Roman Sobolewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Roman Sobolewski has a total of 644 co-authors. Here are the top co-authors by number of shared publications:
- Martin Mikulics
Ernst-Ruska-Centre (ER-C-2), Forschungszentrum Jülich, 52425 Jülich, Germany
27 shared publications - Alexander Korneev
Institute of Nanotechnology of Microelectronics of the Russian Academy of Sciences
26 shared publications A. Pearlman
Univ. of Rochester (United States)
16 shared publicationsB. Voronov
Moscow State Pedagogical Univ. (Russia)
16 shared publicationsG. Chulkova
Moscow State Pedagogical Univ. (Russia)
16 shared publicationsK. Smirnov
Moscow State Pedagogical Univ. (Russia)
15 shared publications
Latest Publications
- Open Access
Laser-Induced Degradation of Bi2Se3 THz Emitters Revealed by Raman Spectroscopy
We present an investigation of the thermal damage threshold of passivated Bi2Se3 films upon laser illumination, with a focus on their employment in terahertz (THz) spectroscopic applications. Passivation was achieved by depositing a thin 3 nm Al capping layer which, exposed to the ambient, forms a natural oxide. In THz transient emission experiments, the samples were exposed to a train of 100 fs wide laser pulses with 800 nm wavelength at 78 MHz repetition rate and peak power density up to 295 mW/µm2. For the sake of comparison, the films were also exposed to continuous wave laser light with a wavelength of 532 nm in the average optical power density range from 5 × 10−2 mW/µm2 to 50 mW/µm2. In both cases, changes in film appearance, detected by optical microscopy, or even film removal in a small area close to the center of the illuminated spot could be induced. Raman spectroscopy provided evidence that the crystalline phase of Bi2Se3 films is present in areas that have been exposed but not damaged. Conversely, in the film region illuminated with the highest peak power density no Raman signal was detected in the range under investigation which we ascribe to material removal. At the perimeter of this ablated area, we observed a dominant Raman mode at approximately 255 cm−1 that we can attribute to selenium and indicates partial Bi2Se3 decomposition. In contrast, we observed Raman spectra corresponding to as-deposited Bi2Se3 only a few micrometers away from the laser-damaged area. Hence, the observed THz radiation originates from this illuminated but undamaged region. This detailed knowledge is expected to serve as a guide for designing the emitter’s thermal management and choosing laser parameters for optimal operation.
Open AccessLaser-Induced Degradation of Bi2Se3 THz Emitters Revealed by Raman Spectroscopy
We present an investigation of the thermal damage threshold of passivated Bi2Se3 films upon laser illumination, with a focus on their employment in terahertz (THz) spectroscopic applications. Passivation was achieved by depositing a thin 3 nm Al capping layer which, exposed to the ambient, forms a natural oxide. In THz transient emission experiments, the samples were exposed to a train of 100 fs wide laser pulses with 800 nm wavelength at 78 MHz repetition rate and peak power density up to 295 mW/µm2. For the sake of comparison, the films were also exposed to continuous wave laser light with a wavelength of 532 nm in the average optical power density range from 5 × 10−2 mW/µm2 to 50 mW/µm2. In both cases, changes in film appearance, detected by optical microscopy, or even film removal in a small area close to the center of the illuminated spot could be induced. Raman spectroscopy provided evidence that the crystalline phase of Bi2Se3 films is present in areas that have been exposed but not damaged. Conversely, in the film region illuminated with the highest peak power density no Raman signal was detected in the range under investigation which we ascribe to material removal. At the perimeter of this ablated area, we observed a dominant Raman mode at approximately 255 cm−1 that we can attribute to selenium and indicates partial Bi2Se3 decomposition. In contrast, we observed Raman spectra corresponding to as-deposited Bi2Se3 only a few micrometers away from the laser-damaged area. Hence, the observed THz radiation originates from this illuminated but undamaged region. This detailed knowledge is expected to serve as a guide for designing the emitter’s thermal management and choosing laser parameters for optimal operation.
- 1 January 2025
- Published by Optica Publishing Group
- p. AA138_5
Terahertz Time-Domain Spectroscopic Imaging of Hepatic Fibrosis in Rodent Livers
Terahertz time-domain imaging has been performed on hepatic fibrosis in rodent models of liver injury. Two-dimensional maps are generated using refractive index and absorption coefficient as imaging markers using a maximum a-posteriori probability estimation algorithm.
- 1 January 2025
- Published by Optica Publishing Group
- p. AA138_5
Terahertz Time-Domain Spectroscopic Imaging of Hepatic Fibrosis in Rodent Livers
Terahertz time-domain imaging has been performed on hepatic fibrosis in rodent models of liver injury. Two-dimensional maps are generated using refractive index and absorption coefficient as imaging markers using a maximum a-posteriori probability estimation algorithm.
- Open Access
High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors
Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.
Open AccessHigh-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors
Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.
- 1 January 2024
- Published by Optica Publishing Group
- p. FF2C.6
Coherent Acoustic Phonons in Bi2Se3 Ultrathin Films Probed by Femtosecond, Optical Pump-Probe Spectroscopy
The dynamics of coherent acoustic phonons in the Bi2Se3 layered crystal system are investigated. The findings reveal that the frequency evolution of breathing modes with the number of the material quintuple layers and the dispersion relation both can be explained by a modified chain model with a nonuniform coupling force.
- 1 January 2024
- Published by Optica Publishing Group
- p. FF2C.6
Coherent Acoustic Phonons in Bi2Se3 Ultrathin Films Probed by Femtosecond, Optical Pump-Probe Spectroscopy
The dynamics of coherent acoustic phonons in the Bi2Se3 layered crystal system are investigated. The findings reveal that the frequency evolution of breathing modes with the number of the material quintuple layers and the dispersion relation both can be explained by a modified chain model with a nonuniform coupling force.
- 1 January 2024
- Published by Optica Publishing Group
- p. ATh1B.4
Terahertz Time-Domain Imaging for Radiotherapy Treatment Monitoring in Pancreatic Ductal Adenocarcinoma
Terahertz time-domain imaging was performed of stereotactic body radiotherapy-treated murine pancreatic ductal adenocarcinoma (PDAC) with a high spatial resolution. To generate 2D maps of the tissue samples, the refractive index and absorption coefficient were used as imaging markers extracted with the maximum a-posteriori probability (MAP) estimation algorithm. The results were then compared with the terahertz maps of untreated murine PDAC tissue samples and demonstrated that terahertz imaging can probe physical changes with high sensitivity in the tissue post treatment.
- 1 January 2024
- Published by Optica Publishing Group
- p. ATh1B.4
Terahertz Time-Domain Imaging for Radiotherapy Treatment Monitoring in Pancreatic Ductal Adenocarcinoma
Terahertz time-domain imaging was performed of stereotactic body radiotherapy-treated murine pancreatic ductal adenocarcinoma (PDAC) with a high spatial resolution. To generate 2D maps of the tissue samples, the refractive index and absorption coefficient were used as imaging markers extracted with the maximum a-posteriori probability (MAP) estimation algorithm. The results were then compared with the terahertz maps of untreated murine PDAC tissue samples and demonstrated that terahertz imaging can probe physical changes with high sensitivity in the tissue post treatment.
- 20 December 2023
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 593
Terahertz inverse spin Hall effect in spintronic nanostructures with various ferromagnetic materials
- 20 December 2023
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 593
Terahertz inverse spin Hall effect in spintronic nanostructures with various ferromagnetic materials
- Open Access
Determination of Thermal Damage Threshold in THz Photomixers Using Raman Spectroscopy
The increase of device lifetime and reliability of THz photomixers will play an essential role in their possible future application. Therefore, their optimal work conditions/operation range, i.e., the maximal incident optical power should be experimentally estimated. We fabricated and tested THz photomixer devices based on nitrogen-implanted GaAs integrated with a Bragg reflector. Raman spectroscopy was applied to investigate the material properties and to disclose any reversible or irreversible material changes. The results indicate that degradation effects in the photomixer structures/material could be avoided if the total optical power density does not exceed levels of about 0.7 mW/µm2 for 100 min of operation. Furthermore, the investigations performed during 1000 min of optical exposure on the photomixer devices’ central region comprising interdigitated metal-semiconductor-metal (MSM) structures suggest a reversible “curing” mechanism if the power density level of ~0.58 mW/µm2 is not exceeded. Long-term operation (up to 1000 h) reveals that the photomixer structures can withstand an average optical power density of up to ~0.4 mW/µm2 without degradation when biased at 10 V. Besides the decrease of the position of the A1g (LO) Raman mode from ~291 cm−1 down to ~288 cm−1 with increasing optical power density and operation time, broad Raman modes evolve at about 210 cm−1, which can be attributed to degradation effects in the active photomixer/MSM area. In addition, the performed carrier lifetime and photomixer experiments demonstrated that these structures generated continuous wave sub-THz radiation efficiently as long as their optimal work conditions/operation range were within the limits established by our Raman studies.
Open AccessDetermination of Thermal Damage Threshold in THz Photomixers Using Raman Spectroscopy
The increase of device lifetime and reliability of THz photomixers will play an essential role in their possible future application. Therefore, their optimal work conditions/operation range, i.e., the maximal incident optical power should be experimentally estimated. We fabricated and tested THz photomixer devices based on nitrogen-implanted GaAs integrated with a Bragg reflector. Raman spectroscopy was applied to investigate the material properties and to disclose any reversible or irreversible material changes. The results indicate that degradation effects in the photomixer structures/material could be avoided if the total optical power density does not exceed levels of about 0.7 mW/µm2 for 100 min of operation. Furthermore, the investigations performed during 1000 min of optical exposure on the photomixer devices’ central region comprising interdigitated metal-semiconductor-metal (MSM) structures suggest a reversible “curing” mechanism if the power density level of ~0.58 mW/µm2 is not exceeded. Long-term operation (up to 1000 h) reveals that the photomixer structures can withstand an average optical power density of up to ~0.4 mW/µm2 without degradation when biased at 10 V. Besides the decrease of the position of the A1g (LO) Raman mode from ~291 cm−1 down to ~288 cm−1 with increasing optical power density and operation time, broad Raman modes evolve at about 210 cm−1, which can be attributed to degradation effects in the active photomixer/MSM area. In addition, the performed carrier lifetime and photomixer experiments demonstrated that these structures generated continuous wave sub-THz radiation efficiently as long as their optimal work conditions/operation range were within the limits established by our Raman studies.
- Open Access
- 8 March 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (11) , 9925-9933
Development of Terahertz Imaging Markers for Pancreatic Ductal Adenocarcinoma using Maximum A Posteriori Probability (MAP) Estimation
Pancreatic ductal adenocarcinoma (PDAC) is one of the significant reasons for cancer-related death in the United States due to a lack of timely prognosis and the poor efficacy of the standard treatment protocol. Immunotherapy-based neoadjuvant therapy, such as stereotactic body radiotherapy (SBRT), has shown promising results compared to conventional radiotherapy in strengthening the antitumor response in PDAC. To probe and quantify the antitumor response with SBRT, we propose to study the tumor microenvironment using terahertz time-domain spectroscopy (THz-TDS). Since the tumor's complex microenvironment plays a key role in disease progression and treatment supervision, THz-TDS can be a revolutionary tool to help in treatment planning by probing the changes in the tissue microenvironment. This paper presents THz-TDS of paraffin-embedded PDAC samples utilizing a clinically relevant genetically engineered mouse model. This Article aims to develop and validate a novel time domain approximation method based on maximum a posteriori probability (MAP) estimation to extract terahertz parameters, namely, the refractive index and the absorption coefficient, from THz-TDS. Unlike the standard frequency-domain (FD) analysis, the parameters extracted from MAP construct better-conserved tissue parameters estimates, since the FD optimization often incorporates errors due to numerical instabilities during phase unwrapping, especially when propagating in lossy media. The THzrange index of refraction extracted from MAP and absorption coefficient parameters report a statistically significant distinction between PDAC tissue regions and their healthy equivalents. The coefficient of variation of the refractive index extracted by MAP is one order of magnitude lower compared to the one extracted from FD analysis. The index of refraction and absorption coefficient extracted from the MAP are suggested as the best imaging markers to reconstruct THz images of biological tissues to reflect their physical properties accurately and reproducibly. The obtained THz scans were validated using standard histopathology.
- 8 March 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (11) , 9925-9933
Open AccessDevelopment of Terahertz Imaging Markers for Pancreatic Ductal Adenocarcinoma using Maximum A Posteriori Probability (MAP) Estimation
Pancreatic ductal adenocarcinoma (PDAC) is one of the significant reasons for cancer-related death in the United States due to a lack of timely prognosis and the poor efficacy of the standard treatment protocol. Immunotherapy-based neoadjuvant therapy, such as stereotactic body radiotherapy (SBRT), has shown promising results compared to conventional radiotherapy in strengthening the antitumor response in PDAC. To probe and quantify the antitumor response with SBRT, we propose to study the tumor microenvironment using terahertz time-domain spectroscopy (THz-TDS). Since the tumor's complex microenvironment plays a key role in disease progression and treatment supervision, THz-TDS can be a revolutionary tool to help in treatment planning by probing the changes in the tissue microenvironment. This paper presents THz-TDS of paraffin-embedded PDAC samples utilizing a clinically relevant genetically engineered mouse model. This Article aims to develop and validate a novel time domain approximation method based on maximum a posteriori probability (MAP) estimation to extract terahertz parameters, namely, the refractive index and the absorption coefficient, from THz-TDS. Unlike the standard frequency-domain (FD) analysis, the parameters extracted from MAP construct better-conserved tissue parameters estimates, since the FD optimization often incorporates errors due to numerical instabilities during phase unwrapping, especially when propagating in lossy media. The THzrange index of refraction extracted from MAP and absorption coefficient parameters report a statistically significant distinction between PDAC tissue regions and their healthy equivalents. The coefficient of variation of the refractive index extracted by MAP is one order of magnitude lower compared to the one extracted from FD analysis. The index of refraction and absorption coefficient extracted from the MAP are suggested as the best imaging markers to reconstruct THz images of biological tissues to reflect their physical properties accurately and reproducibly. The obtained THz scans were validated using standard histopathology.
- 3 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (3) , 286-291
Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications
We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in free-electron laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, x-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and x-ray cross correlation, the material must have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 10-90 nA range for voltages to even 1000 V. Hence the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1-x Mg x Te material is presented. Other characterization and transient measurements are discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.
- 3 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (3) , 286-291
Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications
We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in free-electron laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, x-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and x-ray cross correlation, the material must have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 10-90 nA range for voltages to even 1000 V. Hence the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1-x Mg x Te material is presented. Other characterization and transient measurements are discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.
- 1 January 2023
- Published by Optica Publishing Group
- p. AW4Q.6
High Spatial Resolution Terahertz Time-Domain Imaging of Murine Pancreatic Ductal Adenocarcinoma Tissues
We developed a terahertz time-domain spectroscopy system to generate high-resolution 2-dimensional images of paraffin-embedded murine pancreatic ductal adenocarcinoma tissues using the refractive index and absorption coefficient as imaging markers and compared them with histopathological images.
- 1 January 2023
- Published by Optica Publishing Group
- p. AW4Q.6
High Spatial Resolution Terahertz Time-Domain Imaging of Murine Pancreatic Ductal Adenocarcinoma Tissues
We developed a terahertz time-domain spectroscopy system to generate high-resolution 2-dimensional images of paraffin-embedded murine pancreatic ductal adenocarcinoma tissues using the refractive index and absorption coefficient as imaging markers and compared them with histopathological images.