CDConstantin Dreher

Constantin Dreher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Constantin Dreher has a total of 109 co-authors. Here are the top co-authors by number of shared publications:

  • Frank A. Giordano

    Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer Ufer 1-3, 68167, Mannheim, Germany

    8 shared publications
  • Judit Boda-Heggemann

    Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer Ufer 1-3, 68167, Mannheim, Germany

    8 shared publications
  • Daniel Buergy

    Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer Ufer 1-3, 68167, Mannheim, Germany

    7 shared publications
  • Alicia S. Bicu

    Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer Ufer 1-3, 68167, Mannheim, Germany

    6 shared publications
  • Jens Fleckenstein

    Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer Ufer 1-3, 68167, Mannheim, Germany

    6 shared publications
  • Stefan O. Schoenberg

    Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany

    6 shared publications

Latest Publications

  • Open Access

    HyperSightTM-CBCT based monitoring of sarcopenia during definitive radiotherapy of prostate cancer: a longitudinal feasibility study

    by Victor Siefert, Joana V. Bettenhausen, Alicia S. Bicu, Ralf Schmidt, Marvin Willam, Miriam Eckl, Florian Stieler, Michael Ehmann, Daniel Buergy, Jens Fleckenstein, et al.

    Background: Sarcopenia and treatment-related muscle loss are associated with increased toxicity and reduced resilience in cancer patients. HyperSight™ cone-beam CT (CBCT) provides improved soft-tissue contrast compared with conventional CBCT and may enable reliable longitudinal skeletal-muscle monitoring during image-guided radiotherapy (IGRT). This study evaluated the feasibility of HyperSight™ CBCT-based muscle assessment in prostate cancer patients and explored the clinical relevance of intratreatment muscle decline. Methods: Eighty-eight patients with non-metastatic prostate cancer were treated on an Ethos ® system with HyperSight™ CBCT. Patients received ultrahypofractionated (UHF) or normo-/moderately hypofractionated (NF/MHF) radiotherapy; 28% received androgen-deprivation therapy. Cross-sectional muscle area (CSA) and radiodensity (HU) were assessed on planning CT (PCT) and serial CBCTs (first, second, last fraction [FF, SF, LF]); HU values were z-standardized to subcutaneous fat (zHU). Agreement between PCT and CBCT was evaluated using concordance correlation coefficients (CCC), regression, and Bland-Altman analysis. Longitudinal changes were analyzed using mixed-effects models, and associations with acute genitourinary/gastrointestinal (GU/GI) toxicity (RTOG ≥ 2) using regression models. Results: HyperSight™ CBCT showed excellent agreement with PCT for CSA (CCC = 0.981). The NF/MHF cohort showed a significant longitudinal CSA decline (FF-LF: -153.0 mm², p = 0.021), whereas no significant within-cohort change was observed in UHF. Muscle density (zHU) decreased significantly in both cohorts (NF/MHF: p < 0.001; UHF: p = 0.0017). Weight loss and age were independently associated with zHU change, while no independent predictors of CSA decline were identified. In the NF/MHF cohort, CSA loss > 5% was associated with acute GU toxicity in univariate analysis (OR 4.90, p = 0.033; Fisher’s exact p = 0.014), but not after adjustment for age, weight loss, ECOG performance status, and ADT; no associations were found for GI toxicity or in the UHF cohort. Conclusions: HyperSight™ CBCT enables quantitative skeletal-muscle assessment during prostate radiotherapy and detects intratreatment reductions in muscle density, which may represent an early imaging marker of muscle decline. Muscle loss showed an exploratory association with acute GU toxicity in NF/MHF patients in univariate analysis, but not after adjustment. These findings support the feasibility of CBCT-based muscle monitoring and warrant further evaluation in larger cohorts. Clinical trial number: Not applicable.

  • Open Access

    Feasibility of automated AI-based contouring and stable radiomic feature assessment by HyperSight-CBCT Imaging for adaptive high-precision radiotherapy of prostate cancer

    by Ralf Schmidt, Dion Bajerski, Alicia S. Bicu, Victor Siefert, Miriam Eckl, Marvin Willam, Matthias F. Froelich, Stefan O. Schoenberg, Michael Ehmann, Daniel Buergy, et al.

    This study evaluated segmentation accuracy, efficiency, and radiomic feature stability for manual (MD), artificial intelligence-based (AI), and hybrid (MD + AI) contouring of pelvic organs on planning CT (pCT) and HyperSight cone-beam CT (hCBCT) for adaptive radiotherapy. Dice similarity and 95th percentile Hausdorff distance (HD95) quantified segmentation agreement, while radiomic feature stability was assessed using the concordance correlation coefficient (CCC). Agreement between segmentation approaches was highest for bladder and femora (median Dice 0.95–0.96; HD95 1.88–2.17 mm), intermediate for prostate and rectum (median Dice 0.92; HD95 2.22–2.62 mm), and lowest for seminal vesicles and penile bulb (median Dice 0.76–0.83; HD95 3.01–3.41 mm). AI and MD + AI reduced contouring times by about 90% and 60% compared to MD. Radiomic feature stability differed significantly between segmentation modes (all p adj ≤ 0.05). GLRLM features exhibited significantly higher stability than other features, whereas morphological features showed lower stability. Median radiomic feature stability was highest for bladder and femora, and intermediate for prostate and rectum. In conclusion, AI-based and hybrid contouring achieved high accuracy and substantial time savings, while texture- and intensity-based radiomic features showed robustness with AI segmentation. This study demonstrated feasibility of extracting distinct, reliable quantitative parameters based on AI-only contouring of pelvic structures.


  • Advanced Reliability of Radiomic Features in Ex Vivo Hypersight TM -CBCT Imaging by iCBCT-Acuros Reconstruction

    by Victor Siefert, Florian Haag, Alicia S. Bicu, Ralf Schmidt, Marvin Willam, Miriam Eckl, Florian Stieler, Michael Ehmann, Daniel Buergy, Jens Fleckenstein, et al.

    High-quality cone-beam CT (CBCT) imaging, such as HyperSight™-CBCT on the ETHOS® O-ring linear accelerator, has significantly improved adaptive radiotherapy by providing high imaging precision. Advanced reconstruction techniques like the iCBCT-Acuros reconstruction mode have the potential to enhance reliability of quantitative image evaluations, especially regarding interpretation of radiomic features. This study evaluated how the iCBCT-Acuros reconstruction mode improves reliability of radiomic features compared to standard iCBCT in HyperSight™-CBCT imaging. An ex vivo phantom analysis of 16 fruits and vegetables was conducted with HyperSight™-CBCT using iCBCT and iCBCT-Acuros reconstruction modes. Test-retest reliability was assessed at 0° and 90° rotations, along with inter- and intrareader reliability, inter-reconstruction reproducibility, and interphantom discrimination. A total of 110 radiomic features were extracted with LIFEx software, and reliability was analyzed using concordance and intraclass correlation coefficients. Boruta Random Forest analysis evaluated interphantom discrimination. Mean test-retest reliability (CCC) was higher for iCBCT-Acuros (0.936±0.137) than iCBCT (0.816±0.199, pp<0.0001). Reproducibility was moderate overall (mean 0.832±0.224), with "Morphological" features being most reproducible. Interphantom separability was increased with iCBCT-Acuros. The iCBCT-Acuros reconstruction mode of HyperSight™-CBCT significantly improves radiomic feature reliability compared to iCBCT. These advancements likely extend to other quantitative parameters, enhancing their potential as radiological biomarkers. The iCBCT-Acuros reconstruction enables a significantly more robust imaging analysis, facilitating the integration of advanced quantitative imaging techniques into high-precision radiotherapy.


  • Open Access

    Multispectral PCCT and CBCT imaging for high precision radiotherapy through translation of imaging parameters with machine learning validation

    by Constantin Dreher, Abhinay Vellala, Victor Siefert, Florian Haag, Stefan Sawall, Jens Fleckenstein, Sven Clausen, Judit Boda-Heggemann, Stefan O. Schoenberg, Frank A. Giordano, et al.

    Photon-counting CT (PCCT) is the mainstay of multi-spectral imaging, enabling quantitative tissue characterization. In radiation oncology, cone-beam CT is used daily for image-guided and online-adaptive radiotherapy. The novel HyperSight cone-beam CT imaging mode (CBCT), with enhanced image quality due in part to its enlarged detector size and optimized reconstruction modes, further facilitates quantitative image monitoring and high-precision radiotherapy. Integrating spectral PCCT information may further amplify its potential. Therefore, this study investigates whether qualitative and spectral quantitative PCCT-parameters can be translated to CBCT. An inorganic tissue-equivalent anthropomorphic phantom analysis was conducted using CBCT (iCBCT/iCBCT Acuros reconstruction, Pelvis/Pelvis Large preset) and PCCT (T3D (polychromatic reconstruction) with virtual monochromatic imaging (VMI)). Twenty regions with different CT numbers were assessed qualitatively and quantitatively. Image quality was highest for T3D PCCT. Quantitative analysis showed stronger agreement between CBCT (iCBCT Acuros) and PCCT-derived 60 and 67 keV VMI (concordance correlation coefficient (CCC) ≥ 0.595), compared to T3D (CCC ≤ 0.183), with CCC values significantly affected by CBCT presets and reconstruction method ( p ≤ 0.001). Machine learning-based hierarchical clustering confirmed alignment between CBCT and PCCT-based VMI, but not T3D. This successful translatability of specific VMI levels paves the way for the integration of multi-spectral imaging into high-precision CBCT-based radiotherapy using PCCT.

  • Open Access

    Advanced HyperSight™ imaging for patients with adaptive SBRT of prostate cancer: a longitudinal analysis of tissue demarcation

    by Ralf Schmidt, Thanh Nguyen, Alicia S. Bicu, Paula Cvachovec, Victor Siefert, Miriam Eckl, Marvin Willam, Matthias F. Froelich, Stefan O. Schoenberg, Michael Ehmann, et al.

    Background: Cone-beam computed tomography (CBCT)-based adaptive radiotherapy (ART) at the Ethos ® linear accelerator (eLinac) allows for daily anatomical and dosimetric adjustments and relies on robust image quality. This study evaluated the longitudinal image quality of the novel HyperSight TM -CBCT (hCBCT) compared to planning CT (pCT), using phantoms and data of prostate cancer patients undergoing adaptive stereotactic body radiotherapy (SBRT). Building on this, the longitudinal contour sharpness of the organs in fractional hCBCT and their usability for ART workflow across fractions was evaluated. Methods: Between December 2023 and May 2024, 26 prostate cancer patients receiving ART at the eLinac with hCBCT technology were enrolled. Phantom studies assessed pCT and hCBCT image quality. Patient based analyses of all 156 imaging scans (pCT and each of the fractional hCBCT) analyzed, longitudinally examined firstly image quality, secondly contour sharpness of prostate, seminal vesicles, and rectal wall, and thirdly confidence to delineate the structures for the ART workflow. Time required for the ART based parameters were recorded. Quantitative metrics included CT number changes in the fat adjacent to the prostate and seminal vesicles. Friedman’s test with Bonferroni correction, Spearman and Intraclass Correlation Coefficient (ICC) were used for statistics. Results: hCBCT scans showed robust image quality parameters in the phantom and patient based analysis across fractions. Inter-observer agreement was moderate, with lower rating score for resident compared to the experienced radiation oncologist ( p < 0.001). Patient based analysis showed no significant differences of the contour sharpness of the prostate and seminal vesicles between pCT and initial hCBCT scan, but contour sharpness ratings declined across treatment fractions. Confidence for the delineation of prostate and seminal vesicles during ART was significantly decreased at later fractions (each p adj adj ≤0.05). The CT attenuation of the fat tissue adjacent to the prostate and seminal vesicles significantly increased across the fractions (p adj <0.05). Conclusions: High-quality imaging for adaptive SBRT in prostate cancer is provided by hCBCT, which offers equivalent tissue visualization compared to pCT. Fraction-dependent decreases in contour sharpness can be detected using longitudinal hCBCT imaging. These decreases are likely related to treatment-induced tissue changes and may impact ART workflow. The rating of the observed effects may potentially be influenced by the observer’s experience.


  • Open Access

    Analysis of metabolic liver function and MR-morphological cholestatic parameters after SBRT of liver metastases

    by Constantin Dreher, Paulina Wojtal, Maren Johann, Alicia S. Bicu, Lena Kaestner, Christel Weiss, Svetlana Hetjens, Anoshirwan A. Tavakoli, Dominik Nörenberg, Oliver Blanck, et al.

    Background: This study examined the longitudinal changes in metabolic liver function and MR-morphological dilatation of intrahepatic bile ducts in patients with stereotactic body radiation therapy (SBRT) for liver metastases. Methods: This retrospective study included 64 patients with SBRT of 84 liver metastases between February 2005 and January 2019. To evaluate hepatobiliary toxicity, the laboratory parameters albumin, alanine-transaminase (ALAT), aspartate-transaminase (ASAT), bilirubin and gamma-glutamyltransferase (GGT) and the qualitative dilatation of MR-morphological peritumoural, intrahepatic bile ducts were analyzed from pre- up to 12 months post-SBRT. Results: The liver metastases were irradiated with a median D50 to the GTV of BED α/β=10 Gy = 134 Gy (range 51–219 Gy) resulting in a median mean dose D mean -L-EQD2 α/β=3 Gy = 11.8 Gy (range 0.4–65.6 Gy) to the total liver. The central hepatobiliary tract (cHBT) was exposed to a median D mean -cHBT-BED α/β=10 Gy = 8.3 Gy (range 0.1–81.6 Gy). Significant decreases in albumin and increases in GGT and bilirubin were observed up to 12 months post-SBRT. D mean -L-EQD2 α/β=3 Gy , D mean -cHBT-BED α/β=10 Gy and VBED α/β=10Gy 66Gy-cHBT and VBED α/β=10Gy 72Gy-cHBT were significant cofactors influencing the course of GGT, ASAT and bilirubin, but not for albumin and ALAT. MR-morphological, short- and long-term dilatation of peritumoural bile ducts were associated with significant higher VBED α/β=10Gy 66Gy-cHBT and VBED α/β=10Gy 72Gy-cHBT values and were significantly more frequent for SBRT of target volumes with < 3 cm distance to the cHBT. Conclusion: SBRT of liver metastases was associated with minor alterations in metabolic liver function. High dose exposure and proximity of the liver metastases to the cHBT may lead to locoregional bile duct dilatation after SBRT. Further evaluation of metabolic and MR-morphological changes in liver function is recommended in personalised oncological treatment approaches for liver-directed therapies.

  • Open Access

    Longitudinal stability of HyperSightTM-CBCT based radiomic features in patients with CT guided adaptive SBRT for prostate cancer

    by Paula Cvachovec, Alicia S. Bicu, Ralf Schmidt, Victor Siefert, Miriam Eckl, Marvin Willam, Sven Clausen, Matthias F. Froelich, Stefan O. Schoenberg, Michael Ehmann, et al.

    CT-guided adaptive radiotherapy (aRT) based on HyperSightTM-CBCT provides high-quality imaging, allowing quantitative radiomic feature analysis as a monitoring tool. This study comprehensively evaluates the stability of radiomic features, as potential imaging biomarkers, in pelvic structures of prostate cancer patients treated with adaptive stereotactic body radiation therapy (SBRT). Between December 2023 and July 2024, 32 patients with localized prostate cancer underwent adaptive SBRT at the Ethos® linear accelerator (Varian, Siemens Healthineers) with HyperSight-CBCT imaging. Longitudinal stability was assessed by intraclass correlation coefficient (ICC) over five fractions of aRT for target structures and non-hollow organs at risk. In pooled organs at risk, 93.0% of features showed very high stability (ICC > 0.9) compared to 67.4% in pooled target structures, indicating significantly lower stability for target structures (p = 0.00009129). Second-order features demonstrated greater stability than conventional and shape-based features (p = 0.0433, p = 0.0252). Fraction number significantly affected longitudinal prostate feature variability (p = 0.0135). This study comprehensively analyzed HyperSight-CBCT imaging to evaluate longitudinal stability of radiomic features during adaptive SBRT for prostate cancer. The trends observed will provide a framework for future CT-guided aRT studies, facilitating quantitative imaging analysis of radiological biomarkers for clinical translation and improving personalized treatment.


  • Long-term characterization of MRI-morphologic alterations after active motion-compensated liver SBRT: a multi-institutional pooled analysis

    by Constantin Dreher, Gustavo R. Sarria, Georgia Miebach, Christel Weiss, Daniel Buergy, Paulina Wojtal, Anoshirwan A. Tavakoli, David Krug, Hans Oppitz, Frank A. Giordano, et al.

    Stereotactic body radiotherapy (SBRT) is an effective therapeutic approach in patients with liver metastases. However, long-term changes in hepatic normal tissue have to be taken into account in mu...


  • Open Access

    MR-guided adaptive versus ITV-based stereotactic body radiotherapy for hepatic metastases (MAESTRO): a randomized controlled phase II trial

    by P. Hoegen, K. S. Zhang, E. Tonndorf-Martini, F. Weykamp, S. Regnery, P. Naumann, K. Lang, J. Ristau, S. A. Körber, C. Dreher, et al.

    Background: Stereotactic body radiotherapy (SBRT) is an established local treatment method for patients with hepatic oligometastasis or oligoprogression. Liver metastases often occur in close proximity to radiosensitive organs at risk (OARs). This limits the possibility to apply sufficiently high doses needed for optimal local control. Online MR-guided radiotherapy (oMRgRT) is expected to hold potential to improve hepatic SBRT by offering superior soft-tissue contrast for enhanced target identification as well as the benefit of gating and daily real-time adaptive treatment. The MAESTRO trial therefore aims to assess the potential advantages of adaptive, gated MR-guided SBRT compared to conventional SBRT at a standard linac using an ITV (internal target volume) approach. Methods: This trial is conducted as a prospective, randomized, three-armed phase II study in 82 patients with hepatic metastases (solid malignant tumor, 1–3 hepatic metastases confirmed by magnetic resonance imaging (MRI), maximum diameter of each metastasis ≤ 5 cm (in case of 3 metastases: sum of diameters ≤ 12 cm), age ≥ 18 years, Karnofsky Performance Score ≥ 60%). If a biologically effective dose (BED) ≥ 100 Gy (α/β = 10 Gy) is feasible based on ITV-based planning, patients will be randomized to either MRgRT or ITV-based SBRT. If a lesion cannot be treated with a BED ≥ 100 Gy, the patient will be treated with MRgRT at the highest possible dose. Primary endpoint is the non-inferiority of MRgRT at the MRIdian Linac® system compared to ITV-based SBRT regarding hepatobiliary and gastrointestinal toxicity CTCAE III or higher. Secondary outcomes investigated are local, locoregional (intrahepatic) and distant tumor control, progression-free survival, overall survival, possible increase of BED using MRgRT if the BED is limited with ITV-based SBRT, treatment-related toxicity, quality of life, dosimetric parameters of radiotherapy plans as well as morphological and functional changes in MRI. Potential prognostic biomarkers will also be evaluated. Discussion: MRgRT is known to be both highly cost- and labor-intensive. The MAESTRO trial aims to provide randomized, higher-level evidence for the dosimetric and possible consecutive clinical benefit of MR-guided, on-table adaptive and gated SBRT for dose escalation in critically located hepatic metastases adjacent to radiosensitive OARs. Trial registration: The study has been prospectively registered on August 30th, 2021: Clinicaltrials.gov, “Magnetic Resonance-guided Adaptive Stereotactic Body Radiotherapy for Hepatic Metastases (MAESTRO)”, NCT05027711.


  • Pancreatic imaging using diffusivity mapping – Influence of sequence technique on qualitative and quantitative analysis

    by Anoshirwan Andrej Tavakoli, Constantin Dreher, Anna Mlynarska, Tristan Anselm Kuder, Regula Gnirs, Heinz-Peter Schlemmer, Sebastian Bickelhaupt