Erich Sorantin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Erich Sorantin has a total of 191 co-authors. Here are the top co-authors by number of shared publications:
- Sebastian Tschauner
Division of Pediatric Radiology, Department of Radiology, Medical University of Graz, Graz, Austria
14 shared publications - Eszter Nagy
Division of Paediatric Radiology, Department of Radiology, Medical University of Graz, Graz, Austria
5 shared publications - Franko Hržić
Center for Artificial Intelligence and Cybersecurity, University of Rijeka, Rijeka, Croatia
5 shared publications - Georg Singer
Department of Paediatric and Adolescent Surgery, Medical University of Graz, 8010 Graz, Austria
5 shared publications - Holger Till
Department of Paediatric and Adolescent Surgery, Medical University of Graz, 8010 Graz, Austria
4 shared publications - Ivan Štajduhar
Faculty of Engineering, University of Rijeka, 51000 Rijeka, Croatia
4 shared publications
Latest Publications
- Open Access
- 25 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2712
Lung Ultrasound-Guided Non-Fiberobronchoscopic Bronchoalveolar Lavage for Neonatal Atelectatic Pulmonary Disease Treatment: Clinical Practice Guidelines Based on International Expert Consensus
Severe pulmonary diseases, including atelectasis, pneumonia, and meconium aspiration syndrome, are major causes of neonatal respiratory distress, weaning difficulties, ventilator or oxygen dependence, prolonged oxygen requirements, extended hospitalization, and poor prognosis. The lack of simple and effective treatment strategies seriously endangers the survival and health of newborns, particularly premature infants. Recent advances in lung ultrasound (LUS) technology have made LUS-guided non-fiberobronchoscopic bronchoalveolar lavage (NFB-BAL) a promising solution. This approach addresses the limitations of conventional BAL in neonates by enabling accurate diagnosis, precise lesion localization, and dynamic procedural monitoring, hence reducing complications. Based on international expert consensus, these guidelines were developed to improve knowledge and promote the application of this technology and enhance operational standardization to ensure its effectiveness and safety. These guidelines contain 17 recommendations on 13 key clinical issues for reference and implementation in clinical practice. The wide application of these guidelines is expected to help significantly improve the prognosis of critically ill newborns with atelectatic pulmonary diseases.
- 25 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2712
Open AccessLung Ultrasound-Guided Non-Fiberobronchoscopic Bronchoalveolar Lavage for Neonatal Atelectatic Pulmonary Disease Treatment: Clinical Practice Guidelines Based on International Expert Consensus
Severe pulmonary diseases, including atelectasis, pneumonia, and meconium aspiration syndrome, are major causes of neonatal respiratory distress, weaning difficulties, ventilator or oxygen dependence, prolonged oxygen requirements, extended hospitalization, and poor prognosis. The lack of simple and effective treatment strategies seriously endangers the survival and health of newborns, particularly premature infants. Recent advances in lung ultrasound (LUS) technology have made LUS-guided non-fiberobronchoscopic bronchoalveolar lavage (NFB-BAL) a promising solution. This approach addresses the limitations of conventional BAL in neonates by enabling accurate diagnosis, precise lesion localization, and dynamic procedural monitoring, hence reducing complications. Based on international expert consensus, these guidelines were developed to improve knowledge and promote the application of this technology and enhance operational standardization to ensure its effectiveness and safety. These guidelines contain 17 recommendations on 13 key clinical issues for reference and implementation in clinical practice. The wide application of these guidelines is expected to help significantly improve the prognosis of critically ill newborns with atelectatic pulmonary diseases.
- Open Access
- 30 August 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (3) , 420-428
Let us talk about mistakes
Unfortunately, errors and mistakes are part of life. Errors and mistakes can harm patients and incur unplanned costs. Errors may arise from various sources, which may be classified as systematic, latent, or active. Intrinsic and extrinsic factors also contribute to incorrect decisions. In addition to cognitive biases, our personality, socialization, personal chronobiology, and way of thinking (heuristic versus analytical) are influencing factors. Factors such as overload from private situations, long commuting times, and the complex environment of information technology must also be considered. The objective of this paper is to define and classify errors and mistakes in radiology, to discuss the influencing factors, and to present strategies for prevention. Hierarchical responsibilities and team “well-being” are also discussed.
- 30 August 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (3) , 420-428
Open AccessLet us talk about mistakes
Unfortunately, errors and mistakes are part of life. Errors and mistakes can harm patients and incur unplanned costs. Errors may arise from various sources, which may be classified as systematic, latent, or active. Intrinsic and extrinsic factors also contribute to incorrect decisions. In addition to cognitive biases, our personality, socialization, personal chronobiology, and way of thinking (heuristic versus analytical) are influencing factors. Factors such as overload from private situations, long commuting times, and the complex environment of information technology must also be considered. The objective of this paper is to define and classify errors and mistakes in radiology, to discuss the influencing factors, and to present strategies for prevention. Hierarchical responsibilities and team “well-being” are also discussed.
- 3 August 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (3) , 386-396
Let’s talk about radiation dose and radiation protection in children
Children are more sensitive to ionizing radiation than adults. Even though the risk is very low, exposure from radiological examinations can possibly cause them long-term side effects. Recent large epidemiological studies involving children and young adults have added evidence suggesting that even small doses of radiation, such as those from computed tomography scans, might slightly increase the risk of developing cancer later in life. Therefore, even though radiologic studies are essential for an accurate diagnosis and management of various conditions, it is crucial to minimize radiation exposure. This article addresses radiation protection for children in the medical use of ionizing radiation and it is set in the context of the European legislative framework regarding radiation protection. It advocates for a holistic approach to paediatric radiological tests. This approach includes the key principles of radiation protection, such as the justification of imaging procedures supported by referral guidelines, as well as the optimization of techniques (according to the ALARA principle) and effective communication with parents about the benefits and the risks of radiologic procedures. Protecting children from unnecessary radiation is not only a technical challenge, but also a moral obligation and a legal requirement. Graphical Abstract
- 3 August 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (3) , 386-396
Let’s talk about radiation dose and radiation protection in children
Children are more sensitive to ionizing radiation than adults. Even though the risk is very low, exposure from radiological examinations can possibly cause them long-term side effects. Recent large epidemiological studies involving children and young adults have added evidence suggesting that even small doses of radiation, such as those from computed tomography scans, might slightly increase the risk of developing cancer later in life. Therefore, even though radiologic studies are essential for an accurate diagnosis and management of various conditions, it is crucial to minimize radiation exposure. This article addresses radiation protection for children in the medical use of ionizing radiation and it is set in the context of the European legislative framework regarding radiation protection. It advocates for a holistic approach to paediatric radiological tests. This approach includes the key principles of radiation protection, such as the justification of imaging procedures supported by referral guidelines, as well as the optimization of techniques (according to the ALARA principle) and effective communication with parents about the benefits and the risks of radiologic procedures. Protecting children from unnecessary radiation is not only a technical challenge, but also a moral obligation and a legal requirement. Graphical Abstract
- Open Access
- 20 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 25
Bismuth Shielding in Head Computed Tomography—Still Necessary?
Introduction: Cranial CT scans are associated with radiation exposure to the eye lens, which is a particularly radiosensitive organ. Children are more vulnerable to radiation than adults. Therefore, it is essential to use the available dose reduction techniques to minimize radiation exposure. According to the European Consensus on patient contact shielding by the IRCP from 2021, shielding is not recommended in most body areas anymore. This study aims to evaluate whether bismuth shielding as well as its combination with other dose-saving technologies could still be useful. Methods: Cranial CT scans of a pediatric anthropomorphic phantom were performed on two up-to-date MDCT scanners. Eye lens dose measurements were performed using thermoluminescent dosimeters. Furthermore, the impact of BS and of the additional placement of standoff foam between the patient and BS on image quality was also assessed. Results: Bismuth shielding showed a significant lens dose reduction in both CT scanners (GE: 41.50 ± 4.04%, p < 0.001; Siemens: 29.75 ± 6.55%, p = 0.00). When combined with AEC, the dose was lowered even more (GE: 60.75 ± 3.30%, p < 0.001; Siemens: 41.25 ± 8.02%, p = 0.00). The highest eye dose reduction was achieved using BS + AEC + OBTCM (GE: 71.25 ± 2.98%, p < 0.001; Siemens: 58.75 ± 5.85%, p < 0.001). BS caused increased image noise in the orbital region, which could be mitigated by foam placement. Eye shielding had no effect on the image noise in the cranium. Conclusions: The use of BS in cranial CT can lead to a significant dose reduction, which can be further enhanced by its combination with other modern dose reduction methods. BS causes increase in image noise in the orbital region but not in the cranium. The additional use of standoff foam reduces image noise in the orbital region.
- 20 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 25
Open AccessBismuth Shielding in Head Computed Tomography—Still Necessary?
Introduction: Cranial CT scans are associated with radiation exposure to the eye lens, which is a particularly radiosensitive organ. Children are more vulnerable to radiation than adults. Therefore, it is essential to use the available dose reduction techniques to minimize radiation exposure. According to the European Consensus on patient contact shielding by the IRCP from 2021, shielding is not recommended in most body areas anymore. This study aims to evaluate whether bismuth shielding as well as its combination with other dose-saving technologies could still be useful. Methods: Cranial CT scans of a pediatric anthropomorphic phantom were performed on two up-to-date MDCT scanners. Eye lens dose measurements were performed using thermoluminescent dosimeters. Furthermore, the impact of BS and of the additional placement of standoff foam between the patient and BS on image quality was also assessed. Results: Bismuth shielding showed a significant lens dose reduction in both CT scanners (GE: 41.50 ± 4.04%, p < 0.001; Siemens: 29.75 ± 6.55%, p = 0.00). When combined with AEC, the dose was lowered even more (GE: 60.75 ± 3.30%, p < 0.001; Siemens: 41.25 ± 8.02%, p = 0.00). The highest eye dose reduction was achieved using BS + AEC + OBTCM (GE: 71.25 ± 2.98%, p < 0.001; Siemens: 58.75 ± 5.85%, p < 0.001). BS caused increased image noise in the orbital region, which could be mitigated by foam placement. Eye shielding had no effect on the image noise in the cranium. Conclusions: The use of BS in cranial CT can lead to a significant dose reduction, which can be further enhanced by its combination with other modern dose reduction methods. BS causes increase in image noise in the orbital region but not in the cranium. The additional use of standoff foam reduces image noise in the orbital region.
- Open Access
- 19 September 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 54 (4) , 505-515
Integrative diagnostics of the gastro-intestinal tract – gastroesophageal reflux and constipation in practice
Common disorders of the gastrointestinal (GI) tract, such as gastroesophageal reflux/disease (GER/D) and constipation, are frequent causes for seeking medical support in infants. Diagnostic workup must ensure that diagnosed diseases are responsible for such complaints, thus enabling appropriate therapy. In this context assessment consists of clinical examination, functional tests, and imaging, which should be done in a staged manner. Close cooperation between clinicians and clinical radiologists enables optimal diagnostics, thus forming the basis for appropriate therapy.
- 19 September 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 54 (4) , 505-515
Open AccessIntegrative diagnostics of the gastro-intestinal tract – gastroesophageal reflux and constipation in practice
Common disorders of the gastrointestinal (GI) tract, such as gastroesophageal reflux/disease (GER/D) and constipation, are frequent causes for seeking medical support in infants. Diagnostic workup must ensure that diagnosed diseases are responsible for such complaints, thus enabling appropriate therapy. In this context assessment consists of clinical examination, functional tests, and imaging, which should be done in a staged manner. Close cooperation between clinicians and clinical radiologists enables optimal diagnostics, thus forming the basis for appropriate therapy.
- 29 June 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (10) , 2159-2160
Reply to Mese I
- 29 June 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (10) , 2159-2160
Reply to Mese I
- Open Access
- 28 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 68257-68268
Effects of Patient Recumbency Position on Neonatal Chest EIT
This paper investigates the overlooked effects of the patient recumbency positions on one of the key clinically used parameters in chest electrical impedance tomography (EIT) monitoring – the silent spaces. This parameter could impact medical decisions and interventions by indicating how well each lung is being ventilated. Yet it is largely dependent on assumptions of prior model at the reconstruction stage and the closely linked region of interest (ROI) during the final calculations. The potential effect of switching recumbency modes on silent spaces as a results of internal organ movements and consequently changes in initial assumptions, has been studied. The displacement and deformations caused by posture changes from supine to lateral recumbent were evaluated via simulations considering the simultaneous gravity-dependent movement and/or deformations of heart, mediastinum, lungs and the diaphragm. The reliability of simulations was verified against reference radiography images of an 18-month-old infant in supine and decubitus lateral positions. Inspecting a set of 10 patients from age range of 1 to 2 years old revealed improvements of up to 30% in the silent space parameters when applying posture consistent amendments as opposed to fixed model/ROI to each individual. To minimize the influence of image reconstruction technique on the results two different EIT reconstruction algorithms were implemented. The outcome emphasized the importance of including recumbency situation during chest EIT monitoring within the considered age range.
- 28 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 68257-68268
Open AccessEffects of Patient Recumbency Position on Neonatal Chest EIT
This paper investigates the overlooked effects of the patient recumbency positions on one of the key clinically used parameters in chest electrical impedance tomography (EIT) monitoring – the silent spaces. This parameter could impact medical decisions and interventions by indicating how well each lung is being ventilated. Yet it is largely dependent on assumptions of prior model at the reconstruction stage and the closely linked region of interest (ROI) during the final calculations. The potential effect of switching recumbency modes on silent spaces as a results of internal organ movements and consequently changes in initial assumptions, has been studied. The displacement and deformations caused by posture changes from supine to lateral recumbent were evaluated via simulations considering the simultaneous gravity-dependent movement and/or deformations of heart, mediastinum, lungs and the diaphragm. The reliability of simulations was verified against reference radiography images of an 18-month-old infant in supine and decubitus lateral positions. Inspecting a set of 10 patients from age range of 1 to 2 years old revealed improvements of up to 30% in the silent space parameters when applying posture consistent amendments as opposed to fixed model/ROI to each individual. To minimize the influence of image reconstruction technique on the results two different EIT reconstruction algorithms were implemented. The outcome emphasized the importance of including recumbency situation during chest EIT monitoring within the considered age range.
- 14 June 2023
- Published by Springer Nature
- p. 253-280
Imaging the Neonatal Heart and Large Vessels
- Open Access
- 17 March 2023
- Published by Springer Nature
- p. 277-289
Congenital and Acquired Pathologies of the Pediatric Urogenital Tract
The aim of imaging in children with congenital and acquired abnormalities of the genitourinary system is to increase the quality of care by establishing an accurate diagnosis and guiding the child’s management. Pediatric urological conditions are diverse with many different approaches to imaging and management. We will present a concise overview of the most important and common congenital and acquired disorders of the pediatric urogenital tract.
- 17 March 2023
- Published by Springer Nature
- p. 277-289
Open AccessCongenital and Acquired Pathologies of the Pediatric Urogenital Tract
The aim of imaging in children with congenital and acquired abnormalities of the genitourinary system is to increase the quality of care by establishing an accurate diagnosis and guiding the child’s management. Pediatric urological conditions are diverse with many different approaches to imaging and management. We will present a concise overview of the most important and common congenital and acquired disorders of the pediatric urogenital tract.
- 7 January 2023
- Published by Springer Nature
- p. 993-1000
Intussusception