Hosang Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hosang Jeon has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Yongkan Ki
Department of Radiation Oncology and Research Institute, Pusan National University Yangsan Hospital and Pusan National University School of Medicine, Yangsan, Republic of Korea
14 shared publications - Dahl Park
Department of Radiation Oncology, Pusan National University Hospital, Busan, Korea
10 shared publications - Jiho Nam
Department of Radiation Oncology, Pusan National University Hospital, Busan, Korea
10 shared publications - Donghyun Kim
Department of Radiation Oncology, Pusan National University School of Medicine, Yangsan, Korea
8 shared publications - Ji Hyeon Joo
Department of Radiation Oncology, Pusan National University Yangsan Hospital, Yangsan, Korea
8 shared publications - Wontaek Kim
Department of Radiation Oncology, Pusan National University School of Medicine, Yangsan, Korea
8 shared publications
Latest Publications
- Open Access
- 20 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (6) , 2114
Effectiveness of Radiation Shields to Minimize Operator Dose in the Bronchoscopy Suite: A Phantom Study and Clinical Application
Background/Objectives: Fluoroscopy has been widely adopted in interventional pulmonology, as it facilitates real-time visualization of the bronchoscope, endobronchial ultrasound, and biopsy tools during procedures. The purpose of this study was to evaluate the effectiveness of radiation shields in minimizing scattered X-ray dose to the bronchoscopist in a phantom study and to determine the dose of scattered X-ray dose to medical staff with radiation shields in clinical application. Methods: An anthropomorphic torso phantom was positioned on the fluoroscopic table between the C-arm X-ray tube and the image detector to mimic bronchoscopic operations. Upper and lower body lead shields were used to examine the effectiveness of radiation shielding. Scatter radiation rates were assessed at a first operator location using real-time dosimeters with and without protective devices. In clinical application, the scattered X-ray dose of the first operator and main assistant was measured using wearable radiation dosimeters during 20 procedures. Results: In the phantom study, scattered radiation without shielding was 266.34 ± 8.86 μSv/h (glabella), 483.90 ± 8.01 μSv/h (upper thorax), 143.97 ± 8.20 μSv/h (hypogastrium), and 7.22 ± 0.28 μSv/h (ankle). The combination of upper and lower body lead shields reduced the scattered X-ray dose by 98.7%, 98.3%, 66.2%, and 79.9% at these levels, respectively. In clinical application, mean scattered X-ray dose rates were 0.14 ± 0.05 μSv/procedure (eye), 0.46 ± 0.51 μSv/procedure (chest), 0.67 ± 0.50 μSv/procedure (hypogastrium), and 1.57 ± 2.84 μSv/procedure (assistant’s wrist). Conclusions: The combination of radiation shields significantly reduced the scattered X-ray dose at the operator site in the phantom study. The scattered X-ray dose to medical staff during bronchoscopy can be kept at a low level with the aid of a shielding system.
- 20 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (6) , 2114
Open AccessEffectiveness of Radiation Shields to Minimize Operator Dose in the Bronchoscopy Suite: A Phantom Study and Clinical Application
Background/Objectives: Fluoroscopy has been widely adopted in interventional pulmonology, as it facilitates real-time visualization of the bronchoscope, endobronchial ultrasound, and biopsy tools during procedures. The purpose of this study was to evaluate the effectiveness of radiation shields in minimizing scattered X-ray dose to the bronchoscopist in a phantom study and to determine the dose of scattered X-ray dose to medical staff with radiation shields in clinical application. Methods: An anthropomorphic torso phantom was positioned on the fluoroscopic table between the C-arm X-ray tube and the image detector to mimic bronchoscopic operations. Upper and lower body lead shields were used to examine the effectiveness of radiation shielding. Scatter radiation rates were assessed at a first operator location using real-time dosimeters with and without protective devices. In clinical application, the scattered X-ray dose of the first operator and main assistant was measured using wearable radiation dosimeters during 20 procedures. Results: In the phantom study, scattered radiation without shielding was 266.34 ± 8.86 μSv/h (glabella), 483.90 ± 8.01 μSv/h (upper thorax), 143.97 ± 8.20 μSv/h (hypogastrium), and 7.22 ± 0.28 μSv/h (ankle). The combination of upper and lower body lead shields reduced the scattered X-ray dose by 98.7%, 98.3%, 66.2%, and 79.9% at these levels, respectively. In clinical application, mean scattered X-ray dose rates were 0.14 ± 0.05 μSv/procedure (eye), 0.46 ± 0.51 μSv/procedure (chest), 0.67 ± 0.50 μSv/procedure (hypogastrium), and 1.57 ± 2.84 μSv/procedure (assistant’s wrist). Conclusions: The combination of radiation shields significantly reduced the scattered X-ray dose at the operator site in the phantom study. The scattered X-ray dose to medical staff during bronchoscopy can be kept at a low level with the aid of a shielding system.
- Open Access
- 30 June 2024
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 35 (2) , 52-57
Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong Lee, Dong Woon Kim, Ji Hyeon Joo, Yongkan Ki, Wontaek Kim, Dahl Park, Jiho Nam, Dong Hyeon Kim, Hosang Jeon. Progress in Medical Physics 2024;35:52-7. https://doi.org/10.14316/pmp.2024.35.2.52
- 30 June 2024
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 35 (2) , 52-57
Open AccessSimulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong Lee, Dong Woon Kim, Ji Hyeon Joo, Yongkan Ki, Wontaek Kim, Dahl Park, Jiho Nam, Dong Hyeon Kim, Hosang Jeon. Progress in Medical Physics 2024;35:52-7. https://doi.org/10.14316/pmp.2024.35.2.52
- 1 May 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1098-S1099
PO-1368 Albumin-Bilirubin (ALBI) score predicts hepatotoxicity after stereotactic ablative radiation therapy
- 1 May 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1098-S1099
PO-1368 Albumin-Bilirubin (ALBI) score predicts hepatotoxicity after stereotactic ablative radiation therapy
- Open Access
- 1 January 2023
- Published by The Korean Orthopaedic Trauma Association in Journal of the Korean Fracture Society
- Vol. 36 (4) , 111-117
The Efficiency of Radiation Shielding Sheet to Reduce Radiation Exposure during C-arm Fluoroscopy
전호상, et al. J Korean Fract Soc. 2023 Oct;36(4):111-117. https://doi.org/10.12671/jkfs.2023.36.4.111
- 1 January 2023
- Published by The Korean Orthopaedic Trauma Association in Journal of the Korean Fracture Society
- Vol. 36 (4) , 111-117
Open AccessThe Efficiency of Radiation Shielding Sheet to Reduce Radiation Exposure during C-arm Fluoroscopy
전호상, et al. J Korean Fract Soc. 2023 Oct;36(4):111-117. https://doi.org/10.12671/jkfs.2023.36.4.111
- Open Access
- 31 December 2022
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 33 (4) , 101-107
Minimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer
Hojeong Lee, Dong Woon Kim, Ji Hyeon Joo, Yongkan Ki, Wontaek Kim , Dahl Park, Jiho Nam, Dong Hyeon Kim, Hosang Jeon. Progress in Medical Physics 2022;33:101-7. https://doi.org/10.14316/pmp.2022.33.4.101
- 31 December 2022
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 33 (4) , 101-107
Open AccessMinimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer
Hojeong Lee, Dong Woon Kim, Ji Hyeon Joo, Yongkan Ki, Wontaek Kim , Dahl Park, Jiho Nam, Dong Hyeon Kim, Hosang Jeon. Progress in Medical Physics 2022;33:101-7. https://doi.org/10.14316/pmp.2022.33.4.101
- 2 June 2022
- Published by Wiley in Asia-Pacific Journal of Clinical Oncology
- Vol. 19 (2) , E54-E59
Influence of respiratory movement during post mastectomy radiotherapy on targets and heart for breast cancer
Background/aim This study aimed to compare the dosimetric consequences of respiratory movement in volumetric-modulated arc therapy (VMAT) and three-dimensional conformal radiation therapy (3D-CRT) during postmastectomy radiation therapy, including internal mammary nodes (IMNs). Materials and methods Respiratory motion was implemented to a phantom using a dynamic device. The plans were delivered during cranial-caudal and ventral-dorsal movement in 5-mm (R05) and 10-mm (R10) amplitudes. Results At the IMN, the dose errors were -2.8% (R05) and -6.2% (R10) for 3D-CRT and -4.9% (R05) and -8.5% (R10) for VMAT. The dose errors in chest wall were -.5% (R05) and -6.0% (R10) for 3D-CRT and -1.9% (R05) and -5.3% (R10) for VMAT. The left anterior descending doses showed significantly small absolute values. The gamma pass rates of VMAT were higher than those of 3D-CRT. Conclusions The benefit of VMAT technique in dose distribution was maintained, except in occasional instances of large breathing motion.
- 2 June 2022
- Published by Wiley in Asia-Pacific Journal of Clinical Oncology
- Vol. 19 (2) , E54-E59
Influence of respiratory movement during post mastectomy radiotherapy on targets and heart for breast cancer
Background/aim This study aimed to compare the dosimetric consequences of respiratory movement in volumetric-modulated arc therapy (VMAT) and three-dimensional conformal radiation therapy (3D-CRT) during postmastectomy radiation therapy, including internal mammary nodes (IMNs). Materials and methods Respiratory motion was implemented to a phantom using a dynamic device. The plans were delivered during cranial-caudal and ventral-dorsal movement in 5-mm (R05) and 10-mm (R10) amplitudes. Results At the IMN, the dose errors were -2.8% (R05) and -6.2% (R10) for 3D-CRT and -4.9% (R05) and -8.5% (R10) for VMAT. The dose errors in chest wall were -.5% (R05) and -6.0% (R10) for 3D-CRT and -1.9% (R05) and -5.3% (R10) for VMAT. The left anterior descending doses showed significantly small absolute values. The gamma pass rates of VMAT were higher than those of 3D-CRT. Conclusions The benefit of VMAT technique in dose distribution was maintained, except in occasional instances of large breathing motion.
- 7 February 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 80 (5) , 436
Erratum to: A metallic buildup cap for glass rod dosimeters in radiotherapeutic in vivo dosimetry
- 7 February 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 80 (5) , 436
Erratum to: A metallic buildup cap for glass rod dosimeters in radiotherapeutic in vivo dosimetry
- Open Access
- 15 September 2021
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 82 (6) , 1477-1492
Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study
김빛별, et al. J Korean Soc Radiol. 2021 Nov;82(6):1477-1492. https://doi.org/10.3348/jksr.2020.0191
- 15 September 2021
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 82 (6) , 1477-1492
Open AccessAdaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study
김빛별, et al. J Korean Soc Radiol. 2021 Nov;82(6):1477-1492. https://doi.org/10.3348/jksr.2020.0191
- Open Access
- 31 March 2021
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 32 (1) , 18-24
Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study
Hosang Jeon , Dong Woon Kim , Ji Hyeon Joo , Yongkan Ki , Wontaek Kim , Dahl Park, Jiho Nam , Dong Hyeon Kim. Progress in Medical Physics 2021;32:18-24. https://doi.org/10.14316/pmp.2021.32.1.18
- 31 March 2021
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 32 (1) , 18-24
Open AccessFeasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study
Hosang Jeon , Dong Woon Kim , Ji Hyeon Joo , Yongkan Ki , Wontaek Kim , Dahl Park, Jiho Nam , Dong Hyeon Kim. Progress in Medical Physics 2021;32:18-24. https://doi.org/10.14316/pmp.2021.32.1.18