of Technology
24 shared publicationsBing Li
21 shared publicationsNing Deng
Hefei University of Technology
20 shared publications- Fang Li
Hefei University of Technology
19 shared publications Fang Li
15 shared publicationsChao-Xiong Li
Anhui Province Key Laboratory of Green Manufacturing of Power Battery, Tianneng, Jieshou, People’s Republic of China
6 shared publications
Latest Publications
- 30 October 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Wearable Microfluidic Electrochemical Platform Based on One-Pot Prussian Blue-Embedded Molecularly Imprinted Polymers for Simultaneous Detection of Sweat Uric Acid and Urea
Non-invasive wearable sensing of sweat uric acid (UA) and urea provides a promising strategy for early chronic kidney disease screening. Nevertheless, most electrochemical sensors for UA and urea detection suffer from insufficient anti-interference and require exogenous redox probes, restricting reagent-free on-body measurement. Herein, we develop a wearable microfluidic electrochemical platform based on Prussian blue-embedded molecularly imprinted polymer (PB-MIP) composite materials for reagent-free, enzyme-free dual-biomarker quantification. Urea-specific and UA-specific PB-MIP composites are prepared via a facile one-step ultraviolet polymerization strategy. PB uniformly embedded within the imprinted framework acts as an intrinsic solid-state redox mediator, integrating specific molecular recognition and built-in electrochemical signal transduction into a single functional material. The two PB-MIP composites are drop-coated on dual working electrodes of a screen-printed carbon electrode, coupled with a capillary-driven microfluidic chip to construct a wearable electrochemical platform. Benefiting from the microfluidic design, the system enables pump-free spontaneous collection of trace sweat samples and achieves simultaneous quantification of sweat UA and urea. The platform exhibits wide linear ranges (0.1–600 μM for uric acid, 0.1–300 mM for urea), low limits of detection, excellent anti-interference capacity, recyclability, and favorable storage stability. On-body dietary intervention tests capture clear postprandial biomarker fluctuations, and detection results show good agreement with HPLC-MS reference values. This work offers a straightforward material-engineering strategy to develop probe-free MIP sensing interfaces and integrated wearable microfluidic devices, showing promising prospects for noninvasive preliminary screening of kidney function.
- 30 October 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Wearable Microfluidic Electrochemical Platform Based on One-Pot Prussian Blue-Embedded Molecularly Imprinted Polymers for Simultaneous Detection of Sweat Uric Acid and Urea
Non-invasive wearable sensing of sweat uric acid (UA) and urea provides a promising strategy for early chronic kidney disease screening. Nevertheless, most electrochemical sensors for UA and urea detection suffer from insufficient anti-interference and require exogenous redox probes, restricting reagent-free on-body measurement. Herein, we develop a wearable microfluidic electrochemical platform based on Prussian blue-embedded molecularly imprinted polymer (PB-MIP) composite materials for reagent-free, enzyme-free dual-biomarker quantification. Urea-specific and UA-specific PB-MIP composites are prepared via a facile one-step ultraviolet polymerization strategy. PB uniformly embedded within the imprinted framework acts as an intrinsic solid-state redox mediator, integrating specific molecular recognition and built-in electrochemical signal transduction into a single functional material. The two PB-MIP composites are drop-coated on dual working electrodes of a screen-printed carbon electrode, coupled with a capillary-driven microfluidic chip to construct a wearable electrochemical platform. Benefiting from the microfluidic design, the system enables pump-free spontaneous collection of trace sweat samples and achieves simultaneous quantification of sweat UA and urea. The platform exhibits wide linear ranges (0.1–600 μM for uric acid, 0.1–300 mM for urea), low limits of detection, excellent anti-interference capacity, recyclability, and favorable storage stability. On-body dietary intervention tests capture clear postprandial biomarker fluctuations, and detection results show good agreement with HPLC-MS reference values. This work offers a straightforward material-engineering strategy to develop probe-free MIP sensing interfaces and integrated wearable microfluidic devices, showing promising prospects for noninvasive preliminary screening of kidney function.
- 26 October 2026
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 65 (44) , 23531-23542
Mass Transfer Intensification via Intra-Diaphragm Gap Feeding in Alkaline Water Electrolysis
Alkaline water electrolysis (AWE) coupled with fluctuating photovoltaic power confronts severe operational limitations stemming from intrinsic near-electrode mass transfer barriers. These transport defects exacerbate both ohmic polarization and trans-diaphragm H2/O2 crossover, significantly restricting the flexible operating window of electrolyzer stacks. Targeting these inherent limitations, this work proposes an innovative intradiaphragm gap (IDG) inside-to-out feeding configuration equipped with decoupled gas–liquid efflux channels. The IDG configuration achieves uniform close-range electrolyte supply across the entire electrode surfaces and mitigates two-phase buildup within the cell compartment via separate dual outlets. The hydrogen impurity level in oxygen streams remains below the 2 vol % safety threshold even at an ultralow current density of 10 mA cm–2. The IDG scheme lowers ohmic resistance by 25.3% and hydrogen-specific energy consumption by 1.15 kWh Nm–3 at 1000 mA cm–2. Under dynamic photovoltaic load fluctuations, the IDG electrolyzer maintains stable operation and compliant gas purity, yielding 14.3% higher annual hydrogen yield than conventional bottom-fed setups. Synergistically optimized electrolyte distribution and interfacial gas removal reinforce near-electrode mass transfer, improving overall cell efficiency and dynamic load adaptability. This feeding configuration provides a feasible retrofitting strategy for commercial alkaline electrolysis facilities.
- 26 October 2026
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 65 (44) , 23531-23542
Mass Transfer Intensification via Intra-Diaphragm Gap Feeding in Alkaline Water Electrolysis
Alkaline water electrolysis (AWE) coupled with fluctuating photovoltaic power confronts severe operational limitations stemming from intrinsic near-electrode mass transfer barriers. These transport defects exacerbate both ohmic polarization and trans-diaphragm H2/O2 crossover, significantly restricting the flexible operating window of electrolyzer stacks. Targeting these inherent limitations, this work proposes an innovative intradiaphragm gap (IDG) inside-to-out feeding configuration equipped with decoupled gas–liquid efflux channels. The IDG configuration achieves uniform close-range electrolyte supply across the entire electrode surfaces and mitigates two-phase buildup within the cell compartment via separate dual outlets. The hydrogen impurity level in oxygen streams remains below the 2 vol % safety threshold even at an ultralow current density of 10 mA cm–2. The IDG scheme lowers ohmic resistance by 25.3% and hydrogen-specific energy consumption by 1.15 kWh Nm–3 at 1000 mA cm–2. Under dynamic photovoltaic load fluctuations, the IDG electrolyzer maintains stable operation and compliant gas purity, yielding 14.3% higher annual hydrogen yield than conventional bottom-fed setups. Synergistically optimized electrolyte distribution and interfacial gas removal reinforce near-electrode mass transfer, improving overall cell efficiency and dynamic load adaptability. This feeding configuration provides a feasible retrofitting strategy for commercial alkaline electrolysis facilities.
- Open Access
- 17 October 2026
- Published by Elsevier in SSRN Electronic Journal
Flexible Wearable Electrochemical-Colorimetric Dual-Modal Microfluidic Device for Multiplexed Sweat Biomarker Analysis toward Skin Physiological Status Evaluation
Noninvasive multi-parametric assessment of skin physiological status is essential for personalized skincare yet remains challenging with existing technologies. Herein, a flexible wearable microfluidic platform with integrated dual-modal electrochemical-colorimetric sensing was developed for simultaneous detection of four key sweat biomarkers, including lactate, urea, Pb2+, and pH, enabling comprehensive evaluation of skin physiological conditions. To achieve enzyme-free lactate detection, ZnO@Au nanoflowers were synthesized and modified on the electrode surface and then Prussian blue (PB) nanoparticles were deposited as redox mediators, followed by electropolymerization of a lactate-imprinted polymer film. This layered structure creates an in-situ signal transition and amplification unit where MIP binding events directly modulate PB redox currents. For urea, Pb2+, and pH detection, three independent paper-based colorimetric chips pre-loaded with their respective chromogenic reagents were fabricated. The detection results can be read directly by eye or with a smartphone camera with no additional liquid reagents or lab equipment. The two sensing modules are incorporated into a capillary-driven multichannel polydimethylsiloxane microfluidic network that enables autonomous sweat collection, transportation, and parallel multi-analyte analysis. The integrated system exhibited favorable analytical performance, including wide detection range (0.1-40 mM for lactate, 5-90 mM for urea, 0.02-1 mM for Pb2+, pH 4.5-7.5), low limits of detection, good selectivity, stability and reproducibility. On-body real-sweat testing on human volunteers successfully captured dynamic variations of the four biomarkers pre- and post-topical skincare administration, enabling multidimensional evaluation of skin metabolism, hydration, acid-base balance, and heavy metal exposure. This enzyme-free, dual-modal wearable platform provides a low-cost, user-friendly approach for noninvasive skin physiological status evaluation.
- 17 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFlexible Wearable Electrochemical-Colorimetric Dual-Modal Microfluidic Device for Multiplexed Sweat Biomarker Analysis toward Skin Physiological Status Evaluation
Noninvasive multi-parametric assessment of skin physiological status is essential for personalized skincare yet remains challenging with existing technologies. Herein, a flexible wearable microfluidic platform with integrated dual-modal electrochemical-colorimetric sensing was developed for simultaneous detection of four key sweat biomarkers, including lactate, urea, Pb2+, and pH, enabling comprehensive evaluation of skin physiological conditions. To achieve enzyme-free lactate detection, ZnO@Au nanoflowers were synthesized and modified on the electrode surface and then Prussian blue (PB) nanoparticles were deposited as redox mediators, followed by electropolymerization of a lactate-imprinted polymer film. This layered structure creates an in-situ signal transition and amplification unit where MIP binding events directly modulate PB redox currents. For urea, Pb2+, and pH detection, three independent paper-based colorimetric chips pre-loaded with their respective chromogenic reagents were fabricated. The detection results can be read directly by eye or with a smartphone camera with no additional liquid reagents or lab equipment. The two sensing modules are incorporated into a capillary-driven multichannel polydimethylsiloxane microfluidic network that enables autonomous sweat collection, transportation, and parallel multi-analyte analysis. The integrated system exhibited favorable analytical performance, including wide detection range (0.1-40 mM for lactate, 5-90 mM for urea, 0.02-1 mM for Pb2+, pH 4.5-7.5), low limits of detection, good selectivity, stability and reproducibility. On-body real-sweat testing on human volunteers successfully captured dynamic variations of the four biomarkers pre- and post-topical skincare administration, enabling multidimensional evaluation of skin metabolism, hydration, acid-base balance, and heavy metal exposure. This enzyme-free, dual-modal wearable platform provides a low-cost, user-friendly approach for noninvasive skin physiological status evaluation.
- 17 January 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1389, 345105
Flexible hydrophilic-hydrophobic array detection patch integrated with Au NPs/Cu-TCPP(Fe) biomimetic cascade catalysis reactions for enzyme-free sweat glucose monitoring
- 17 January 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1389, 345105
Flexible hydrophilic-hydrophobic array detection patch integrated with Au NPs/Cu-TCPP(Fe) biomimetic cascade catalysis reactions for enzyme-free sweat glucose monitoring
- 30 August 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 170
Decoupled water electrolysis hydrogen production enabled by Ni-based "solid membrane" towards integrated systems
- 30 August 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 170
Decoupled water electrolysis hydrogen production enabled by Ni-based "solid membrane" towards integrated systems
- 10 June 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (25) , 36444-36454
Flexible Wearable Microfluidic Colorimetric Sensor for Multiplex Bioenzyme-Free Detection of Creatinine, Urea, and Magnesium Ions in Sweat
Wearable microfluidic detection devices for noninvasive sweat analysis are highly desirable for human health monitoring. Herein, we present a bioenzyme-free microfluidic colorimetric detection device for simultaneous detection of creatinine (Cre), urea, and Mg2+ in sweat, enabling comprehensive kidney function and mental stress assessment. The device leverages a ternary catalytic system composed of H2MoO5 nanomaterial, Cu2+, and Cre, which exhibits significantly enhanced oxidase-like activity. This system directly catalyzes the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) to generate a blue product (ox-TMB), providing a robust platform for Cre detection without the need for bioenzymes. For urea and Mg2+ detection, 4-dimethylaminobenzaldehyde and chromium black T were employed as effective chromogenic reagents, respectively. A flexible multichannel microfluidic chip was fabricated, incorporating specific colorimetric reagent-modified paper chips into the corresponding reaction reservoirs. This design allows for the simultaneous detection of Cre, urea, and Mg2+ in sweat with linear ranges of 10-100 μM, 10-70 mM, and 0.5-8 mM, respectively. The device's performance was validated using actual sweat samples, with detection results analyzed via a smartphone application, demonstrating high accuracy and reliability. This work introduces a simple, low-cost, and stable bioenzyme-free microfluidic colorimetric detection device, offering significant potential for in situ and intelligent sweat analysis. The integration of smartphone technology further enhances its practicality, making it a promising tool for real-time health monitoring and point-of-care testing.
- 10 June 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (25) , 36444-36454
Flexible Wearable Microfluidic Colorimetric Sensor for Multiplex Bioenzyme-Free Detection of Creatinine, Urea, and Magnesium Ions in Sweat
Wearable microfluidic detection devices for noninvasive sweat analysis are highly desirable for human health monitoring. Herein, we present a bioenzyme-free microfluidic colorimetric detection device for simultaneous detection of creatinine (Cre), urea, and Mg2+ in sweat, enabling comprehensive kidney function and mental stress assessment. The device leverages a ternary catalytic system composed of H2MoO5 nanomaterial, Cu2+, and Cre, which exhibits significantly enhanced oxidase-like activity. This system directly catalyzes the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) to generate a blue product (ox-TMB), providing a robust platform for Cre detection without the need for bioenzymes. For urea and Mg2+ detection, 4-dimethylaminobenzaldehyde and chromium black T were employed as effective chromogenic reagents, respectively. A flexible multichannel microfluidic chip was fabricated, incorporating specific colorimetric reagent-modified paper chips into the corresponding reaction reservoirs. This design allows for the simultaneous detection of Cre, urea, and Mg2+ in sweat with linear ranges of 10-100 μM, 10-70 mM, and 0.5-8 mM, respectively. The device's performance was validated using actual sweat samples, with detection results analyzed via a smartphone application, demonstrating high accuracy and reliability. This work introduces a simple, low-cost, and stable bioenzyme-free microfluidic colorimetric detection device, offering significant potential for in situ and intelligent sweat analysis. The integration of smartphone technology further enhances its practicality, making it a promising tool for real-time health monitoring and point-of-care testing.
- 3 March 2025
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 30 (11) , 3699-3707
Direct seawater electrolysis through in situ purification using dual ion exchange membranes
- 3 March 2025
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 30 (11) , 3699-3707
Direct seawater electrolysis through in situ purification using dual ion exchange membranes
- 27 February 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 508
Overcoming the conventional thermodynamic limit of water electrolysis to boost renewable energy storage
- 27 February 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 508
Overcoming the conventional thermodynamic limit of water electrolysis to boost renewable energy storage