ATAndreas Taubel

Andreas Taubel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andreas Taubel has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multicaloric effect in FeRh, exploiting the thermal hysteresis in a multi-stimuli cycle combining pulsed magnetic field and uniaxial load

    by F. Scheibel, N. Shayanfar, L. Pfeuffer, T. Gottschall, S. Dittrich, A. Taubel, A. Aubert, I. Radulov, K. P. Skokov, O. Gutfleisch

    Large magnetocaloric effects can be observed in materials with first-order magneto-structural phase transition. However, materials with large thermal hysteresis show a reduced effect in moderate fields (∼2 T) because the external field is insufficient to induce a fully reversible transformation. The hysteresis can be overcome or even exploited by applying a second external stimulus. A multi-stimuli test bench has been built to demonstrate the multicaloric effect in FeRh alloy using a pulsed magnetic field up to 9 T and a uniaxial stress of up to 700 MPa. A cyclic multicaloric effect of ±2.5 K could be observed for a sequential application of a pulsed field of 3 T and a uniaxial stress of 700 MPa. The interplay among external field strength, thermal hysteresis, and the transition width enables the use of pulsed magnetic fields and allows a decoupling of the applied magnetic field and the heat transfer process in the multi-stimuli cycle.


  • Open Access

    Influence of Gd-rich precipitates on the martensitic transformation, magnetocaloric effect, and mechanical properties of Ni–Mn–In Heusler alloys—A comparative study

    by Franziska Scheibel, Wei Liu, Lukas Pfeuffer, Navid Shayanfar, Andreas Taubel, Konstantin P. Skokov, Stefan Riegg, Yuye Wu, Oliver Gutfleisch

    A multi-stimuli cooling cycle can be used to increase the cyclic caloric performance of multicaloric materials like Ni–Mn–In Heusler alloys. However, the use of uniaxial compressive stress as an additional external stimulus to a magnetic field requires good mechanical stability. Improvement in mechanical stability and strength by doping has been shown in several studies. However, doping is always accompanied by grain refinement and a change in transition temperature. This raises the question of the extent to which mechanical strength is related to grain refinement, transition temperature, or precipitates. This study shows a direct comparison between a single-phase Ni–Mn–In and a two-phase Gd-doped Ni–Mn–In alloy with the same transition temperature and grain size. It is shown that the excellent magnetocaloric properties of the Ni–Mn–In matrix are maintained with doping. The isothermal entropy change and adiabatic temperature change are reduced by only 15% in the two-phase Ni–Mn–In Heusler alloy compared to the single-phase alloy, which results from a slight increase in thermal hysteresis and the width of the transition. Due to the same grain size and transition temperature, this effect can be directly related to the precipitates. The introduction of Gd precipitates leads to a 100% improvement in mechanical strength, which is significantly lower than the improvement observed for Ni–Mn–In alloys with grain refinement and Gd precipitates. This reveals that a significant contribution to the improved mechanical stability in Gd-doped Heusler alloys is related to grain refinement.


  • Impact of magnetic and antisite disorder on the vibrational densities of states in Ni2MnSn Heusler alloys

    by Olga N. Miroshkina, Benedikt Eggert, Johanna Lill, Benedikt Beckmann, David Koch, Michael Y. Hu, Tobias Lojewski, Simon Rauls, Franziska Scheibel, Andreas Taubel, et al.

    We have performed a combined experimental and theoretical investigation of the vibrational properties of Ni2MnSn Heusler alloys. Sn-partial vibrational density of states (VDOS) of Sn119 was measured by nuclear resonant inelastic x-ray scattering at temperatures of 15 and 300 K, while magnetism and local environment of Sn was resolved by Sn119 Mössbauer spectroscopy. Using density functional theory, we associate the peaks in the VDOS with particular features in the element-resolved phonon dispersion of L21 ordered Ni2MnSn. The good agreement between theory and experiment in the low-energy region provides the evidence that the inversion of optical modes at Γ involving the displacement of Ni and the heavier main group element atoms, which was predicted previously for other Ni-Mn-based Heusler compounds, is also a characteristic property of Ni2MnSn. Introducing different types of magnetic and antisite disorder in our calculations results in a distinctive redistribution and broadening of the Sn-VDOS, suggesting that considering partial disorder further improves the agreement with the experiment in particular at the highest phonon energies.


  • Maximum performance of an active magnetic regenerator

    by Dimitri Benke, Maximilian Fries, Tino Gottschall, Dominik Ohmer, Andreas Taubel, Konstantin Skokov, Oliver Gutfleisch

    Magnetocaloric materials change their temperature when a magnetic field is applied or removed, which allows building a magnetic cooling device. We derive an analytical expression for the maximum heat that such a material can transfer in one cooling cycle by investigating the operation of a simplified active magnetic regenerator (AMR). The model largely only depends on the adiabatic temperature change, the specific entropy change, and the temperature span between the hot and cold reservoirs. While this expression overestimates the performance of a real AMR due to its simplification, it can predict an upper limit of any AMRs' performance independent of the implementation details. Based on this, we calculate the upper limit of the cooling power of magnetic cooling devices at any temperature span, frequency, mass, and material. This upper limit is used to predict how the thermal span is scaling with the applied magnetic field, and it can be utilized for the optimization of the magnetic field source. Additionally, we confirm that the product of isothermal entropy and adiabatic temperature change, already used in the literature, is a suitable figure of merit for magnetocaloric materials.


  • Top Cited Papers
    Open Access

    Making a Cool Choice: The Materials Library of Magnetic Refrigeration

    by Tino Gottschall, Konstantin P. Skokov, Maximilian Fries, Andreas Taubel, Iliya Radulov, Franziska Scheibel, Dimitri Benke, Stefan Riegg, Oliver Gutfleisch

    The phase‐down scenario of conventional refrigerants used in gas–vapor compressors and the demand for environmentally friendly and efficient cooling make the search for alternative technologies more important than ever. Magnetic refrigeration utilizing the magnetocaloric effect of magnetic materials could be that alternative. However, there are still several challenges to be overcome before having devices that are competitive with those based on the conventional gas–vapor technology. In this paper a rigorous assessment of the most relevant examples of 14 different magnetocaloric material families is presented and those are compared in terms of their adiabatic temperature and isothermal entropy change under cycling in magnetic‐field changes of 1 and 2 T, criticality aspects, and the amount of heat that they can transfer per cycle. The work is based on magnetic, direct thermometric, and calorimetric measurements made under similar conditions and in the same devices. Such a wide‐ranging study has not been carried out before. This data sets the basis for more advanced modeling and machine learning approaches in the near future.


  • Ce and La as substitutes for Nd in Nd2Fe14B-based melt-spun alloys and hot-deformed magnets: a comparison of structural and magnetic properties

    by Iuliana Poenaru, Alexandru Lixandru, Stefan Riegg, Bahar Fayyazi, Andreas Taubel, Konrad Güth, Roland Gauß, Oliver Gutfleisch


  • A multicaloric cooling cycle that exploits thermal hysteresis

    by Tino Gottschall, Adrià Gràcia-Condal, Maximilian Fries, Andreas Taubel, Lukas Pfeuffer, Lluís Mañosa, Antoni Planes, Konstantin P. Skokov, Oliver Gutfleisch

    The giant magnetocaloric effect, in which large thermal changes are induced in a material on the application of a magnetic field, can be used for refrigeration applications, such as the cooling of systems from a small to a relatively large scale. However, commercial uptake is limited. We propose an approach to magnetic cooling that rejects the conventional idea that the hysteresis inherent in magnetostructural phase-change materials must be minimized to maximize the reversible magnetocaloric effect. Instead, we introduce a second stimulus, uniaxial stress, so that we can exploit the hysteresis. This allows us to lock-in the ferromagnetic phase as the magnetizing field is removed, which drastically removes the volume of the magnetic field source and so reduces the amount of expensive Nd–Fe–B permanent magnets needed for a magnetic refrigerator. In addition, the mass ratio between the magnetocaloric material and the permanent magnet can be increased, which allows scaling of the cooling power of a device simply by increasing the refrigerant body. The technical feasibility of this hysteresis-positive approach is demonstrated using Ni–Mn–In Heusler alloys. Our study could lead to an enhanced usage of the giant magnetocaloric effect in commercial applications.


  • Open Access

    Hysteresis Design of Magnetocaloric Materials—From Basic Mechanisms to Applications

    by Franziska Scheibel, Tino Gottschall, Andreas Taubel, Maximilian Fries, Konstantin P. Skokov, Alexandra Terwey, Werner Keune, Katharina Ollefs, Heiko Wende, Michael Farle, et al.

    Magnetic refrigeration relies on a substantial entropy change in a magnetocaloric material when a magnetic field is applied. Such entropy changes are present at first‐order magnetostructural transitions around a specific temperature at which the applied magnetic field induces a magnetostructural phase transition and causes a conventional or inverse magnetocaloric effect (MCE). First‐order magnetostructural transitions show large effects, but involve transitional hysteresis, which is a loss source that hinders the reversibility of the adiabatic temperature change ΔTad. However, reversibility is required for the efficient operation of the heat pump. Thus, it is the mastering of that hysteresis that is the key challenge to advance magnetocaloric materials. We review the origin of the large MCE and of the hysteresis in the most promising first‐order magnetocaloric materials such as Ni–Mn‐based Heusler alloys, FeRh, La(FeSi)13‐based compounds, Mn3GaC antiperovskites, and Fe2P compounds. We discuss the microscopic contributions of the entropy change, the magnetic interactions, the effect of hysteresis on the reversible MCE, and the size‐ and time‐dependence of the MCE at magnetostructural transitions.


  • Microstructural origin of hysteresis in Ni-Mn-In based magnetocaloric compounds

    by H. Sepehri-Amin, A. Taubel, T. Ohkubo, K.P. Skokov, O. Gutfleisch, K. Hono


  • A Comparative Study on the Magnetocaloric Properties of Ni‐Mn‐X(‐Co) Heusler Alloys

    by Andreas Taubel, Tino Gottschall, Maximilian Fries, Stefan Riegg, Christopher Soon, Konstantin P. Skokov, Oliver Gutfleisch

    We present a comprehensive study on three selected Heusler alloy systems. Ni‐Mn‐X(‐Co) systems with X = Al, In, Sn are compared with respect to the relevant magnetocaloric properties of their magnetostructural phase transition, namely martensitic transition temperature as well as its field dependence, magnetization change, and width of the thermal hysteresis. The latter one is strongly determining the reversibility of the magnetocaloric effect. Therefore the understanding of how to tailor it by extrinsic and intrinsic factors is of great importance. Our study of the magnetocaloric properties leads to the conclusion that the width of thermal hysteresis can be correlated to the magnetization change of the phase transition. Consequently, the adiabatic temperature change under cycling can largely vary despite similar values of isothermal entropy change for Ni‐Mn‐In‐Co and Ni‐Mn‐Sn‐Co. This result therefore shows the importance of tailoring sharpness, thermal hysteresis, and field dependence of the phase transition to achieve high values for the isothermal entropy change as well as a large magnetocaloric cooling effect in the different Heusler alloys.