CECalvin. D. Eiber

Calvin. D. Eiber

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Calvin. D. Eiber has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Selective recording of physiologically evoked neural activity in a mixed autonomic nerve using a minimally invasive array

    by Sophie C. Payne, Peregrine B. Osborne, Alex Thompson, Calvin D. Eiber, Janet R. Keast, James B. Fallon

    Real-time closed-loop control of neuromodulation devices requires long-term monitoring of neural activity in the peripheral nervous system. Although many signal extraction methods exist, few are both clinically viable and designed for extracting small signals from fragile peripheral visceral nerves. Here, we report that our minimally invasive recording and analysis technology extracts low to negative signal to noise ratio (SNR) neural activity from a visceral nerve with a high degree of specificity for fiber type and class. Complex activity was recorded from the rat pelvic nerve that was physiologically evoked during controlled bladder filling and voiding, in an extensively characterized in vivo model that provided an excellent test bed to validate our technology. Urethane-anesthetized male rats (n = 12) were implanted with a four-electrode planar array and the bladder instrumented for continuous-flow cystometry, which measures urodynamic function by recording bladder pressure changes during constant infusion of saline. We demonstrated that differential bipolar recordings and cross-correlation analyses extracts afferent and efferent activity, and discriminated between subpopulations of fibers based on conduction velocity. Integrated Aδ afferent fiber activity correlated with bladder pressure during voiding (r2: 0.66 ± 0.06) and was not affected by activating nociceptive afferents with intravesical capsaicin (r2: 0.59 ± 0.14, P = 0.54, and n = 3). Collectively, these results demonstrate our minimally invasive recording and analysis technology is selective in extracting mixed neural activity with low/negative SNR. Furthermore, integrated afferent activity reliably correlates with bladder pressure and is a promising first step in developing closed-loop technology for bladder control.


  • Open Access

    Fractal Microelectrodes for More Energy‐Efficient Cervical Vagus Nerve Stimulation

    by Jongcheon Lim, Calvin D. Eiber, Anina Sun, Amanda Maples, Terry L. Powley, Matthew P. Ward, Hyowon Lee

    Vagus nerve stimulation (VNS) has the potential to treat various peripheral dysfunctions, but the traditional cuff electrodes for VNS are susceptible to off‐target effects. Microelectrodes may enable highly selective VNS that can mitigate off‐target effects, but they suffer from the increased impedance. Recent studies on microelectrodes with non‐Euclidean geometries have reported higher energy efficiency in neural stimulation applications. These previous studies use electrodes with mm/cm‐scale dimensions, mostly targeted for myelinated fibers. This study evaluates fractal microelectrodes for VNS in a rodent model (N = 3). A thin‐film device with fractal and circle microelectrodes is fabricated to compare their neural stimulation performance on the same radial coordinate of the nerve. The results show that fractal microelectrodes can activate C‐fibers with up to 52% less energy (p = 0.012) compared to circle microelectrodes. To the best of the knowledge, this work is the first to demonstrate a geometric advantage of fractal microelectrodes for VNS in vivo.


  • Open Access

    Computational modelling of nerve stimulation and recording with peripheral visceral neural interfaces

    by Calvin D Eiber, Sophie C Payne, Natalia P Biscola, Leif A Havton, Janet R Keast, Peregrine B Osborne, James B Fallon

    Objective.Neuromodulation of visceral nerves is being intensively studied for treating a wide range of conditions, but effective translation requires increasing the efficacy and predictability of neural interface performance. Here we use computational models of rat visceral nerve to predict how neuroanatomical variability could affect both electrical stimulation and recording with an experimental planar neural interface.Approach.We developed a hybrid computational pipeline,VisceralNerveEnsembleRecording andStimulation (ViNERS), to couple finite-element modelling of extracellular electrical fields with biophysical simulations of individual axons. Anatomical properties of fascicles and axons in rat pelvic and vagus nerves were measured or obtained from public datasets. To validate ViNERS, we simulated pelvic nerve stimulation and recording with an experimental four-electrode planar array.Main results.Axon diameters measured from pelvic nerve were used to model a population of myelinated and unmyelinated axons and simulate recordings of electrically evoked single-unit field potentials (SUFPs). Across visceral nerve fascicles of increasing size, our simulations predicted an increase in stimulation threshold and a decrease in SUFP amplitude. Simulated threshold changes were dominated by changes in perineurium thickness, which correlates with fascicle diameter. We also demonstrated that ViNERS could simulate recordings of electrically-evoked compound action potentials (ECAPs) that were qualitatively similar to pelvic nerve recording made with the array used for simulation.Significance.We introduce ViNERS as a new open-source computational tool for modelling large-scale stimulation and recording from visceral nerves. ViNERS predicts how neuroanatomical variation in rat pelvic nerve affects stimulation and recording with an experimental planar electrode array. We show ViNERS can simulate ECAPS that capture features of our recordings, but our results suggest the underlying NEURON models need to be further refined and specifically adapted to accurately simulate visceral nerve axons.


  • Open Access

    Rapid Analysis of Visual Receptive Fields by Iterative Tomography

    by Calvin. D. Eiber, Jin Y. Huang, Spencer C. Chen, Natalie Zeater, Alexander N. J. Pietersen, Dario. A. Protti, Paul R. Martin

    Many receptive fields in the early visual system show standard (center-surround) structure and can be analyzed using simple drifting patterns and a difference-of-Gaussians (DoG) model, which treats the receptive field as a linear filter of the visual image. But many other receptive fields show nonlinear properties such as selectivity for direction of movement. Such receptive fields are typically studied using discrete stimuli (moving or flashed bars and edges) and are modelled according to the features of the visual image to which they are most sensitive. Here, we harness recent advances in tomographic image analysis to characterize rapidly and simultaneously both the linear and nonlinear components of visual receptive fields. Spiking and intracellular voltage potential responses to briefly flashed bars are analyzed using non-negative matrix factorization (NNMF) and iterative reconstruction tomography (IRT). The method yields high-resolution receptive field maps of individual neurons and neuron ensembles in primate (marmoset, both sexes) lateral geniculate and rodent (mouse, male) retina. We show that the first two IRT components correspond to DoG-equivalent center and surround of standard [magnocellular (M) and parvocellular (P)] receptive fields in primate geniculate. The first two IRT components also reveal the spatiotemporal receptive field structure of nonstandard (on/off-rectifying) receptive fields. In rodent retina we combine NNMF-IRT with patch-clamp recording and dye injection to directly map spatial receptive fields to the underlying anatomy of retinal output neurons. We conclude that NNMF-IRT provides a rapid and flexible framework for study of receptive fields in the early visual system.


  • Open Access

    Preliminary Minimum Reporting Requirements for Reporting In-Vivo Neural Interface Research: I. Implantable Neural Interfaces

    by Calvin D. Eiber, Jean Delbeke, Jorge Cardoso, Martijn de Neeling, Sam E. John, Chang Won Lee, Jerry Skefos, Argus Sun, Dimiter Prodanov, Zach McKinney

    The pace of research and development in neuroscience, neurotechnology, and neurorehabilitation is rapidly accelerating, with the number of publications doubling every 4.2 years. Maintaining this progress requires technological standards and scientific reporting guidelines to provide frameworks for communication and interoperability. The present lack of such standards for neurotechnologies limits the transparency, reproducibility, and meta-analysis of this growing body of research, posing an ongoing barrier to research, clinical, and commercial objectives. Continued neurotechnological innovation requires the development of some minimal standards to promote integration between this broad spectrum of technologies and therapies. To preserve design freedom and accelerate the translation of research into safe and effective technologies with maximal user benefit, such standards must be collaboratively co-developed by a full spectrum of neuroscience and neurotechnology stakeholders. This paper summarizes the preliminary recommendations of IEEE Working Group P2794, developing a Reporting Standard for in-vivo Neural Interface Research (RSNIR). Impact Statement: This work provides a preliminary set of reporting guidelines for implantable neural interface research, developed by IEEE WG P2794 in open collaboration between a range of stakeholders to accelerate the research, development, and integration of innovative neurotechnologies.

  • Open Access

    Receptive Field Properties of Koniocellular On/Off Neurons in the Lateral Geniculate Nucleus of Marmoset Monkeys

    by Calvin D. Eiber, Abrar S. Rahman, Alexander N.J. Pietersen, Natalie Zeater, Bogdan Dreher, Samuel G. Solomon, Paul R. Martin

    The koniocellular (K) layers of the primate dorsal lateral geniculate nucleus house a variety of visual receptive field types, not all of which have been fully characterized. Here we made single-cell recordings targeted to the K layers of diurnal New World monkeys (marmosets). A subset of recorded cells was excited by both increments and decrements of light intensity (on/off-cells). Histological reconstruction of the location of these cells confirmed that they are segregated to K layers; we therefore refer to these cells as K-on/off cells. The K-on/off cells show high contrast sensitivity, strong bandpass spatial frequency tuning, and their response magnitude is strongly reduced by stimuli larger than the excitatory receptive field (silent suppressive surrounds). Stationary counterphase gratings evoke unmodulated spike rate increases or frequency-doubled responses in K-on/off cells; such responses are largely independent of grating spatial phase. The K-on/off cells are not orientation or direction selective. Some (but not all) properties of K-on/off cells are consistent with those of local-edge-detector/impressed-by-contrast cells reported in studies of cat retina and geniculate, and broad-thorny ganglion cells recorded in macaque monkey retina. The receptive field properties of K-on/off cells and their preferential location in the ventral K layers (K1 and K2) make them good candidates for the direct projection from geniculate to extrastriate cortical area MT/V5. If so, they could contribute to visual information processing in the dorsal (“where” or “action”) visual stream.SIGNIFICANCE STATEMENTWe characterize cells in an evolutionary ancient part of the visual pathway in primates. The cells are located in the lateral geniculate nucleus (the main visual afferent relay nucleus), in regions called koniocellular layers that are known to project to extrastriate visual areas as well as primary visual cortex. The cells show high contrast sensitivity and rapid, transient responses to light onset and offset. Their properties suggest they could contribute to visual processing in the dorsal (“where” or “action”) visual stream.


  • Multipolar Field Shaping in a Suprachoroidal Visual Prosthesis

    by Calvin D. Eiber, Socrates Dokos, Nigel H. Lovell, Gregg J. Suaning

    Visual prostheses are now an available mobility aid for patients blinded by degenerative retinal diseases. However, the spatial resolution of existing devices is still insufficient to deliver normal levels of mobility vision without stimulation strategies, which enable existing devices to deliver several different percepts per stimulation site. A stimulation strategy, in which field shaping is achieved by incorporating multipolar (bipolar and tripolar) stimulation could convey additional information to a user of a visual prosthesis, as compared with monopolar stimulation, is investigated. Electrical stimulus response thresholds were simulated using morphologically and physiologically accurate cable models of human retinal ganglion cell (RGC) axons. From the population response patterns which could be evoked in simulation, multipolar field-shaping stimulation from one location could convey as much information as monopolar array stimulation. This result is confirmed in vitro by applying a Bayesian classification analysis to multielectrode array recordings of RGC population responses to extracellular stimulation. In vitro recorded population responses to individual stimuli in vitro could be used to train a Baysian classifier, which could correctly identify individual stimuli as predicted by the simulated population responses. In both simulation and in vitro experiments, monopolar thresholds were not significantly different to multipolar thresholds.


  • Feasibility study of imaging fast neural activity in retinal tissue using Electrical Impedance Tomography

    by Danyi Zhu, Xiunan Fang, Calvin Eiber, James Avery, David Holder, Alistair McEwan

    Electrical Impedance Tomography has been recently applied to image fast neural activity in the somatosensory cerebral cortex. This non-invasive imaging modality has the unique advantage of high spatial-temporal resolution in millimeters over milliseconds. This work was designed to test an existing 32-channel EIT system, a modified UCL ScouseTom, and to discuss the feasibility of imaging neural activity in retinal tissue through computer simulation. The finite element method was used to model a retinal slice with a realistic conductivity-depth profile of the macaque eye. The conductivity perturbation was simulated in five different layers of the model. 5μV RMS white noise was added to boundary voltages. Simulation results showed that it is feasible to apply EIT in retinal tissue but the injection current is near threshold of unwanted phosphenes induction. Therefore the suggested future work are validating threshold current through animal experiments, developing electrodes with low contact impedance and mitigating noise through averaging.