Jianhua Zhang
Jianhua Zhang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Qing Huo Liu
Eastern Institute of Technology
5 shared publications Linying Liu
Institute of Electromagnetics and Acoustics, and Department of Electronic Science, Xiamen University, Xiamen, 361005, P. R. China.
2 shared publicationsNa Liu
Institute of Electromagnetics and Acoustics, and Department of Electronic Science, Xiamen University, Xiamen, 361005, P. R. China.
2 shared publicationsXiaowei Zhao
Institute of Electromagnetics and Acoustics, and Department of Electronic Science, Xiamen University, Xiamen, 361005, P. R. China.
2 shared publicationsZheng Mao
Institute of Electromagnetics and Acoustics, and Department of Electronic Science, Xiamen University, Xiamen, 361005, P. R. China.
2 shared publications- Zheng Mao
College of Information and Communication Engineering, Nanjing Institute of Technology, Nanjing, China
2 shared publications
Latest Publications
- Open Access
- 5 July 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (38) , 23589-23596
The transport of a charged peptide through carbon nanotubes under an external electric field: a molecular dynamics simulation
The study of interactions between biomolecules and carbon nanotubes (CNTs) is of great importance in CNT-based drug delivery systems and biomedical devices. In this work, the transport of polyarginine (R8) peptide through CNTs under an external electric field was investigated via all-atom molecular dynamics (AAMD) simulation. It was found that the electric field can assist the R8 peptide to overcome the resistance and make the transport smooth. Moreover, the efficiency of transport was improved with the increasing intensity of the electric field in a suitable range. In addition, we also investigated the effects of different types of CNTs on the transport of the R8 peptide and found that the single-walled carbon nanotube (SWCNT) was more suitable for transporting the R8 peptide than the double-walled carbon nanotube (DWCNT) due to its lower energy barrier to the R8 peptide. All these findings shed light on the role of the electric field on the transport of the R8 peptide through CNTs and also gave some valuable insights into the effects of CNT types on the transport process of the peptide.
- 5 July 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (38) , 23589-23596
Open AccessThe transport of a charged peptide through carbon nanotubes under an external electric field: a molecular dynamics simulation
The study of interactions between biomolecules and carbon nanotubes (CNTs) is of great importance in CNT-based drug delivery systems and biomedical devices. In this work, the transport of polyarginine (R8) peptide through CNTs under an external electric field was investigated via all-atom molecular dynamics (AAMD) simulation. It was found that the electric field can assist the R8 peptide to overcome the resistance and make the transport smooth. Moreover, the efficiency of transport was improved with the increasing intensity of the electric field in a suitable range. In addition, we also investigated the effects of different types of CNTs on the transport of the R8 peptide and found that the single-walled carbon nanotube (SWCNT) was more suitable for transporting the R8 peptide than the double-walled carbon nanotube (DWCNT) due to its lower energy barrier to the R8 peptide. All these findings shed light on the role of the electric field on the transport of the R8 peptide through CNTs and also gave some valuable insights into the effects of CNT types on the transport process of the peptide.
- 14 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Multiscale and Multiphysics Computational Techniques
- Vol. 3, 235-245
Selective Electroporation of Organelles Under an Intense Picosecond Pulsed Electric Field
A high-intensity electric pulse with sub-nanosecond and picosecond durations may induce electroporation of an intracellular organelle while the integrity of plasma membrane in a biological cell remains intact. In this paper, the induced transmembrane voltage (TMV) and pore formation dynamics on the biological cell membrane are comparatively analyzed when the cell is exposed to sufficiently intense electric pulses of nanosecond and picosecond durations, respectively. From our results, selective electroporation of organelles can be clearly observed when the cell is affected by an intense picosecond electric pulse. In contrast, the electric pulse of a few hundred nanosecond duration can electroporate the plasma membrane of biological cell much before organelle membranes regardless of the magnitude of the pulse. By regulating the intensity of electric pulse with two different durations, effective pulse parameters can be obtained to realize selective electroporation of intracellular organelles or plasma membrane. Our study demonstrates the selective electroporation of organelles of intense picosecond electric pulse and may provide guidance for further development in experimental and theoretical research. Furthermore, the applicability of the quasi-static model used to calculate the TMV under the stimulation of a few hundred picosecond electric pulse is firstly illustrated in this paper.
- 14 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Multiscale and Multiphysics Computational Techniques
- Vol. 3, 235-245
Selective Electroporation of Organelles Under an Intense Picosecond Pulsed Electric Field
A high-intensity electric pulse with sub-nanosecond and picosecond durations may induce electroporation of an intracellular organelle while the integrity of plasma membrane in a biological cell remains intact. In this paper, the induced transmembrane voltage (TMV) and pore formation dynamics on the biological cell membrane are comparatively analyzed when the cell is exposed to sufficiently intense electric pulses of nanosecond and picosecond durations, respectively. From our results, selective electroporation of organelles can be clearly observed when the cell is affected by an intense picosecond electric pulse. In contrast, the electric pulse of a few hundred nanosecond duration can electroporate the plasma membrane of biological cell much before organelle membranes regardless of the magnitude of the pulse. By regulating the intensity of electric pulse with two different durations, effective pulse parameters can be obtained to realize selective electroporation of intracellular organelles or plasma membrane. Our study demonstrates the selective electroporation of organelles of intense picosecond electric pulse and may provide guidance for further development in experimental and theoretical research. Furthermore, the applicability of the quasi-static model used to calculate the TMV under the stimulation of a few hundred picosecond electric pulse is firstly illustrated in this paper.
- Open Access
- 6 July 2018
- Published by Springer Nature in Discover Nano
- Vol. 13 (1) , 199
Electronic Properties of Vanadium Atoms Adsorption on Clean and Graphene-Covered Cu(111) Surface
The electronic properties of vanadium atoms adsorbed on clean and graphene-covered Cu(111) surface have been systematically studied using ab initio theoretical method. Two coverages (1/9 ML and 1 ML) of vanadium adsorption are considered in this work. Our calculations indicate that V staying underneath the Cu surface is found to be the most stable adsorption site at the aforementioned two coverages for V/Cu(111). However, such adsorption may lead to undesired properties. Therefore, we introduce graphene as a buffer layer to effectively alleviate the direct interaction between V and Cu surface. The calculations show that electronic properties of the original graphene layer are significantly affected by the interactions of C atoms with the V adatoms; the Dirac point of graphene is “destroyed” as a consequence at both coverages. In the V/Gra/Cu(111) system, the interaction between graphene layer and the substrate Cu atoms remains weak as in the Gra/Cu(111) system. Moreover, a relatively low coverage of 1/9 ML gives rise to a spin-polarized system while a non-spin-polarized system is observed at the coverage of 1 ML. This finding offers a new way for the application of vanadium-based materials in reality.
- 6 July 2018
- Published by Springer Nature in Discover Nano
- Vol. 13 (1) , 199
Open AccessElectronic Properties of Vanadium Atoms Adsorption on Clean and Graphene-Covered Cu(111) Surface
The electronic properties of vanadium atoms adsorbed on clean and graphene-covered Cu(111) surface have been systematically studied using ab initio theoretical method. Two coverages (1/9 ML and 1 ML) of vanadium adsorption are considered in this work. Our calculations indicate that V staying underneath the Cu surface is found to be the most stable adsorption site at the aforementioned two coverages for V/Cu(111). However, such adsorption may lead to undesired properties. Therefore, we introduce graphene as a buffer layer to effectively alleviate the direct interaction between V and Cu surface. The calculations show that electronic properties of the original graphene layer are significantly affected by the interactions of C atoms with the V adatoms; the Dirac point of graphene is “destroyed” as a consequence at both coverages. In the V/Gra/Cu(111) system, the interaction between graphene layer and the substrate Cu atoms remains weak as in the Gra/Cu(111) system. Moreover, a relatively low coverage of 1/9 ML gives rise to a spin-polarized system while a non-spin-polarized system is observed at the coverage of 1 ML. This finding offers a new way for the application of vanadium-based materials in reality.
- 27 October 2016
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 18 (46) , 31946-31957
Interaction between charged nanoparticles and vesicles: coarse-grained molecular dynamics simulations
Interactions between charged nanoparticles and curved zwitterionic lipid vesicles with different surface charge densities (ρ): insertion, repulsion, adsorption, and penetration.
- 27 October 2016
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 18 (46) , 31946-31957
Interaction between charged nanoparticles and vesicles: coarse-grained molecular dynamics simulations
Interactions between charged nanoparticles and curved zwitterionic lipid vesicles with different surface charge densities (ρ): insertion, repulsion, adsorption, and penetration.
- 7 September 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (93) , 90388-90396
Interactions between C60and vesicles: a coarse-grained molecular dynamics simulation
Fullerene (C60) prefers to stay in the head group region of the inner leaflet of a vesicle after penetration.
- 7 September 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (93) , 90388-90396
Interactions between C60and vesicles: a coarse-grained molecular dynamics simulation
Fullerene (C60) prefers to stay in the head group region of the inner leaflet of a vesicle after penetration.
- Open Access
- 8 July 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (7) , e0158739
The Influence of Vesicle Shape and Medium Conductivity on Possible Electrofusion under a Pulsed Electric Field
The effects of electric field on lipid membrane and cells have been extensively studied in the last decades. The phenomena of electroporation and electrofusion are of particular interest due to their wide use in cell biology and biotechnology. However, numerical studies on the electrofusion of cells (or vesicles) with different deformed shapes are still rare. Vesicle, being of cell size, can be treated as a simple model of cell to investigate the behaviors of cell in electric field. Based on the finite element method, we investigate the effect of vesicle shape on electrofusion of contact vesicles in various medium conditions. The transmembrane voltage (TMV) and pore density induced by a pulsed field are examined to analyze the possibility of vesicle fusion. In two different medium conditions, the prolate shape is observed to have selective electroporation at the contact area of vesicles when the exterior conductivity is smaller than the interior one; selective electroporation is more inclined to be found at the poles of the oblate vesicles when the exterior conductivity is larger than the interior one. Furthermore, we find that when the exterior conductivity is lower than the internal conductivity, the pulse can induce a selective electroporation at the contact area between two vesicles regardless of the vesicle shape. Both of these two findings have important practical applications in guiding electrofusion experiments.
- 8 July 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (7) , e0158739
Open AccessThe Influence of Vesicle Shape and Medium Conductivity on Possible Electrofusion under a Pulsed Electric Field
The effects of electric field on lipid membrane and cells have been extensively studied in the last decades. The phenomena of electroporation and electrofusion are of particular interest due to their wide use in cell biology and biotechnology. However, numerical studies on the electrofusion of cells (or vesicles) with different deformed shapes are still rare. Vesicle, being of cell size, can be treated as a simple model of cell to investigate the behaviors of cell in electric field. Based on the finite element method, we investigate the effect of vesicle shape on electrofusion of contact vesicles in various medium conditions. The transmembrane voltage (TMV) and pore density induced by a pulsed field are examined to analyze the possibility of vesicle fusion. In two different medium conditions, the prolate shape is observed to have selective electroporation at the contact area of vesicles when the exterior conductivity is smaller than the interior one; selective electroporation is more inclined to be found at the poles of the oblate vesicles when the exterior conductivity is larger than the interior one. Furthermore, we find that when the exterior conductivity is lower than the internal conductivity, the pulse can induce a selective electroporation at the contact area between two vesicles regardless of the vesicle shape. Both of these two findings have important practical applications in guiding electrofusion experiments.