LWLauren Watkins

Lauren Watkins

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lauren Watkins has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Physiologic Medial Meniscal Extrusion With Loading and Flexion Detected by Ultrasound

    by Maria E. Dey Hazra, Rony-Orijit Dey Hazra, Amelia Kruse, Adam Bradshaw, Justin Hollenbeck, Peter J. Millett, Armando Vidal, Scott Tashman, Lauren E. Watkins

    Background: Medial meniscal extrusion (MME) is a risk factor for osteoarthritis of the knee and is usually assessed using a supine, unloaded magnetic resonance imaging. However, protocols for examining meniscal extrusion with ultrasound in the literature vary regarding specific flexion angles and the extent of weightbearing during the examination, complicating interpretations of the influence of loading and position on meniscal extrusion. Hypothesis: The hypothesis was that loading and increased flexion angles would increase physiologic MME relative to supine and neutral positions. Study Design: Descriptive laboratory study. Methods: Asymptomatic volunteers with no history of knee pain, injury, or surgery were included. Real-time knee joint angles were obtained by a motion-capture system using retroreflective markers placed on the lower limbs. Ultrasound images of the medial meniscus of both knees were acquired in the coronal plane for supine, single-leg, and double-leg standing positions and with the knee in neutral (0°-5°), 20°, and 45° of flexion. MME was compared across legs, stances, and angles using a repeated-measures mixed-effects linear model, and pairwise comparisons were made using a post hoc Tukey test. Results: A total of 21 volunteers (age, 33 ± 12 years; body mass index, 23 ± 2.3 kg/m 2 ; 9 women) participated in the study. MME was significantly lower in the supine position compared with single- and double-leg stances ( P < .0001, estimated marginal mean MME: supine = 1.1, 1-leg = 1.3, 2-leg = 1.3), with no significant difference between weightbearing stances. Increasing knee flexion angles were associated with significantly lower extrusion ( P < .0001, estimated marginal mean MME: neutral = 1.4; 20° = 1.3; 45° = 1), with extrusion greatest at neutral flexion and lowest at 45° of flexion. There was no significant difference in MME between right and left legs (estimated marginal mean MME = 1.2 for both left and right legs; P = .7255). Conclusion: Our study demonstrated that unloaded, supine examinations of MME may be of limited value. Also, including ultrasound assessment under loaded conditions may better reflect the biomechanical function of the meniscus during activities of daily life. Clinical Relevance: Examining physiologic meniscal behavior is important to provide context for altered meniscal function in the presence of pathology, which may help inform clinical decisions regarding the management of meniscal degeneration or tears.


  • Open Access

    Effect of osteophyte removal on simulated range of motion using 3-dimensional preoperative planning software for reverse total shoulder arthroplasty

    by Joseph J. Ruzbarsky, Annalise M. Peebles, Lauren Watkins, Amelia R. Kruse, Brendan M. Lilley, Stephanie K. Eble, Patrick J. Denard, Anthony A. Romeo, Matthew T. Provencher


  • Generalizability of Deep Learning Segmentation Algorithms for Automated Assessment of Cartilage Morphology and MRI Relaxometry

    by Andrew M. Schmidt, Arjun D. Desai, Lauren E. Watkins, Hollis A. Crowder, Marianne S. Black, Valentina Mazzoli, Elka B. Rubin, Quin Lu, James W. MacKay, Robert D. Boutin, et al.

    Background: Deep learning (DL)‐based automatic segmentation models can expedite manual segmentation yet require resource‐intensive fine‐tuning before deployment on new datasets. The generalizability of DL methods to new datasets without fine‐tuning is not well characterized.Purpose: Evaluate the generalizability of DL‐based models by deploying pretrained models on independent datasets varying by MR scanner, acquisition parameters, and subject population.Study Type: Retrospective based on prospectively acquired data.Population: Overall test dataset: 59 subjects (26 females); Study 1: 5 healthy subjects (zero females), Study 2: 8 healthy subjects (eight females), Study 3: 10 subjects with osteoarthritis (eight females), Study 4: 36 subjects with various knee pathology (10 females).Field Strength/Sequence: A 3‐T, quantitative double‐echo steady state (qDESS).Assessment: Four annotators manually segmented knee cartilage. Each reader segmented one of four qDESS datasets in the test dataset. Two DL models, one trained on qDESS data and another on Osteoarthritis Initiative (OAI)‐DESS data, were assessed. Manual and automatic segmentations were compared by quantifying variations in segmentation accuracy, volume, and T2 relaxation times for superficial and deep cartilage.Statistical Tests: Dice similarity coefficient (DSC) for segmentation accuracy. Lin's concordance correlation coefficient (CCC), Wilcoxon rank‐sum tests, root‐mean‐squared error‐coefficient‐of‐variation to quantify manual vs. automatic T2 and volume variations. Bland–Altman plots for manual vs. automatic T2 agreement. A P value < 0.05 was considered statistically significant.Results: DSCs for the qDESS‐trained model, 0.79–0.93, were higher than those for the OAI‐DESS‐trained model, 0.59–0.79. T2 and volume CCCs for the qDESS‐trained model, 0.75–0.98 and 0.47–0.95, were higher than respective CCCs for the OAI‐DESS‐trained model, 0.35–0.90 and 0.13–0.84. Bland–Altman 95% limits of agreement for superficial and deep cartilage T2 were lower for the qDESS‐trained model, ±2.4 msec and ±4.0 msec, than the OAI‐DESS‐trained model, ±4.4 msec and ±5.2 msec.Data Conclusion: The qDESS‐trained model may generalize well to independent qDESS datasets regardless of MR scanner, acquisition parameters, and subject population.Evidence Level: 1Technical Efficacy: Stage 1


  • Rapid volumetric gagCEST imaging of knee articular cartilage at 3 T: evaluation of improved dynamic range and an osteoarthritic population

    by Lauren E. Watkins, Elka B. Rubin, Valentina Mazzoli, Scott D. Uhlrich, Arjun D. Desai, Marianne Black, Gabe K. Ho, Scott L. Delp, Marc E. Levenston, Gary S. Beaupré, et al.

    Chemical exchange saturation transfer of glycosaminoglycans, gagCEST, is a quantitative MR technique that has potential for assessing cartilage proteoglycan content at field strengths of 7 T and higher. However, its utility at 3 T remains unclear. The objective of this work was to implement a rapid volumetric gagCEST sequence with higher gagCEST asymmetry at 3 T to evaluate its sensitivity to osteoarthritic changes in knee articular cartilage and in comparison with T2 and T1ρ measures. We hypothesize that gagCEST asymmetry at 3 T decreases with increasing severity of osteoarthritis (OA). Forty‐two human volunteers, including 10 healthy subjects and 32 subjects with medial OA, were included in the study. Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed for all subjects, and Kellgren‐Lawrence grading was performed for OA volunteers. Healthy subjects were scanned consecutively at 3 T to assess the repeatability of the volumetric gagCEST sequence at 3 T. For healthy and OA subjects, gagCEST asymmetry and T2 and T1ρ relaxation times were calculated for the femoral articular cartilage to assess sensitivity to OA severity. Volumetric gagCEST imaging had higher gagCEST asymmetry than single‐slice acquisitions (p = 0.015). The average scan‐rescan coefficient of variation was 6.8%. There were no significant differences in average gagCEST asymmetry between younger and older healthy controls (p = 0.655) or between healthy controls and OA subjects (p = 0.310). T2 and T1ρ relaxation times were elevated in OA subjects (p < 0.001 for both) compared with healthy controls and both were moderately correlated with total KOOS scores (rho = −0.181 and rho = −0.332 respectively). The gagCEST technique developed here, with volumetric scan times under 10 min and high gagCEST asymmetry at 3 T, did not vary significantly between healthy subjects and those with mild‐moderate OA. This further supports a limited utility for gagCEST imaging at 3 T for assessment of early changes in cartilage composition in OA.


  • Acellular and cellular high-density, collagen-fibril constructs with suprafibrillar organization

    by Kevin M. Blum, Tyler Novak, Lauren Watkins, Corey P. Neu, Joseph M. Wallace, Zachary R. Bart, Sherry L. Voytik-Harbin

    Collagen is used extensively for tissue engineering due to its prevalence in connective tissues and its role in defining tissue biophysical and biological signalling properties. However, traditional collagen-based materials fashioned from atelocollagen and telocollagen have lacked collagen densities, multi-scale organization, mechanical integrity, and proteolytic resistance found within tissues in vivo. Here, highly interconnected low-density matrices of D-banded fibrils were created from collagen oligomers, which exhibit fibrillar as well as suprafibrillar assembly. Confined compression then was applied to controllably reduce the interstitial fluid while maintaining fibril integrity. More specifically, low-density (3.5 mg mL−1) oligomer matrices were densified to create collagen-fibril constructs with average concentrations of 12.25 mg mL−1 and 24.5 mg mL−1. Control and densified constructs exhibited nearly linear increases in ultimate stress, Young's modulus, and compressive modulus over the ranges of 65 to 213 kPa, 400 to 1.26 MPa, and 20 to 150 kPa, respectively. Densification also increased construct resistance to collagenase degradability. Finally, this process was amenable to creating high-density cellularized tissues; all constructs maintained high cell viability (at least 97%) immediately following compression as well as after 1 day and 7 days of culture. This method, which integrates the suprafibrillar assembly capacity of oligomers and controlled fluid reduction by confined compression, supports the rational and scalable design of a broad range of collagen-fibril materials and cell-encapsulated tissue constructs for tissue engineering applications.