Tarakeswar Shaw
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tarakeswar Shaw has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Debasis Mitra
Department of Electronics and Telecommunication Engineering Indian Institute of Engineering Science and Technology Shibpur Howrah India
7 shared publications- Debasis Mitra
Department of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, India
5 shared publications - Bappaditya Mandal
Department of Electrical Engineering, Microwaves in Medical Engineering Group, Division of Integrated Smart Systems Technology, Uppsala University, Uppsala, Sweden
4 shared publications - Robin Augustine
Department of Electrical Engineering, Angstrom Laboratory, Division of Solid State Electronics, Uppsala University, Uppsala, Sweden
4 shared publications - Johan Engstrand
Department of Electrical Engineering, Microwaves in Medical Engineering Group, Division of Solid-State Electronics, Uppsala University, Sweden
2 shared publications - Roger L. Karlsson
Department of Electrical Engineering, Microwaves in Medical Engineering Group, Division of Solid-State Electronics, Uppsala University, Sweden
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Design and analysis of a compact multi-band flexible metasurface with low-loss characteristics for S, C, and X-band applications
In this study, the focus is on developing a compact, multi-band, and flexible metasurface (MS) with low-loss characteristics for microwave applications. Recently, there has been a strong need to explore MS designs that can efficiently operate across multiple resonance bands while maintaining a compact size and low loss for advanced performance in ever-increasing microwave technology. The unit cell configuration of the MS is designed using three split-ring resonators (SRRs) interconnected with a spiral notch to achieve multi-resonance characteristics with low loss. The miniaturization of the proposed MS is achieved through inductive loading, which is enabled by extending the metallic strip length within the unit cell. Increasing the metal length increases the effective inductance-to-capacitance ratio (L/C), resulting not only in greater compactness but also lower loss. Despite its compact size and low loss, the numerical simulation results reveal that the proposed SRR-MS unit cell exhibits hexa-resonance frequencies at 2.7 GHz (S-band), 4.22 GHz, 6.25 GHz (C-band), 8.27 GHz, 9.65 GHz, and 10.95 GHz (X-band), respectively. The proposed MS exhibits six distinct $$\epsilon$$ -negative (ENG) regions and one $$\mu$$ -negative (MNG) region across the S, C, and X microwave frequency bands with high refractive index (HRI) properties near all six resonances. Importantly, the low-loss behavior is maintained across all six resonance frequencies of the MS. Additionally, the MS is designed on a single-sided flexible dielectric substrate, and its performance characteristics remain stable to some extent under bending and twisting.- 29 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessDesign and analysis of a compact multi-band flexible metasurface with low-loss characteristics for S, C, and X-band applications
In this study, the focus is on developing a compact, multi-band, and flexible metasurface (MS) with low-loss characteristics for microwave applications. Recently, there has been a strong need to explore MS designs that can efficiently operate across multiple resonance bands while maintaining a compact size and low loss for advanced performance in ever-increasing microwave technology. The unit cell configuration of the MS is designed using three split-ring resonators (SRRs) interconnected with a spiral notch to achieve multi-resonance characteristics with low loss. The miniaturization of the proposed MS is achieved through inductive loading, which is enabled by extending the metallic strip length within the unit cell. Increasing the metal length increases the effective inductance-to-capacitance ratio (L/C), resulting not only in greater compactness but also lower loss. Despite its compact size and low loss, the numerical simulation results reveal that the proposed SRR-MS unit cell exhibits hexa-resonance frequencies at 2.7 GHz (S-band), 4.22 GHz, 6.25 GHz (C-band), 8.27 GHz, 9.65 GHz, and 10.95 GHz (X-band), respectively. The proposed MS exhibits six distinct $$\epsilon$$ -negative (ENG) regions and one $$\mu$$ -negative (MNG) region across the S, C, and X microwave frequency bands with high refractive index (HRI) properties near all six resonances. Importantly, the low-loss behavior is maintained across all six resonance frequencies of the MS. Additionally, the MS is designed on a single-sided flexible dielectric substrate, and its performance characteristics remain stable to some extent under bending and twisting. - 13 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2031-2043
High-Speed Intra-Body Communication System Through Fat Tissue Using Wearable Antennas for Health Monitoring
In this article, the design of a non-invasive wearable antenna-based fat intra-body communication (Fat-IBC) system is presented for biomedical applications. The Fat-IBC system is used for uninterrupted communication between various wearable, implanted, and semi-implanted devices, facilitating the exchange of data and information within body area networks (BAN). Herein, to eliminate the design complexity, a simple planar-loop antenna is considered to establish the Fat-IBC link. For the numerical analysis, a three-layer human body tissue model (skin, fat, and muscle) is considered to optimize the antenna. A polydimethylsiloxane (PDMS) coating layer is deposited around the wearable antenna to eliminate direct contact with the human body. In addition, the antenna has also been shielded by a ferrite substrate and copper tape to reduce the loss of energy in undesired directions and stop the surface wave propagation over the skin tissue. The Fat-IBC system is constructed by using two identical wearable antennas that act as transmitting (Tx) and receiving (Rx) elements. These antennas have been placed on the three-layer human body tissue models at different distances to demonstrate the data transmission. The concept of the proposed wearable antenna-based Fat-IBC system has been established by numerical simulations and validated by experimental studies using phantoms. The proposed data transmission link was characterized using scattering parameters and the IEEE 802.11n wireless communication standard with combinations of on-skin wearable antennas. To achieve high in-body data rate using on-body antennas through the fat layer, a wireless LAN at the 2.4 GHz band was tested using low-cost Raspberry Pi single-board computers. The phantoms are utilized for measurement purposes to emulate the human body. For the proposed Fat-IBC system, a maximum link speed of 93 Mb/s is achieved using the 40 MHz bandwidth provided by the IEEE 802.11n standard at the frequency of 2.4 GHz. The obtained results demonstrate that the proposed Fat-IBC system, utilizing low-cost off-the-shelf hardware and established IEEE 802.11 wireless communication, can achieve high-speed data communication through three-layer phantom tissue.
- 13 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2031-2043
High-Speed Intra-Body Communication System Through Fat Tissue Using Wearable Antennas for Health Monitoring
In this article, the design of a non-invasive wearable antenna-based fat intra-body communication (Fat-IBC) system is presented for biomedical applications. The Fat-IBC system is used for uninterrupted communication between various wearable, implanted, and semi-implanted devices, facilitating the exchange of data and information within body area networks (BAN). Herein, to eliminate the design complexity, a simple planar-loop antenna is considered to establish the Fat-IBC link. For the numerical analysis, a three-layer human body tissue model (skin, fat, and muscle) is considered to optimize the antenna. A polydimethylsiloxane (PDMS) coating layer is deposited around the wearable antenna to eliminate direct contact with the human body. In addition, the antenna has also been shielded by a ferrite substrate and copper tape to reduce the loss of energy in undesired directions and stop the surface wave propagation over the skin tissue. The Fat-IBC system is constructed by using two identical wearable antennas that act as transmitting (Tx) and receiving (Rx) elements. These antennas have been placed on the three-layer human body tissue models at different distances to demonstrate the data transmission. The concept of the proposed wearable antenna-based Fat-IBC system has been established by numerical simulations and validated by experimental studies using phantoms. The proposed data transmission link was characterized using scattering parameters and the IEEE 802.11n wireless communication standard with combinations of on-skin wearable antennas. To achieve high in-body data rate using on-body antennas through the fat layer, a wireless LAN at the 2.4 GHz band was tested using low-cost Raspberry Pi single-board computers. The phantoms are utilized for measurement purposes to emulate the human body. For the proposed Fat-IBC system, a maximum link speed of 93 Mb/s is achieved using the 40 MHz bandwidth provided by the IEEE 802.11n standard at the frequency of 2.4 GHz. The obtained results demonstrate that the proposed Fat-IBC system, utilizing low-cost off-the-shelf hardware and established IEEE 802.11 wireless communication, can achieve high-speed data communication through three-layer phantom tissue.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 13785-13796
Design and Analysis of Low Profile Antenna Shielding to Enhance the Performance of Wearable Fat-IBC System
This article introduces a detailed analysis about the effect of shielding on the performance of a resonating antenna-based wearable fat intra-body communication (Fat-IBC) system for biotelemetry applications. The Fat-IBC wearable antenna resonator is designed using a planar circular spiral resonator with a notch excited by a loop antenna. The resonator is optimized on a three-layer human body tissue model (skin, fat, and muscle) by numerical studies. A polydimethylsiloxane (PDMS) coating surrounds the resonator to prevent direct contact with the body. Further, ferrite substrate and copper tapes are used to construct a low profile shielding over the PDMS-coated wearable resonator to minimize undesired energy loss and surface wave propagation over the skin tissue. The Fat-IBC system is constructed with two identical antenna resonators acting as transmitting (Tx) and receiving (Rx) elements, placed at varying distances on the skin layer to demonstrate data transmission. The concept of the proposed Fat-IBC system has been validated through numerical simulations and experimental studies for shielded and unshielded configurations with a three-layer phantom model. The data transmission link was characterized using scattering parameters and the IEEE 802.11n wireless communication standard. The measurement study shows the transmission coefficient for shielded antennas of about –42.5 dB and –52.41 dB, while –40.91 dB and –51.13 dB were achieved from unshielded antennas at distances of 10 cm and 20 cm, respectively. Moreover, using low-cost Raspberry Pi single-board computers and the 40 MHz bandwidth provided by the IEEE 802.11n standard, the Fat-IBC system achieved a maximum link speed of 92.4 Mb/s through phantom with shielded resonator, while 79.6 Mb/s for unshielded configuration. The result obtained from the measurements establishes the feasibility of the proposed Fat- IBC system based on resonating antennas and shows the importance of shielding.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 13785-13796
Design and Analysis of Low Profile Antenna Shielding to Enhance the Performance of Wearable Fat-IBC System
This article introduces a detailed analysis about the effect of shielding on the performance of a resonating antenna-based wearable fat intra-body communication (Fat-IBC) system for biotelemetry applications. The Fat-IBC wearable antenna resonator is designed using a planar circular spiral resonator with a notch excited by a loop antenna. The resonator is optimized on a three-layer human body tissue model (skin, fat, and muscle) by numerical studies. A polydimethylsiloxane (PDMS) coating surrounds the resonator to prevent direct contact with the body. Further, ferrite substrate and copper tapes are used to construct a low profile shielding over the PDMS-coated wearable resonator to minimize undesired energy loss and surface wave propagation over the skin tissue. The Fat-IBC system is constructed with two identical antenna resonators acting as transmitting (Tx) and receiving (Rx) elements, placed at varying distances on the skin layer to demonstrate data transmission. The concept of the proposed Fat-IBC system has been validated through numerical simulations and experimental studies for shielded and unshielded configurations with a three-layer phantom model. The data transmission link was characterized using scattering parameters and the IEEE 802.11n wireless communication standard. The measurement study shows the transmission coefficient for shielded antennas of about –42.5 dB and –52.41 dB, while –40.91 dB and –51.13 dB were achieved from unshielded antennas at distances of 10 cm and 20 cm, respectively. Moreover, using low-cost Raspberry Pi single-board computers and the 40 MHz bandwidth provided by the IEEE 802.11n standard, the Fat-IBC system achieved a maximum link speed of 92.4 Mb/s through phantom with shielded resonator, while 79.6 Mb/s for unshielded configuration. The result obtained from the measurements establishes the feasibility of the proposed Fat- IBC system based on resonating antennas and shows the importance of shielding.
- Open Access
- 2 July 2021
- Published by Hindawi Limited in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 31 (9) , e22791
Design of highly directive slot antenna using metamaterial structure under optimal condition
In this article, a highly directive slot antenna design using a parallel incident magnetic metamaterial (MTM) structure has been presented. A split ring resonator (SRR) structure having mu near-zero and epsilon very large with low impedance behavior is employed to enhance the directivity of the antenna. In the proposed optimized design, four-MTM slabs with an array of SRR unit cell have been placed perpendicularly over the slot antenna to enhance the directivity. The thickness of utilized MTM slab in the vertical direction is under the optimal condition, which is highly desired to obtain better improvement in directivity. In spite of directivity enhancement of about 6 dB, antenna miniaturization of 11.4% is also obtained due to the loading effect of the MTM slab. The proposed directivity enhancement approach of the slot antenna is established by simulation and verified by measurements. It is perceived from both measured and simulated results that over the whole working band, a significant directivity enhancement is sustained along with reduced backward radiation compared to the unloaded slot.- 2 July 2021
- Published by Hindawi Limited in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 31 (9) , e22791
Open AccessDesign of highly directive slot antenna using metamaterial structure under optimal condition
In this article, a highly directive slot antenna design using a parallel incident magnetic metamaterial (MTM) structure has been presented. A split ring resonator (SRR) structure having mu near-zero and epsilon very large with low impedance behavior is employed to enhance the directivity of the antenna. In the proposed optimized design, four-MTM slabs with an array of SRR unit cell have been placed perpendicularly over the slot antenna to enhance the directivity. The thickness of utilized MTM slab in the vertical direction is under the optimal condition, which is highly desired to obtain better improvement in directivity. In spite of directivity enhancement of about 6 dB, antenna miniaturization of 11.4% is also obtained due to the loading effect of the MTM slab. The proposed directivity enhancement approach of the slot antenna is established by simulation and verified by measurements. It is perceived from both measured and simulated results that over the whole working band, a significant directivity enhancement is sustained along with reduced backward radiation compared to the unloaded slot. - Open Access
Design of Metamaterial Based Efficient Wireless Power Transfer System Utilizing Antenna Topology for Wearable Devices
In this article, the design of an efficient wireless power transfer (WPT) system using antenna-based topology for the applications in wearable devices is presented. To implement the wearable WPT system, a simple circular patch antenna is initially designed on a flexible felt substrate by placing over a three-layer human tissue model to utilize as a receiving element. Meanwhile, a high gain circular patch antenna is also designed in the air environment to use as a transmitter for designing the wearable WPT link. The proposed WPT system is built to operate at the industrial, scientific and medical (ISM) band of 2.40–2.48 GHz. In addition, to improve the power transfer efficiency (PTE) of the system, a metamaterial (MTM) slab built with an array combination of 3 × 3 unit cells has been employed. Further, the performance analysis of the MTM integrated system is performed on the different portions of the human body like hand, head and torso model to present the versatile applicability of the system. Moreover, analysis of the specific absorption rate (SAR) has been performed in different wearable scenarios to show the effect on the human body under the standard recommended limits. Regarding the practical application issues, the performance stability analysis of the proposed system due to the misalignment and flexibility of the Rx antenna is executed. Finally, the prototypes are fabricated and experimental validation is performed on several realistic wearable platforms like three-layer pork tissue slab, human hand, head and body. The simulated and measured result confirms that by using the MTM slab, a significant amount of the PTE improvement is obtained from the proposed system.
Open AccessDesign of Metamaterial Based Efficient Wireless Power Transfer System Utilizing Antenna Topology for Wearable Devices
In this article, the design of an efficient wireless power transfer (WPT) system using antenna-based topology for the applications in wearable devices is presented. To implement the wearable WPT system, a simple circular patch antenna is initially designed on a flexible felt substrate by placing over a three-layer human tissue model to utilize as a receiving element. Meanwhile, a high gain circular patch antenna is also designed in the air environment to use as a transmitter for designing the wearable WPT link. The proposed WPT system is built to operate at the industrial, scientific and medical (ISM) band of 2.40–2.48 GHz. In addition, to improve the power transfer efficiency (PTE) of the system, a metamaterial (MTM) slab built with an array combination of 3 × 3 unit cells has been employed. Further, the performance analysis of the MTM integrated system is performed on the different portions of the human body like hand, head and torso model to present the versatile applicability of the system. Moreover, analysis of the specific absorption rate (SAR) has been performed in different wearable scenarios to show the effect on the human body under the standard recommended limits. Regarding the practical application issues, the performance stability analysis of the proposed system due to the misalignment and flexibility of the Rx antenna is executed. Finally, the prototypes are fabricated and experimental validation is performed on several realistic wearable platforms like three-layer pork tissue slab, human hand, head and body. The simulated and measured result confirms that by using the MTM slab, a significant amount of the PTE improvement is obtained from the proposed system.
- 21 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 69 (7) , 4109-4122
Efficient Wireless Power Transfer System for Implantable Medical Devices Using Circular Polarized Antennas
In this paper, we present a novel approach for designing a rotation insensitive, biocompatible, circular polarization-based efficient wireless power transfer (WPT) system for implantable medical devices (IMDs) in the radiative near-field region. Initially, a wideband, biocompatible, flexible circular polarized (CP) slot antenna is designed inside a single layer skin tissue model to use as a receiving (Rx) element. To create the WPT link, a simple square patch antenna with the truncated corners is constructed to utilize as a transmitting (Tx) element. Further, a polarization conversion-based metamaterial (MTM) structure is built particularly to improve the power transfer efficiency (PTE) of the proposed WPT system. Also, to show the versatility, the performance analysis of the proposed MTM integrated WPT system is conducted inside the human torso and head model. Moreover, a detailed study of the specific absorption rate (SAR) is accomplished regarding the safety of the human body in the light of IEEE regulation. Finally, the prototypes of the proposed WPT system are fabricated and experimentally verified in skin-mimicking gel and minced pork. The experimental result confirms the feasibility of the proposed concept by enhancing the PTE of the presented system by the usage of the MTM slab.
- 21 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 69 (7) , 4109-4122
Efficient Wireless Power Transfer System for Implantable Medical Devices Using Circular Polarized Antennas
In this paper, we present a novel approach for designing a rotation insensitive, biocompatible, circular polarization-based efficient wireless power transfer (WPT) system for implantable medical devices (IMDs) in the radiative near-field region. Initially, a wideband, biocompatible, flexible circular polarized (CP) slot antenna is designed inside a single layer skin tissue model to use as a receiving (Rx) element. To create the WPT link, a simple square patch antenna with the truncated corners is constructed to utilize as a transmitting (Tx) element. Further, a polarization conversion-based metamaterial (MTM) structure is built particularly to improve the power transfer efficiency (PTE) of the proposed WPT system. Also, to show the versatility, the performance analysis of the proposed MTM integrated WPT system is conducted inside the human torso and head model. Moreover, a detailed study of the specific absorption rate (SAR) is accomplished regarding the safety of the human body in the light of IEEE regulation. Finally, the prototypes of the proposed WPT system are fabricated and experimentally verified in skin-mimicking gel and minced pork. The experimental result confirms the feasibility of the proposed concept by enhancing the PTE of the presented system by the usage of the MTM slab.
- 8 August 2020
- Published by Hindawi Limited in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 30 (11)
Design of miniaturized highly sensitive liquid sensor at microwave frequency
In this paper, we have presented a simple, miniaturized, and highly sensitive liquid sensor, which determines the dielectric properties of liquids at microwave frequency. In the proposed design, the concept of interdigital capacitor (IDC) is employed to construct the sensor. The proposed IDC based sensor responds differently depending on the liquids' dielectric property. The proposed structure utilizes the shift in resonance frequency and peak attenuation as the sensing parameter to determine the complex dielectric permittivity of the unknown liquids. The advantage of the proposed sensor structure lies in its compactness (0.08λ0 × 0.08λ0 × 0.003λ0) and high sensitivity, 0.42%. The designed sensor can also be used in the biomedical field for noninvasive bio‐liquid characterization.
- 8 August 2020
- Published by Hindawi Limited in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 30 (11)
Design of miniaturized highly sensitive liquid sensor at microwave frequency
In this paper, we have presented a simple, miniaturized, and highly sensitive liquid sensor, which determines the dielectric properties of liquids at microwave frequency. In the proposed design, the concept of interdigital capacitor (IDC) is employed to construct the sensor. The proposed IDC based sensor responds differently depending on the liquids' dielectric property. The proposed structure utilizes the shift in resonance frequency and peak attenuation as the sensing parameter to determine the complex dielectric permittivity of the unknown liquids. The advantage of the proposed sensor structure lies in its compactness (0.08λ0 × 0.08λ0 × 0.003λ0) and high sensitivity, 0.42%. The designed sensor can also be used in the biomedical field for noninvasive bio‐liquid characterization.
- 9 December 2019
- Published by Springer Nature in Applied Physics A
- Vol. 126 (1) , 13
Design of metamaterial-based compact and highly sensitive microwave liquid sensor
- 9 December 2019
- Published by Springer Nature in Applied Physics A
- Vol. 126 (1) , 13
Design of metamaterial-based compact and highly sensitive microwave liquid sensor
- 24 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 18 (9) , 1823-1827
Wireless Power Transfer System Based on Magnetic Dipole Coupling With High Permittivity Metamaterials
- 24 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 18 (9) , 1823-1827
Wireless Power Transfer System Based on Magnetic Dipole Coupling With High Permittivity Metamaterials
- Open Access
- 24 June 2019
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 13 (12) , 1974-1982
Metasurface‐based radiative near‐field wireless power transfer system for implantable medical devices
This article presents a novel approach to improve the efficiency of a radiative near‐field wireless power transfer (WPT) system by using metasurface. The WPT system is designed particularly for implantable applications, which operate at the industrial, scientific, and medical (ISM) 2.40–2.48 GHz band. To construct the WPT link, a patch antenna is used as the transmitting element whereas a small planar loop antenna is considered as the receiving element. The receiving antenna is implanted under the skin tissue model operating at 2.45 GHz. The metasurface with a high refractive index is placed above the surface of the skin layer to improve the power transfer efficiency. Regarding the motion of the human body, different misalignment tolerances between the transmitter and the implant receiver are discussed. Also, the effect in the change of the skin property and placement depth of the Rx antenna inside the skin tissue model is studied. Furthermore, the study of specific absorption rate for the proposed configuration is performed. Finally, the proposed WPT system is designed and experimentally verified with and without metasurface. The experimental result confirms a significant amount of improvement in power transfer efficiency due to the integration of metasurface.
- 24 June 2019
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 13 (12) , 1974-1982
Open AccessMetasurface‐based radiative near‐field wireless power transfer system for implantable medical devices
This article presents a novel approach to improve the efficiency of a radiative near‐field wireless power transfer (WPT) system by using metasurface. The WPT system is designed particularly for implantable applications, which operate at the industrial, scientific, and medical (ISM) 2.40–2.48 GHz band. To construct the WPT link, a patch antenna is used as the transmitting element whereas a small planar loop antenna is considered as the receiving element. The receiving antenna is implanted under the skin tissue model operating at 2.45 GHz. The metasurface with a high refractive index is placed above the surface of the skin layer to improve the power transfer efficiency. Regarding the motion of the human body, different misalignment tolerances between the transmitter and the implant receiver are discussed. Also, the effect in the change of the skin property and placement depth of the Rx antenna inside the skin tissue model is studied. Furthermore, the study of specific absorption rate for the proposed configuration is performed. Finally, the proposed WPT system is designed and experimentally verified with and without metasurface. The experimental result confirms a significant amount of improvement in power transfer efficiency due to the integration of metasurface.