Michele Biasotti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michele Biasotti has a total of 556 co-authors. Here are the top co-authors by number of shared publications:
F. Gatti
INFN, Sez Genova, Via Dodecaneso 33, I-16146 Genoa, Italy
43 shared publications- Matteo De Gerone
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Genova
35 shared publications - Andrea Giachero
Dipartimento di Fisica, Università di Milano-Bicocca, I-20126 Milano, Italy
21 shared publications - Andrei Puiu
INFN Laboratori Nazionali del Gran Sasso
19 shared publications D. Corsini
University of Genova
18 shared publications- Angiola Orlando
Cardiff Univ. (United Kingdom)
15 shared publications
Latest Publications
- Open Access
The Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment
The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay : BR() at confidence level. The MEG detector has been upgraded in order to reach a sensitivity of . The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ( muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.Open AccessThe Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment
The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay : BR() at confidence level. The MEG detector has been upgraded in order to reach a sensitivity of . The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ( muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs. - Open Access
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Direct Search for Low Energy Nuclear Isomeric Transition of Th-229m With TES Detector
Precise knowledge of the energy and lifetime of 229m Th isomeric state has notable importance as a basis for a nuclear clock. Such a clock would be capable to extend precision on the oscillator frequency by up to four orders of magnitude compared to the presently best atomic clocks. However, the technique proposed for the clock requires that the isomeric state energy is accessible with existing laser systems. Previous measurement placed this state at ∼8 eV (150 nm), in the Vacuum Ultra Violet (VUV) range of the electromagnetic spectrum. A precise direct measurement of the energy of this state is necessary to determine whether the nuclear clock can be made using existing laser technology. We are developing a cryogenic microcalorimeter to measure the energy and lifetime of the 229m Th isomeric state directly. The experiment will use a 233 U source whose alpha-decay will populate the 229m Th isomeric state with 2% probability. The subsequent decay of 229m Th will be measured by a Transition Edge Sensor (TES) with 5 microseconds. The single-photon TES has sufficient resolving power combined with high efficiency in the whole energy band for this experiment. Here we present a prototype of TES based on a 200 nm thick iridium-gold (Ir/Au) film which was tested with a pulsed laser source and demonstrated ∼0.8 eV energy resolution and 5.8 ± 2.1 μs signal recovery time.
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Open AccessDirect Search for Low Energy Nuclear Isomeric Transition of Th-229m With TES Detector
Precise knowledge of the energy and lifetime of 229m Th isomeric state has notable importance as a basis for a nuclear clock. Such a clock would be capable to extend precision on the oscillator frequency by up to four orders of magnitude compared to the presently best atomic clocks. However, the technique proposed for the clock requires that the isomeric state energy is accessible with existing laser systems. Previous measurement placed this state at ∼8 eV (150 nm), in the Vacuum Ultra Violet (VUV) range of the electromagnetic spectrum. A precise direct measurement of the energy of this state is necessary to determine whether the nuclear clock can be made using existing laser technology. We are developing a cryogenic microcalorimeter to measure the energy and lifetime of the 229m Th isomeric state directly. The experiment will use a 233 U source whose alpha-decay will populate the 229m Th isomeric state with 2% probability. The subsequent decay of 229m Th will be measured by a Transition Edge Sensor (TES) with 5 microseconds. The single-photon TES has sufficient resolving power combined with high efficiency in the whole energy band for this experiment. Here we present a prototype of TES based on a 200 nm thick iridium-gold (Ir/Au) film which was tested with a pulsed laser source and demonstrated ∼0.8 eV energy resolution and 5.8 ± 2.1 μs signal recovery time.
- 1 April 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 958
Full system of positron timing counter in MEG II having time resolution below 40 ps with fast plastic scintillator readout by SiPMs
- 1 April 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 958
Full system of positron timing counter in MEG II having time resolution below 40 ps with fast plastic scintillator readout by SiPMs
- 27 January 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 225-230
The Phonon-Mediated TES Cosmic Ray Detector for Focal Plane of ATHENA X-Ray Telescope
- 27 January 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 225-230
The Phonon-Mediated TES Cosmic Ray Detector for Focal Plane of ATHENA X-Ray Telescope
- 20 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 65-72
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
- 20 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 65-72
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
- 12 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 138-142
TES Microcalorimeters for PTOLEMY
- 12 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 138-142
TES Microcalorimeters for PTOLEMY
- 9 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (3-4) , 716-722
Transition-Edge Sensors for HOLMES
- 9 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (3-4) , 716-722
Transition-Edge Sensors for HOLMES