Evangelos Vrettos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Evangelos Vrettos has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Goran Andersson
Zurich Switzerland CH-8092
5 shared publications - Jason MacDonald
Lawrence Berkeley National Laboratory
5 shared publications Duncan S. Callaway
Energy and Resources Group, University of California at Berkeley, Berkeley, USA
3 shared publications- Duncan S. Callaway
University of California, Berkeley
3 shared publications - Charalampos Ziras
Department of Electrical Engineering, Technical University of Denmark
2 shared publications Emre C. Kara
SLAC National Accelerator Laboratory, Menlo Park, CA, USA
2 shared publications
Latest Publications
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 19 (2) , 56-68
A Vision to Enhance Transmission Security: The Case of Switzerland's Power System
It is hard to imagine life without electricity. Electrical energy is constantly consumed to allow humanity to carry out diverse activities ranging from charging mobile phones to controlling the flow of vehicles and pedestrians with traffic lights. Due to its widespread usage and significance, some people take the availability of electric power for granted and expect that the lights will always turn on when they turn on the switch. Nevertheless, when illuminating our rooms, we need to appreciate that an extensive power system infrastructure is in place to securely generate, transport, and distribute electrical energy to our homes.
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 19 (2) , 56-68
A Vision to Enhance Transmission Security: The Case of Switzerland's Power System
It is hard to imagine life without electricity. Electrical energy is constantly consumed to allow humanity to carry out diverse activities ranging from charging mobile phones to controlling the flow of vehicles and pedestrians with traffic lights. Due to its widespread usage and significance, some people take the availability of electric power for granted and expect that the lights will always turn on when they turn on the switch. Nevertheless, when illuminating our rooms, we need to appreciate that an extensive power system infrastructure is in place to securely generate, transport, and distribute electrical energy to our homes.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 108 (9) , 1623-1639
A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings
Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 108 (9) , 1623-1639
A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings
Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.
- 3 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 3209-3220
MPC-Based Fast Frequency Control of Voltage Source Converters in Low-Inertia Power Systems
A rapid deployment of renewable generation has led to significant reduction in the rotational system inertia and damping, thus making frequency control in power systems more challenging. This paper proposes a novel control scheme based on Model Predictive Control (MPC) for converter-interfaced generators operating in a grid-forming mode, with the goal of exploiting their fast response capabilities to provide fast frequency control service to the system. The controller manipulates converter power injections to limit the frequency nadir and rate-of-change-of-frequency after a disturbance. Both centralized and decentralized MPC approaches are considered and compared in terms of performance and practical implementation. Special attention is given to the decentralized controller by generating an explicit MPC solution to enhance computational efficiency and reduce hardware requirements. Simulation results obtained from a detailed dynamic model of the IEEE 39-bus system demonstrate the effectiveness of the proposed control schemes.
- 3 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 3209-3220
MPC-Based Fast Frequency Control of Voltage Source Converters in Low-Inertia Power Systems
A rapid deployment of renewable generation has led to significant reduction in the rotational system inertia and damping, thus making frequency control in power systems more challenging. This paper proposes a novel control scheme based on Model Predictive Control (MPC) for converter-interfaced generators operating in a grid-forming mode, with the goal of exploiting their fast response capabilities to provide fast frequency control service to the system. The controller manipulates converter power injections to limit the frequency nadir and rate-of-change-of-frequency after a disturbance. Both centralized and decentralized MPC approaches are considered and compared in terms of performance and practical implementation. Special attention is given to the decentralized controller by generating an explicit MPC solution to enhance computational efficiency and reduce hardware requirements. Simulation results obtained from a detailed dynamic model of the IEEE 39-bus system demonstrate the effectiveness of the proposed control schemes.
- Open Access
- 4 January 2017
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 5 (1) , 43-54
Controllability and stability of primary frequency control from thermostatic loads with delays
- 4 January 2017
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 5 (1) , 43-54
Open AccessControllability and stability of primary frequency control from thermostatic loads with delays
- Open Access
- 15 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (4) , 3213-3223
Experimental Demonstration of Frequency Regulation by Commercial Buildings—Part I: Modeling and Hierarchical Control Design
This paper is the first part of a two-part series in which we present results from one of the first worldwide experimental demonstrations of frequency regulation in a commercial building test facility. We demonstrate that commercial buildings can track a frequency regulation signal with high accuracy and minimal occupant discomfort in a realistic environment. In addition, we show that buildings can determine the reserve capacity and baseline power a priori, and identify the optimal tradeoff between frequency regulation and energy efficiency. In part I, we introduce the test facility and develop relevant building models. Furthermore, we design a hierarchical controller for the heating, ventilation, and air conditioning system that consists of three levels: 1) a reserve scheduler; 2) a building climate controller; and 3) a fan speed controller for frequency regulation. We formulate the reserve scheduler as a robust optimization problem and introduce several approximations to reduce its complexity. The building climate controller is comprised of a robust model predictive controller and a Kalman filter. The frequency regulation controller consists of a feedback and a feedforward loop, provides fast responses, and is stable. Part I presents building model identification and controller tuning results. Specifically, we find out that with an appropriate formulation of the model identification problem, a two-state model is accurate enough for use in a reserve scheduler that runs day-ahead. In part II, we report results from the operation of the hierarchical controller under frequency regulation.
- 15 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (4) , 3213-3223
Open AccessExperimental Demonstration of Frequency Regulation by Commercial Buildings—Part I: Modeling and Hierarchical Control Design
This paper is the first part of a two-part series in which we present results from one of the first worldwide experimental demonstrations of frequency regulation in a commercial building test facility. We demonstrate that commercial buildings can track a frequency regulation signal with high accuracy and minimal occupant discomfort in a realistic environment. In addition, we show that buildings can determine the reserve capacity and baseline power a priori, and identify the optimal tradeoff between frequency regulation and energy efficiency. In part I, we introduce the test facility and develop relevant building models. Furthermore, we design a hierarchical controller for the heating, ventilation, and air conditioning system that consists of three levels: 1) a reserve scheduler; 2) a building climate controller; and 3) a fan speed controller for frequency regulation. We formulate the reserve scheduler as a robust optimization problem and introduce several approximations to reduce its complexity. The building climate controller is comprised of a robust model predictive controller and a Kalman filter. The frequency regulation controller consists of a feedback and a feedforward loop, provides fast responses, and is stable. Part I presents building model identification and controller tuning results. Specifically, we find out that with an appropriate formulation of the model identification problem, a two-state model is accurate enough for use in a reserve scheduler that runs day-ahead. In part II, we report results from the operation of the hierarchical controller under frequency regulation.
- Open Access
- 15 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (4) , 3224-3234
Experimental Demonstration of Frequency Regulation by Commercial Buildings—Part II: Results and Performance Evaluation
This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. In part I, we developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control, and frequency regulation. In part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland power market very accurately. In addition, we discuss potential effects of frequency regulation on building operation (e.g., increase in energy consumption, oscillations in supply air temperature, and effect on chiller cycling), and provide suggestions for real-world implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.
- 15 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (4) , 3224-3234
Open AccessExperimental Demonstration of Frequency Regulation by Commercial Buildings—Part II: Results and Performance Evaluation
This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. In part I, we developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control, and frequency regulation. In part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland power market very accurately. In addition, we discuss potential effects of frequency regulation on building operation (e.g., increase in energy consumption, oscillations in supply air temperature, and effect on chiller cycling), and provide suggestions for real-world implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.
- Open Access
Fast and Reliable Primary Frequency Reserves From Refrigerators with Decentralized Stochastic Control
Due to increasing shares of renewable energy sources, more frequency reserves are required to maintain power system stability. In this paper, we present a decentralized control scheme that allows a large aggregation of refrigerators to provide Primary Frequency Control (PFC) reserves to the grid based on local frequency measurements and without communication. The control is based on stochastic switching of refrigerators depending on the frequency deviation. We develop methods to account for typical lockout constraints of compressors and increased power consumption during the startup phase. In addition, we propose a procedure to dynamically reset the thermostat temperature limits in order to provide reliable PFC reserves, as well as a corrective temperature feedback loop to build robustness to biased frequency deviations. Furthermore, we introduce an additional randomization layer in the controller to account for thermostat resolution limitations, and finally, we modify the control design to account for refrigerator door openings. Extensive simulations with actual frequency signal data and with different aggregation sizes, load characteristics, and control parameters, demonstrate that the proposed controller outperforms a relevant state-of-the-art controller.
Open AccessFast and Reliable Primary Frequency Reserves From Refrigerators with Decentralized Stochastic Control
Due to increasing shares of renewable energy sources, more frequency reserves are required to maintain power system stability. In this paper, we present a decentralized control scheme that allows a large aggregation of refrigerators to provide Primary Frequency Control (PFC) reserves to the grid based on local frequency measurements and without communication. The control is based on stochastic switching of refrigerators depending on the frequency deviation. We develop methods to account for typical lockout constraints of compressors and increased power consumption during the startup phase. In addition, we propose a procedure to dynamically reset the thermostat temperature limits in order to provide reliable PFC reserves, as well as a corrective temperature feedback loop to build robustness to biased frequency deviations. Furthermore, we introduce an additional randomization layer in the controller to account for thermostat resolution limitations, and finally, we modify the control design to account for refrigerator door openings. Extensive simulations with actual frequency signal data and with different aggregation sizes, load characteristics, and control parameters, demonstrate that the proposed controller outperforms a relevant state-of-the-art controller.
- Open Access
Experimental Demonstration of Frequency Regulation by Commercial Buildings - Part I: Modeling and Hierarchical Control Design
This paper is the first part of a two-part series in which we present results from an experimental demonstration of frequency regulation in a commercial building test facility. In Part I, we introduce the test facility and develop relevant building models. Furthermore, we design a hierarchical controller that consists of three levels: a reserve scheduler, a building climate controller, and a fan speed controller for frequency regulation. We formulate the reserve scheduler as a robust optimization problem and introduce several approximations to reduce its complexity. The building climate controller is comprised of a robust model predictive controller and a Kalman filter. The frequency regulation controller consists of a feedback and a feedforward loop, provides fast responses, and is stable. Part I presents building model identification and controller tuning results, whereas Part II reports results from the operation of the hierarchical controller under frequency regulation.
Open AccessExperimental Demonstration of Frequency Regulation by Commercial Buildings - Part I: Modeling and Hierarchical Control Design
This paper is the first part of a two-part series in which we present results from an experimental demonstration of frequency regulation in a commercial building test facility. In Part I, we introduce the test facility and develop relevant building models. Furthermore, we design a hierarchical controller that consists of three levels: a reserve scheduler, a building climate controller, and a fan speed controller for frequency regulation. We formulate the reserve scheduler as a robust optimization problem and introduce several approximations to reduce its complexity. The building climate controller is comprised of a robust model predictive controller and a Kalman filter. The frequency regulation controller consists of a feedback and a feedforward loop, provides fast responses, and is stable. Part I presents building model identification and controller tuning results, whereas Part II reports results from the operation of the hierarchical controller under frequency regulation.
- Open Access
Experimental Demonstration of Frequency Regulation by Commercial Buildings - Part II: Results and Performance Evaluation
This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. In Part I, we developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation. In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we report the observed effects of frequency regulation on building control and provide suggestions for realworld implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.
Open AccessExperimental Demonstration of Frequency Regulation by Commercial Buildings - Part II: Results and Performance Evaluation
This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. In Part I, we developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation. In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we report the observed effects of frequency regulation on building control and provide suggestions for realworld implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (07431619) , 4846-4853
Demand response with moving horizon estimation of individual thermostatic load states from aggregate power measurements
We present an optimization-based state estimation method that allows us to estimate the states of individual thermostatically controlled loads (TCLs), such as air conditioners and space heaters, from measurements of the power consumption of small aggregations of TCLs. The state estimator can be used together with a controller to provide ancillary services to power systems such as frequency control. The main advantage of this method is that it is designed to work with existing communication infrastructure. We assume that aggregate power measurements are available from distribution substations every few seconds, while TCL state measurements are available from smart meters only every 20 minutes. We model TCLs as hybrid systems and propose a moving horizon state estimator (MHSE), which is formulated as a mixed-integer linear program. We demonstrate the performance of the MHSE in two case studies: (a) estimation of TCL states in the absence of external control actions, and (b) a power tracking problem with closed-loop control using broadcast control inputs. To demonstrate the robustness of the method, we conduct a parametric analysis with respect to aggregation size and diversity, process noise characteristics, and control trajectory characteristics. The results show that the method generally provides accurate estimates of TCL states, resulting in improved controller performance in most cases, and is implementable in real-time with reasonable computational power.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (07431619) , 4846-4853
Demand response with moving horizon estimation of individual thermostatic load states from aggregate power measurements
We present an optimization-based state estimation method that allows us to estimate the states of individual thermostatically controlled loads (TCLs), such as air conditioners and space heaters, from measurements of the power consumption of small aggregations of TCLs. The state estimator can be used together with a controller to provide ancillary services to power systems such as frequency control. The main advantage of this method is that it is designed to work with existing communication infrastructure. We assume that aggregate power measurements are available from distribution substations every few seconds, while TCL state measurements are available from smart meters only every 20 minutes. We model TCLs as hybrid systems and propose a moving horizon state estimator (MHSE), which is formulated as a mixed-integer linear program. We demonstrate the performance of the MHSE in two case studies: (a) estimation of TCL states in the absence of external control actions, and (b) a power tracking problem with closed-loop control using broadcast control inputs. To demonstrate the robustness of the method, we conduct a parametric analysis with respect to aggregation size and diversity, process noise characteristics, and control trajectory characteristics. The results show that the method generally provides accurate estimates of TCL states, resulting in improved controller performance in most cases, and is implementable in real-time with reasonable computational power.